Removing copper from nickel electrolysis anode solution has been a major keypoint in the nickel metallurgy industry.In this study,we proposed a novel process flow to promote removing copper from nickel electrolysis an...Removing copper from nickel electrolysis anode solution has been a major keypoint in the nickel metallurgy industry.In this study,we proposed a novel process flow to promote removing copper from nickel electrolysis anode solution.A simulated nickel anode solution was designed,and static and dynamic adsorption experiments were conducted to determine the best of solution pH,adsorption time and temperature,resin dosage and particle size,and stirring speed.The optimal conditions were explored for copper removal from nickel electrolysis anode solution.Based on the optimal experimental conditions and the relevant experimental data,a novel process for copper removal from nickel electrolysis anodes was designed and verified.This novel process of copper removal from nickel electrolysis anodes was confirmed with nickel anolyte solution with nickel 50−60 g/L and copper 0.5 g/L.After finishing the novel process of copper removal,the nickel in the purified nickel anolyte became undetectable and copper concentration was 3 mg/L,the novel process of resin adsorption to remove copper from nickel anode solution through static and dynamic adsorptions has an efficacious copper removal.It is a beneficial supplement to traditional methods.展开更多
The exchanged hypercube EH(s, t) (where s ≥ 1 and t ≥ 1) is obtained by systematically reducing links from a regular hypercube Q,+t+l. One-step diagnosis of exchanged hypercubes which involves only one testi...The exchanged hypercube EH(s, t) (where s ≥ 1 and t ≥ 1) is obtained by systematically reducing links from a regular hypercube Q,+t+l. One-step diagnosis of exchanged hypercubes which involves only one testing phase during which processors test each other is discussed. The diagnosabilities of exchanged hypercubes are studied by using the pessimistic one-step diagno- sis strategy under two kinds of diagnosis models: the PMC model and the MM model. The main results presented here are the two proofs that the degree of diagnosability of the EH(s, t) under pessimistic one-step tl/tl fault diagnosis strategy is 2s where I ≤ s ≤ t (respectively, 2t, where 1 ≤ t ≤ s) based on the PMC model and that it is also 2s where 1 ≤ s ≤ t (respectively, 2t, where 1 ≤ t ≤ s) based on the MM* model.展开更多
A high-aspect-ratio microchannel heat exchanger based on multi-tool milling process was developed. Several slotting cutters were stacked together for simultaneously machining several high-aspect-ratio microchannels wi...A high-aspect-ratio microchannel heat exchanger based on multi-tool milling process was developed. Several slotting cutters were stacked together for simultaneously machining several high-aspect-ratio microchannels with manifold structures. On the basis of multi-tool milling process, the structural design of the manifold side height, microchannel length, width, number, and interval were analyzed. The heat transfer performances of high-aspect-ratio microchannel heat exchangers with two different manifolds were investigated by experiments, and the influencing factors were analyzed. The results indicate that the magnitude of heat transfer area per unit volume dominates the heat transfer performances of plate-type micro heat exchanger, while the velocity distribution between microchannels has little effects on the heat transfer performances.展开更多
In the production process of titanium dioxide with sulfuric acid, the contamination of the titanium sulfate solution (the ilmenite leaching solution) in the Fe 3+ reduction stage by iron scraps is a practical problem ...In the production process of titanium dioxide with sulfuric acid, the contamination of the titanium sulfate solution (the ilmenite leaching solution) in the Fe 3+ reduction stage by iron scraps is a practical problem because it is difficult to guarantee the quality of the iron scraps. In this research, a new method, called the ion exchange membrane primary cell method, for reduction of Fe 3+ in the titanium sulfate solution has been advanced. The positive compartment of the primary cell consists of lead (copper) electrode and the titanium sulfate solution, and the negative compartment consists of iron electrode and acidic FeSO 4 solution. The anion ion exchange membrane is used as the diaphragm between two compartments. Fe 3+ in the titanium sulfate solution is reduced by the electric discharge of the primary cell. The effects of temperature, stirring strength of the solution and membrane area on the reduction rate have been investigated. The experimental result shows that the optimum current density can be higher than 100 A/m 2.展开更多
A process of removing impurities,such as Fe,Zr,Ti,Al,Si,from scandium solution by ion exchange was proposed.Various resins’selectivity was studied in scandium chloride solution.The results indicated that D851resin ha...A process of removing impurities,such as Fe,Zr,Ti,Al,Si,from scandium solution by ion exchange was proposed.Various resins’selectivity was studied in scandium chloride solution.The results indicated that D851resin had high selectivity of Sc at low acidity,and high selectivity of Zr at high acidity;D370resin had high selectivity of Fe and Si in high acidity.A new technical process of removing impurities from scandium chloride solution was proposed,which includes D370resin adsorbing Fe in high acidity,D851resin adsorbing Zr in medium acidity and D851resin adsorbing Sc at low acidity.Flow experimental results show that removal rates of Al,Ca,Fe,Zr,Ti and Si,were100%,99.6%,100%,100%,99.5%and100%respectively.展开更多
The separation of Co 2+ from Zn 2+ , Cd 2+ by anion exchange chromatography was discussed. The chromatographic column containing anion resin 201×7 which was saturated with a solution of ammonium chloride. The eff...The separation of Co 2+ from Zn 2+ , Cd 2+ by anion exchange chromatography was discussed. The chromatographic column containing anion resin 201×7 which was saturated with a solution of ammonium chloride. The effects of the eluant acidity and eluant composition on the separation were investigated. The results indicate that this anion exchange chromatography is suitable to the separation of Co 2+ from Zn 2+ , Cd 2+ , and the condition of separation is simple and convenient. When the column is saturated with NH 4Cl solution (2.0 mol/L, pH=4.0), the separation can be completed effectively. Zn 2+ and Cd 2+ can also be separa ted when different eluants are used and the pure solution with high concentration of Zn 2+ , Cd 2+ respectively can be obtained ea sily.展开更多
基金Project(2019yff0216502)supported by the National Key Research&Development Plan of Ministry of Science and Technology of ChinaProject(2021SK1020-4)supported by the Major Science and Technological Innovation Project of Hunan Province,China。
文摘Removing copper from nickel electrolysis anode solution has been a major keypoint in the nickel metallurgy industry.In this study,we proposed a novel process flow to promote removing copper from nickel electrolysis anode solution.A simulated nickel anode solution was designed,and static and dynamic adsorption experiments were conducted to determine the best of solution pH,adsorption time and temperature,resin dosage and particle size,and stirring speed.The optimal conditions were explored for copper removal from nickel electrolysis anode solution.Based on the optimal experimental conditions and the relevant experimental data,a novel process for copper removal from nickel electrolysis anodes was designed and verified.This novel process of copper removal from nickel electrolysis anodes was confirmed with nickel anolyte solution with nickel 50−60 g/L and copper 0.5 g/L.After finishing the novel process of copper removal,the nickel in the purified nickel anolyte became undetectable and copper concentration was 3 mg/L,the novel process of resin adsorption to remove copper from nickel anode solution through static and dynamic adsorptions has an efficacious copper removal.It is a beneficial supplement to traditional methods.
