Removing copper from nickel electrolysis anode solution has been a major keypoint in the nickel metallurgy industry.In this study,we proposed a novel process flow to promote removing copper from nickel electrolysis an...Removing copper from nickel electrolysis anode solution has been a major keypoint in the nickel metallurgy industry.In this study,we proposed a novel process flow to promote removing copper from nickel electrolysis anode solution.A simulated nickel anode solution was designed,and static and dynamic adsorption experiments were conducted to determine the best of solution pH,adsorption time and temperature,resin dosage and particle size,and stirring speed.The optimal conditions were explored for copper removal from nickel electrolysis anode solution.Based on the optimal experimental conditions and the relevant experimental data,a novel process for copper removal from nickel electrolysis anodes was designed and verified.This novel process of copper removal from nickel electrolysis anodes was confirmed with nickel anolyte solution with nickel 50−60 g/L and copper 0.5 g/L.After finishing the novel process of copper removal,the nickel in the purified nickel anolyte became undetectable and copper concentration was 3 mg/L,the novel process of resin adsorption to remove copper from nickel anode solution through static and dynamic adsorptions has an efficacious copper removal.It is a beneficial supplement to traditional methods.展开更多
To address the lack of systematic studies on heavy metal fluorescent probes in typical buffer solutions,this study developed a Fe^(3+)and Cu^(2+)fluorescent probe,DHU‑NP‑4,based on a naphthalimide fluorophore.Comparat...To address the lack of systematic studies on heavy metal fluorescent probes in typical buffer solutions,this study developed a Fe^(3+)and Cu^(2+)fluorescent probe,DHU‑NP‑4,based on a naphthalimide fluorophore.Comparative analysis of the probe's performance in various buffer systems revealed that buffers with high organic content are unsuitable for evaluating such probes.Furthermore,the pH of the solvent system was found to significantly influence the probe's behavior.Under highly acidic conditions(pH≤2),DHU‑NP‑4 exhibited exceptional specificity for Fe^(3+),while in alkaline conditions,it demonstrated high specificity for Cu^(2+).Leveraging these properties,the probe enabled the quantitative detection of Fe^(3+)and Cu^(2+)in solution.展开更多
The adsorption of Cu(Ⅱ)and Cr(Ⅵ)on diaspore was studied with the help of X-ray diffraction analysis,BET measurement,zeta potential measurement and atomic adsorption spectrometry.The adsorption equilibrium almost rea...The adsorption of Cu(Ⅱ)and Cr(Ⅵ)on diaspore was studied with the help of X-ray diffraction analysis,BET measurement,zeta potential measurement and atomic adsorption spectrometry.The adsorption equilibrium almost reaches within 60 min.The adsorption isotherms of Cu(Ⅱ)and Cr(Ⅵ)could be well described by the Langmuir equation.The adsorption capacities of Cu(Ⅱ)and Cr(Ⅵ)are 1.944 and 1.292 mg/g,respectively.The adsorption percentage of Cr(Ⅱ)increases with the increment of solution pH,but the adsorption percentage of Cr(Ⅵ)decreases.This could be explained by zeta potential theoretical and electrostatic attraction between metal ions and diaspore surface.展开更多
China has accumulated massive fine grained copper mine tailings stocks because of the past mining activities in this area. The tailings contain a variety of heavy metals, and the mass percent of Cu, which is one of th...China has accumulated massive fine grained copper mine tailings stocks because of the past mining activities in this area. The tailings contain a variety of heavy metals, and the mass percent of Cu, which is one of the main contaminants in tailings, is up to 0.2601% (analysis by XRF). The Cu can pollute soil and groundwater by rain leaching in the form of Cu(Ⅱ), furthermore ,the fine grained copper-ore-tailings can contaminant larger area by wind for its small granularity ( < 74 μm). The main cause of weathering of mine tailings is due to oxidative dissolution of sulfides. Microorganisms, such as Acidithiobacillus ferrooxidans, play an important role in weathering. These bacteria attach to exposed to mineral surfaces by excreting extracellular polymers and oxidize the sulfide mineral. Some of these bacteria also oxidize Fe2+ to Fe3+ which can chemically oxidize sulfide minerals. These reactions produce voluminous quantities of acid mine drainage and heavy metals which are harmful to the environment and human healthy. This study aims at finding the weathering effects of A. ferrooxidans to Cu(II) pollution of fine grained copper mine tailings, and our experiment applied indigenous A. ferrooxidans FJ-01 to leach the tailings. The optimum test parameters were obtained using shaking flask experiment and SEM observation under the following experimental conditions: 39 days residence time, pulp density 1%-15% (1%, 5% and 15%), 30℃, 120 rpm, pH between 1-3 and redox potential between 400-650 mV. The test results show that the leaching rate of Cu reached 43.1% when the pulp density was 1% after 33 days and kept invariant till the end of the test. In addition, the leaching rate of Cu will decrease as the increase of pulp density, and the maximum rate of 15% pulp density was only 12.5%. From the SEM, it can be seen that the fine grain of tailings flocculated to conglobation under the action of bacterial leaching.展开更多
