In recent years,heavy ion accelerator technology has been rapidly developing worldwide and widely applied in the fields of space radiation simulation and particle therapy.Usually,a very high uniformity in the irradiat...In recent years,heavy ion accelerator technology has been rapidly developing worldwide and widely applied in the fields of space radiation simulation and particle therapy.Usually,a very high uniformity in the irradiation area is required for the extracted ion beams,which is crucial because it directly affects the experimental precision and therapeutic effect.Specifically,ultra-large-area and high-uniformity scanning are crucial requirements for spacecraft radiation effects assessment and serve as core specification for beamline terminal design.In the 300 MeV proton and heavy ion accelerator complex at the Space Environment Simulation and Research Infrastructure(SESRI),proton and heavy ion beams will be accelerated and ultimately delivered to three irradiation terminals.In order to achieve the required large irradiation area of 320 mm×320 mm,horizontal and vertical scanning magnets are used in the extraction beam line.However,considering the various requirements for beam species and energies,the tracking accuracy of power supplies(PSs),the eddy current effect of scanning magnets,and the fluctuation of ion bunch structure will reduce the irradiation uniformity.To mitigate these effects,a beam uniformity optimization method based on the measured beam distribution was proposed and applied in the accelerator complex at SESRI.In the experiment,the uniformity is successfully optimized from 75%to over 90%after five iterations of adjustment to the PS waveforms.In this paper,the method and experimental results were introduced.展开更多
This study investigates the paradoxical detonation behavior of TKX-50,a nitrogen-rich energetic material,exhibiting higher detonation velocities but lower metal acceleration ability compared to HMX.Through experimenta...This study investigates the paradoxical detonation behavior of TKX-50,a nitrogen-rich energetic material,exhibiting higher detonation velocities but lower metal acceleration ability compared to HMX.Through experimental measurements and theoretical calculations,we propose a novel three-factor competition mechanism to explain this phenomenon.TKX-50-based PBX formulations achieved detonation velocities up to 9100 m/s,surpassing HMX-based counterparts.However,cylinder expansion tests revealed a 15%reduction in metal acceleration ability.Thermochemical measurements showed lower detonation heat for TKX-50(4900 J/g)versus HMX(5645 J/g).Our mechanism involves:(1)compositional effects prevailing at high pressures;(2)Energy release becoming essential as pressure drops;(3)Pressure-dependent product composition evolution functioning at low pressure.VLW code calculations unveiled a"crossover"in Hugoniot curves,lending support to this mechanism.This study furnishes a new framework for comprehending the performance of nitrogen-rich energetic materials,with significant implications for the design and optimization of future high-energy density materials.展开更多
In this paper,an improved discharging circuit was proposed to quicken the decay of the current in the drive coil in a reluctance accelerator when the armature reaches the center of the coil.The aim of this is to preve...In this paper,an improved discharging circuit was proposed to quicken the decay of the current in the drive coil in a reluctance accelerator when the armature reaches the center of the coil.The aim of this is to prevent the suck-back effect caused by the residual current in drive coil.The method is adding a reverse charging branch with a small capacitor in the traditional pulsed discharging circuit.The results under the traditional circuit and the improved circuit were compared in a simulation.The experiment then verified the simulations and they had good agreement.Simulation and experiment both demonstrated the improved circuit can effectively prevent the suck-back effect and increase the efficiency.At the voltage of 800 V,an efficiency increase of 36.34% was obtained.展开更多
Low-permeability dense reservoirs,including micro-fractured reservoirs,are commonly characterized by high content of clay substances,high original water saturation,high sensitivity to invasive fluids,high capillary pr...Low-permeability dense reservoirs,including micro-fractured reservoirs,are commonly characterized by high content of clay substances,high original water saturation,high sensitivity to invasive fluids,high capillary pressure,complicated structure and anisotropic,high flow-resistance and micro pore throats etc,.Generally they also have lots of natural micro fractures,probably leading to stress sensibility.Main damaging factors in such reservoirs are water-sensibility and water-blocking caused by invasive fluids during drilling and production operations.Once damaged,formation permeability can rarely recovered.Numerous studies have shown that damaging extent of water-blocking ranges from 70% to 90%.Main