期刊文献+
共找到17篇文章
< 1 >
每页显示 20 50 100
Deblurring,artifact-free optical coherence tomography with deconvolution-random phase modulation 被引量:1
1
作者 Xin Ge Si Chen +4 位作者 Kan Lin Guangming Ni En Bo Lulu Wang Linbo Liu 《Opto-Electronic Science》 2024年第1期13-24,共12页
Deconvolution is a commonly employed technique for enhancing image quality in optical imaging methods.Unfortu-nately,its application in optical coherence tomography(OCT)is often hindered by sensitivity to noise,which ... Deconvolution is a commonly employed technique for enhancing image quality in optical imaging methods.Unfortu-nately,its application in optical coherence tomography(OCT)is often hindered by sensitivity to noise,which leads to ad-ditive ringing artifacts.These artifacts considerably degrade the quality of deconvolved images,thereby limiting its effect-iveness in OCT imaging.In this study,we propose a framework that integrates numerical random phase masks into the deconvolution process,effectively eliminating these artifacts and enhancing image clarity.The optimized joint operation of an iterative Richardson-Lucy deconvolution and numerical synthesis of random phase masks(RPM),termed as De-conv-RPM,enables a 2.5-fold reduction in full width at half-maximum(FWHM).We demonstrate that the Deconv-RPM method significantly enhances image clarity,allowing for the discernment of previously unresolved cellular-level details in nonkeratinized epithelial cells ex vivo and moving blood cells in vivo. 展开更多
关键词 deconvolution random phase masks DEBLURRING
在线阅读 下载PDF
Study of inter-well interference in shale gas reservoirs by a robust production data analysis method based on deconvolution
2
作者 Wen-Chao Liu Cheng-Cheng Qiao +5 位作者 Ping Wang Wen-Song Huang Xiang-Wen Kong Yu-Ping Sun He-Dong Sun Yue-Peng Jia 《Petroleum Science》 SCIE EI CAS CSCD 2024年第4期2502-2519,共18页
In order to overcome the defects that the analysis of multi-well typical curves of shale gas reservoirs is rarely applied to engineering,this study proposes a robust production data analysis method based on deconvolut... In order to overcome the defects that the analysis of multi-well typical curves of shale gas reservoirs is rarely applied to engineering,this study proposes a robust production data analysis method based on deconvolution,which is used for multi-well inter-well interference research.In this study,a multi-well conceptual trilinear seepage model for multi-stage fractured horizontal wells was established,and its Laplace solutions under two different outer boundary conditions were obtained.Then,an improved pressure deconvolution algorithm was used to normalize the scattered production data.Furthermore,the typical curve fitting was carried out using the production data and the seepage model solution.Finally,some reservoir parameters and fracturing parameters were interpreted,and the intensity of inter-well interference was compared.The effectiveness of the method was verified by analyzing the production dynamic data of six shale gas wells in Duvernay area.The results showed that the fitting effect of typical curves was greatly improved due to the mutual restriction between deconvolution calculation parameter debugging and seepage model parameter debugging.Besides,by using the morphological characteristics of the log-log typical curves and the time corresponding to the intersection point of the log-log typical curves of two models under different outer boundary conditions,the strength of the interference between wells on the same well platform was well judged.This work can provide a reference for the optimization of well spacing and hydraulic fracturing measures for shale gas wells. 展开更多
关键词 Shale gas Inter-well interference deconvolution Production data analysis Typical curves Multi-stage fractured horizontal well
在线阅读 下载PDF
Cryo-EM combined with image deconvolution to determine ZIF-8 crystal structure
3
作者 吴抗 杨柏松 +3 位作者 薛文华 孙大鹏 葛炳辉 王玉梅 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第7期44-49,共6页
