期刊文献+
共找到10篇文章
< 1 >
每页显示 20 50 100
Determination of trace elements in high purity nickel by high resolution inductively coupled plasma mass spectrometry 被引量:11
1
作者 聂西度 梁逸曾 +1 位作者 唐有根 谢华林 《Journal of Central South University》 SCIE EI CAS 2012年第9期2416-2420,共5页
The contents ofMg, Al, Si, Ti, Cr, Mn, Fe, Co, Cu, Ga, As, Se, Cd, Sb, Pb and Bi in high purity nickel were determined by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). The sample was diss... The contents ofMg, Al, Si, Ti, Cr, Mn, Fe, Co, Cu, Ga, As, Se, Cd, Sb, Pb and Bi in high purity nickel were determined by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). The sample was dissolved in HNO3 and HCI by microwave digestion. Most of the spectral interferences could be avoided by measuring in the high resolution mode. The matrix effects because of the presence of excess HC1 and nickel were evaluated. Correction for matrix effects was made using Sc, Rh and T1 as internal standards. The optimum conditions for the determination were tested and discussed. The detection limits range from 0.012 to 1.76 ~tg/g depending on the type of elements. The applicability of the proposed method is also validated by the analysis of high purity nickel reference material (NIST SRM 671). The relative standard deviation (RSD) is less than 3.3%. Results for determination of trace elements in high purity nickel were presented. 展开更多
关键词 high resolution inductively coupled plasma mass spectrometry high purity nickel trace element matrix effect internal standard
在线阅读 下载PDF
Determination of trace multi-elements in coal fly ash by inductively coupled plasma mass spectrometry 被引量:5
2
作者 谢华林 唐有根 +1 位作者 李玉杰 李立波 《Journal of Central South University of Technology》 EI 2007年第1期68-72,共5页
The contents of Cr, Cu, Ni, As, Cd and Pb in coal fly ash were determined by a high resolution inductively coupled plasma mass spectrometry method. The sample digestions were performed in closed microwave vessels with... The contents of Cr, Cu, Ni, As, Cd and Pb in coal fly ash were determined by a high resolution inductively coupled plasma mass spectrometry method. The sample digestions were performed in closed microwave vessels with HNO3, HClO4 and FIE The optimum conditions for the determination were obtained. The applicability of the proposed method was validated by the analysis of coal fly ash reference material (NIST SRM 1633a). The results show that most of the spectral interferences can be avoided by measuring in the high resolution mode (maximum mass resolution R=9 000). The detection limit is from 0.05 to 0.21 μg/g, and the precision is fine with relative standard deviation less than 4.3%. 展开更多
关键词 coal fly ash microwave digestion inductively coupled plasma mass spectrometry DETERMINATION
在线阅读 下载PDF
Trace amounts of impurities in electrolytic manganese metal by sector field inductively coupled plasma mass spectrometry 被引量:3
3
作者 聂西度 梁逸曾 +1 位作者 唐有根 谢华林 《Journal of Central South University》 SCIE EI CAS 2013年第12期3385-3390,共6页
An analytical method, using sector field inductively coupled plasma mass spectrometry (SF-ICP-MS) for rapid simultaneous determination of Be, Na, Mg, Si, Ca, Ti, V, Cr, Fe, Co, Ni, Cu, Zn, As, Sn, Sb, Pb and Bi in e... An analytical method, using sector field inductively coupled plasma mass spectrometry (SF-ICP-MS) for rapid simultaneous determination of Be, Na, Mg, Si, Ca, Ti, V, Cr, Fe, Co, Ni, Cu, Zn, As, Sn, Sb, Pb and Bi in electrolytic manganese metal, was described. At the beginning, the samples were decomposed by HNO3 and H2504, and then analyzed by SF-ICP-MS. Most of the spectral interferences could be avoided by measuring in different mass resolution modes. The matrix effects due to the excess of sulfuric acid and Mn were evaluated. Correction of matrix effects was conducted by using the internal standard elements. The optimum condition for the determination was investigated and discussed. The detection limit is in the range of 0.001-0.169 gg/L. The current method is applied to the determination of trace impurities in electrolytic manganese metal. And experiments show that good results can be obtained much faster, more accurately and conveniently by current method. 展开更多
