Inductively-coupled plasma mass spectrometry (ICP-MS) has made much progress since its birth in the late 1990s. This paper will give a rather systematic overview on the use of this technique in new devices and technol...Inductively-coupled plasma mass spectrometry (ICP-MS) has made much progress since its birth in the late 1990s. This paper will give a rather systematic overview on the use of this technique in new devices and technologies related to plasma source, sample-introducing device and detecting spectrometer etc. In this overview, an emphasis will be put on the evaluation of the ICP- MS technique in combination with a series of physical, chemical and biological techniques, such as laser ablation (LA), capillary electrophoresis (CE) and high performance liquid chromatograph (HPLC), along with their representative high accuracy and high sensitivity. Finally, comprehensive and fruitful applications of the ICP-MS and its combinative techniques in the detection of trace metallic elements and isotopes in complex biological and environmental samples will be revealed.展开更多
本文利用微波消解对黄豆进行前处理,采用电感耦合等离子体质谱法(Inductively Coupled Plasma Mass Spectrometer,ICP-MS)对消解液中26种元素的含量进行测定,对方法的线性、精密度、准确度及质控样品进行验证。结果表明,各元素标准曲线...本文利用微波消解对黄豆进行前处理,采用电感耦合等离子体质谱法(Inductively Coupled Plasma Mass Spectrometer,ICP-MS)对消解液中26种元素的含量进行测定,对方法的线性、精密度、准确度及质控样品进行验证。结果表明,各元素标准曲线的相关系数均≥0.9990,线性关系良好,检出限为0.000583~0.453000 mg·kg^(-1),相对标准偏差≤5.513%,加标回收率为77%~113%,说明该方法能准确检测黄豆中无机元素,满足日常监测需求。展开更多
In this paper,the determination of six heavy metal ions (arsenic,lead,cadmium,chromium,mercury and nickel) in the Chinese Herb by inductively coupled plasma-mass spectrometry (ICP-MS) was studied.The samples were dige...In this paper,the determination of six heavy metal ions (arsenic,lead,cadmium,chromium,mercury and nickel) in the Chinese Herb by inductively coupled plasma-mass spectrometry (ICP-MS) was studied.The samples were digested by nitric acid and hydrogen peroxide in a microwave oven.The Sc,Y,In,Bi were added as internal standards to eliminate the matrix interferences.The results show that most of the relative standard deviations of these trace elements were below 3.5%,the standard recoveries of these elements were in the range of 91%-107%,and the detection limits were in the range of 0.001-0.006 μg·L-1. This method is accurate,rapid,convenience,and can be applied to the determination of arsenic,lead,cadmium,chromium,mercury and nickel in Chinese Herb with good results.展开更多
Inductively coupled plasma mass spectrometry(ICP-MS) was used to determine the concentration of Pb in atmospheric particulate samples,and the enrichment factor was calculated.The causes of the results were also discus...Inductively coupled plasma mass spectrometry(ICP-MS) was used to determine the concentration of Pb in atmospheric particulate samples,and the enrichment factor was calculated.The causes of the results were also discussed.展开更多
文摘Inductively-coupled plasma mass spectrometry (ICP-MS) has made much progress since its birth in the late 1990s. This paper will give a rather systematic overview on the use of this technique in new devices and technologies related to plasma source, sample-introducing device and detecting spectrometer etc. In this overview, an emphasis will be put on the evaluation of the ICP- MS technique in combination with a series of physical, chemical and biological techniques, such as laser ablation (LA), capillary electrophoresis (CE) and high performance liquid chromatograph (HPLC), along with their representative high accuracy and high sensitivity. Finally, comprehensive and fruitful applications of the ICP-MS and its combinative techniques in the detection of trace metallic elements and isotopes in complex biological and environmental samples will be revealed.
文摘In this paper,the determination of six heavy metal ions (arsenic,lead,cadmium,chromium,mercury and nickel) in the Chinese Herb by inductively coupled plasma-mass spectrometry (ICP-MS) was studied.The samples were digested by nitric acid and hydrogen peroxide in a microwave oven.The Sc,Y,In,Bi were added as internal standards to eliminate the matrix interferences.The results show that most of the relative standard deviations of these trace elements were below 3.5%,the standard recoveries of these elements were in the range of 91%-107%,and the detection limits were in the range of 0.001-0.006 μg·L-1. This method is accurate,rapid,convenience,and can be applied to the determination of arsenic,lead,cadmium,chromium,mercury and nickel in Chinese Herb with good results.
文摘Inductively coupled plasma mass spectrometry(ICP-MS) was used to determine the concentration of Pb in atmospheric particulate samples,and the enrichment factor was calculated.The causes of the results were also discussed.