Metal–organic frameworks(MOFs) are crystalline porous materials with tunable properties, exhibiting great potential in gas adsorption, separation and catalysis.[1,2]It is challenging to visualize MOFs with transmissi... Metal–organic frameworks(MOFs) are crystalline porous materials with tunable properties, exhibiting great potential in gas adsorption, separation and catalysis.[1,2]It is challenging to visualize MOFs with transmission electron microscopy(TEM) due to their inherent instability under electron beam irradiation. Here, we employ cryo-electron microscopy(cryoEM) to capture images of MOF ZIF-8, revealing inverted-space structural information at a resolution of up to about 1.7A and enhancing its critical electron dose to around 20 e^(-)/A^(2). In addition, it is confirmed by electron-beam irradiation experiments that the high voltage could effectively mitigate the radiolysis, and the structure of ZIF-8 is more stable along the [100] direction under electron beam irradiation. Meanwhile, since the high-resolution electron microscope images are modulated by contrast transfer function(CTF) and it is difficult to determine the positions corresponding to the atomic columns directly from the images. We employ image deconvolution to eliminate the impact of CTF and obtain the structural images of ZIF-8. As a result, the heavy atom Zn and the organic imidazole ring within the organic framework can be distinguished from structural images. 展开更多
关键词 cryo-electron microscopy(cryo-EM) ZIF-8 image deconvolution crystal structure determination
在线阅读 下载PDF
Research on a deconvolution algorithm for laser-induced fluorescence diagnosis based on the maximum entropy principle
4
作者 雷清雲 杨雄 +4 位作者 程谋森 张帆 郭大伟 李小康 肖文杰 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第7期93-107,共15页
Laser-induced fluorescence(LIF)spectroscopy is employed for plasma diagnosis,necessitating the utilization of deconvolution algorithms to isolate the Doppler effect from the raw spectral signal.However,direct deconvol... Laser-induced fluorescence(LIF)spectroscopy is employed for plasma diagnosis,necessitating the utilization of deconvolution algorithms to isolate the Doppler effect from the raw spectral signal.However,direct deconvolution becomes invalid in the presence of noise as it leads to infinite amplification of high-frequency noise components.To address this issue,we propose a deconvolution algorithm based on the maximum entropy principle.We validate the effectiveness of the proposed algorithm by utilizing simulated LIF spectra at various noise levels(signal-to-noise ratio,SNR=20–80 d B)and measured LIF spectra with Xe as the working fluid.In the typical measured spectrum(SNR=26.23 d B)experiment,compared with the Gaussian filter and the Richardson–Lucy(R-L)algorithm,the proposed algorithm demonstrates an increase in SNR of 1.39 d B and 4.66 d B,respectively,along with a reduction in the root-meansquare error(RMSE)of 35%and 64%,respectively.Additionally,there is a decrease in the spectral angle(SA)of 0.05 and 0.11,respectively.In the high-quality spectrum(SNR=43.96 d B)experiment,the results show that the running time of the proposed algorithm is reduced by about98%compared with the R-L iterative algorithm.Moreover,the maximum entropy algorithm avoids parameter optimization settings and is more suitable for automatic implementation.In conclusion,the proposed algorithm can accurately resolve Doppler spectrum details while effectively suppressing noise,thus highlighting its advantage in LIF spectral deconvolution applications. 展开更多
关键词 maximum entropy spectral deconvolution laser-induced fluorescence spectrum
在线阅读 下载PDF
Blind Deconvolution Method Based on Precondition Conjugate Gradients 被引量:1
5
作者 朱振宇 裴江云 +2 位作者 吕小林 刘洪 李幼铭 《Petroleum Science》 SCIE CAS CSCD 2004年第3期37-40,共4页
In seismic data processing, blind deconvolution is a key technology. Introduced in this paper is a flow of one kind of blind deconvolution. The optimal precondition conjugate gradients (PCG) in Kyrlov subspace is als... In seismic data processing, blind deconvolution is a key technology. Introduced in this paper is a flow of one kind of blind deconvolution. The optimal precondition conjugate gradients (PCG) in Kyrlov subspace is also used to improve the stability of the algorithm. The computation amount is greatly decreased. 展开更多
关键词 Blind deconvolution precondition conjugate gradients (PCG) reflectivity series
在线阅读 下载PDF
Potential risks of spectrum whitening deconvolution——compared with well-driven deconvolution 被引量:13
6
作者 Li Guofa Zhou Hui Zhao Chao 《Petroleum Science》 SCIE CAS CSCD 2009年第2期146-152,共7页
