Nowadays wind energy is the fastest growing renewable energy resource in the world.The problems of integrating wind farms are caused by changes of wind speed during a day.Moreover,the behaviors of wind turbines equipp...Nowadays wind energy is the fastest growing renewable energy resource in the world.The problems of integrating wind farms are caused by changes of wind speed during a day.Moreover,the behaviors of wind turbines equipped with doubly-fed induction generators differ fundamentally from synchronous generators.Therefore,more considerations are needed to analyze the performances of the distance protection relays.The protection of a wind farm with distance relay is inspected.By changing the conditions of the wind farm,the characteristics of the distance relay are studied.展开更多
An analytic electromagnetic calculation method for doubly fed induction generator(DFIG) in wind turbine system was presented. Based on the operation principles, steady state equivalent circuit and basic equations of D...An analytic electromagnetic calculation method for doubly fed induction generator(DFIG) in wind turbine system was presented. Based on the operation principles, steady state equivalent circuit and basic equations of DFIG, the modeling for electromagnetic calculation of DFIG was proposed. The electromagnetic calculation of DFIG was divided into three steps: the magnetic flux calculation, parameters derivation and performance checks. For each step, the detailed numeric calculation formulas were all derived. Combining the calculation formulas, the whole electromagnetic calculation procedure was established, which consisted of three iterative calculation loops, including magnetic saturation coefficient, electromotive force and total output power. All of the electromagnetic and performance data of DIFG can be calculated conveniently by the established calculation procedure, which can be used to evaluate the new designed machine. A 1.5 MW DFIG designed by the proposed procedure was built, for which the whole type tests including no-load test, load test and temperature rising test were carried out. The test results have shown that the DFIG satisfies technical requirements and the test data fit well with the calculation results which prove the correctness of the presented calculation method.展开更多
Large-scale doubly-fed induction generator(DFIG)wind turbines are connected to the grid and required to remain grid-connection during faults,the short-circuit current contributed by the generation has become a signifi...Large-scale doubly-fed induction generator(DFIG)wind turbines are connected to the grid and required to remain grid-connection during faults,the short-circuit current contributed by the generation has become a significant issue.However,the traditional calculation methods aiming at synchronous generators cannot be directly applied to the DFIG wind turbines.A new method is needed to calculate the short-circuit current required by the planning,protection and control of the power grid.The short-circuit transition of DFIG under symmetrical and asymmetric short-circuit conditions are mathematically deduced,and the short-circuit characteristics of DFIG are analyzed.A new method is proposed to calculate the steady-state short-circuit current of DFIG based on the derived expressions.The time-domain simulations are conducted to verify the accuracy of the proposed method.展开更多
With the rapid increase of wind farms,the grid code needs to be improved to meet the requirement of wind farms and enhance grid stability.Doubly-fed induction generators are largely used in wind turbines,but they are ...With the rapid increase of wind farms,the grid code needs to be improved to meet the requirement of wind farms and enhance grid stability.Doubly-fed induction generators are largely used in wind turbines,but they are very sensitive to grid disturbances.The voltage swell can be caused by switching on capacitor banks or switching off large loads,which may result in the reversal of the power flow in the grid convertor;the current may flow from the grid into the DC link,which may step up DC voltage,and result in large faults of rotor currents and instantaneous power oscillation.The grid reactive compensation devices can not have the automatic swithing function after the low voltage fault,which will result in local reactive power surplus,so some wind power generators will retreat from the grid under high voltage protection.展开更多
Future power system faces several challenges,one of them is the high penetration level of intermittent wind power generation,providing small or even no inertial response and being not contributing to the frequency sta...Future power system faces several challenges,one of them is the high penetration level of intermittent wind power generation,providing small or even no inertial response and being not contributing to the frequency stability.The effect of shaft stiffness on inertial response of fixed speed wind turbines is presented.Four different drive-train models based on the multi-body system are developed.The small-signal analysis demonstrates no significant differences between models in terms of electro-mechanical eigen-values for increasing shaft stiffness.The natural resonance frequency of drive-train torsion modes shows slightly different values between damped and undamped models,but no significant differences are found in the number-mass models.Time-domain simulations show the changes in the active power contribution of a wind farm based on a fixed speed wind turbine during the system frequency disturbance.The changes in the kinetic energy during the dynamic process are calculated and their contribution to the inertia constant is small and effective.The largest contribution of the kinetic energy is provided at the beginning of the system frequency disturbance to reduce the rate of the frequency change,it is positive for the frequency stability.展开更多
文摘Nowadays wind energy is the fastest growing renewable energy resource in the world.The problems of integrating wind farms are caused by changes of wind speed during a day.Moreover,the behaviors of wind turbines equipped with doubly-fed induction generators differ fundamentally from synchronous generators.Therefore,more considerations are needed to analyze the performances of the distance protection relays.The protection of a wind farm with distance relay is inspected.By changing the conditions of the wind farm,the characteristics of the distance relay are studied.