In order to develop an energy saving electrodeposition process of copper, the electrodeposition of copper in copper sulfate solution by the ion exchange membrane primary cell (IMPC) method has been studied. The experi...In order to develop an energy saving electrodeposition process of copper, the electrodeposition of copper in copper sulfate solution by the ion exchange membrane primary cell (IMPC) method has been studied. The experiments were carried out in an ion exchange membrane primary cell with dimensions of 200 mm in length, 52 mm in width and 90 mm in height. The influences of temperature(294 323 K), interval between the anode and cathode (1.5 3.5 cm), mass concentrations of Cu 2+ (6 40 g/L), H 2SO 4(0 120 g/L) and Fe 3+ (3 9 g/L) in catholyte and solution flow rate (0 8 cm/s) on current density and current efficiency were investigated experimentally. The current density increases with the increase of temperature and concentrations of Cu 2+ and H 2SO 4 in catholyte. Cathode current efficiency decreases with the increase of concentration of Fe 3+ in catholyte and anode current efficiency decreases with the increase of temperature. The high quality cathodic copper can be obtained and the current density of membrane can be higher than 150 A/m 2 and the current density of cathode can be higher than 300 A/m 2. The experiment results show that IMPC method is effective for electrodeposition of copper.展开更多
This study presents the deep removal of copper (Ⅱ) from the simulated cobalt electrolyte using fabricated polystyrene-supported 2-aminomethylpyridine chelating resin (PS-AMP) in a fixed-bed.The effects of bed height ...This study presents the deep removal of copper (Ⅱ) from the simulated cobalt electrolyte using fabricated polystyrene-supported 2-aminomethylpyridine chelating resin (PS-AMP) in a fixed-bed.The effects of bed height (7.0–14.0 cm),feed flow rate (4.5–9.0 mL/min),initial copper (Ⅱ) concentration of the feed (250–1000 mg/L),feed temperature (25–40 ℃) and the value of pH (2.0–4.0) on the adsorption process of the PS-AMP resin were investigated.The experimental data showed that the PS-AMP resin can deeply eliminate copper (Ⅱ) from the simulated cobalt electrolyte.The bed height,feed flow rate,initial copper (Ⅱ) concentration of the feed,feed temperature and feed pH value which corresponded to the highest removal of copper (Ⅱ) were 7.0 cm with 35 mm of the column diameter,4.5 mL/min,40℃,1000 mg/L and 4.0,respectively.The breakthrough capacity,the saturated capacity of the column and the mass ratio of Cu/Co (g/g) in the saturated resin were correspondingly 16.51 mg/g dry resin,61.72 mg/g dry resin and 37.67 under the optimal experimental conditions.The copper (Ⅱ) breakthrough curves were fitted by the empirical models of Thomas,Yoon-Nelson and Adam-Bohart,respectively.The Thomas model was found to be the most suitable one for predicting how the concentration of copper (Ⅱ) in the effluent changes with the adsorption time.展开更多
基金Project(2019yff0216502)supported by the National Key Research&Development Plan of Ministry of Science and Technology of ChinaProject(2021SK1020-4)supported by the Major Science and Technological Innovation Project of Hunan Province,China。
文摘Removing copper from nickel electrolysis anode solution has been a major keypoint in the nickel metallurgy industry.In this study,we proposed a novel process flow to promote removing copper from nickel electrolysis anode solution.A simulated nickel anode solution was designed,and static and dynamic adsorption experiments were conducted to determine the best of solution pH,adsorption time and temperature,resin dosage and particle size,and stirring speed.The optimal conditions were explored for copper removal from nickel electrolysis anode solution.Based on the optimal experimental conditions and the relevant experimental data,a novel process for copper removal from nickel electrolysis anodes was designed and verified.This novel process of copper removal from nickel electrolysis anodes was confirmed with nickel anolyte solution with nickel 50−60 g/L and copper 0.5 g/L.After finishing the novel process of copper removal,the nickel in the purified nickel anolyte became undetectable and copper concentration was 3 mg/L,the novel process of resin adsorption to remove copper from nickel anode solution through static and dynamic adsorptions has an efficacious copper removal.It is a beneficial supplement to traditional methods.
文摘To address the lack of systematic studies on heavy metal fluorescent probes in typical buffer solutions,this study developed a Fe^(3+)and Cu^(2+)fluorescent probe,DHU‑NP‑4,based on a naphthalimide fluorophore.Comparative analysis of the probe's performance in various buffer systems revealed that buffers with high organic content are unsuitable for evaluating such probes.Furthermore,the pH of the solvent system was found to significantly influence the probe's behavior.Under highly acidic conditions(pH≤2),DHU‑NP‑4 exhibited exceptional specificity for Fe^(3+),while in alkaline conditions,it demonstrated high specificity for Cu^(2+).Leveraging these properties,the probe enabled the quantitative detection of Fe^(3+)and Cu^(2+)in solution.
