期刊文献+
共找到19,997篇文章
< 1 2 250 >
每页显示 20 50 100
Role of outdoor trees on pedestrian wind and thermal conditions around a pre-education building for sustainable energy management
1
作者 LI Xiao-jie TANG Hui-li 《Journal of Central South University》 SCIE EI CAS CSCD 2024年第6期2039-2053,共15页
Finding sustainable energy resources is essential to face the increasing energy demand.Trees are an important part of ancient architecture but are becoming rare in urban areas.Trees can control and tune the pedestrian... Finding sustainable energy resources is essential to face the increasing energy demand.Trees are an important part of ancient architecture but are becoming rare in urban areas.Trees can control and tune the pedestrian-level wind velocity and thermal condition.In this study,a numerical investigation is employed to assess the role of trees planted in the windward direction of the building complex on the thermal and pedestrian wind velocity conditions around/inside a pre-education building located in the center of the complex.Compared to the previous studies(which considered only outside buildings),this work considers the effects of trees on microclimate change both inside/outside buildings.Effects of different parameters including the leaf area density and number of trees,number of rows,far-field velocity magnitude,and thermal condition around the main building are assessed.The results show that the flow velocity in the spacing between the first-row buildings is reduced by 30%-40% when the one-row trees with 2 m height are planted 15 m farther than the buildings.Furthermore,two rows of trees are more effective in higher velocities and reduce the maximum velocity by about 50%.The investigation shows that trees also could reduce the temperature by about 1℃around the building. 展开更多
关键词 sustainable management energy trees urban area thermal condition building
在线阅读 下载PDF
Intelligent prediction model of tunnelling-induced building deformation based on genetic programming and its application
2
作者 XU Jing-min WANG Chen-cheng +3 位作者 CHENG Zhi-liang XU Tao ZHANG Ding-wen LI Zi-li 《Journal of Central South University》 CSCD 2024年第11期3885-3899,共15页
This paper aims to explore the ability of genetic programming(GP)to achieve the intelligent prediction of tunnelling-induced building deformation considering the multifactor impact.A total of 1099 groups of data obtai... This paper aims to explore the ability of genetic programming(GP)to achieve the intelligent prediction of tunnelling-induced building deformation considering the multifactor impact.A total of 1099 groups of data obtained from 22 geotechnical centrifuge tests are used for model development and analysis using GP.Tunnel volume loss,building eccentricity,soil density,building transverse width,building shear stiffness and building load are selected as the inputs,and shear distortion is selected as the output.Results suggest that the proposed intelligent prediction model is capable of providing a reasonable and accurate prediction of framed building shear distortion due to tunnel construction with realistic conditions,highlighting the important roles of shear stiffness of framed buildings and the pressure beneath the foundation on structural deformation.It has been proven that the proposed model is efficient and feasible to analyze relevant engineering problems by parametric analysis and comparative analysis.The findings demonstrate the great potential of GP approaches in predicting building distortion caused by tunnelling.The proposed equation can be used for the quick and intelligent prediction of tunnelling induced building deformation,providing valuable guidance for the practical design and risk assessment of urban tunnel construction projects. 展开更多
关键词 building deformation genetic programming tunnel construction modification factor
在线阅读 下载PDF
GF(2)上的三角Building
3
作者 夏建国 《南京师大学报(自然科学版)》 CAS CSCD 1998年第3期9-11,共3页
证明了GF(2)上的4个三角building是两两彼此不同构的.