Deconvolution is widely used to increase the resolution of seismic data. To compare the resolution ability of conventional spectrum whitening deconvolution to thin layers with that of welldriven deconvolution, a compl... Deconvolution is widely used to increase the resolution of seismic data. To compare the resolution ability of conventional spectrum whitening deconvolution to thin layers with that of welldriven deconvolution, a complex sedimentary geological model was designed, and then the simulated seismic data were processed respectively by each of the two methods. The amplitude spectrum of seismic data was almost white after spectrum whitening, but the wavelet resolution was low. The amplitude spectrum after well-driven deconvolution deviated from white spectrum, but the wavelet resolution was high. Further analysis showed that if an actual reflectivity series could not well satisfy the hypothesis of white spectrum, spectrum whitening deconvolution had a potential risk of wavelet distortion, which might lead to a pitfall in high resolution seismic data interpretation. On the other hand, the wavelet after well- driven deconvolution had higher resolution both in the time and frequency domains. It is favorable for high resolution seismic interpretation and reservoir prediction. 展开更多
关键词 Well-driven high resolution spectrum whitening deconvolution seismic wavelet
在线阅读 下载PDF
An improved deconvolution method for X-ray coded imaging in inertial confinement fusion
7
作者 赵宗清 何卫华 +4 位作者 王剑 郝轶丹 曹磊峰 谷渝秋 张保汉 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第10期281-286,共6页
In inertial confinement fusion (ICF), X-ray coded imaging is considered as the most potential means to diagnose the compressed core. The traditional Richardson-Lucy (RL) method has a strong ability to deblur the i... In inertial confinement fusion (ICF), X-ray coded imaging is considered as the most potential means to diagnose the compressed core. The traditional Richardson-Lucy (RL) method has a strong ability to deblur the image where the noise follows the Poisson distribution. However, it always suffers from over-fitting and noise amplification, especially when the signal-to-noise ratio of image is relatively low. In this paper, we propose an improved deconvolution method for X-ray coded imaging. We model the image data as a set of independent Gaussian distributions and derive the iterative solution with a maximum-likelihood scheme. The experimental results on X-ray coded imaging data demonstrate that this method is superior to the RL method in terms of anti-overfitting and noise suppression. 展开更多
关键词 inertial confinement fusion coded imaging deconvolution Gaussian distribution MAXIMUM-LIKELIHOOD
在线阅读 下载PDF
基于聚焦变换解卷积的宽带稳健波束形成
8
作者 生雪莉 陆典 +1 位作者 于洋 蔡晨阳 《哈尔滨工程大学学报(英文版)》 CSCD 2024年第2期425-433,共9页
In the field of array signal processing,uniform linear arrays(ULAs)are widely used to detect/separate a weak target and estimate its direction of arrival from interference and noise.Conventional beamforming(CBF)is rob... In the field of array signal processing,uniform linear arrays(ULAs)are widely used to detect/separate a weak target and estimate its direction of arrival from interference and noise.Conventional beamforming(CBF)is robust but restricted by a wide mainlobe and high sidelobe level.Covariance-matrix-inversed beamforming techniques,such as the minimum variance distortionless response and multiple signal classification,are sensitive to signal mismatch and data snapshots and exhibit high-resolution performance because of the narrow mainlobe and low sidelobe level.Therefore,compared with the wideband CBF,this study proposes a robust focused-and-deconvolved conventional beamforming(RFD-CBF),utilizing the Richardson–Lucy(R-L)iterative algorithm to deconvolve the focused conventional beam power of a half-wavelength spaced ULA.Then,the focused-and-deconvolved beam power achieves a narrower mainlobe and lower sidelobe level while retaining the robustness of wideband CBF.Moreover,compared with the wideband CBF,RFD-CBF can obtain a higher output signal-to-noise ratio(SNR).Finally,the performance of RFD-CBF is evaluated through numerical simulation and verified by sea trial data processing. 展开更多
关键词 WIDEBAND BEAMFORMING Focusing transform deconvolution High resolution Robust
在线阅读 下载PDF
Towards adaptable synchrotron image restoration pipeline
9
作者 Chun Li Xiao-Xue Bi +6 位作者 Yu-Jun Zhang Zhen Zhang Li-Wen Wang Jian Zhuang Dong-Liang Chen Yu-Hui Dong Yi Zhang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第10期4-16,共13页
