To guarantee control system's performance and shorten the development cycle during the development process of hydraulic automatic transmission, a calibration system on CAN for high-pow- er AT ECU is designed based on...To guarantee control system's performance and shorten the development cycle during the development process of hydraulic automatic transmission, a calibration system on CAN for high-pow- er AT ECU is designed based on XCP. In this system, it is possible that the master dynamically searching the slaves available on bus and data synchronization between master and slave is also achieved. Real-time measurement and on-line calibration can be executed during the running process of transmission control unit, so the calibration result is displayed in time. Calibration by true value and physical value are both available. Experimental results showed that this system operated stably and reliably and had strong timeout handling ability.展开更多
The high-intensity heavy-ion accelerator facility(HIAF)is a scientific research facility complex composed of multiple cas-cade accelerators of different types,which pose a scheduling problem for devices distributed ov...The high-intensity heavy-ion accelerator facility(HIAF)is a scientific research facility complex composed of multiple cas-cade accelerators of different types,which pose a scheduling problem for devices distributed over a certain range of 2 km,involving over a hundred devices.The white rabbit,a technology-enhancing Gigabit Ethernet,has shown the capability of scheduling distributed timing devices but still faces the challenge of obtaining real-time synchronization calibration param-eters with high precision.This study presents a calibration system based on a time-to-digital converter implemented on an ARM-based System-on-Chip(SoC).The system consists of four multi-sample delay lines,a bubble-proof encoder,an edge controller for managing data from different channels,and a highly effective calibration module that benefits from the SoC architecture.The performance was evaluated with an average RMS precision of 5.51 ps by measuring the time intervals from 0 to 24,000 ps with 120,000 data for every test.The design presented in this study refines the calibration precision of the HIAF timing system.This eliminates the errors caused by manual calibration without efficiency loss and provides data support for fault diagnosis.It can also be easily tailored or ported to other devices for specific applications and provides more space for developing timing systems for particle accelerators,such as white rabbits on HIAF.展开更多
A calibration scheme under spherical coordinates is described for a magnetic tracker used in VR (virtual reality) system. A look up table containing data of tracked values for certain positions in the working space, ...A calibration scheme under spherical coordinates is described for a magnetic tracker used in VR (virtual reality) system. A look up table containing data of tracked values for certain positions in the working space, spe cified in spherical coordinates, is generated first, which is then used to calibrate the tracking results by a two dimensional interpolation. The scheme can effectively correct the static errors in the magnetic tracking system. The employment of spherical coordinates significantly reduces the calculation complexity in calibration.展开更多
The neutron flux monitor(NFM)system is an important diagnostic subsystem introduced by large nuclear fusion devices such as international thermonuclear experimental reactor(ITER),Japan torus-60,tokamak fusion test rea...The neutron flux monitor(NFM)system is an important diagnostic subsystem introduced by large nuclear fusion devices such as international thermonuclear experimental reactor(ITER),Japan torus-60,tokamak fusion test reactor,and HL-2 A.Neutron fluxes can provide real-time parameters for nuclear fusion,including neutron source intensity and fusion power.Corresponding to different nuclear reaction periods,neutron fluxes span over seven decades,thereby requiring electronic devices to operate in counting and Campbelling modes simultaneously.Therefore,it is crucial to design a real-time NFM system to encompass such a wide dynamic range.In this study,a high-precision NFM system with a wide measurement range of neutron flux is implemented using realtime multipoint linear calibration.It can automatically switch between counting and Campbelling modes with variations in the neutron flux.We established a testing platform to verify the feasibility of the NFM system,which can output the simulated neutron signal using an arbitrary waveform generator.Meanwhile,the accurate calibration interval of the Campbelling mode is defined well.Based on the above-mentioned design,the system satisfies the requirements,offering a dynamic range of 10~8 cps,temporal resolution of 1 ms,and maximal relative error of 4%measured at the signal-to-noise ratio of 15.8 dB.Additionally,the NFM system is verified in a field experiment involving HL-2 A,and the measured neutron flux is consistent with the results.展开更多
Camera calibration is a critical process in photogrammetry and a necessary step to acquire 3D information from a 2D image. In this paper, a flexible approach for CCD camera calibration using 2D direct linear transform...Camera calibration is a critical process in photogrammetry and a necessary step to acquire 3D information from a 2D image. In this paper, a flexible approach for CCD camera calibration using 2D direct linear transformation (DLT) and bundle adjustment is proposed. The proposed approach assumes that the camera interior orientation elements are known, and addresses a new closed form solution in planar object space based on homogenous coordinate representation and matrix factorization. Homogeneous coordinate representation offers a direct matrix correspondence between the parameters of the 2D DLT and the collinearity equation. The matrix factorization starts by recovering the elements of the rotation matrix and then solving for the camera position with the collinearity equation. Camera calibration with high precision is addressed by bundle adjustment using the initial values of the camera orientation elements. The results show that the calibration precision of principal point and focal length is about 0.2 and 0.3 pixels respectivelv, which can meet the requirements of close-range photogrammetry with high accuracy.展开更多