关键词 building Blueprint 典则标签 正则自同构群
在线阅读 下载PDF
计算机辅助建筑设计(CAAD)的发展趋势——虚拟建筑(Virtual Building)设计将成为主流 被引量:19
4
作者 曾旭东 赵昂 《重庆建筑大学学报》 EI CSCD 北大核心 2006年第1期21-24,共4页
通过对计算机辅助设计CAD和计算机辅助建筑设计CAAD技术发展历程的回顾,结合CAAD技术在建筑设计领域的应用现状,深入分析了“虚拟建筑”设计方法的原理和优势,论述了计算机辅助建筑设计(CAAD)的发展趋势。虚拟建筑(V irtual Build ing)... 通过对计算机辅助设计CAD和计算机辅助建筑设计CAAD技术发展历程的回顾,结合CAAD技术在建筑设计领域的应用现状,深入分析了“虚拟建筑”设计方法的原理和优势,论述了计算机辅助建筑设计(CAAD)的发展趋势。虚拟建筑(V irtual Build ing)模型是一个包含了建筑所有信息的综合数据库,这个数据库不仅可以用于建筑设计,还可以用于结构设计、设备管理、工程量统计、成本计算、物业管理等,可以在整个建筑业中发挥作用,管理建筑生命周期的全部信息。 展开更多
关键词 计算机辅助建筑设计 虚拟建筑 发展趋势
在线阅读 下载PDF
BuildingEXODUS在优化建筑安全疏散设计中的应用 被引量:5
5
作者 田玉敏 《消防科学与技术》 CAS 北大核心 2014年第4期380-383,共4页
利用模拟软件BuildingEXODUS对存在安全隐患的某剧院五层包厢的疏散设计进行了模拟,针对不同疏散设计方案的关键参数分别进行了模拟计算,包括疏散时间、死亡人数、跳跃座位次数、疏散出口的有效性等。结果表明:增加疏散通道的宽度可以... 利用模拟软件BuildingEXODUS对存在安全隐患的某剧院五层包厢的疏散设计进行了模拟,针对不同疏散设计方案的关键参数分别进行了模拟计算,包括疏散时间、死亡人数、跳跃座位次数、疏散出口的有效性等。结果表明:增加疏散通道的宽度可以减少疏散时间、降低人员伤亡。增加疏散出口的数量可以有效降低疏散时间和跳跃座位的次数,避免火灾对人群疏散的影响。五层包厢增加两个出口的设计为最优设计。 展开更多
关键词 安全疏散 优化设计 模拟计算
在线阅读 下载PDF
MIDAS/Building双塔大跨度连体建筑抗震设计 被引量:5
6
作者 杨子胜 李新明 杨毅辉 《中国测试》 CAS 北大核心 2016年第6期80-84,共5页
双塔大跨度连体建筑结构形式及受力较为复杂,其结构安全性设计特别是抗震设计尤为重要。以某双塔大跨度连体建筑为例,基于MIDAS/Building结构分析设计系统及SATWE对整体结构进行小震反应谱分析,考虑施工模拟及P-delta影响,计算其水平及... 双塔大跨度连体建筑结构形式及受力较为复杂,其结构安全性设计特别是抗震设计尤为重要。以某双塔大跨度连体建筑为例,基于MIDAS/Building结构分析设计系统及SATWE对整体结构进行小震反应谱分析,考虑施工模拟及P-delta影响,计算其水平及竖向地震作用,得到整体结构受力与位移参数,并进行设计验算。通过比较两种软件计算结果,可以看出该工程各项指标均符合规范要求,具有良好的抗震性能。基于计算结果,提出一些改进措施,为类似结构的计算与抗震性能分析提供参考。 展开更多
关键词 双塔 大跨度连体建筑 抗震设计 小震反应谱法
在线阅读 下载PDF
基于nightly building的软PLC自动测试系统 被引量:1
7
作者 范卫华 安连生 +1 位作者 幺开宇 丁玮 《制造技术与机床》 CSCD 北大核心 2005年第10期52-54,共3页
从每夜构建的思想出发,为凯奇数控设备成套有限公司自主研发的软PLC开发系统建立了一套自动测试系统,用来自动测试软PLC的所有元件功能的正确性。
关键词 软PLC 每夜构建 自动测试 仿真 状态流 自动测试系统 building 系统建立 自主研发 有限公司
在线阅读 下载PDF
A primary study of the acoustics of Chinese traditional theatrical buildings 被引量:3
8
作者 WANG Jiqing (Institute of Acoustics, Tongji University, Shanghai 200092, China ) 《声学技术》 CSCD 2003年第z1期2-5,共4页
The traditional performing arts and theatrical buildings in China can be traced back to a long history and were well developed during Song and Yuan Dynasties, 11th-14th centuries. Pavilion stage, opened on three sides... The traditional performing arts and theatrical buildings in China can be traced back to a long history and were well developed during Song and Yuan Dynasties, 11th-14th centuries. Pavilion stage, opened on three sides and thrusting into the audience area, was unique and the most popular form in the open-air theatres, the courtyard theatres, and the indoor theatres up to the present day. As the traditional Chinese opera is performed in an abstract way, no stage settings are required and used. Therefore, the pavilion stage including the flat or domed ceiling and the back wall is virtually functioned as a reflective shell, which increases the early reflections and also intensifies the sound in the audience area. Meanwhile, it provides sufficient self-support to the performers. Acoustical parameters including reverberation time RT, early decay time EDT, acoustic ratio C (50), strength index (loudness) G, and stage support factor ST1 were measured and reported on several traditional theatrical buildings. 展开更多
关键词 AUDITORIUM acoustics theatrical building ACOUSTICS of TRADITIONAL PERFORMANCE
在线阅读 下载PDF
Development of Temperature-Humidity Independent Control Air-Conditioning Unit for Residential Buildings 被引量:3
9
作者 HAN Xing1,ZHANG Xu1,LIU Jin-tao2,GAO Si-yun2,KANG Yue2(1.Institute of HVAC & Gas,College of Mechanical Engineering,Tongji University,Shanghai 200092,China 2.Hisense R&D Center,Qingdao,266000,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期83-87,共5页
Cooling panels are increasingly used in domestic residential buildings.To provide medium temperature cold water for the cooling panel,and dehumidify the indoor air simultaneously,a new kind of temperature-humidity ind... Cooling panels are increasingly used in domestic residential buildings.To provide medium temperature cold water for the cooling panel,and dehumidify the indoor air simultaneously,a new kind of temperature-humidity independent control air-conditioning unit was developed for single residential house by utilizing multi-variable technology.First,the supply air temperature was studied to determine the proper supply air flow rate for the humidity control.Then,the energy consumption of different temperature-humidity independent control systems was studied.The analysis indicates that unity evaporating temperature can be used to handle the moisture load and sensible heat load in two evaporators.So the unit scheme was put forward.Two evaporators were used to produce medium temperature water and dry air separately,and electric expansion valves were used to control the refrigerant distribution between the two evaporators.Then,experimental work was carried out to investigate the influence of compressor frequency,refrigerant distribution on the dehumidification capacity,energy efficiency and refrigeration capacity.In the end,the paper concludes that both compressor frequency and refrigerant distribution can control the dehumidification capacity,but the former influences the EER more than the latter,while the latter influences the refrigeration capacity more than the former.We can find a proper running point at certain sensible and latent cooling load by adjusting both compressor frequency and electric expansion valve.The energy consumption of this kind of unit was estimated and compared with present room air conditioners,which shows that it can save about 41% cooling energy consumption. 展开更多