关键词 sector field inductively coupled plasma mass spectrometry electrolytic manganese IMPURITIES spectral interferences matrix effects
在线阅读 下载PDF
Determination of impurity elements in MnZn ferrites by inductively coupled plasma mass spectrometry 被引量:3
4
作者 张萍 符靓 +1 位作者 马俊才 唐有根 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第1期37-42,共6页
An inductively coupled plasma mass spectrometry(ICP-MS) method was developed for the determination of Na, Mg, Al,K, Ca, Ti, Cr, Co, Ni, Cu, Ga, As, Mo, Ag, Cd and Pb in MnZn ferrites. The sample was digested by HNO3+H... An inductively coupled plasma mass spectrometry(ICP-MS) method was developed for the determination of Na, Mg, Al,K, Ca, Ti, Cr, Co, Ni, Cu, Ga, As, Mo, Ag, Cd and Pb in MnZn ferrites. The sample was digested by HNO3+HCl with microwave digestion followed by dilution with ultrapure water, then the above 16 impurity elements in the solution were analyzed directly by ICP-MS. The impurity elements were introduced by the helium gas or hydrogen gas into the octopole reaction system(ORS) to eliminate the polyatomic interferences caused by the high salty matrixes. The matrix effect was minimized through matrix matching,and Be, Y and Rh were used as internal standard elements. The working parameters of the instrument were optimized. The results show that the method has good precision and high accuracy. The detection limits for the investigated elements are in the range of0.9-37.5 ng/L, the relative standard deviation of each element is within 1.1%-4.8%, and the recovery of each element is 90%-108%. 展开更多
关键词 inductively coupled plasma mass spectrometry(ICP-MS) MnZn ferrites octopole reaction system(ORS) impurity elements
在线阅读 下载PDF
In vivo and in vitro inductively coupled plasma mass spectrometry quantification of minerals and heavy metals in Qishiwei Zhenzhu pill and their effect on intestinal flora
5
作者 FU Ke ZHANG De-wei +9 位作者 SONG Ying-lian XU Min WU Rui-xia XIONG Xue-qing LIU Xian-wu WU Lei GUO Ya ZHOU You LI Xiao-li WANG Zhang 《中国药理学与毒理学杂志》 CAS 北大核心 2021年第10期762-763,共2页
OBJECTIVE Cerebral ischemia or ischemic stroke is due to insufficient blood supply to the brain,which causes hypoxia or ischemia in some areas.This work aimed to quantify the minerals and heavy metals in Qishiwei Zhen... OBJECTIVE Cerebral ischemia or ischemic stroke is due to insufficient blood supply to the brain,which causes hypoxia or ischemia in some areas.This work aimed to quantify the minerals and heavy metals in Qishiwei Zhenzhu pill in vivo and in vitro,analyze its effect on the types and abundance of intestinal flora,and study its mechanism on inflammation and apoptosis pathways as a treatment for cerebral ischemia.METHODS Microwave digestion and inductively coupled plasma mass spectrometry(ICP-MS)were used to determine the minerals and heavy metals in 10 batches of Qishiwei Zhenzhu pill in vitro.With the use of the middle cerebral artery obstruction(MCAO)model,ICP-MS was applied to determine the content of minerals and heavy metals in hepatic portal vein blood,abdominal aortic blood,brain,liver,kidney,hair,urine and feces at different time periods.On this model,the ileum,cecum,and colon tissues were tested for intestinal pathology,and 16S rRNA was used for sequencing.Species taxonomy,αdiversity,and species microbial composition and structure analysis were also performed.Polymerase chain reaction and Western blotting were employed to determine the mRNA and protein expression of p38 MAPK,caspase-3,IL^(-1)βand TNF-αin the ischemic brain tissues of rats.RESULTS The average content of heavy metals in the 10 batches of Qishiwei Zhenzhu pill samples is in the descending order Hg>Cu>Pb.Significant differences in the metal elements are found among Qishiwei Zhenzhu pill from different manufacturers but not among the different batches of the same manufacturer.An extremely low content of heavy metals are absorbed into the blood or accumulated in the brain,liver,kidney,and other tissues.Stool is the main excretion route of minerals and heavy metals