A thorough detector response calibration using radioactive sources is necessary for the Jiangmen Underground Neutrino Observatory. Herein, we discuss the design of a source positioning system based on ultrasonic techn...A thorough detector response calibration using radioactive sources is necessary for the Jiangmen Underground Neutrino Observatory. Herein, we discuss the design of a source positioning system based on ultrasonic technology, aiming for a 3-cm precision over the entire35-m diameter detector sphere. A prototype system is constructed and demonstrated for the experiment.展开更多
A computer-based simulation and test system is developed. This system has the following functions: producing the initial control MAP with good accuracy, calibrating the electronic control unit (ECU) on-line, (identify...A computer-based simulation and test system is developed. This system has the following functions: producing the initial control MAP with good accuracy, calibrating the electronic control unit (ECU) on-line, (identifying) the dynamic transfer functions for air/fuel ratio, idle speed and ignition timing control. So the experiment work is reduced and the calibration is accelerated. In order to increase the simulation accuracy of the initial control MAP, the mathematical models are not only based on theoretical equations, but also on the control data of reference working points, which is obtained by the on-line calibration of special engines. The application of this system on a mini-car shows that the simulated control MAP has good accuracy, the interface of the system is friendly, the integrated simulation and test system is a powerful aid for EFI engine calibration and the development speed is accelerated.展开更多
A tangential fast visible camera has been set up in EAST tokamak for the study of edge MHD instabilities such as ELM. To determine the 3-D information from CCD images, Tsai's two-stage technique was utilized to calib...A tangential fast visible camera has been set up in EAST tokamak for the study of edge MHD instabilities such as ELM. To determine the 3-D information from CCD images, Tsai's two-stage technique was utilized to calibrate the high-speed camera imaging system for ELM study. By applying tiles of the passive stabilizers in the tokamak device as the calibration pattern, transformation parameters for transforming from a 3-D world coordinate system to a 2-D image coordinate system were obtained, including the rotation matrix, the translation vector, the focal length and the lens distortion. The calibration errors were estimated and the results indicate the reliability of the method used for the camera imaging system. Through the calibration, some information about ELM filaments, such as positions and velocities were obtained from images of H-mode CCD videos.展开更多
For a practical superconducting quantum interference device(SQUID) based measurement system,the Tesla/volt coefficient must be accurately calibrated.In this paper,we propose a highly efficient method of calibrating ...For a practical superconducting quantum interference device(SQUID) based measurement system,the Tesla/volt coefficient must be accurately calibrated.In this paper,we propose a highly efficient method of calibrating a SQUID magnetometer system using three orthogonal Helmholtz coils.The Tesla/volt coefficient is regarded as the magnitude of a vector pointing to the normal direction of the pickup coil.By applying magnetic fields through a three-dimensional Helmholtz coil,the Tesla/volt coefficient can be directly calculated from magnetometer responses to the three orthogonally applied magnetic fields.Calibration with alternating current(AC) field is normally used for better signal-to-noise ratio in noisy urban environments and the results are compared with the direct current(DC) calibration to avoid possible effects due to eddy current.In our experiment,a calibration relative error of about 6.89 × 10-4is obtained,and the error is mainly caused by the non-orthogonality of three axes of the Helmholtz coils.The method does not need precise alignment of the magnetometer inside the Helmholtz coil.It can be used for the multichannel magnetometer system calibration effectively and accurately.展开更多
Precise measurements of the cavity forward(Vf)and reflected signals(Vr)are essential for characterizing other key parameters such as the cavity detuning and forward power.In practice,it is challenging to measure V_(f)...Precise measurements of the cavity forward(Vf)and reflected signals(Vr)are essential for characterizing other key parameters such as the cavity detuning and forward power.In practice,it is challenging to measure V_(f) and V_(r) precisely because of cross talk between the forward and reflected channels(e.g.,coupling between the cavity reflected and forward signals in a directional coupler with limited directivity).For DESY,a method based on the cavity differential equation was proposed to precisely calibrate the actual V_(f) and V_(r).In this study,we verified the validity and practicability of this approach for the Chinese ADS front-end demo superconducting linac(CAFe)facility at the Institute of Modern Physics and a compact energy recovery linac(cERL)test machine at KEK.At the CAFe facility,we successfully calibrated the actual V_(f) signal using this method.The result demonstrated that the directivity of directional couplers might seriously affect the accuracy of V_(f) measurement.At the cERL facility,we calibrated the Lorentz force detuning(LFD)using the actual Vf.Our study confirmed that the precise calibration of V_(f) significantly improves the accuracy of the cavity LFD measurement.展开更多
A practical calibration method is proposed for instantaneous polarization radar systems.The method only needs one measurement by using a metal sphere.The distortions of system and the actual polarization scattering ma...A practical calibration method is proposed for instantaneous polarization radar systems.The method only needs one measurement by using a metal sphere.The distortions of system and the actual polarization scattering matrix(PSM)of target can be obtained.First,an instantaneous polarization radar system is presented.The system can obtain PSM by a single pulse echo.The dual-polarization antenna can transmit and receive two orthogonal polarization waves.The multilayer micro-strip patch antenna is adopted for this kind of radar system.Second,based on the multi-port network theory,the operation and system errors of instantaneous polarization radar system are analyzed.By making assumption on the cross-talk factors of antenna,distortion matrices of R and Tare derived.Finally,the calibration method based on instantaneous polarization measurement is introduced.Simulation results show the performance of this calibration method.The values of calibrated PSM are in agreement with the actual ones after calibration.展开更多