基金supported by the National Natural Science Fundation of China(61363002)
文摘The exchanged hypercube EH(s, t) (where s ≥ 1 and t ≥ 1) is obtained by systematically reducing links from a regular hypercube Q,+t+l. One-step diagnosis of exchanged hypercubes which involves only one testing phase during which processors test each other is discussed. The diagnosabilities of exchanged hypercubes are studied by using the pessimistic one-step diagno- sis strategy under two kinds of diagnosis models: the PMC model and the MM model. The main results presented here are the two proofs that the degree of diagnosability of the EH(s, t) under pessimistic one-step tl/tl fault diagnosis strategy is 2s where I ≤ s ≤ t (respectively, 2t, where 1 ≤ t ≤ s) based on the PMC model and that it is also 2s where 1 ≤ s ≤ t (respectively, 2t, where 1 ≤ t ≤ s) based on the MM* model.
基金Projects(50675070 50805052) supported by the National Nature Science Foundation of China+1 种基金Projects(07118064 8451064101000320) supported by the Natural Science Foundation of Guangdong Province
文摘A high-aspect-ratio microchannel heat exchanger based on multi-tool milling process was developed. Several slotting cutters were stacked together for simultaneously machining several high-aspect-ratio microchannels with manifold structures. On the basis of multi-tool milling process, the structural design of the manifold side height, microchannel length, width, number, and interval were analyzed. The heat transfer performances of high-aspect-ratio microchannel heat exchangers with two different manifolds were investigated by experiments, and the influencing factors were analyzed. The results indicate that the magnitude of heat transfer area per unit volume dominates the heat transfer performances of plate-type micro heat exchanger, while the velocity distribution between microchannels has little effects on the heat transfer performances.
文摘In the production process of titanium dioxide with sulfuric acid, the contamination of the titanium sulfate solution (the ilmenite leaching solution) in the Fe 3+ reduction stage by iron scraps is a practical problem because it is difficult to guarantee the quality of the iron scraps. In this research, a new method, called the ion exchange membrane primary cell method, for reduction of Fe 3+ in the titanium sulfate solution has been advanced. The positive compartment of the primary cell consists of lead (copper) electrode and the titanium sulfate solution, and the negative compartment consists of iron electrode and acidic FeSO 4 solution. The anion ion exchange membrane is used as the diaphragm between two compartments. Fe 3+ in the titanium sulfate solution is reduced by the electric discharge of the primary cell. The effects of temperature, stirring strength of the solution and membrane area on the reduction rate have been investigated. The experimental result shows that the optimum current density can be higher than 100 A/m 2.
基金Project(2015BAB19B03)supported by the National Science and Technology Supporting Plan of China
文摘A process of removing impurities,such as Fe,Zr,Ti,Al,Si,from scandium solution by ion exchange was proposed.Various resins’selectivity was studied in scandium chloride solution.The results indicated that D851resin had high selectivity of Sc at low acidity,and high selectivity of Zr at high acidity;D370resin had high selectivity of Fe and Si in high acidity.A new technical process of removing impurities from scandium chloride solution was proposed,which includes D370resin adsorbing Fe in high acidity,D851resin adsorbing Zr in medium acidity and D851resin adsorbing Sc at low acidity.Flow experimental results show that removal rates of Al,Ca,Fe,Zr,Ti and Si,were100%,99.6%,100%,100%,99.5%and100%respectively.
文摘The separation of Co 2+ from Zn 2+ , Cd 2+ by anion exchange chromatography was discussed. The chromatographic column containing anion resin 201×7 which was saturated with a solution of ammonium chloride. The effects of the eluant acidity and eluant composition on the separation were investigated. The results indicate that this anion exchange chromatography is suitable to the separation of Co 2+ from Zn 2+ , Cd 2+ , and the condition of separation is simple and convenient. When the column is saturated with NH 4Cl solution (2.0 mol/L, pH=4.0), the separation can be completed effectively. Zn 2+ and Cd 2+ can also be separa ted when different eluants are used and the pure solution with high concentration of Zn 2+ , Cd 2+ respectively can be obtained ea sily.