Synchrotron microscopic data commonly suffer from poor image quality with degraded resolution incurred by instrumentation defects or experimental conditions.Image restoration methods are often applied to recover the r... Synchrotron microscopic data commonly suffer from poor image quality with degraded resolution incurred by instrumentation defects or experimental conditions.Image restoration methods are often applied to recover the reduced resolution,providing improved image details that can greatly facilitate scientific discovery.Among these methods,deconvolution techniques are straightforward,yet either require known prior information or struggle to tackle large experimental data.Deep learning(DL)-based super-resolution(SR)methods handle large data well,however data scarcity and model generalizability are problematic.In addition,current image restoration methods are mostly offline and inefficient for many beamlines where high data volumes and data complexity issues are encountered.To overcome these limitations,an online image-restoration pipeline that adaptably selects suitable algorithms and models from a method repertoire is promising.In this study,using both deconvolution and pretrained DL-based SR models,we show that different restoration efficacies can be achieved on different types of synchrotron experimental data.We describe the necessity,feasibility,and significance of constructing such an image-restoration pipeline for future synchrotron experiments. 展开更多
关键词 SYNCHROTRON deconvolution Deep learning SUPER-RESOLUTION PIPELINE
在线阅读 下载PDF
气相色谱-质谱数据的后处理 被引量:7
10
作者 张伟国 韩天祥 李重九 《分析测试学报》 CAS CSCD 北大核心 2004年第z1期148-150,共3页
  气相色谱-质谱(gas chromatography/mass spectrometry)以其优异的分离定性特点,被广泛地应用于分析复杂混合物中的挥发性组分.然而,其质谱图会包含一些来自于离子源污染物、柱流失物、基质干扰物所产生的离子,导致定性准确性降低.……
关键词 GC-MS deconvolution IDENTIFICATION
在线阅读 下载PDF
Unfolding analysis of LaBr3:Ce gamma spectrum with a detector response matrix constructing algorithm based on energy resolution calibration 被引量:12
11
作者 Rui Shi Xian-Guo Tuo +4 位作者 Huai-Liang Li Yang-Yang Xu Fan-Rong Shi Jian-Bo Yang Yong Luo 《Nuclear Science and Techniques》 SCIE CAS CSCD 2018年第1期23-31,共9页
With respect to the gamma spectrum, the energy resolution improves with increase in energy. The counts of full energy peak change with energy, and this approximately complies with the Gaussian distribution. This study... With respect to the gamma spectrum, the energy resolution improves with increase in energy. The counts of full energy peak change with energy, and this approximately complies with the Gaussian distribution. This study mainly examines a method to deconvolve the LaBr_3:Ce gamma spectrum with a detector response matrix constructing algorithm based on energy resolution calibration.In the algorithm, the full width at half maximum(FWHM)of full energy peak was calculated by the cubic spline interpolation algorithm and calibrated by a square root of a quadratic function that changes with the energy. Additionally, the detector response matrix was constructed to deconvolve the gamma spectrum. Furthermore, an improved SNIP algorithm was proposed to eliminate the background. In the experiment, several independent peaks of ^(152)Eu,^(137)Cs, and ^(60)Co sources were detected by a LaBr_3:Ce scintillator that were selected to calibrate the energy resolution. The Boosted Gold algorithm was applied to deconvolve the gamma spectrum. The results showed that the peak position difference between the experiment and the deconvolution was within ± 2 channels and the relative error of peak area was approximately within 0.96–6.74%. Finally, a ^(133) Ba spectrum was deconvolved to verify the efficiency and accuracy of the algorithm in unfolding the overlapped peaks. 展开更多
关键词 Detector response MATRIX Energy resolution CALIBRATION LaBr3:Ce scintillator SNIP background elimination Boosted Gold deconvolution ALGORITHM
在线阅读 下载PDF
A novel method for gamma spectrum analysis of low-level and intermediate-level radioactive waste 被引量:3
12
作者 Hui Yang Xin-Yu Zhang +4 位作者 Wei-Guo Gu Bing Dong Xue-Zhi Jiang Wen-Tao Zhou De-Zhong Wang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第6期199-213,共15页