The ejector-powered engine simulator(EPES)system is an important piece of equipment in conducting an influence test of the intake and jet flow in low-speed wind tunnels.In this work,through the analysis of the structu...The ejector-powered engine simulator(EPES)system is an important piece of equipment in conducting an influence test of the intake and jet flow in low-speed wind tunnels.In this work,through the analysis of the structure and principle of EPES,three parts of the internal flow force were obtained,namely,the additional resistance before the inlet,the internal flow force in the inlet and the thrust produced by the ejector.On the assumption of one-dimensional isentropic adiabatic flow,the theoretical formulae for calculating the forces were derived according to the measured total pressure,static pressure and total temperature of the internal flow section.Subsequently,a calibration tank was used to calibrate the EPES system.On the basis of the characteristics of the EPES system,the process and method of its calibration were designed in detail,and the model installation interface of the calibration tank was reformed.By applying this method,the repeatability accuracy of the inlet flow rate calibration coefficient was less than0.05%,whereas that of the exhaust flow rate and velocity was less than 0.1%.Upon the application of the calibration coefficients to the correction of the wind tunnel experiment data,the results showed good agreement with the numerical simulation results in terms of regularity and magnitude before stall,which validates the reasonableness and feasibility of the calibration method.Analysis of the calibration data also demonstrated the consistency in the variation law and trend between the theoretical calculation and actual measurement of internal flow force,further reflecting the rationality and feasibility of the theoretical calculation.Nevertheless,the numerical difference was large and further widened with a higher ejection flow rate mainly because of the accuracy of flow measurement and the inhomogeneity of internal flow.The thrust deflection angle of EPES is an important factor in correcting this issue.In particular,the thrust deflection angle becomes larger with small ejection flow and becomes smaller with an increase in flow rate,essentially exhibiting a general change of less than 10°.展开更多
A method of micro-scanning location adaptive calibration was proposed, which was real- ized by the digital image micro-displacement estimation. With geometric calculation, this calibration method used the displacement...A method of micro-scanning location adaptive calibration was proposed, which was real- ized by the digital image micro-displacement estimation. With geometric calculation, this calibration method used the displacement estimation of two thermal microscope images to get the size and direc- tion of each scanning location calibration angle. And each location calibration process was repeated according to the offset given by the system beforehand. The comparison experiments of sequence oversampling reconstruction before and after the micro-scanning location calibration were done. The results showed that the calibration method effectively improved the thermal microscope imaging qual- ity.展开更多
A flexible calibration method based on a front-coated flat mirror is proposed for a laser light-sectioning three-dimensional(3D)measurement system. Since the calibration target and its mirror image are spatially separ...A flexible calibration method based on a front-coated flat mirror is proposed for a laser light-sectioning three-dimensional(3D)measurement system. Since the calibration target and its mirror image are spatially separated and can be recorded in an image by a camera,the proposed method requires only a single composite image that contains a non-planar checkerboard pattern,a laser strip projected on the target and their mirror images to complete the calibration of the camera and the laser plane in one step. Levenberg-Marquardt(LM)algorithm is used to optimize the system parameters,and the measurement accuracy and speed are improved to enable online 3D inspection. Static and dynamic online 3D measurements are carried out on a cup and a triple stepped shaft,respectively,to validate the proposed method. The shaft has two steps with the depth of(0.5±0.01)mm and(2±0.01)mm to be measured online when the shaft is rotated and translated at the same time. The measurement results can be output at a frequency of 7 to 11 readings per second with standard deviations of 0.040 mm and 0.051 mm. The experimental results verify the effectiveness and flexibility of the proposed method.展开更多
A vacuum ultraviolet(VUV)spectroscopy with a focal length of 1 m has been engineered specifically for observing edge impurity emissions in Experimental Advanced Superconducting Tokamak(EAST).In this study,wavelength c...A vacuum ultraviolet(VUV)spectroscopy with a focal length of 1 m has been engineered specifically for observing edge impurity emissions in Experimental Advanced Superconducting Tokamak(EAST).In this study,wavelength calibration for the VUV spectroscopy is achieved utilizing a zinc lamp.The grating angle and charge-coupled device(CCD)position are carefully calibrated for different wavelength positions.The wavelength calibration of the VUV spectroscopy is crucial for improving the accuracy of impurity spectral data,and is required to identify more impurity spectral lines for impurity transport research.Impurity spectra of EAST plasmas have also been obtained in the wavelength range of 50–300 nm with relatively high spectral resolution.It is found that the impurity emissions in the edge region are still dominated by low-Z impurities,such as carbon,oxygen,and nitrogen,albeit with the application of fulltungsten divertors on the EAST tokamak.展开更多
Based on error analysis, the influence of error sources on strapdown inertial navigation systems is discussed. And the maximum permissible component tolerances are established. In order to achieve the desired accuracy...Based on error analysis, the influence of error sources on strapdown inertial navigation systems is discussed. And the maximum permissible component tolerances are established. In order to achieve the desired accuracy (defined by circular error probability), the types of appropriate sensors are chosen. The inertial measurement unit (IMU) is composed of those sensors. It is necessary to calibrate the sensors to obtain their error model coefficients of IMU. After calibration tests, the accuracy is calculated by uniform design method and it is proved that the accuracy of IMU is satisfied for the desired goal.展开更多
