Image restoration phase-filtering lateral superresolution confocal microscopy, a new approach, is proposed to achieve lateral superresolution using a confoeal microscope. This approach uses a lateral superresolution p...Image restoration phase-filtering lateral superresolution confocal microscopy, a new approach, is proposed to achieve lateral superresolution using a confoeal microscope. This approach uses a lateral superresolution pupil filter to preliminarily improve its lateral resolution and uses a siagle-image superresolution restoration technique based on a maximum likelihood estimate to further improve its lateral resolution. The new approach has the advantages of a low cost and the remarkable superresolution effect without excessive system complexity. Experiments indicate that the proposed approach can improve the lateral resolution of a confocal microscope from 0.3μm to less than 0.1 μm when λ = 632.8 nm and NA=0.85.展开更多
A critical function of flow cytometry is to count the concentration of blood cells,which helps in the diagnosis of certain diseases.However,the bulky nature of commercial flow cytometers makes such tests only availabl...A critical function of flow cytometry is to count the concentration of blood cells,which helps in the diagnosis of certain diseases.However,the bulky nature of commercial flow cytometers makes such tests only available in hospitals or laboratories,hindering the spread of point-of-care testing(POCT),especially in underdeveloped areas.Here,we propose a smart Palm-size Optofluidic Hematology Analyzer based on a miniature fluorescence microscope and a microfluidic platform to lighten the device to improve its portability.This gadget has a dimension of 35×30×80 mm and a mass of 39 g,less than 5%of the weight of commercially available flow cytometers.Additionally,automatic leukocyte concentration detection has been realized through the integration of image processing and leukocyte counting algorithms.We compared the leukocyte concentration measurement between our approach and a hemocytometer using the Passing-Bablok analysis and achieved a correlation coefficient of 0.979.Through Bland-Altman analysis,we obtained the relationship between their differences and mean measurement values and established 95%limits of agreement,ranging from−0.93×10^(3)to 0.94×10^(3)cells/μL.We anticipate that this device can be used widely for monitoring and treating diseases such as HIV and tumors beyond hospitals.展开更多
基金Supported by the National Natural Science Foundation of China under Grant No 50475035, and the Research Fund for the Doctoral Programme of Higher Education of China under Grant No 20050213035.
文摘Image restoration phase-filtering lateral superresolution confocal microscopy, a new approach, is proposed to achieve lateral superresolution using a confoeal microscope. This approach uses a lateral superresolution pupil filter to preliminarily improve its lateral resolution and uses a siagle-image superresolution restoration technique based on a maximum likelihood estimate to further improve its lateral resolution. The new approach has the advantages of a low cost and the remarkable superresolution effect without excessive system complexity. Experiments indicate that the proposed approach can improve the lateral resolution of a confocal microscope from 0.3μm to less than 0.1 μm when λ = 632.8 nm and NA=0.85.
基金supported by the National Natural Science Foundation of China (grant no.62305083 to W.Z.,grant no.T2222009 to H.L.,grant no.32227802 to H.L.)China Postdoctoral Science Foundation (grant no.2023T160163 to W.Z.grant no.2022M720971 to W.Z.)+2 种基金the Heilongjiang Provincial Postdoctoral Science Foundation (grant no.LBH-Z22027 to W.Z.)the National Key Research and Development Program of China (grant no.2022YFC3400600 to H.L.)the Natural Science Foundation of Heilongjiang Province (grant no.YQ2021F013 to H.L.).
文摘A critical function of flow cytometry is to count the concentration of blood cells,which helps in the diagnosis of certain diseases.However,the bulky nature of commercial flow cytometers makes such tests only available in hospitals or laboratories,hindering the spread of point-of-care testing(POCT),especially in underdeveloped areas.Here,we propose a smart Palm-size Optofluidic Hematology Analyzer based on a miniature fluorescence microscope and a microfluidic platform to lighten the device to improve its portability.This gadget has a dimension of 35×30×80 mm and a mass of 39 g,less than 5%of the weight of commercially available flow cytometers.Additionally,automatic leukocyte concentration detection has been realized through the integration of image processing and leukocyte counting algorithms.We compared the leukocyte concentration measurement between our approach and a hemocytometer using the Passing-Bablok analysis and achieved a correlation coefficient of 0.979.Through Bland-Altman analysis,we obtained the relationship between their differences and mean measurement values and established 95%limits of agreement,ranging from−0.93×10^(3)to 0.94×10^(3)cells/μL.We anticipate that this device can be used widely for monitoring and treating diseases such as HIV and tumors beyond hospitals.