采用顶空固相微萃取(headspace solid-phase microextraction,HS-SPME)和液液萃取(liquid-liquid extraction,LLE)结合全二维气相色谱飞行时间质谱(comprehensive two-dimensional gas chromatography time of flight mass spectrometry...采用顶空固相微萃取(headspace solid-phase microextraction,HS-SPME)和液液萃取(liquid-liquid extraction,LLE)结合全二维气相色谱飞行时间质谱(comprehensive two-dimensional gas chromatography time of flight mass spectrometry,GC×GC-TOF-MS)以及香气活度值(odour active value,OAV),对红星二锅头白酒的挥发性成分进行全面解析。研究发现,HS-SPME、LLE分别定性出928、802种挥发性化合物,共计定性出1304种挥发性化合物,共同定性出426种挥发性化合物。基于HS-SPME数据,通过香气数据库筛选出具有香气特征的382种香气化合物,其中酯类相对百分含量占比最高,其次是醇类、酸类和醛类。计算得到了49种香气化合物OAV>1,其中酯类(辛酸乙酯、异戊酸乙酯等)和萜烯类(β-大马酮)对白酒风味的贡献最大,醛类(异戊醛、己醛等)和含硫类(二甲基三硫)其次,醇类(1-辛烯-3-醇)和含氮类(2,3,5-三甲基吡嗪)也有一定风味贡献。该研究丰富了红星二锅头白酒的风味研究,也为下一步生产研究及调控提供了理论和数据支撑。展开更多
Eight fatty acids from beaver oil were identified by GC-9A, and their contents were determinded. A simple yet effective method for separation and quantification was described. Contents of the fatty acids were related ...Eight fatty acids from beaver oil were identified by GC-9A, and their contents were determinded. A simple yet effective method for separation and quantification was described. Contents of the fatty acids were related to their conditions of extraction.展开更多
Long-term indoor-air limit for formaldehyde stipulated by the European Commission is 1 μg/m3,while the World Health Organization has set a threshold of 100 μg/m3 that should not be exceeded for more than 30 min. To ...Long-term indoor-air limit for formaldehyde stipulated by the European Commission is 1 μg/m3,while the World Health Organization has set a threshold of 100 μg/m3 that should not be exceeded for more than 30 min. To date,however,only a few analytical techniques have been developed that can be used to detect formaldehyde at these very restrictive limits. Thus,there is a need to develop for comprehensive methods for analyzing airborne formaldehyde and other carbonyl pollutants in the ambient environment. The aim of this study is to develop a highly sensitive online automated preconcentration gas chromatographic method using large-volume injection with a programmed temperature vaporization injector for the analysis of airborne formaldehyde and ten other carbonyl compounds. The influence of several parameters,such as the maximum volume injected,programmed temperature vaporization transfer time and temperature,carrier gas flow rate,and type of packing material was investigated. After optimization,highly satisfactory results in terms of the absolute and methodological detection limits were achieved,i. e. as low as the μg/m3 level for all the carbonyl pollutants studied. A commercially available sampler,originally designed for active sampling,was evaluated as a passive sampling device;this optimized technique was applied to monitor the concentrations of carbonyl pollutants in the indoor air of ten public buildings in Florence. The strength of this methodology lies both in the low detection limits reached in the simultaneous analysis of a wide group of 2,4-dinitrophenylhydrazine derivatives,and the potential adaptability of this method to other gas chromatographic applications to achieve lower sensitivity.展开更多
Poly(ether ether ketone)(PEEK)was synthesized via polycondensation of hydroquinone with 4,4′-difluorobenzophenone at 320℃for 5 h.Thermal and thermo-oxidative degradation of PEEK was studied over a wide range of temp...Poly(ether ether ketone)(PEEK)was synthesized via polycondensation of hydroquinone with 4,4′-difluorobenzophenone at 320℃for 5 h.Thermal and thermo-oxidative degradation of PEEK was studied over a wide range of temperatures.In an inert medium,decomposition of the polymer occurred in one stage,with the formation of a coke residue accounting for approximately 50%of the original polymer mass.In air,the mass loss curve exhibited two distinct stages.The first stage involved breakdown of the main polymer chain,the speed of which indicated a radical chain failure mechanism.In the second stage,the rate of mass loss clearly decreased,indicating a transition from the radical chain failure mechanism to simple combustion reactions(wherein the polymer combusted completely).To further investigate the nature of the processes occurring during the pyrolysis of PEEK,the investigations were carried out using gas chromatograph under isothermal conditions.It was concluded that during thermal degradation,the decomposition of the polymer starts with the rupture of ketone and ether bonds and proceeds to destruction of the benzene ring at higher temperatures,which is accompanied by the formation of H2O and CH4.Above 500℃,the polymer degradation further involved thermohydrolysis.The thermo-oxidation of PEEK,which was accompanied mainly by the formation ofH2,was noticeable beginning at 325℃.The total yield of the latter indicated oxidation of fragments of the benzene ring.展开更多