According to gyro application in micro-satellites, a new gyro bias real-time on-orbit calibration technology is presented and it is independent of any other sensors. The approach relies on gyro on-orbit measurements r...According to gyro application in micro-satellites, a new gyro bias real-time on-orbit calibration technology is presented and it is independent of any other sensors. The approach relies on gyro on-orbit measurements restricted by satellite attitude dynamics and estimates the gyro bias generated when the gyro is electrified. Observability of the calibration model is analyzed and applicable conditions of the technology are derived. Simulation results indicate that the calibration algorithm is accurate and robust at gyro sampling rate, and its convergence speed is fast. Within the given attitude dynamics model error, the convergence time is less than 100 s and the convergence accuracy is about 1.0 (°)/h. Calibration performance can meet requirements of spacecraft operations.展开更多
With respect to the gamma spectrum, the energy resolution improves with increase in energy. The counts of full energy peak change with energy, and this approximately complies with the Gaussian distribution. This study...With respect to the gamma spectrum, the energy resolution improves with increase in energy. The counts of full energy peak change with energy, and this approximately complies with the Gaussian distribution. This study mainly examines a method to deconvolve the LaBr_3:Ce gamma spectrum with a detector response matrix constructing algorithm based on energy resolution calibration.In the algorithm, the full width at half maximum(FWHM)of full energy peak was calculated by the cubic spline interpolation algorithm and calibrated by a square root of a quadratic function that changes with the energy. Additionally, the detector response matrix was constructed to deconvolve the gamma spectrum. Furthermore, an improved SNIP algorithm was proposed to eliminate the background. In the experiment, several independent peaks of ^(152)Eu,^(137)Cs, and ^(60)Co sources were detected by a LaBr_3:Ce scintillator that were selected to calibrate the energy resolution. The Boosted Gold algorithm was applied to deconvolve the gamma spectrum. The results showed that the peak position difference between the experiment and the deconvolution was within ± 2 channels and the relative error of peak area was approximately within 0.96–6.74%. Finally, a ^(133) Ba spectrum was deconvolved to verify the efficiency and accuracy of the algorithm in unfolding the overlapped peaks.展开更多
This study reports the performances of efficiency calibrations for high-purity-germanium gamma-ray spectrometry using the source-, Laboratory Sourceless Object Calibration Software(LabSOCS)-and ANGLE-based methods in ...This study reports the performances of efficiency calibrations for high-purity-germanium gamma-ray spectrometry using the source-, Laboratory Sourceless Object Calibration Software(LabSOCS)-and ANGLE-based methods in an inter-comparison exercise. Although the results of LabSOCS and ANGLE for ^(241)Am emitting lowenergy gamma rays were not very satisfactory, all of the three efficiency calibration methods passed acceptance criteria. The results confirmed the reliability of the calculation codes ANGLE and LabSOCS as alternative efficiency calibration methods in high-purity-germanium gamma spectrometry. This study is likely to promote the further application of the ANGLE and LabSOCS calculation codes in radioactivity measurements.展开更多
Because surface-based monitoring of hydraulic fracturing is not restricted by borehole geometry or the difficulties in maintaining subsurface equipment, it is becoming an increasingly common part of microseismic monit...Because surface-based monitoring of hydraulic fracturing is not restricted by borehole geometry or the difficulties in maintaining subsurface equipment, it is becoming an increasingly common part of microseismic monitoring. The ability to determine an accurate velocity model for the monitored area directly affects the accuracy of microseismic event locations. However, velocity model calibration for location with surface instruments is difficult for several reasons: well log measurements are often inaccurate or incomplete, yielding intractable models; ori- gin times of perforation shots are not always accurate; and the non-uniqueness of velocity models obtained by inver- sion becomes especially problematic when only perforation shots are used. In this paper, we propose a new approach to overcome these limitations. We establish an initial velocity model from well logging data, and then use the root mean square (RMS) error of double-difference arrival times as a proxy measure for the misfit between the well log velocity model and the true velocity structure of the medium. Double-difference RMS errors are reduced by using a very fast simulated annealing for model perturbance, and a sample set of double-difference RMS errors is then selec- ted to determine an empirical threshold. This threshold value is set near the minimum RMS of the selected samples, and an appropriate number of travel times within the threshold range are chosen. The corresponding velocity models are then used to relocate the perforation-shot. We use the velocity model with the smallest relative location errors as the basis for microseismic location. Numerical analysis with exact input velocity models shows that although large differences exist between the calculated and true velocity models, perforation shots can still be located to their actual positions with the proposed technique; the location inaccuracy of the perforation is 〈2 m. Further tests on field data demonstrate the validity of this technique.展开更多
基金Supported by the National High Technology Research and Development Program of China("863" Program)(2012AA111713)
文摘To guarantee control system's performance and shorten the development cycle during the development process of hydraulic automatic transmission, a calibration system on CAN for high-pow- er AT ECU is designed based on XCP. In this system, it is possible that the master dynamically searching the slaves available on bus and data synchronization between master and slave is also achieved. Real-time measurement and on-line calibration can be executed during the running process of transmission control unit, so the calibration result is displayed in time. Calibration by true value and physical value are both available. Experimental results showed that this system operated stably and reliably and had strong timeout handling ability.
