The application of a thermoluminescent detector(TLD) for dose detection at the liver irradiation site in mice under linear accelerator precision radiotherapy and the use of a single high dose to irradiate the mouse li...The application of a thermoluminescent detector(TLD) for dose detection at the liver irradiation site in mice under linear accelerator precision radiotherapy and the use of a single high dose to irradiate the mouse liver to construct a biological model of a radiation-induced liver injury(RILD) in mice were to determine the feasibility of constructing a precision radiotherapy model in small animals under a linear accelerator. A 360° arc volumetric rotational intensity-modulated radiotherapy(VMAT) plan with a prescribed dose of 2 Gy was developed for the planned target volume(PTV) at the location of the TLD within solid water to compare the difference between the measured dose of TLD and the assessed parameters in the TPS system. The TLD was implanted in the livers of mice, and VMAT was planned based on TLD to compare the measured and prescribed doses. C57BL/6 J mice were randomly divided into control and 25-Gy radiation groups and were examined daily for changes in body weight. They were euthanized at 3 and 10 weeks after radiation, and the levels of liver serum enzymes such as alanine aminotransferase(ALT), aspartate aminotransferase(AST), and alkaline phosphatase(ALP) were measured to observe any pathological histological changes in the irradiated areas of the mouse liver. The measured values of solid underwater TLD were within ± 3% of the Dmean value of the evaluation parameter in the TPS system. The mice in the 25-Gy radiation group demonstrated pathological signs of radiation-induced liver injury at the site of liver irradiation. The deviation in the measured and prescribed doses of TLD in the mouse liver ranged from-1.5 to 6%;construction of an accurate model of RILD using the VMAT technique under a linear accelerator is feasible.展开更多
Intensity-modulated particle therapy(IMPT)with carbon ions is comparatively susceptible to various uncertainties caused by breathing motion,including range,setup,and target positioning uncertainties.To determine relat...Intensity-modulated particle therapy(IMPT)with carbon ions is comparatively susceptible to various uncertainties caused by breathing motion,including range,setup,and target positioning uncertainties.To determine relative biological effectiveness-weighted dose(RWD)distributions that are resilient to these uncertainties,the reference phase-based four-dimensional(4D)robust optimization(RP-4DRO)and each phase-based 4D robust optimization(EP-4DRO)method in carbon-ion IMPT treatment planning were evaluated and compared.Based on RWD distributions,4DRO methods were compared with 4D conventional optimization using planning target volume(PTV)margins(PTV-based optimization)to assess the effectiveness of the robust optimization methods.Carbon-ion IMPT treatment planning was conducted in a cohort of five lung cancer patients.The results indicated that the EP-4DRO method provided better robustness(P=0.080)and improved plan quality(P=0.225)for the clinical target volume(CTV)in the individual respiratory phase when compared with the PTV-based optimization.Compared with the PTV-based optimization,the RP-4DRO method ensured the robustness(P=0.022)of the dose distributions in the reference breathing phase,albeit with a slight sacrifice of the target coverage(P=0.450).Both 4DRO methods successfully maintained the doses delivered to the organs at risk(OARs)below tolerable levels,which were lower than the doses in the PTV-based optimization(P<0.05).Furthermore,the RP-4DRO method exhibited significantly superior performance when compared with the EP-4DRO method in enhancing overall OAR sparing in either the individual respiratory phase or reference respiratory phase(P<0.05).In general,both 4DRO methods outperformed the PTV-based optimization in terms of OAR sparing and robustness.展开更多
基金supported by the Natural Science Foundation of Anhui Province (No.2208085MA13)Wu Je Ping Medical Foundation (No.320.6750.2020-10-40)the Key Research and Development Program of Anhui Province (No.202004J07020052)。
文摘The application of a thermoluminescent detector(TLD) for dose detection at the liver irradiation site in mice under linear accelerator precision radiotherapy and the use of a single high dose to irradiate the mouse liver to construct a biological model of a radiation-induced liver injury(RILD) in mice were to determine the feasibility of constructing a precision radiotherapy model in small animals under a linear accelerator. A 360° arc volumetric rotational intensity-modulated radiotherapy(VMAT) plan with a prescribed dose of 2 Gy was developed for the planned target volume(PTV) at the location of the TLD within solid water to compare the difference between the measured dose of TLD and the assessed parameters in the TPS system. The TLD was implanted in the livers of mice, and VMAT was planned based on TLD to compare the measured and prescribed doses. C57BL/6 J mice were randomly divided into control and 25-Gy radiation groups and were examined daily for changes in body weight. They were euthanized at 3 and 10 weeks after radiation, and the levels of liver serum enzymes such as alanine aminotransferase(ALT), aspartate aminotransferase(AST), and alkaline phosphatase(ALP) were measured to observe any pathological histological changes in the irradiated areas of the mouse liver. The measured values of solid underwater TLD were within ± 3% of the Dmean value of the evaluation parameter in the TPS system. The mice in the 25-Gy radiation group demonstrated pathological signs of radiation-induced liver injury at the site of liver irradiation. The deviation in the measured and prescribed doses of TLD in the mouse liver ranged from-1.5 to 6%;construction of an accurate model of RILD using the VMAT technique under a linear accelerator is feasible.
基金supported by National Key Research and Development Program of China(No.2022YFC2401503)National Natural Science Foundation of China(Nos.11875299,61631001,U1532264,and 12005271).
文摘Intensity-modulated particle therapy(IMPT)with carbon ions is comparatively susceptible to various uncertainties caused by breathing motion,including range,setup,and target positioning uncertainties.To determine relative biological effectiveness-weighted dose(RWD)distributions that are resilient to these uncertainties,the reference phase-based four-dimensional(4D)robust optimization(RP-4DRO)and each phase-based 4D robust optimization(EP-4DRO)method in carbon-ion IMPT treatment planning were evaluated and compared.Based on RWD distributions,4DRO methods were compared with 4D conventional optimization using planning target volume(PTV)margins(PTV-based optimization)to assess the effectiveness of the robust optimization methods.Carbon-ion IMPT treatment planning was conducted in a cohort of five lung cancer patients.The results indicated that the EP-4DRO method provided better robustness(P=0.080)and improved plan quality(P=0.225)for the clinical target volume(CTV)in the individual respiratory phase when compared with the PTV-based optimization.Compared with the PTV-based optimization,the RP-4DRO method ensured the robustness(P=0.022)of the dose distributions in the reference breathing phase,albeit with a slight sacrifice of the target coverage(P=0.450).Both 4DRO methods successfully maintained the doses delivered to the organs at risk(OARs)below tolerable levels,which were lower than the doses in the PTV-based optimization(P<0.05).Furthermore,the RP-4DRO method exhibited significantly superior performance when compared with the EP-4DRO method in enhancing overall OAR sparing in either the individual respiratory phase or reference respiratory phase(P<0.05).In general,both 4DRO methods outperformed the PTV-based optimization in terms of OAR sparing and robustness.