from Qishiwei Zhenzhu pill.This medicine helps repair the intestinal mucosa in MCAO rats.At the phylum level,it can regulate the abundance of Firmicutes and Proteobacteria in the intestinal flora of rats with cerebral ischemia.At the genus level,it can adjust the abundance of Escherichia Shigella.At the species level,it can adjust the abundance of Lactobacillus yoelii and Lactobacillus reuteri.Cluster classification results show that Qishiwei Zhenzhu pill can improve the intestinal flora of rats with cerebral ischemia,reduce the mRNA and protein expression of caspase-3 and IL^(-1)βin rat brain tissues,and have a tendency to decrease the mRNA expression of p38 MAPK and TNF-α.CONCLUSION Quantifying the minerals and heavy metals in Qishiwei Zhenzhu pill in vivo and in vitro will help improve their quality standards.Minerals and heavy metals are mainly excreted in feces,accumulate in extremely low levels in various tissues,and do not damage the intestinal mucosa.The effective material basis of Qishiwei Zhenzhu pill in treating cerebral ischemia may be related to their Li,Cr,and Cd elements.These pills can improve the environment of intestinal flora,and their mechanism of treatment for cerebral ischemia may be related to the down-regulation of IL^(-1)βinflammatory factor and inhibition of cell apoptosis. 展开更多
关键词 Qishiwei Zhenzhu pill cerebral ischemia inductively coupled plasma mass spectrometry minerals heavy metals intestinal flora
在线阅读 下载PDF
用电感耦合等离子体质谱法测定中草药中的重金属元素 被引量:14
6
作者 缪恩铭 张艳红 +3 位作者 王森 施红林 陈章玉 杨光宇 《分析测试学报》 CAS CSCD 北大核心 2007年第z1期184-186,共3页
In this paper,the determination of six heavy metal ions (arsenic,lead,cadmium,chromium,mercury and nickel) in the Chinese Herb by inductively coupled plasma-mass spectrometry (ICP-MS) was studied.The samples were dige... In this paper,the determination of six heavy metal ions (arsenic,lead,cadmium,chromium,mercury and nickel) in the Chinese Herb by inductively coupled plasma-mass spectrometry (ICP-MS) was studied.The samples were digested by nitric acid and hydrogen peroxide in a microwave oven.The Sc,Y,In,Bi were added as internal standards to eliminate the matrix interferences.The results show that most of the relative standard deviations of these trace elements were below 3.5%,the standard recoveries of these elements were in the range of 91%-107%,and the detection limits were in the range of 0.001-0.006 μg·L-1. This method is accurate,rapid,convenience,and can be applied to the determination of arsenic,lead,cadmium,chromium,mercury and nickel in Chinese Herb with good results. 展开更多
关键词 Chinese Herb Heavy metal element inductively coupled plasma-mass spectrometry
在线阅读 下载PDF
电感耦合等离子体质谱测定大气铅污染物
7
作者 郑永红 于水 +3 位作者 赵法 宋占军 刘丽萍 郭志英 《分析测试学报》 CAS CSCD 北大核心 2007年第z1期191-192,共2页
Inductively coupled plasma mass spectrometry(ICP-MS) was used to determine the concentration of Pb in atmospheric particulate samples,and the enrichment factor was calculated.The causes of the results were also discus... Inductively coupled plasma mass spectrometry(ICP-MS) was used to determine the concentration of Pb in atmospheric particulate samples,and the enrichment factor was calculated.The causes of the results were also discussed. 展开更多
关键词 inductively coupled plasma mass spectrometry(ICP-MS) Microwave digestion Enrichment factor
在线阅读 下载PDF
Study on the Performance of PECVD Silicon Nitride Thin Films 被引量:4
8
作者 LIU Liang LIU Weiguo +1 位作者 CAO Na CAI Changlong 《Defence Technology(防务技术)》 SCIE EI CAS 2013年第2期152-159,共8页
Mechanical properties and corrosion resistance of Si3N4 films are studied by using different experiment parameters, such as plasma enhanced chemical vapor deposition(PECVD) RF power, ratio of reaction gas, reaction pr... Mechanical properties and corrosion resistance of Si3N4 films are studied by using different experiment parameters, such as plasma enhanced chemical vapor deposition(PECVD) RF power, ratio of reaction gas, reaction pressure and working temperature. The etching process of Si3N4 is studied by inductively coupled plasma (ICP) with a gas mixture of SF6 and O2. The influence of the technique parameters, such as ICP power, DC bias, gas composition, total flow rate, on the etching selectivity of Si3N4/EPG533 which is used as a mask layer and the etching rate of Si3N4 is studied, in order to get a better etching selectivity of Si3N4/EPG533 with a faster etching rate of Si3N4. The optimized process parameters of etching Si3N4 by ICP are obtained after a series of experiments and analysis. Under the conditions of total ICP power of 250 W, DC bias of 50W, total flow rate of 40 sccm and O2 composition of 30%, the etching selectivity of 2.05 can be reached when Si3N4 etching rate is 336 nm/min. 展开更多