基金supported by high-intensity heavy-ion accelerator facility(HIAF)approved by the National Development and Reform Commission of China(2017-000052-73-01-002107)。
文摘The high-intensity heavy-ion accelerator facility(HIAF)is a scientific research facility complex composed of multiple cas-cade accelerators of different types,which pose a scheduling problem for devices distributed over a certain range of 2 km,involving over a hundred devices.The white rabbit,a technology-enhancing Gigabit Ethernet,has shown the capability of scheduling distributed timing devices but still faces the challenge of obtaining real-time synchronization calibration param-eters with high precision.This study presents a calibration system based on a time-to-digital converter implemented on an ARM-based System-on-Chip(SoC).The system consists of four multi-sample delay lines,a bubble-proof encoder,an edge controller for managing data from different channels,and a highly effective calibration module that benefits from the SoC architecture.The performance was evaluated with an average RMS precision of 5.51 ps by measuring the time intervals from 0 to 24,000 ps with 120,000 data for every test.The design presented in this study refines the calibration precision of the HIAF timing system.This eliminates the errors caused by manual calibration without efficiency loss and provides data support for fault diagnosis.It can also be easily tailored or ported to other devices for specific applications and provides more space for developing timing systems for particle accelerators,such as white rabbits on HIAF.
文摘A calibration scheme under spherical coordinates is described for a magnetic tracker used in VR (virtual reality) system. A look up table containing data of tracked values for certain positions in the working space, spe cified in spherical coordinates, is generated first, which is then used to calibrate the tracking results by a two dimensional interpolation. The scheme can effectively correct the static errors in the magnetic tracking system. The employment of spherical coordinates significantly reduces the calculation complexity in calibration.
基金supported by the National Natural Science Foundation of China(Nos.11475131,11975307,and 11575184)the National Magnetic Confinement Fusion Energy Development Research(No.2013GB104003)。
文摘The neutron flux monitor(NFM)system is an important diagnostic subsystem introduced by large nuclear fusion devices such as international thermonuclear experimental reactor(ITER),Japan torus-60,tokamak fusion test reactor,and HL-2 A.Neutron fluxes can provide real-time parameters for nuclear fusion,including neutron source intensity and fusion power.Corresponding to different nuclear reaction periods,neutron fluxes span over seven decades,thereby requiring electronic devices to operate in counting and Campbelling modes simultaneously.Therefore,it is crucial to design a real-time NFM system to encompass such a wide dynamic range.In this study,a high-precision NFM system with a wide measurement range of neutron flux is implemented using realtime multipoint linear calibration.It can automatically switch between counting and Campbelling modes with variations in the neutron flux.We established a testing platform to verify the feasibility of the NFM system,which can output the simulated neutron signal using an arbitrary waveform generator.Meanwhile,the accurate calibration interval of the Campbelling mode is defined well.Based on the above-mentioned design,the system satisfies the requirements,offering a dynamic range of 10~8 cps,temporal resolution of 1 ms,and maximal relative error of 4%measured at the signal-to-noise ratio of 15.8 dB.Additionally,the NFM system is verified in a field experiment involving HL-2 A,and the measured neutron flux is consistent with the results.
基金Project 2005A030 supported by the Youth Science and Research Foundation from China University of Mining & Technology
文摘Camera calibration is a critical process in photogrammetry and a necessary step to acquire 3D information from a 2D image. In this paper, a flexible approach for CCD camera calibration using 2D direct linear transformation (DLT) and bundle adjustment is proposed. The proposed approach assumes that the camera interior orientation elements are known, and addresses a new closed form solution in planar object space based on homogenous coordinate representation and matrix factorization. Homogeneous coordinate representation offers a direct matrix correspondence between the parameters of the 2D DLT and the collinearity equation. The matrix factorization starts by recovering the elements of the rotation matrix and then solving for the camera position with the collinearity equation. Camera calibration with high precision is addressed by bundle adjustment using the initial values of the camera orientation elements. The results show that the calibration precision of principal point and focal length is about 0.2 and 0.3 pixels respectivelv, which can meet the requirements of close-range photogrammetry with high accuracy.