基金Project(2011DFA62240) supported by the International Scientific and Technological Cooperation Projects,ChinaProject(019945-SES6) supported by the European Union(EU)6th Framework Program UP-WIND Project,Denmark
文摘An analytic electromagnetic calculation method for doubly fed induction generator(DFIG) in wind turbine system was presented. Based on the operation principles, steady state equivalent circuit and basic equations of DFIG, the modeling for electromagnetic calculation of DFIG was proposed. The electromagnetic calculation of DFIG was divided into three steps: the magnetic flux calculation, parameters derivation and performance checks. For each step, the detailed numeric calculation formulas were all derived. Combining the calculation formulas, the whole electromagnetic calculation procedure was established, which consisted of three iterative calculation loops, including magnetic saturation coefficient, electromotive force and total output power. All of the electromagnetic and performance data of DIFG can be calculated conveniently by the established calculation procedure, which can be used to evaluate the new designed machine. A 1.5 MW DFIG designed by the proposed procedure was built, for which the whole type tests including no-load test, load test and temperature rising test were carried out. The test results have shown that the DFIG satisfies technical requirements and the test data fit well with the calculation results which prove the correctness of the presented calculation method.
基金supported by State Key Laboratory of Power Transmission Equipment and System Security(No.2007DA10512711102,No.2007DA10512709202)Program of Introducing Talents of Discipline to Universities("111"Program)(No.B08036)the Fundamental Research Funds for the Central Universities(No.CDJXS11150026)
文摘Large-scale doubly-fed induction generator(DFIG)wind turbines are connected to the grid and required to remain grid-connection during faults,the short-circuit current contributed by the generation has become a significant issue.However,the traditional calculation methods aiming at synchronous generators cannot be directly applied to the DFIG wind turbines.A new method is needed to calculate the short-circuit current required by the planning,protection and control of the power grid.The short-circuit transition of DFIG under symmetrical and asymmetric short-circuit conditions are mathematically deduced,and the short-circuit characteristics of DFIG are analyzed.A new method is proposed to calculate the steady-state short-circuit current of DFIG based on the derived expressions.The time-domain simulations are conducted to verify the accuracy of the proposed method.
文摘With the rapid increase of wind farms,the grid code needs to be improved to meet the requirement of wind farms and enhance grid stability.Doubly-fed induction generators are largely used in wind turbines,but they are very sensitive to grid disturbances.The voltage swell can be caused by switching on capacitor banks or switching off large loads,which may result in the reversal of the power flow in the grid convertor;the current may flow from the grid into the DC link,which may step up DC voltage,and result in large faults of rotor currents and instantaneous power oscillation.The grid reactive compensation devices can not have the automatic swithing function after the low voltage fault,which will result in local reactive power surplus,so some wind power generators will retreat from the grid under high voltage protection.
文摘Future power system faces several challenges,one of them is the high penetration level of intermittent wind power generation,providing small or even no inertial response and being not contributing to the frequency stability.The effect of shaft stiffness on inertial response of fixed speed wind turbines is presented.Four different drive-train models based on the multi-body system are developed.The small-signal analysis demonstrates no significant differences between models in terms of electro-mechanical eigen-values for increasing shaft stiffness.The natural resonance frequency of drive-train torsion modes shows slightly different values between damped and undamped models,but no significant differences are found in the number-mass models.Time-domain simulations show the changes in the active power contribution of a wind farm based on a fixed speed wind turbine during the system frequency disturbance.The changes in the kinetic energy during the dynamic process are calculated and their contribution to the inertia constant is small and effective.The largest contribution of the kinetic energy is provided at the beginning of the system frequency disturbance to reduce the rate of the frequency change,it is positive for the frequency stability.