期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Mechanical behavior and deformation mechanism of ballast bed with various fouling materials 被引量:9
1
作者 ZHANG Zhi-hai XIAO Hong +2 位作者 WANG Meng LIU Guang-peng WANG Hao-yu 《Journal of Central South University》 SCIE EI CAS CSCD 2021年第9期2857-2874,共18页
In order to study the interaction between various fouling particles and ballast,a multi-layer and multi-scale discrete element model(DEM)including the sleeper,ballast bed and the surface layer of subgrade was develope... In order to study the interaction between various fouling particles and ballast,a multi-layer and multi-scale discrete element model(DEM)including the sleeper,ballast bed and the surface layer of subgrade was developed.Two typical fouling particles,the hard particles(sand)and soft ones(coal fines),are considered.A support stiffness test of the ballast bed under various fouling conditions was conducted to calibrate the microscopic parameters of the contact model.With the model,the influence of fouling particles on the mechanical behavior and deformation of the ballast bed was analyzed from macro and micro perspectives.The results show that the increase in the strength of the fouling particles enlarges the stiffness of the ballast bed.Hard particles increase the uniformity coefficient of the contact force bondγof ballast by 50.4%.Fouling particles increase the average stress in the subgrade,soft particles by 2 kPa and hard particles by 1 kPa.Hard particles can reduce the elasticity,plastic deformation and energy dissipation in the track structure.As the fouling particle changes from hard to soft,the proportion of the settlement in ballast bed increases to 40.5%and surface layer of swbgrade settlement decreases to 59.5%.Thus,the influence of fouling particles should be considered carefully in railway design and maintenance. 展开更多
关键词 ballasted track fouling material discrete element method contact force bond elastic-plastic deformation
在线阅读 下载PDF
Discrete element method analysis of lateral resistance of fouled ballast bed 被引量:4
2
作者 XU Yang 《Journal of Central South University》 SCIE EI CAS CSCD 2016年第9期2373-2381,共9页
The lateral resistance of sleeper plays an important role in ensuring the stability of a railway track, which may change in the operation of railway, due to the fouling in the ballast bed. In this work, discrete eleme... The lateral resistance of sleeper plays an important role in ensuring the stability of a railway track, which may change in the operation of railway, due to the fouling in the ballast bed. In this work, discrete element method was adopted to investigate the effect of fouling on the lateral resistance of sleeper. The shape information of ballast was captured by method of three-dimensional vision reconstruction. In order to calibrate the mechanical parameters and verify the models, a lateral resistance field test was carried out by using a custom-made device. The contact force distributions in the different parts of sleeper as well as the interaction between ballast and sleeper were discussed in depth. The results show that fouling of ballast bed evidently reduces the lateral resistance of sleeper and the decreasing degree is also related to the fouled position of ballast bed, in the order of shoulder > bottom > side.Therefore, the effect of fouling, especially the fouling in the ballast shoulder, on the lateral resistance of sleeper, should be taken into account in ballast track maintenance work. 展开更多
关键词 discrete element modelling three-dimensional vision reconstruction BALLAST lateral resistance of sleeper ballast fouling
在线阅读 下载PDF
Analysis of influence of heat exchangerfouling on heat transfer performancebased on thermal fluid coupling 被引量:1
3
作者 HUANG Si MURAD Tariq +2 位作者 NIU Qifeng LIN Guangtang CHEN Jianxun 《排灌机械工程学报》 CSCD 北大核心 2023年第7期695-700,共6页
A study on heat transfer performance by thermal fluid coupling simulation for the fouling in a shell-tube heat exchanger used in engineering was presented. The coupling simulation was performed in a fluid and solid do... A study on heat transfer performance by thermal fluid coupling simulation for the fouling in a shell-tube heat exchanger used in engineering was presented. The coupling simulation was performed in a fluid and solid domains under three different fouling conditions: fouling inside the tube, fouling outside the tube, and fouling inside the shell. The flow field, temperature, and pressure distributions in the heat exchanger were solved numerically to analyze the heat transfer performance parameters, such as thermal resistance. It is found that the pressure drop of the heat exchanger and the thermal resistance of the tube wall increase by nearly 30% and 20%, respectively, when the relative fouling thickness reaches 10%. The fouling inside the tube has more impact on the heat transfer performance of the heat exchanger, and the fouling inside the shell has less impact. 展开更多
关键词 shell-tube heat exchanger thermal fluid coupling fouling thermal resistance heat transfer analysis
在线阅读 下载PDF
Measurement Methodology for Monitoring Fouling Resistance in Condenser of Chiller
4
作者 YU Dan1,3,GAN Li-si1,CAO Yong2(1.Beijing University of Technology,Beijing 100022,China 2.Build Environment and Energy Efficiency,China Academy of Building Research,Beijing 100013,China 3.Beijing Institute of Civil Engineering and Architecture,Beijing 100044,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期119-122,共4页
This paper established an on-line monitoring model for fouling resistance of cooling water based on heat transfer theory,which was mainly applied to the fouling resistance test for condenser of chiller in operation,an... This paper established an on-line monitoring model for fouling resistance of cooling water based on heat transfer theory,which was mainly applied to the fouling resistance test for condenser of chiller in operation,and the test requirements were presented.It proves that the load ratio of chiller has big influence on the test result,and the best load ratio for test is the range of 80%~100%.A case has been executed to validate the model's feasibility. 展开更多
关键词 FOULING resistance MONITORING CONDENSER COOLING water
在线阅读 下载PDF
Preface:Corrosion and protection in marine environment
5
作者 ZHANG Bin-bin ZHANG Rui-yong +2 位作者 WANG Yi WANG Wei SAND Wolfgang 《Journal of Central South University》 SCIE EI CAS CSCD 2024年第10期3349-3351,共3页
The development of the marine economy,the protection of maritime rights,and the construction of a maritime power all rely on the support of various marine engineering facilities and equipment.However,when materials ar... The development of the marine economy,the protection of maritime rights,and the construction of a maritime power all rely on the support of various marine engineering facilities and equipment.However,when materials are used in marine environments,they face various issues of corrosion and biofouling.The occurrence of these problems not only significantly impacts the performance of materials but can also lead to substantial economic losses and even catastrophic or sudden safety incidents.Therefore,corrosion and prevention of various materials used in marine environments have always been challenging issues faced by researchers and engineering professionals.A deep understanding of the marine corrosion mechanisms of various materials,as well as the design and development of materials and technologies with excellent anti-corrosion properties,are the focal points and hot topics of interest for researchers in this field. 展开更多
关键词 CORROSION CORROSION FOULING
在线阅读 下载PDF
Negative Effects of Sludge Bulking in Membrane Bio-Reactor
6
作者 ZHANG Ying HUANG Zhi +1 位作者 REN Nanqi MENG Qingjuan 《Journal of Northeast Agricultural University(English Edition)》 CAS 2006年第2期153-156,共4页
Sludge bulking property of membrane bio-reactor was investigated in this study through contrast research. When the sludge bulking appeared, the removal efficiency of COD in membrane bio-reactor increased slightly thro... Sludge bulking property of membrane bio-reactor was investigated in this study through contrast research. When the sludge bulking appeared, the removal efficiency of COD in membrane bio-reactor increased slightly through the function of filamentous bacteria. However, the negative effects of the higher net water-head differential pressures, the high block rate of membrane pore and the great quantity of filamentous bacteria at the external surface presented at the same time. Thus, plenty of methods should be performed to control sludge bulking once it happened in membrane bio-reactor. 展开更多
关键词 membrane bio-reactor sludge bulking property membrane fouling
在线阅读 下载PDF
上一页 1 下一页 到第