基金supported by the ‘‘Strategic Priority Research Program’’ of the Chinese Academy of Sciences(No.XDA10010800)the ‘‘Fundamental Research Funds for the Central Universities’’(No.3102017zy010)
文摘A thorough detector response calibration using radioactive sources is necessary for the Jiangmen Underground Neutrino Observatory. Herein, we discuss the design of a source positioning system based on ultrasonic technology, aiming for a 3-cm precision over the entire35-m diameter detector sphere. A prototype system is constructed and demonstrated for the experiment.
文摘A computer-based simulation and test system is developed. This system has the following functions: producing the initial control MAP with good accuracy, calibrating the electronic control unit (ECU) on-line, (identifying) the dynamic transfer functions for air/fuel ratio, idle speed and ignition timing control. So the experiment work is reduced and the calibration is accelerated. In order to increase the simulation accuracy of the initial control MAP, the mathematical models are not only based on theoretical equations, but also on the control data of reference working points, which is obtained by the on-line calibration of special engines. The application of this system on a mini-car shows that the simulated control MAP has good accuracy, the interface of the system is friendly, the integrated simulation and test system is a powerful aid for EFI engine calibration and the development speed is accelerated.
基金supported by National Natural Science Foundation of China(No.11275047)the National Magnetic Confinement Fusion Science Program of China(No.2013GB102000)
文摘A tangential fast visible camera has been set up in EAST tokamak for the study of edge MHD instabilities such as ELM. To determine the 3-D information from CCD images, Tsai's two-stage technique was utilized to calibrate the high-speed camera imaging system for ELM study. By applying tiles of the passive stabilizers in the tokamak device as the calibration pattern, transformation parameters for transforming from a 3-D world coordinate system to a 2-D image coordinate system were obtained, including the rotation matrix, the translation vector, the focal length and the lens distortion. The calibration errors were estimated and the results indicate the reliability of the method used for the camera imaging system. Through the calibration, some information about ELM filaments, such as positions and velocities were obtained from images of H-mode CCD videos.
基金Project supported by the“Strategic Priority Research Program(B)”of the Chinese Academy of Sciences(Grant No.XDB04020200)the Shanghai Municipal Science and Technology Commission Project,China(Grant No.15DZ1940902)
文摘For a practical superconducting quantum interference device(SQUID) based measurement system,the Tesla/volt coefficient must be accurately calibrated.In this paper,we propose a highly efficient method of calibrating a SQUID magnetometer system using three orthogonal Helmholtz coils.The Tesla/volt coefficient is regarded as the magnitude of a vector pointing to the normal direction of the pickup coil.By applying magnetic fields through a three-dimensional Helmholtz coil,the Tesla/volt coefficient can be directly calculated from magnetometer responses to the three orthogonally applied magnetic fields.Calibration with alternating current(AC) field is normally used for better signal-to-noise ratio in noisy urban environments and the results are compared with the direct current(DC) calibration to avoid possible effects due to eddy current.In our experiment,a calibration relative error of about 6.89 × 10-4is obtained,and the error is mainly caused by the non-orthogonality of three axes of the Helmholtz coils.The method does not need precise alignment of the magnetometer inside the Helmholtz coil.It can be used for the multichannel magnetometer system calibration effectively and accurately.
基金supported by the project of “studies of intelligent LLRF control algorithms for superconducting RF cavities(No.E129851YR0)”。
文摘Precise measurements of the cavity forward(Vf)and reflected signals(Vr)are essential for characterizing other key parameters such as the cavity detuning and forward power.In practice,it is challenging to measure V_(f) and V_(r) precisely because of cross talk between the forward and reflected channels(e.g.,coupling between the cavity reflected and forward signals in a directional coupler with limited directivity).For DESY,a method based on the cavity differential equation was proposed to precisely calibrate the actual V_(f) and V_(r).In this study,we verified the validity and practicability of this approach for the Chinese ADS front-end demo superconducting linac(CAFe)facility at the Institute of Modern Physics and a compact energy recovery linac(cERL)test machine at KEK.At the CAFe facility,we successfully calibrated the actual V_(f) signal using this method.The result demonstrated that the directivity of directional couplers might seriously affect the accuracy of V_(f) measurement.At the cERL facility,we calibrated the Lorentz force detuning(LFD)using the actual Vf.Our study confirmed that the precise calibration of V_(f) significantly improves the accuracy of the cavity LFD measurement.
文摘A practical calibration method is proposed for instantaneous polarization radar systems.The method only needs one measurement by using a metal sphere.The distortions of system and the actual polarization scattering matrix(PSM)of target can be obtained.First,an instantaneous polarization radar system is presented.The system can obtain PSM by a single pulse echo.The dual-polarization antenna can transmit and receive two orthogonal polarization waves.The multilayer micro-strip patch antenna is adopted for this kind of radar system.Second,based on the multi-port network theory,the operation and system errors of instantaneous polarization radar system are analyzed.By making assumption on the cross-talk factors of antenna,distortion matrices of R and Tare derived.Finally,the calibration method based on instantaneous polarization measurement is introduced.Simulation results show the performance of this calibration method.The values of calibrated PSM are in agreement with the actual ones after calibration.