The detector,as well as being an essential supporting device for the gas chromatography(GC) has also played a critical role in the development of the technique as a whole.The mass spectrometer(MS) is still the commonl...The detector,as well as being an essential supporting device for the gas chromatography(GC) has also played a critical role in the development of the technique as a whole.The mass spectrometer(MS) is still the commonly praised detector as before.In fact,the information of fragmentation patterns is seldom used in practice,and the GC-MS instrument is even more expensive.For today's analytical problems,it seems that element specific detectors can and should be used for many applications rather than GC-MS.展开更多
文摘采用顶空固相微萃取(headspace solid-phase microextraction,HS-SPME)和液液萃取(liquid-liquid extraction,LLE)结合全二维气相色谱飞行时间质谱(comprehensive two-dimensional gas chromatography time of flight mass spectrometry,GC×GC-TOF-MS)以及香气活度值(odour active value,OAV),对红星二锅头白酒的挥发性成分进行全面解析。研究发现,HS-SPME、LLE分别定性出928、802种挥发性化合物,共计定性出1304种挥发性化合物,共同定性出426种挥发性化合物。基于HS-SPME数据,通过香气数据库筛选出具有香气特征的382种香气化合物,其中酯类相对百分含量占比最高,其次是醇类、酸类和醛类。计算得到了49种香气化合物OAV>1,其中酯类(辛酸乙酯、异戊酸乙酯等)和萜烯类(β-大马酮)对白酒风味的贡献最大,醛类(异戊醛、己醛等)和含硫类(二甲基三硫)其次,醇类(1-辛烯-3-醇)和含氮类(2,3,5-三甲基吡嗪)也有一定风味贡献。该研究丰富了红星二锅头白酒的风味研究,也为下一步生产研究及调控提供了理论和数据支撑。
文摘Eight fatty acids from beaver oil were identified by GC-9A, and their contents were determinded. A simple yet effective method for separation and quantification was described. Contents of the fatty acids were related to their conditions of extraction.
文摘Long-term indoor-air limit for formaldehyde stipulated by the European Commission is 1 μg/m3,while the World Health Organization has set a threshold of 100 μg/m3 that should not be exceeded for more than 30 min. To date,however,only a few analytical techniques have been developed that can be used to detect formaldehyde at these very restrictive limits. Thus,there is a need to develop for comprehensive methods for analyzing airborne formaldehyde and other carbonyl pollutants in the ambient environment. The aim of this study is to develop a highly sensitive online automated preconcentration gas chromatographic method using large-volume injection with a programmed temperature vaporization injector for the analysis of airborne formaldehyde and ten other carbonyl compounds. The influence of several parameters,such as the maximum volume injected,programmed temperature vaporization transfer time and temperature,carrier gas flow rate,and type of packing material was investigated. After optimization,highly satisfactory results in terms of the absolute and methodological detection limits were achieved,i. e. as low as the μg/m3 level for all the carbonyl pollutants studied. A commercially available sampler,originally designed for active sampling,was evaluated as a passive sampling device;this optimized technique was applied to monitor the concentrations of carbonyl pollutants in the indoor air of ten public buildings in Florence. The strength of this methodology lies both in the low detection limits reached in the simultaneous analysis of a wide group of 2,4-dinitrophenylhydrazine derivatives,and the potential adaptability of this method to other gas chromatographic applications to achieve lower sensitivity.
基金supported by the Ministry of Education and Science of the Russian Federation(Identifier number:RFMEFI57717X0240)
文摘Poly(ether ether ketone)(PEEK)was synthesized via polycondensation of hydroquinone with 4,4′-difluorobenzophenone at 320℃for 5 h.Thermal and thermo-oxidative degradation of PEEK was studied over a wide range of temperatures.In an inert medium,decomposition of the polymer occurred in one stage,with the formation of a coke residue accounting for approximately 50%of the original polymer mass.In air,the mass loss curve exhibited two distinct stages.The first stage involved breakdown of the main polymer chain,the speed of which indicated a radical chain failure mechanism.In the second stage,the rate of mass loss clearly decreased,indicating a transition from the radical chain failure mechanism to simple combustion reactions(wherein the polymer combusted completely).To further investigate the nature of the processes occurring during the pyrolysis of PEEK,the investigations were carried out using gas chromatograph under isothermal conditions.It was concluded that during thermal degradation,the decomposition of the polymer starts with the rupture of ketone and ether bonds and proceeds to destruction of the benzene ring at higher temperatures,which is accompanied by the formation of H2O and CH4.Above 500℃,the polymer degradation further involved thermohydrolysis.The thermo-oxidation of PEEK,which was accompanied mainly by the formation ofH2,was noticeable beginning at 325℃.The total yield of the latter indicated oxidation of fragments of the benzene ring.
文摘The detector,as well as being an essential supporting device for the gas chromatography(GC) has also played a critical role in the development of the technique as a whole.The mass spectrometer(MS) is still the commonly praised detector as before.In fact,the information of fragmentation patterns is seldom used in practice,and the GC-MS instrument is even more expensive.For today's analytical problems,it seems that element specific detectors can and should be used for many applications rather than GC-MS.