damaging mechanisms and influencing factors of water-blocking were systematically analyzed.Also some feasible precaution or treating approaches of water-blocking were put forward.In a laboratory setting,a new multi-functional drilling fluid composed mainly of amphion polymer,sulfonation polymer,high effectively preventive water-blocking surfactants,ideal packing temporary bridging agents(TBA) and film-forming agents,etc.,were developed.New low-damage drilling fluids has many advantages,such as good rheological properties,excellent effectiveness of water-blocking prevention,good temporary plugging effect,low filtration and ultra-low permeability(API filtration≤5 mL,HTHP filtration≤10 mL,mud cake frictional coefficient≤0.14,permeability recovery>81%),can efficiently prevent or minimize damage,preserve natural formation and enhance comprehensive development-investment effect in TUHA Jurassic dense sandstone reservoir formation with low-permeability,the only one developing integrated condense gas field.Some references can be provided to similar reservoir formations.展开更多
The armature is an important part affecting the energy conversion efficiency of a reluctance accelerator.In this paper,six kinds of soft magnetic materials are chosen and four structures are designed for the armature....The armature is an important part affecting the energy conversion efficiency of a reluctance accelerator.In this paper,six kinds of soft magnetic materials are chosen and four structures are designed for the armature.At first,the circuit and magnetic force are theoretically analyzed.Then the armatures with different materials and structures are used in the simulation,and the performances are compared and analyzed.At last,the experiment verifies the theory analysis and simulation design.It is concluded that the saturation flux density and conductivity of the material are the key factors affecting the armature force,and the optimization of armature structure can effectively restrain the eddy current,reduce negative force and improve efficiency.Compared with cutting slits in solid armatures,laminating the sheets radially can reduce the eddy current more efficiently.Although slitting can prevent the eddy current to a certain extent,meanwhile,it will decrease the magnetic force because of the losing of magnetized volume and the surface area.Hence,choosing the high saturation flux density material and making out the armature with radially_laminated sheets will improve the efficiency of the reluctance accelerator.In this paper,the silicon steel radially_laminated armature is a better choice for the armature design of the reluctance accelerator.展开更多
This study established a method for easily and quickly estimating the specific activity produced in the concrete walls and floors of accelerator rooms during long-term operation of accelerator,for advanced zoning of a...This study established a method for easily and quickly estimating the specific activity produced in the concrete walls and floors of accelerator rooms during long-term operation of accelerator,for advanced zoning of activated/nonactivated areas in planning the decommissioning of an accelerator.We propose a new,highly sensitive method for nondestructively estimating the specific activity in concrete that can be applied to activation zoning.In this method,instead of direct determination of the specific activities of important long-half-life radionuclides for decommissioning,such as 152 Eu and 60 Co,we determine the specific activities of short-half-life radionuclides,24 Na and 56 Mn,in situ to obtain neutron flux.The obtained neutron flux and accelerator operation history yield the specific activities of 152 Eu and 60 Co for the advance zoning of activated/non-activated concrete.This method is a powerful long-term prediction tool for concrete activation.展开更多
The assessment of activated concrete is particularly difficult during the decommissioning of an accelerator facility.Destructive analysis by core boring is the only method of investigating the activity of concrete mat...The assessment of activated concrete is particularly difficult during the decommissioning of an accelerator facility.Destructive analysis by core boring is the only method of investigating the activity of concrete material.To address this problem,an in-situ and nondestructive analysis method was developed to determineγ-ray-emitting nuclides and their specific activities in the concrete walls and floor by using a portable germanium semiconductor detector.In this work,we examined a substitute for Ge detector to establish a simpler and more convenient method.As candidates,we focused on some scintillation type spectrometers,and the possibility of a substitute for a Ge detector was examined by both simulation and experiment.The detection limits were roughly estimated through Monte Carlo simulation for various scintillation crystals,and it was found that 1.5-inch LaBr3,CeBr3,and SrI2 could distinguish the clearance level.It was confirmed that the 1.5-inch LaBr3 could reproduce the calibration curve of the Ge detector in the experiment.The required thickness and length of the radiation shield for suppressing the background radiation during the measurement was also determined for the convenience of an actual decommissioning work.展开更多