基金supported by the funda-mental research the Funds of China Aerodynamics Research and Development Center
文摘The ejector-powered engine simulator(EPES)system is an important piece of equipment in conducting an influence test of the intake and jet flow in low-speed wind tunnels.In this work,through the analysis of the structure and principle of EPES,three parts of the internal flow force were obtained,namely,the additional resistance before the inlet,the internal flow force in the inlet and the thrust produced by the ejector.On the assumption of one-dimensional isentropic adiabatic flow,the theoretical formulae for calculating the forces were derived according to the measured total pressure,static pressure and total temperature of the internal flow section.Subsequently,a calibration tank was used to calibrate the EPES system.On the basis of the characteristics of the EPES system,the process and method of its calibration were designed in detail,and the model installation interface of the calibration tank was reformed.By applying this method,the repeatability accuracy of the inlet flow rate calibration coefficient was less than0.05%,whereas that of the exhaust flow rate and velocity was less than 0.1%.Upon the application of the calibration coefficients to the correction of the wind tunnel experiment data,the results showed good agreement with the numerical simulation results in terms of regularity and magnitude before stall,which validates the reasonableness and feasibility of the calibration method.Analysis of the calibration data also demonstrated the consistency in the variation law and trend between the theoretical calculation and actual measurement of internal flow force,further reflecting the rationality and feasibility of the theoretical calculation.Nevertheless,the numerical difference was large and further widened with a higher ejection flow rate mainly because of the accuracy of flow measurement and the inhomogeneity of internal flow.The thrust deflection angle of EPES is an important factor in correcting this issue.In particular,the thrust deflection angle becomes larger with small ejection flow and becomes smaller with an increase in flow rate,essentially exhibiting a general change of less than 10°.
基金Supported by Beijing Natural Science Foundation(4062029)Ministry of Science and Technology Innovation Foundation for Small and Medium-sized Enterprises (06KW1051)North China University of Technology Dr. Start-up Fund for 2013
文摘A method of micro-scanning location adaptive calibration was proposed, which was real- ized by the digital image micro-displacement estimation. With geometric calculation, this calibration method used the displacement estimation of two thermal microscope images to get the size and direc- tion of each scanning location calibration angle. And each location calibration process was repeated according to the offset given by the system beforehand. The comparison experiments of sequence oversampling reconstruction before and after the micro-scanning location calibration were done. The results showed that the calibration method effectively improved the thermal microscope imaging qual- ity.
基金supported in part by the National Natural Science Foundation of China (No. 11802132)the Natural Science Foundation of Jiangsu Province(No.BK20180446)。
文摘A flexible calibration method based on a front-coated flat mirror is proposed for a laser light-sectioning three-dimensional(3D)measurement system. Since the calibration target and its mirror image are spatially separated and can be recorded in an image by a camera,the proposed method requires only a single composite image that contains a non-planar checkerboard pattern,a laser strip projected on the target and their mirror images to complete the calibration of the camera and the laser plane in one step. Levenberg-Marquardt(LM)algorithm is used to optimize the system parameters,and the measurement accuracy and speed are improved to enable online 3D inspection. Static and dynamic online 3D measurements are carried out on a cup and a triple stepped shaft,respectively,to validate the proposed method. The shaft has two steps with the depth of(0.5±0.01)mm and(2±0.01)mm to be measured online when the shaft is rotated and translated at the same time. The measurement results can be output at a frequency of 7 to 11 readings per second with standard deviations of 0.040 mm and 0.051 mm. The experimental results verify the effectiveness and flexibility of the proposed method.
基金partially supported by National Natural Science Foundation of China(Nos.U23A2077,12175278,12205072)the National Magnetic Confinement Fusion Science Program of China(Nos.2019YFE0304002,2018YFE0303103)+2 种基金the Comprehensive Research Facility for Fusion Technology Program of China(No.2018-000052-73-01-001228)Major Science and Technology Infrastructure Maintenance and Reconstruction Projects of the Chinese Academy of Sciences(2021)the University Synergy Innovation Program of Anhui Province(No.GXXT2021-029)。
文摘A vacuum ultraviolet(VUV)spectroscopy with a focal length of 1 m has been engineered specifically for observing edge impurity emissions in Experimental Advanced Superconducting Tokamak(EAST).In this study,wavelength calibration for the VUV spectroscopy is achieved utilizing a zinc lamp.The grating angle and charge-coupled device(CCD)position are carefully calibrated for different wavelength positions.The wavelength calibration of the VUV spectroscopy is crucial for improving the accuracy of impurity spectral data,and is required to identify more impurity spectral lines for impurity transport research.Impurity spectra of EAST plasmas have also been obtained in the wavelength range of 50–300 nm with relatively high spectral resolution.It is found that the impurity emissions in the edge region are still dominated by low-Z impurities,such as carbon,oxygen,and nitrogen,albeit with the application of fulltungsten divertors on the EAST tokamak.