关键词 temperature-humidity INDEPENDENT control RESIDENTIAL buildingS COLD DEHUMIDIFICATION experimental study
在线阅读 下载PDF
Impact of light-weight external thermal insulation materials on building surrounding thermal environment in summer 被引量:6
10
作者 李楠 罗国志 +1 位作者 李百战 黄彦祺 《Journal of Central South University》 SCIE EI CAS 2012年第6期1639-1644,共6页
The method for calculating wall surface heat storage coefficient was introduced,and the coefficients of several common walls with light-weight external thermal insulation materials and the traditional solid clay brick... The method for calculating wall surface heat storage coefficient was introduced,and the coefficients of several common walls with light-weight external thermal insulation materials and the traditional solid clay brick wall were calculated.In order to study the impact of light-weight external thermal insulation materials,a contrasting experiment was carried out between an external insulated room and an uninsulated room in August,2010,in Chongqing,China.The result shows that outside surface heat storage coefficient of the insulated wall is much less than that of the traditional wall.However,during sunny time,the surface temperature of external walls of the insulated room is obviously higher than that of the uninsulated room.In different orientations,due to different amounts of solar radiation and being irradiated in different time,the contrasting temperature difference(CTD) appears different regularity.In a word,using light-weight external thermal insulation materials has a negative impact on building surrounding thermal environment and people's health.Finally,some suggestions on how to eliminate the impact,such as improving the surface condition of the building envelop,and plating vertical greening,are put forward. 展开更多
关键词 surface heat storage coefficient external thermal insulation building thermal environment building envelop
在线阅读 下载PDF
Analysis and forecast of residential building energy consumption in Chongqing on carbon emissions 被引量:2
11
作者 李沁 刘猛 钱发 《Journal of Central South University》 SCIE EI CAS 2009年第S1期214-218,共5页
Carbon emissions mainly result from energy consumption. Carbon emissions inevitably will increase to some extent with economic expansion and rising energy consumption. We introduce a gray theory of quantitative analys... Carbon emissions mainly result from energy consumption. Carbon emissions inevitably will increase to some extent with economic expansion and rising energy consumption. We introduce a gray theory of quantitative analysis of the energy consumption of residential buildings in Chongqing,China,on the impact of carbon emission factors. Three impacts are analyzed,namely per capita residential housing area,domestic water consumption and the rate of air conditioner ownership per 100 urban households. The gray prediction model established using the Chongqing carbon emission-residential building energy consumption forecast model is sufficiently accurate to achieve a measure of feasibility and applicability. 展开更多
关键词 carbon emissions FACTOR analysis GRAY prediction model RESIDENTIAL building energy CONSUMPTION
在线阅读 下载PDF
Weighting indicators of building energy efficiency assessment taking account of experts' priority 被引量:10
12
作者 杨玉兰 邰惠鑫 施韬 《Journal of Central South University》 SCIE EI CAS 2012年第3期803-808,共6页
Analytic hierarchy process(Group AHP) is combined with two different methods of assigning experts' priority to weight indicators in building energy efficiency assessment.One is to assign the experts' priority ... Analytic hierarchy process(Group AHP) is combined with two different methods of assigning experts' priority to weight indicators in building energy efficiency assessment.One is to assign the experts' priority averagely,and the other is to use cluster analysis to assign experts' priority.The results show that,1) Different expert's priority assigns result in great different weights of indicators in building energy efficiency assessment,therefore,the method of assigning experts' priority should be taken into account carefully while weighting indicators of building energy efficiency assessment using Group AHP;2) Three indicators are found to be overwhelmingly important in residential building energy efficiency assessment in the hot summer and cold winter zone in China.They are 'Outdoor & indoor shadow','Heating & air-conditioning facilities' and 'Insulation of envelope';3) The method combining cluster analysis with Group AHP to weight indicator of building energy efficiency assessment has the advantage of finding overwhelming important indicator,whereas,some less important indicators have a tendency to be ignored.A useful reference is provided for building energy conservation including policy revision and energy efficient residential building design. 展开更多
