An input-output signal selection based on Phillips-Heffron model of a parallel high voltage alternative current/high voltage direct current(HVAC/HVDC) power system is presented to study power system stability. It is w...An input-output signal selection based on Phillips-Heffron model of a parallel high voltage alternative current/high voltage direct current(HVAC/HVDC) power system is presented to study power system stability. It is well known that appropriate coupling of inputs-outputs signals in the multivariable HVDC-HVAC system can improve the performance of designed supplemetary controller. In this work, different analysis techniques are used to measure controllability and observability of electromechanical oscillation mode. Also inputs–outputs interactions are considered and suggestions are drawn to select the best signal pair through the system inputs-outputs. In addition, a supplementary online adaptive controller for nonlinear HVDC to damp low frequency oscillations in a weakly connected system is proposed. The results obtained using MATLAB software show that the best output-input for damping controller design is rotor speed deviation as out put and phase angle of rectifier as in put. Also response of system equipped with adaptive damping controller based on HVDC system has appropriate performance when it is faced with faults and disturbance.展开更多
The total electric field(TEF) at ground level induced by high-voltage direct current(HVDC) overhead transmission lines is one of the important indexes for evaluating the lines' electromagnetic environment.Based on...The total electric field(TEF) at ground level induced by high-voltage direct current(HVDC) overhead transmission lines is one of the important indexes for evaluating the lines' electromagnetic environment.Based on analyzing the existing TEF sensors and the measurement principle of ion-current density,the influence from ions on TEF measurements is quantitively studied.The results show that the ions generated by the corona from a HVDC transmission line in operation cause errors in the measurement of TEF.This error is determined through analyzing the component of total measuring current on the filed mill's sensing electrode: if no appropriate approach taken,the maximum measurement error reaches up to 4.3%.Furthermore,a method that can eliminate such error,and hence improve the accuracy of TEF sensors is designed.展开更多
More and more applications of ZnO arrester in electrical system experienced more problems.One thing,that is still under some investigation,is the effect of multiple lightning strike to the performance of ZnO arrester....More and more applications of ZnO arrester in electrical system experienced more problems.One thing,that is still under some investigation,is the effect of multiple lightning strike to the performance of ZnO arrester.As we know,the design of ZnO arrester for transmission system and for distribution system differs in the point of view of the number of ZnO blocks.Transmission system,due to its higher nominal voltage than distribution system,has more numbers of ZnO blocks inside an arrester tube.In term of the current rating of an arrester,it is found that there is some different value of the current rating.The current rating of an arrester installed closer to electrical substation is higher than that of some further away from the substation.To the respond of a lightning impulse strike,the arrester will let a high value of impulse current flowing.It tends to heat the ZnO material of the arrester.If the number of impulse strike is quite high then it may give the effect to the change of the arrester performance.This condition will endanger the equipment that is protected by the arrester from lightning strikes.During this research,the scope of work is limited to making an impulse current generator toward to one having 8/20 μs wave-shape.This kind of impulse current wave-shape is the one that is used for studying the performance of ZnO block.The effect of the inductance and capacitance of the impulse current generator were also studied.A 10 fused cut out was blown by an impulse having 10321 A of 17.8/37.8 μs.A ZnO arrester block brokendown/allowed large value of current :10982 A flowing under the voltage of 10.5展开更多
There are the application scope limits for single differential-mode current injection test method, so in order to carry out injection susceptibility test for two-pieces equipment interconnected with both ends of a cab...There are the application scope limits for single differential-mode current injection test method, so in order to carry out injection susceptibility test for two-pieces equipment interconnected with both ends of a cable simultaneously, a double differential-mode current in- jection test method (DDMCI) is proposed. The method adopted the equivalence source wave theorem and Baum-Liu-Tesche(BLT) equation as its theory foundation. The equivalent corresponding relation between injection voltage and radiation electric field intensity is derived, and the phase relation between the two injection voltage sources is confirmed. The results indicate that the amplitude and phase of the equivalent injection voltage source is closely related to the S parameter of directional coupling device, the transmission line length, and the source vector in BLT equation, but has nothing to do with the reflection coefficient between the two equipment pieces. Therefore, by choosing the right amplitude and phase of the double injection voltage sources, the DDMCI test is equivalent to the radiation test for two interconnected equipment of a system.展开更多
文摘An input-output signal selection based on Phillips-Heffron model of a parallel high voltage alternative current/high voltage direct current(HVAC/HVDC) power system is presented to study power system stability. It is well known that appropriate coupling of inputs-outputs signals in the multivariable HVDC-HVAC system can improve the performance of designed supplemetary controller. In this work, different analysis techniques are used to measure controllability and observability of electromechanical oscillation mode. Also inputs–outputs interactions are considered and suggestions are drawn to select the best signal pair through the system inputs-outputs. In addition, a supplementary online adaptive controller for nonlinear HVDC to damp low frequency oscillations in a weakly connected system is proposed. The results obtained using MATLAB software show that the best output-input for damping controller design is rotor speed deviation as out put and phase angle of rectifier as in put. Also response of system equipped with adaptive damping controller based on HVDC system has appropriate performance when it is faced with faults and disturbance.