关键词 electron technology silicon nitride STRESS inductively coupled plasma etch rate SELECTIVITY
在线阅读 下载PDF
Heavy metals accumulation effect in rabbit body fluids after smoking 被引量:2
9
作者 钟狂飚 桂明 +3 位作者 朱立勇 李维 管茶香 郭方遒 《Journal of Central South University》 SCIE EI CAS 2011年第5期1408-1412,共5页
Concentration of heavy metals in blood and urine of rabbit after inhaling three different kinds of cigarette was studied through the animal passive smoking pattern. The samples were prepared by nitric acid solution di... Concentration of heavy metals in blood and urine of rabbit after inhaling three different kinds of cigarette was studied through the animal passive smoking pattern. The samples were prepared by nitric acid solution digestion and determination of seven kinds of heavy metals including Hg, Se, Sn, Pb, Cd, Ni and Cr was performed by inductively coupled plasma-atomic emission spectrometry (ICP-AES). The ICP-AES method was established with good precision and accuracy, relative standard deviation (n=6) was between 2.9% and 5.9%, and the recovery was in the range of 95.0%-104.2%. Concentration of six heavy metals increases in some extent in blood and urine after period of smoking and the increasing of heavy metals in blood and urine all shows time dependence. Significantly higher heavy metal levels are observed in the blood and urine of the cigarette inhaling rabbits in the exposed group. The concentration of six kinds of heavy metals in the blood of the rabbit increases after 16 weeks exposing to cigarette smoking. Three times of rig, ten times of Se and trace amount ofPb, Cd, Ni and Cr are detected in the blood after 16 weeks of smoking. For urine samples, about three times of Hg, two times of Se, five times of Pb and trace amount of Cd are detected after 16 weeks of inhalation of cigarette. Comparatively, higher concentration of heavy metals are detected after inhaling of Nise cigarette. 展开更多
关键词 inductively coupled plasma-atomic emission spectrometry BLOOD URINE heavy metal element
在线阅读 下载PDF
Simultaneous determination of seven impurities in high-purity cobalt oxide by ICP-AES after matrix separation using 1-nitroso-2-naphthol as a precipitant 被引量:1
10
作者 王艳 周春山 +1 位作者 段青兵 陈萍 《Journal of Central South University of Technology》 2002年第2期100-103,共4页
A method was developed for the simultaneous determination of seven trace impurities (Cd, Mn, Pb, Zn, Cu, Fe and Ni) in high purity cobalt oxide by ICP AES. The matrix effect was eliminated by preci pitation with 1 nit... A method was developed for the simultaneous determination of seven trace impurities (Cd, Mn, Pb, Zn, Cu, Fe and Ni) in high purity cobalt oxide by ICP AES. The matrix effect was eliminated by preci pitation with 1 nitroso 2 naphthol. The matrix effect of cobalt on the absorptions of trace impurities, the effects of reaction time, pH value, dosage of precipitant on the formation of cobalt 1 nitroso 2 naphthol complex, the effects of hydrochloric acid on the stability of this complex and masking of elements were studied. Recoveries of the impurities in spiked sample are from 90% to 110% with a precision of 1.1% 5.0% RSD. The detection limits of the seven elements are in the range of 0.01 0.24μg/g. The method can be applied to the analysis of high purity cobalt metal, cobalt oxide and other cobalt compounds. 展开更多
关键词 trace impurity high purity cobalt oxide matrix separation inductively coupled plasma atomic emission spectrometry (ICP AES)
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部