文摘Based on error analysis, the influence of error sources on strapdown inertial navigation systems is discussed. And the maximum permissible component tolerances are established. In order to achieve the desired accuracy (defined by circular error probability), the types of appropriate sensors are chosen. The inertial measurement unit (IMU) is composed of those sensors. It is necessary to calibrate the sensors to obtain their error model coefficients of IMU. After calibration tests, the accuracy is calculated by uniform design method and it is proved that the accuracy of IMU is satisfied for the desired goal.
文摘According to gyro application in micro-satellites, a new gyro bias real-time on-orbit calibration technology is presented and it is independent of any other sensors. The approach relies on gyro on-orbit measurements restricted by satellite attitude dynamics and estimates the gyro bias generated when the gyro is electrified. Observability of the calibration model is analyzed and applicable conditions of the technology are derived. Simulation results indicate that the calibration algorithm is accurate and robust at gyro sampling rate, and its convergence speed is fast. Within the given attitude dynamics model error, the convergence time is less than 100 s and the convergence accuracy is about 1.0 (°)/h. Calibration performance can meet requirements of spacecraft operations.
基金supported by the National Natural Science Foundation of China(Nos.41374130 and 41604154)
文摘With respect to the gamma spectrum, the energy resolution improves with increase in energy. The counts of full energy peak change with energy, and this approximately complies with the Gaussian distribution. This study mainly examines a method to deconvolve the LaBr_3:Ce gamma spectrum with a detector response matrix constructing algorithm based on energy resolution calibration.In the algorithm, the full width at half maximum(FWHM)of full energy peak was calculated by the cubic spline interpolation algorithm and calibrated by a square root of a quadratic function that changes with the energy. Additionally, the detector response matrix was constructed to deconvolve the gamma spectrum. Furthermore, an improved SNIP algorithm was proposed to eliminate the background. In the experiment, several independent peaks of ^(152)Eu,^(137)Cs, and ^(60)Co sources were detected by a LaBr_3:Ce scintillator that were selected to calibrate the energy resolution. The Boosted Gold algorithm was applied to deconvolve the gamma spectrum. The results showed that the peak position difference between the experiment and the deconvolution was within ± 2 channels and the relative error of peak area was approximately within 0.96–6.74%. Finally, a ^(133) Ba spectrum was deconvolved to verify the efficiency and accuracy of the algorithm in unfolding the overlapped peaks.
基金supported by the Support Program of the Ministry of Science and Technology(No.2014FY211000)the National Key Technology Research and Development Program(No.2013BAK03B05)
文摘This study reports the performances of efficiency calibrations for high-purity-germanium gamma-ray spectrometry using the source-, Laboratory Sourceless Object Calibration Software(LabSOCS)-and ANGLE-based methods in an inter-comparison exercise. Although the results of LabSOCS and ANGLE for ^(241)Am emitting lowenergy gamma rays were not very satisfactory, all of the three efficiency calibration methods passed acceptance criteria. The results confirmed the reliability of the calculation codes ANGLE and LabSOCS as alternative efficiency calibration methods in high-purity-germanium gamma spectrometry. This study is likely to promote the further application of the ANGLE and LabSOCS calculation codes in radioactivity measurements.
基金supported by the National Natural Science Foundation of China(No.41074074)
文摘Because surface-based monitoring of hydraulic fracturing is not restricted by borehole geometry or the difficulties in maintaining subsurface equipment, it is becoming an increasingly common part of microseismic monitoring. The ability to determine an accurate velocity model for the monitored area directly affects the accuracy of microseismic event locations. However, velocity model calibration for location with surface instruments is difficult for several reasons: well log measurements are often inaccurate or incomplete, yielding intractable models; ori- gin times of perforation shots are not always accurate; and the non-uniqueness of velocity models obtained by inver- sion becomes especially problematic when only perforation shots are used. In this paper, we propose a new approach to overcome these limitations. We establish an initial velocity model from well logging data, and then use the root mean square (RMS) error of double-difference arrival times as a proxy measure for the misfit between the well log velocity model and the true velocity structure of the medium. Double-difference RMS errors are reduced by using a very fast simulated annealing for model perturbance, and a sample set of double-difference RMS errors is then selec- ted to determine an empirical threshold. This threshold value is set near the minimum RMS of the selected samples, and an appropriate number of travel times within the threshold range are chosen. The corresponding velocity models are then used to relocate the perforation-shot. We use the velocity model with the smallest relative location errors as the basis for microseismic location. Numerical analysis with exact input velocity models shows that although large differences exist between the calculated and true velocity models, perforation shots can still be located to their actual positions with the proposed technique; the location inaccuracy of the perforation is 〈2 m. Further tests on field data demonstrate the validity of this technique.