In order to clear the activated area in electrostatic accelerator facilities,four accelerator facilities were selected and typical neutron emission experiments were performed.Neutron flux during operation and induced ...In order to clear the activated area in electrostatic accelerator facilities,four accelerator facilities were selected and typical neutron emission experiments were performed.Neutron flux during operation and induced activity caused by charged particles on the accelerator and its surrounding area after irradiation were measured.Also the monitored neutron flux and calculated value by Monte Carlo calculation using PHITS code were compared.It was confirmed that the results between calculated data and measured data showed the good agreement with each other.Finally,it was concluded that we have to take care the activation of beam line and target.But,it is not necessary to treat accelerator tank,surrounding materials,and building concrete as radioactive materials in case of decommissioning.展开更多
基金Supported by National Key R&D Program of China(2019YFA0405400)。
文摘In recent years,heavy ion accelerator technology has been rapidly developing worldwide and widely applied in the fields of space radiation simulation and particle therapy.Usually,a very high uniformity in the irradiation area is required for the extracted ion beams,which is crucial because it directly affects the experimental precision and therapeutic effect.Specifically,ultra-large-area and high-uniformity scanning are crucial requirements for spacecraft radiation effects assessment and serve as core specification for beamline terminal design.In the 300 MeV proton and heavy ion accelerator complex at the Space Environment Simulation and Research Infrastructure(SESRI),proton and heavy ion beams will be accelerated and ultimately delivered to three irradiation terminals.In order to achieve the required large irradiation area of 320 mm×320 mm,horizontal and vertical scanning magnets are used in the extraction beam line.However,considering the various requirements for beam species and energies,the tracking accuracy of power supplies(PSs),the eddy current effect of scanning magnets,and the fluctuation of ion bunch structure will reduce the irradiation uniformity.To mitigate these effects,a beam uniformity optimization method based on the measured beam distribution was proposed and applied in the accelerator complex at SESRI.In the experiment,the uniformity is successfully optimized from 75%to over 90%after five iterations of adjustment to the PS waveforms.In this paper,the method and experimental results were introduced.
基金support provided by the National Natural Science Foundation of China(Grant No.12102405)the Presidential Foundation of CAEP(Grant No.YZJJZQ2023008).
文摘This study investigates the paradoxical detonation behavior of TKX-50,a nitrogen-rich energetic material,exhibiting higher detonation velocities but lower metal acceleration ability compared to HMX.Through experimental measurements and theoretical calculations,we propose a novel three-factor competition mechanism to explain this phenomenon.TKX-50-based PBX formulations achieved detonation velocities up to 9100 m/s,surpassing HMX-based counterparts.However,cylinder expansion tests revealed a 15%reduction in metal acceleration ability.Thermochemical measurements showed lower detonation heat for TKX-50(4900 J/g)versus HMX(5645 J/g).Our mechanism involves:(1)compositional effects prevailing at high pressures;(2)Energy release becoming essential as pressure drops;(3)Pressure-dependent product composition evolution functioning at low pressure.VLW code calculations unveiled a"crossover"in Hugoniot curves,lending support to this mechanism.This study furnishes a new framework for comprehending the performance of nitrogen-rich energetic materials,with significant implications for the design and optimization of future high-energy density materials.
基金This work was supported by the Fundamental Research Funds for the Central Universities[Grant number 2019XJ01].
文摘In this paper,an improved discharging circuit was proposed to quicken the decay of the current in the drive coil in a reluctance accelerator when the armature reaches the center of the coil.The aim of this is to prevent the suck-back effect caused by the residual current in drive coil.The method is adding a reverse charging branch with a small capacitor in the traditional pulsed discharging circuit.The results under the traditional circuit and the improved circuit were compared in a simulation.The experiment then verified the simulations and they had good agreement.Simulation and experiment both demonstrated the improved circuit can effectively prevent the suck-back effect and increase the efficiency.At the voltage of 800 V,an efficiency increase of 36.34% was obtained.