The uncertainty of nuclide libraries in the analysis of the gamma spectra of low-and intermediate-level radioactive waste(LILW)using existing methods produces unstable results.To address this problem,a novel spectral ... The uncertainty of nuclide libraries in the analysis of the gamma spectra of low-and intermediate-level radioactive waste(LILW)using existing methods produces unstable results.To address this problem,a novel spectral analysis method is proposed in this study.In this method,overlapping peaks are located using a continuous wavelet transform.An improved quadratic convolution method is proposed to calculate the widths of the peaks and establish a fourth-order filter model to estimate the Compton edge baseline with the overlapping peaks.Combined with the adaptive sensitive nonlinear iterative peak,this method can effectively subtracts the background.Finally,a function describing the peak shape as a filter is used to deconvolve the energy spectrum to achieve accurate qualitative and quantitative analyses of the nuclide without the aid of a nuclide library.Gamma spectrum acquisition experiments for standard point sources of Cs-137 and Eu-152,a segmented gamma scanning experiment for a 200 L standard drum,and a Monte Carlo simulation experiment for triple overlapping peaks using the closest energy of three typical LILW nuclides(Sb-125,Sb-124,and Cs-134)are conducted.The results of the experiments indicate that(1)the novel method and gamma vision(GV)with an accurate nuclide library have the same spectral analysis capability,and the peak area calculation error is less than 4%;(2)compared with the GV,the analysis results of the novel method are more stable;(3)the novel method can be applied to the activity measurement of LILW,and the error of the activity reconstruction at the equivalent radius is 2.4%;and(4)The proposed novel method can quantitatively analyze all nuclides in LILW without a nuclide library.This novel method can improve the accuracy and precision of LILW measurements,provide key technical support for the reasonable disposal of LILW,and ensure the safety of humans and the environment. 展开更多
关键词 HPGe detector Low-level and intermediate-level radioactive waste Gamma spectrum analysis method deconvolution method Continuous wavelet transform
在线阅读 下载PDF
Processing and analysis of transient pressure measurements from permanent down-hole gauges 被引量:2
13
作者 Wang Fei 《Petroleum Science》 SCIE CAS CSCD 2012年第3期330-335,共6页
With permanent down-hole gauges (PDGs) widely installed in oilfields around the world in recent years, a continuous stream of transient pressure data in real time is now available, which motivates a new round of res... With permanent down-hole gauges (PDGs) widely installed in oilfields around the world in recent years, a continuous stream of transient pressure data in real time is now available, which motivates a new round of research interests in further developing pressure transient processing and analysis techniques. Transient pressure measurements from PDG are characterized by long term and high volume data. These data are recorded under unconstrained circumstances, so effects due to noise, rate fluctuation and interference from other wells cannot be avoided. These effects make the measured pressure trends decline or rise and then obscure or distort the actual flow behavior, which makes subsequent analysis difficult. In this paper, the problems encountered in analysis of PDG transient pressure are investigated. A newly developed workflow for processing and analyzing PDG transient pressure data is proposed. Numerical well testing synthetic studies are performed to demonstrate these procedures. The results prove that this new technique works well and the potential for practical application looks very promising. 展开更多
关键词 Permanent down-hole gauge transient pressure data processing deconvolution technique numerical well testing
在线阅读 下载PDF
Toward real-time digital pulse process algorithms for CsI(Tl)detector array at external target facility in HIRFL-CSR 被引量:2
14
作者 Tao Liu Hai-Sheng Song +13 位作者 Yu-Hong Yu Duo Yan Zhi-Yu Sun Shu-Wen Tang Fen-Hua Lu Shi-Tao Wang Xue-Heng Zhang Xian-Qin Li Hai-Bo Yang Fang Fang Yong-Jie Zhang Shao-Bo Ma Hooi-Jin Ong Cheng-Xin Zhao 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第9期8-20,共13页
A fully digital data acquisition system based on a field-programmable gate array(FPGA) was developed for a CsI(Tl) array at the external target facility(ETF) in the Heavy Ion Research Facility in Lanzhou(HIRFL). To pr... A fully digital data acquisition system based on a field-programmable gate array(FPGA) was developed for a CsI(Tl) array at the external target facility(ETF) in the Heavy Ion Research Facility in Lanzhou(HIRFL). To process the CsI(Tl) signals generated by γ-rays and light-charged ions, a scheme for digital pulse processing algorithms is proposed. Every step in the algorithms was benchmarked using standard γ and α sources. The scheme, which included a moving average filter, baseline restoration, leading-edge discrimination, moving window deconvolution, and digital charge comparison, was subsequently implemented on the FPGA. A good energy resolution of 5.7% for 1.33-MeV γ-rays and excellent α-γ identification using the digital charge comparison method were achieved, which satisfies CsI(Tl) array performance requirements. 展开更多