基金Project supported by National Natural Science Foundation of China (61273165 51207005).
文摘The total electric field(TEF) at ground level induced by high-voltage direct current(HVDC) overhead transmission lines is one of the important indexes for evaluating the lines' electromagnetic environment.Based on analyzing the existing TEF sensors and the measurement principle of ion-current density,the influence from ions on TEF measurements is quantitively studied.The results show that the ions generated by the corona from a HVDC transmission line in operation cause errors in the measurement of TEF.This error is determined through analyzing the component of total measuring current on the filed mill's sensing electrode: if no appropriate approach taken,the maximum measurement error reaches up to 4.3%.Furthermore,a method that can eliminate such error,and hence improve the accuracy of TEF sensors is designed.
文摘More and more applications of ZnO arrester in electrical system experienced more problems.One thing,that is still under some investigation,is the effect of multiple lightning strike to the performance of ZnO arrester.As we know,the design of ZnO arrester for transmission system and for distribution system differs in the point of view of the number of ZnO blocks.Transmission system,due to its higher nominal voltage than distribution system,has more numbers of ZnO blocks inside an arrester tube.In term of the current rating of an arrester,it is found that there is some different value of the current rating.The current rating of an arrester installed closer to electrical substation is higher than that of some further away from the substation.To the respond of a lightning impulse strike,the arrester will let a high value of impulse current flowing.It tends to heat the ZnO material of the arrester.If the number of impulse strike is quite high then it may give the effect to the change of the arrester performance.This condition will endanger the equipment that is protected by the arrester from lightning strikes.During this research,the scope of work is limited to making an impulse current generator toward to one having 8/20 μs wave-shape.This kind of impulse current wave-shape is the one that is used for studying the performance of ZnO block.The effect of the inductance and capacitance of the impulse current generator were also studied.A 10 fused cut out was blown by an impulse having 10321 A of 17.8/37.8 μs.A ZnO arrester block brokendown/allowed large value of current :10982 A flowing under the voltage of 10.5
基金Project supported by Arm Pre-research Program (51333040101), National Defense 973 Program (6131380301 ), National Natural Science Foundation of China (61040003).
文摘There are the application scope limits for single differential-mode current injection test method, so in order to carry out injection susceptibility test for two-pieces equipment interconnected with both ends of a cable simultaneously, a double differential-mode current in- jection test method (DDMCI) is proposed. The method adopted the equivalence source wave theorem and Baum-Liu-Tesche(BLT) equation as its theory foundation. The equivalent corresponding relation between injection voltage and radiation electric field intensity is derived, and the phase relation between the two injection voltage sources is confirmed. The results indicate that the amplitude and phase of the equivalent injection voltage source is closely related to the S parameter of directional coupling device, the transmission line length, and the source vector in BLT equation, but has nothing to do with the reflection coefficient between the two equipment pieces. Therefore, by choosing the right amplitude and phase of the double injection voltage sources, the DDMCI test is equivalent to the radiation test for two interconnected equipment of a system.