期刊文献+
共找到7篇文章
< 1 >
每页显示 20 50 100
4.3 THz quantum-well photodetectors with high detection sensitivity 被引量:2
1
作者 Zhenzhen Zhang Zhanglong FU +1 位作者 Xuguang Guo Juncheng Cao 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第3期201-204,共4页
We demonstrate a high performance GaAs/AlGaAs-based quantum-well photodetector(QWP)device with a peak response frequency of 4.3 THz.The negative differential resistance(NDR)phenomenon is found in the dark currentvolta... We demonstrate a high performance GaAs/AlGaAs-based quantum-well photodetector(QWP)device with a peak response frequency of 4.3 THz.The negative differential resistance(NDR)phenomenon is found in the dark currentvoltage(I-V)curve in the current sweeping measurement mode,from which the breakdown voltage is determined.The photocurrent spectra and blackbody current responsivities at different voltages are measured.Based on the experimental data,the peak responsivity of 0.3 A/W(at 0.15 V,8 K)is derived,and the detection sensitivity is higher than 10^(11)Jones,which is in the similar level as that of the commercialized liquid-helium-cooled silicon bolometers.We attribute the high detection performance of the device to the small ohmic contact resistance of-2Ωand the big breakdown bias. 展开更多
关键词 terahertz quantum-well photodetector negative differential resistance detection sensitivity pho-tocurrent spectra
在线阅读 下载PDF
Multi-area detection sensitivity calculation model and detection blind areas influence analysis of photoelectric detection target 被引量:1
2
作者 Han-shan Li Xiao-qian Zhang Hui Guan 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2022年第4期547-556,共10页
Multi-element array photoelectric detector is the core devices to form a photoelectric detection target with a large field of view.This photoelectric detection target brings about the problem of uneven detection sensi... Multi-element array photoelectric detector is the core devices to form a photoelectric detection target with a large field of view.This photoelectric detection target brings about the problem of uneven detection sensitivity distribution in the detection screen.To improve the uneven detection sensitivity of this photoelectric detection target,this paper analyzes the distribution law of the uneven detection sensitivity of the photoelectric detection target using the multi-element array photoelectric detector,dissects the main factors affecting the detection sensitivity according to the photoelectric detection principle,establishes the calculation model of detection sensitivity of the photoelectric detection target in the different detection areas and proposes a method to improve the detection sensitivity by compensating the gain of each unit photoelectric detector.The analysis of simulation and experimental results show that the proposed method of photoelectric detection target can effectively improve the output signal amplitude of the projectile under the certain detection distance,in particular,the output signal amplitude of the projectile is significantly increased when the projectile passes through the detection blind area.The experimental results are consistent with the simulation results,which verify the effectiveness of the proposed improvement method. 展开更多
关键词 PROJECTILE Photoelectric detection target Multi-element array photoelectric detector detection sensitivity detection screen
在线阅读 下载PDF
Highly Sensitive Detection of Strontium Ions Using Metal-Organic Frameworks Functionalized Solid-state Nanochannels
3
作者 Xu-Gang Wang Zheng-Xu He +6 位作者 De-Fang Ding Xue-Qin Luo Li Dai Wei-Qi Zhang Qun Ma Yu Huang Fan Xia 《电化学(中英文)》 CAS 北大核心 2024年第10期29-40,共12页
Strontium-90,a highly radioactive isotope,accumulates within the food chain and skeletal structure,posing significant risks to human health.There is a critical need for a sensitive detection strategy for Strontium-90 ... Strontium-90,a highly radioactive isotope,accumulates within the food chain and skeletal structure,posing significant risks to human health.There is a critical need for a sensitive detection strategy for Strontium-90 in complex environmental samples.Here,solid-state nanochannels,modified with metal-organic frameworks(MOF)and specific aptamers,were engineered for highly sensitive detection of strontium ion(Sr^(2+)).The synergistic effect between the reduced effective diameter of the nanochannels due to MOF and the specific binding of Sr^(2+) by aptamers amplifies the difference in ionic current signals,enhancing detection sensitivity significantly.The MOF-modified nanochannels exhibit highly sensitive detection of Sr^(2+),with a limit of detection(LOD)being 0.03 nmol·L^(-1),whereas the LOD for anodized aluminum oxide(AAO)without the modified MOF nanosheets is only 1000 nmol·L^(-1).These findings indicate that the LOD of Sr^(2+) detected by the MOF-modified nanochannels is approximately 33,000 times higher than that by the nanochannels without MOF modification.Additionally,the highly reliable detection of Sr^(2+) in various water samples was achieved,with a recovery rate ranging from 94.00%to 118.70%.This study provides valuable insights into the rapidly advancing field of advanced nanochannel-based sensors and their diverse applications for analyzing complex samples,including environmental contaminant detection,food analysis,medical diagnostics,and more. 展开更多
关键词 NANOCHANNEL Metal-organic frameworks Sensor Strontium ion sensitivity detection
在线阅读 下载PDF
Research of the Phase Sensitive Detection Property of Magnetic Sensor Based on Hall Effect
4