基金Project(2005CB623701)supported by the Major State Basic Research Development Program of China
文摘The adsorption of Cu(Ⅱ)and Cr(Ⅵ)on diaspore was studied with the help of X-ray diffraction analysis,BET measurement,zeta potential measurement and atomic adsorption spectrometry.The adsorption equilibrium almost reaches within 60 min.The adsorption isotherms of Cu(Ⅱ)and Cr(Ⅵ)could be well described by the Langmuir equation.The adsorption capacities of Cu(Ⅱ)and Cr(Ⅵ)are 1.944 and 1.292 mg/g,respectively.The adsorption percentage of Cr(Ⅱ)increases with the increment of solution pH,but the adsorption percentage of Cr(Ⅵ)decreases.This could be explained by zeta potential theoretical and electrostatic attraction between metal ions and diaspore surface.
文摘China has accumulated massive fine grained copper mine tailings stocks because of the past mining activities in this area. The tailings contain a variety of heavy metals, and the mass percent of Cu, which is one of the main contaminants in tailings, is up to 0.2601% (analysis by XRF). The Cu can pollute soil and groundwater by rain leaching in the form of Cu(Ⅱ), furthermore ,the fine grained copper-ore-tailings can contaminant larger area by wind for its small granularity ( < 74 μm). The main cause of weathering of mine tailings is due to oxidative dissolution of sulfides. Microorganisms, such as Acidithiobacillus ferrooxidans, play an important role in weathering. These bacteria attach to exposed to mineral surfaces by excreting extracellular polymers and oxidize the sulfide mineral. Some of these bacteria also oxidize Fe2+ to Fe3+ which can chemically oxidize sulfide minerals. These reactions produce voluminous quantities of acid mine drainage and heavy metals which are harmful to the environment and human healthy. This study aims at finding the weathering effects of A. ferrooxidans to Cu(II) pollution of fine grained copper mine tailings, and our experiment applied indigenous A. ferrooxidans FJ-01 to leach the tailings. The optimum test parameters were obtained using shaking flask experiment and SEM observation under the following experimental conditions: 39 days residence time, pulp density 1%-15% (1%, 5% and 15%), 30℃, 120 rpm, pH between 1-3 and redox potential between 400-650 mV. The test results show that the leaching rate of Cu reached 43.1% when the pulp density was 1% after 33 days and kept invariant till the end of the test. In addition, the leaching rate of Cu will decrease as the increase of pulp density, and the maximum rate of 15% pulp density was only 12.5%. From the SEM, it can be seen that the fine grain of tailings flocculated to conglobation under the action of bacterial leaching.
文摘In order to develop an energy saving electrodeposition process of copper, the electrodeposition of copper in copper sulfate solution by the ion exchange membrane primary cell (IMPC) method has been studied. The experiments were carried out in an ion exchange membrane primary cell with dimensions of 200 mm in length, 52 mm in width and 90 mm in height. The influences of temperature(294 323 K), interval between the anode and cathode (1.5 3.5 cm), mass concentrations of Cu 2+ (6 40 g/L), H 2SO 4(0 120 g/L) and Fe 3+ (3 9 g/L) in catholyte and solution flow rate (0 8 cm/s) on current density and current efficiency were investigated experimentally. The current density increases with the increase of temperature and concentrations of Cu 2+ and H 2SO 4 in catholyte. Cathode current efficiency decreases with the increase of concentration of Fe 3+ in catholyte and anode current efficiency decreases with the increase of temperature. The high quality cathodic copper can be obtained and the current density of membrane can be higher than 150 A/m 2 and the current density of cathode can be higher than 300 A/m 2. The experiment results show that IMPC method is effective for electrodeposition of copper.
基金Project(2014CB643401)supported by the National Basic Research Program of ChinaProjects(51134007,51474256)supported by the National Natural Science Foundation of ChinaProject(2017TP1001)supported by the Hunan Provincial Science and Technology Plan Project,China
文摘This study presents the deep removal of copper (Ⅱ) from the simulated cobalt electrolyte using fabricated polystyrene-supported 2-aminomethylpyridine chelating resin (PS-AMP) in a fixed-bed.The effects of bed height (7.0–14.0 cm),feed flow rate (4.5–9.0 mL/min),initial copper (Ⅱ) concentration of the feed (250–1000 mg/L),feed temperature (25–40 ℃) and the value of pH (2.0–4.0) on the adsorption process of the PS-AMP resin were investigated.The experimental data showed that the PS-AMP resin can deeply eliminate copper (Ⅱ) from the simulated cobalt electrolyte.The bed height,feed flow rate,initial copper (Ⅱ) concentration of the feed,feed temperature and feed pH value which corresponded to the highest removal of copper (Ⅱ) were 7.0 cm with 35 mm of the column diameter,4.5 mL/min,40℃,1000 mg/L and 4.0,respectively.The breakthrough capacity,the saturated capacity of the column and the mass ratio of Cu/Co (g/g) in the saturated resin were correspondingly 16.51 mg/g dry resin,61.72 mg/g dry resin and 37.67 under the optimal experimental conditions.The copper (Ⅱ) breakthrough curves were fitted by the empirical models of Thomas,Yoon-Nelson and Adam-Bohart,respectively.The Thomas model was found to be the most suitable one for predicting how the concentration of copper (Ⅱ) in the effluent changes with the adsorption time.