基金Project(50574061) supported by the National Natural Science Foundation of China
文摘Low-permeability dense reservoirs,including micro-fractured reservoirs,are commonly characterized by high content of clay substances,high original water saturation,high sensitivity to invasive fluids,high capillary pressure,complicated structure and anisotropic,high flow-resistance and micro pore throats etc,.Generally they also have lots of natural micro fractures,probably leading to stress sensibility.Main damaging factors in such reservoirs are water-sensibility and water-blocking caused by invasive fluids during drilling and production operations.Once damaged,formation permeability can rarely recovered.Numerous studies have shown that damaging extent of water-blocking ranges from 70% to 90%.Main damaging mechanisms and influencing factors of water-blocking were systematically analyzed.Also some feasible precaution or treating approaches of water-blocking were put forward.In a laboratory setting,a new multi-functional drilling fluid composed mainly of amphion polymer,sulfonation polymer,high effectively preventive water-blocking surfactants,ideal packing temporary bridging agents(TBA) and film-forming agents,etc.,were developed.New low-damage drilling fluids has many advantages,such as good rheological properties,excellent effectiveness of water-blocking prevention,good temporary plugging effect,low filtration and ultra-low permeability(API filtration≤5 mL,HTHP filtration≤10 mL,mud cake frictional coefficient≤0.14,permeability recovery>81%),can efficiently prevent or minimize damage,preserve natural formation and enhance comprehensive development-investment effect in TUHA Jurassic dense sandstone reservoir formation with low-permeability,the only one developing integrated condense gas field.Some references can be provided to similar reservoir formations.
基金supported in part by the Fundamental Research Funds for the Central Universities,China[grant number 2682020GF03]in part by the Foundation of Key Laboratory of Magnetic Suspension Technology and Maglev Vehicle,Ministry of Education,China.
文摘The armature is an important part affecting the energy conversion efficiency of a reluctance accelerator.In this paper,six kinds of soft magnetic materials are chosen and four structures are designed for the armature.At first,the circuit and magnetic force are theoretically analyzed.Then the armatures with different materials and structures are used in the simulation,and the performances are compared and analyzed.At last,the experiment verifies the theory analysis and simulation design.It is concluded that the saturation flux density and conductivity of the material are the key factors affecting the armature force,and the optimization of armature structure can effectively restrain the eddy current,reduce negative force and improve efficiency.Compared with cutting slits in solid armatures,laminating the sheets radially can reduce the eddy current more efficiently.Although slitting can prevent the eddy current to a certain extent,meanwhile,it will decrease the magnetic force because of the losing of magnetized volume and the surface area.Hence,choosing the high saturation flux density material and making out the armature with radially_laminated sheets will improve the efficiency of the reluctance accelerator.In this paper,the silicon steel radially_laminated armature is a better choice for the armature design of the reluctance accelerator.
文摘This study established a method for easily and quickly estimating the specific activity produced in the concrete walls and floors of accelerator rooms during long-term operation of accelerator,for advanced zoning of activated/nonactivated areas in planning the decommissioning of an accelerator.We propose a new,highly sensitive method for nondestructively estimating the specific activity in concrete that can be applied to activation zoning.In this method,instead of direct determination of the specific activities of important long-half-life radionuclides for decommissioning,such as 152 Eu and 60 Co,we determine the specific activities of short-half-life radionuclides,24 Na and 56 Mn,in situ to obtain neutron flux.The obtained neutron flux and accelerator operation history yield the specific activities of 152 Eu and 60 Co for the advance zoning of activated/non-activated concrete.This method is a powerful long-term prediction tool for concrete activation.
文摘The assessment of activated concrete is particularly difficult during the decommissioning of an accelerator facility.Destructive analysis by core boring is the only method of investigating the activity of concrete material.To address this problem,an in-situ and nondestructive analysis method was developed to determineγ-ray-emitting nuclides and their specific activities in the concrete walls and floor by using a portable germanium semiconductor detector.In this work,we examined a substitute for Ge detector to establish a simpler and more convenient method.As candidates,we focused on some scintillation type spectrometers,and the possibility of a substitute for a Ge detector was examined by both simulation and experiment.The detection limits were roughly estimated through Monte Carlo simulation for various scintillation crystals,and it was found that 1.5-inch LaBr3,CeBr3,and SrI2 could distinguish the clearance level.It was confirmed that the 1.5-inch LaBr3 could reproduce the calibration curve of the Ge detector in the experiment.The required thickness and length of the radiation shield for suppressing the background radiation during the measurement was also determined for the convenience of an actual decommissioning work.
文摘In order to clear the activated area in electrostatic accelerator facilities,four accelerator facilities were selected and typical neutron emission experiments were performed.Neutron flux during operation and induced activity caused by charged particles on the accelerator and its surrounding area after irradiation were measured.Also the monitored neutron flux and calculated value by Monte Carlo calculation using PHITS code were compared.It was confirmed that the results between calculated data and measured data showed the good agreement with each other.Finally,it was concluded that we have to take care the activation of beam line and target.But,it is not necessary to treat accelerator tank,surrounding materials,and building concrete as radioactive materials in case of decommissioning.