作者 陈金岳 周立伟 +1 位作者 丁守谦 李文深 《Journal of Beijing Institute of Technology》 EI CAS 1998年第1期32-38,共7页
Aim to detect the characteristic weak magnetic field signal against the strong noises background. Methods In combination with a low-pass-filter, the correlation output of magne-* tic sensors between the magnetic field... Aim to detect the characteristic weak magnetic field signal against the strong noises background. Methods In combination with a low-pass-filter, the correlation output of magne-* tic sensors between the magnetic field and reference current was utilized to provide a DC output voltage proportional to the applied magnetic induction, computer simulation was* done to investigate the correlation output of the Hall-effect sensors. Results Some analysis results concerning the noise property, harmonic supppression and the sensitivity were given. Conclsion The minimum detection signal of the equipment evolved from the mentioned cor-* relation theory can be 10-6 T. In addition to the DC output, such sensors can also measure the phase of the detected magnetic induction and has good harmonic suppression as well as* noise elimination. 展开更多
关键词 CORRELATION Hall magnetic sensor phase sensitive detection*
在线阅读 下载PDF
Generation of broadly tunable picosecond mid-infrared laser and sensitive detection of a mid-infrared signal by parametric frequency up-conversion in MgO:LiNbO_3 optical parametric amplifiers
5
作者 张秋琳 张静 +3 位作者 邱康生 张东香 冯宝华 张景园 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第5期294-299,共6页
Picosecond optical parametric generation and amplification in the near-infrared region within 1.361-1.656 μm and the mid-infrared region within 2.976-4.875 μm is constructed on the basis of bulk MgO:LiNbO 3 crystal... Picosecond optical parametric generation and amplification in the near-infrared region within 1.361-1.656 μm and the mid-infrared region within 2.976-4.875 μm is constructed on the basis of bulk MgO:LiNbO 3 crystals pumped at 1.064 μm.The maximum pulse energy reaches 1.3 mJ at 1.464 μm and 0.47 mJ at 3.894 μm,corresponding to a pumpto-idler photon conversion efficiency of 25%.By seeding the hard-to-measure mid-infrared radiation as the idler in the optical parametric amplification and measuring the amplified and frequency up-converted signal in the near-infrared or even visible region,one can measure very week mid-infrared radiation with ordinary detectors,which are insensitive to mid-infrared radiation,with a very high gain.A maximum gain factor of about 7 脳 10 7 is achieved at the mid-infrared wavelength of 3.374 μm and the corresponding energy detection limit is as low as about 390 aJ per pulse. 展开更多
关键词 optical parametric amplifiers picoseconds mid-infrared laser sensitive detection
在线阅读 下载PDF
A Surface Plasmon Resonance-based Immunosensors for Sensitive Detection of Heroin
6
作者 吴仲城 陈文革 +3 位作者 王连超 戈瑜 虞承端 方廷健 《Plasma Science and Technology》 SCIE EI CAS CSCD 2000年第6期581-587,共7页
A simple technique for sensitive detection of heroine based on surface- plasmonresonance has been theoretically and experimentally investigated. The experiment was realized by using an anti-MO monoclonal antibody and ... A simple technique for sensitive detection of heroine based on surface- plasmonresonance has been theoretically and experimentally investigated. The experiment was realized by using an anti-MO monoclonal antibody and a morphine (MO)-bovine serum albumin (MOBSA) conjugate (antigen). The reason for using MO-BSA in the detection of heroine was also discussed. MO-BSA was immobilized on a gold thin film of SPR sensor chip by physical adsorption. The configuration of the device is allowed to be further miniaturized, which is required for the construction of a portable SPR device in the application of in-situ analysis. 展开更多
关键词 A Surface Plasmon Resonance-based Immunosensors for Sensitive detection of Heroin SPW BSA
在线阅读 下载PDF
Highly Sensitive Detection of Deoxyribonucleic Acid Hybridization Using Au-Gated AlInN/GaN High Electron Mobility Transistor-Based Sensors
7
作者 Xiang-Mi Zhan Mei-Lan Ha +7 位作者 Quan Wang Wei Li Hong-Ling Xiao Chun Feng Li-Juan Jiang Cui-Mei Wang Xiao-Liang Wang Zhan-Guo Wang 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第4期75-78,共4页
Gallium nitride- (GaN) based high electron mobility transistors (HEMTs) provide a good platform for biological detection. In this work, both Au-gated AlInN/GaN HEMT and AlGaN/GaN HEMT biosensors are fabricated for... Gallium nitride- (GaN) based high electron mobility transistors (HEMTs) provide a good platform for biological detection. In this work, both Au-gated AlInN/GaN HEMT and AlGaN/GaN HEMT biosensors are fabricated for the detection of deoxyribonucleic acid (DNA) hybridization. The Au-gated AIInN/GaN HEMT biosensor exhibits higher sensitivity in comparison with the AlGaN/GaN HEMT biosensor. For the former, the drain-source current (VDS = 0.5 V) shows a clear decrease of 69μA upon the introduction of 1μmolL^-1 (μM) complimentary DNA to the probe DNA at the sensor area, while for the latter it is only 38 μA. This current reduction is a notable indication of the hybridization. The high sensitivity can be attributed to the thinner barrier of the AlInN/GaN heterostructure, which makes the two-dimensional electron gas channel more susceptible to a slight change of the surface charge. 展开更多
关键词 GAN In Highly Sensitive detection of Deoxyribonucleic Acid Hybridization Using Au-Gated AlInN/GaN High Electron Mobility Transistor-Based Sensors
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部