The contents ofMg, Al, Si, Ti, Cr, Mn, Fe, Co, Cu, Ga, As, Se, Cd, Sb, Pb and Bi in high purity nickel were determined by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). The sample was diss...The contents ofMg, Al, Si, Ti, Cr, Mn, Fe, Co, Cu, Ga, As, Se, Cd, Sb, Pb and Bi in high purity nickel were determined by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). The sample was dissolved in HNO3 and HCI by microwave digestion. Most of the spectral interferences could be avoided by measuring in the high resolution mode. The matrix effects because of the presence of excess HC1 and nickel were evaluated. Correction for matrix effects was made using Sc, Rh and T1 as internal standards. The optimum conditions for the determination were tested and discussed. The detection limits range from 0.012 to 1.76 ~tg/g depending on the type of elements. The applicability of the proposed method is also validated by the analysis of high purity nickel reference material (NIST SRM 671). The relative standard deviation (RSD) is less than 3.3%. Results for determination of trace elements in high purity nickel were presented.展开更多
目的采用超高效液相色谱-四极杆/静电场轨道阱高分辨质谱(ultra-high performance liquid chromatography-quadrupole/electrostatic field orbitrap high resolution mass spectrometry,UPLC-Q/Orbitrap HRMS)技术建立全血中60种天然...目的采用超高效液相色谱-四极杆/静电场轨道阱高分辨质谱(ultra-high performance liquid chromatography-quadrupole/electrostatic field orbitrap high resolution mass spectrometry,UPLC-Q/Orbitrap HRMS)技术建立全血中60种天然毒素的快速筛查方法。方法分析并记录60种天然毒素标准品的色谱和质谱信息,构建筛查数据库。全血用蛋白沉淀法配合超声辅助分散进行前处理,使用Hypersil GOLD^(TM)C_(18)色谱柱,以5 mmol/L甲酸铵水溶液(含0.1%甲酸)和乙腈为流动相进行梯度洗脱,在电喷雾电离正离子模式和全扫描/数据依赖二级扫描(Full MS/dd-MS^(2))模式下检测。基于构建的筛查数据库,采用TraceFinder软件实现全血中60种天然毒素的快速筛查。结果建立的全血中60种天然毒素的UPLC-Q/Orbitrap HRMS筛查方法,除氧化苦参碱(LOD为20ng/mL)和毒毛旋花子苷元(LOD为40ng/mL)外,其余58种天然毒素的LOD范围为0.05~5 ng/mL。结论该方法前处理简单、高效,可以实现对全血中60种天然毒素的快速筛查。展开更多
A rapid pretreatment method of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in soil and analysis by high resolution gas chromatograph-high resolution mass spectrometry was present.The extraction and a...A rapid pretreatment method of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in soil and analysis by high resolution gas chromatograph-high resolution mass spectrometry was present.The extraction and alumina clean up of PCDD/Fs in soil was achieved by accelerated solvent extractor.Then the multi-layer silica-gel column was used for further clean up.The whole method has been evaluated on certified reference soil and farm soil.Accuracy and precision of this method was tested with satisfactory results.展开更多
基金Project(21075138) supported by the National Natural Science Foundation of ChinaProject(cstc2011jjA0780) supported by Natural Science Foundation of Chongqing City,ChinaProject(KJ121311) supported by Educational Commission of Chongqing City of China
文摘The contents ofMg, Al, Si, Ti, Cr, Mn, Fe, Co, Cu, Ga, As, Se, Cd, Sb, Pb and Bi in high purity nickel were determined by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). The sample was dissolved in HNO3 and HCI by microwave digestion. Most of the spectral interferences could be avoided by measuring in the high resolution mode. The matrix effects because of the presence of excess HC1 and nickel were evaluated. Correction for matrix effects was made using Sc, Rh and T1 as internal standards. The optimum conditions for the determination were tested and discussed. The detection limits range from 0.012 to 1.76 ~tg/g depending on the type of elements. The applicability of the proposed method is also validated by the analysis of high purity nickel reference material (NIST SRM 671). The relative standard deviation (RSD) is less than 3.3%. Results for determination of trace elements in high purity nickel were presented.
文摘A rapid pretreatment method of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in soil and analysis by high resolution gas chromatograph-high resolution mass spectrometry was present.The extraction and alumina clean up of PCDD/Fs in soil was achieved by accelerated solvent extractor.Then the multi-layer silica-gel column was used for further clean up.The whole method has been evaluated on certified reference soil and farm soil.Accuracy and precision of this method was tested with satisfactory results.