关键词 CsI(Tl)array On-line digital algorithms Moving average filter Moving window deconvolution On-line particle identification algorithms
在线阅读 下载PDF
Deconvolved Beamforming Using the Chebyshev Weighting Method 被引量:1
15
作者 Shuhui Wang Mingyang Lu +1 位作者 Jidan Mei Wenting Cui 《Journal of Marine Science and Application》 CSCD 2022年第3期228-235,共8页
This paper studies a deconvolved Chebyshev beamforming(Dcv-Che-BF)method.Compared with other deconvolution beamforming methods,Dcv-Che-BF can preset sidelobe levels according to the actual situation,which can achieve ... This paper studies a deconvolved Chebyshev beamforming(Dcv-Che-BF)method.Compared with other deconvolution beamforming methods,Dcv-Che-BF can preset sidelobe levels according to the actual situation,which can achieve higher resolution performance.However,the performance of Dcv-Che-BF was not necessarily better with a lower preset sidelobe level in the presence of noise.Instead,it was much better when the preset side lobe level matched the signal to noise ratio of the signal.The performance of the Dcv-Che-BF method with different preset sidelobe levels was analyzed using simulation.The Dcv-Che-BF method achieved a lower sidelobe level and better resolution capability when the preset sidelobe level was slightly greater than the noise background level.To validate the feasibility and performance of the proposed method,computer simulations and sea trials were analyzed.The results show that the Dcv-Che-BF method is a robust high-resolution beamforming method that can achieve a narrow mainlobe and low sidelobe. 展开更多
关键词 Chebyshev weighting deconvolution BEAMFORMING High resolution ROBUST
在线阅读 下载PDF
Large-eddy simulations of a forced homogeneous isotropic turbulence with polymer additives 被引量:1
16
作者 王璐 蔡伟华 李凤臣 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第3期348-360,共13页
Large-eddy simulations (LES) based on the temporal approximate deconvolution model were performed for a forced homogeneous isotropic turbulence (FHIT) with polymer additives at moderate Taylor Reynolds number. Fin... Large-eddy simulations (LES) based on the temporal approximate deconvolution model were performed for a forced homogeneous isotropic turbulence (FHIT) with polymer additives at moderate Taylor Reynolds number. Finitely extensible nonlinear elastic in the Peterlin approximation model was adopted as the constitutive equation for the filtered conformation tensor of the polymer molecules. The LES results were verified through comparisons with the direct numerical simulation results. Using the LES database of the FHIT in the Newtonian fluid and the polymer solution flows, the polymer effects on some important parameters such as strain, vorticity, drag reduction, and so forth were studied. By extracting the vortex structures and exploring the flatness factor through a high-order correlation function of velocity derivative and wavelet analysis, it can be found that the small-scale vortex structures and small-scale intermittency in the FHIT are all inhibited due to the existence of the polymers. The extended self-similarity scaling law in the polymer solution flow shows no apparent difference from that in the Newtonian fluid flow at the currently simulated ranges of Reynolds and Weissenberg numbers. 展开更多
关键词 forced homogeneous isotropic turbulence polymer additives large-eddy simulation temporal ap-proximate deconvolution model
在线阅读 下载PDF
Development of picosecond pulse radiolysis system at Waseda University
17
作者 T Kuribayashi K Ushida +5 位作者 S Kashiwagi R Kuroda H Hirama M Kawaguchi Y Hama M Washio 《辐射研究与辐射工艺学报》 CAS CSCD 北大核心 2005年第2期69-69,共1页
A compact pulse radiolysis apparatus using a BNL-type s-band photocathode RF gun is now under development at Waseda University.The laser pulse is used for excitation of the photocathode and for generation of white lig... A compact pulse radiolysis apparatus using a BNL-type s-band photocathode RF gun is now under development at Waseda University.The laser pulse is used for excitation of the photocathode and for generation of white light,which is used for analyzing light in the pulse radiolysis. 展开更多
关键词 Pico-second pulse radiolysis system Data deconvolution
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部