关键词 energy efficiency building weighting cluster analysis analytic hierarchy process
在线阅读 下载PDF
A case study of excessive vibrations inside buildings due to an underground railway:Experimental tests and theoretical analysis 被引量:7
13
作者 MING Xuan-hui ZHENG Jun-yuan +3 位作者 WANG Liu-chong ZHAO Cai-you WANG Ping YAO Li 《Journal of Central South University》 SCIE EI CAS CSCD 2022年第1期313-330,共18页
Excessive vibrations inside buildings in the Lihu New Village caused by the Shenzhen Metro Line 2 underground railway were investigated by conducting analyses of the tunnel,the track irregularities,the stiffness of th... Excessive vibrations inside buildings in the Lihu New Village caused by the Shenzhen Metro Line 2 underground railway were investigated by conducting analyses of the tunnel,the track irregularities,the stiffness of the fastening system,and the vibrations of the track system and the building at different speeds.A numerical simulation based on the dynamic coupling theory of the vehicle-track system was used to verify the experimental results.Suitable countermeasures were investigated.The results show that rail corrugation is the primary reason for the excessive vibration,and an increase in the stiffness of the vertical fastening system is the secondary reason.The solution was to eliminate the rail corrugation using rail grinding and decrease the vertical stiffness by changing the fastening system.The results of this study provide references for solving vibration problems caused by rail lines. 展开更多
关键词 excessive vibration buildingS underground railway experimental investigation numerical simulation
在线阅读 下载PDF
Assessment of green roof performance for sustainable buildings under winter weather conditions 被引量:2
14
作者 J.Srebric 《Journal of Central South University》 SCIE EI CAS 2012年第3期639-644,共6页
A green roof is a specialized roof system that supports vegetation growth on rooftops.This technology is rapidly gaining popularity as a sustainable design option for buildings.In order to contribute to an understandi... A green roof is a specialized roof system that supports vegetation growth on rooftops.This technology is rapidly gaining popularity as a sustainable design option for buildings.In order to contribute to an understanding of green roof in regions with cold winters and snow,an on-site experimental investigation was present with a focus on the assessment of green roof performance during the winter.This field experiment took place on a six small buildings during the winter of 2010-2011.The work monitored three buildings with green roofs,two buildings with reference roofs and one building with a bare soil coverage for the roof.These six buildings were identically constructed and instrumented with sensor networks to provide heat flux data through the roofs.The 15 min averaged data were statistically analyzed for a week under the two separate periods,first without a snow cover and second with a snow cover.The results show that the roof type is a significant factor in affecting the thermal performance of these buildings.Most importantly,green roofs reduce heat flow through the roof and thus reduce the heating energy demand during the winter.However,the energy savings for buildings with the green roofs are reduced under snow conditions because the snow diminishes thermal resistance of the roof and increases the heat transfer process through the roofs. 展开更多
关键词 green roof energy savings building envelop sustainable buildings
在线阅读 下载PDF
Impact of mechanical ventilation control strategies based on non-steady-state and steady-state Wells-Riley models on airborne transmission and building energy consumption 被引量:2
15
作者 SHA Hao-han ZHANG Xin QI Da-hai 《Journal of Central South University》 SCIE EI CAS CSCD 2022年第7期2415-2430,共16页
Ventilation is an effective solution for improving indoor air quality and reducing airborne transmission.Buildings need sufficient ventilation to maintain a low infection risk but also need to avoid an excessive venti... Ventilation is an effective solution for improving indoor air quality and reducing airborne transmission.Buildings need sufficient ventilation to maintain a low infection risk but also need to avoid an excessive ventilation rate,which may lead to high energy consumption.The Wells-Riley(WR)model is widely used to predict infection risk and control the ventilation rate.However,few studies compared the non-steady-state(NSS)and steady-state(SS)WR models that are used for ventilation control.To fill in this research gap,this study investigates the effects of the mechanical ventilation control strategies based on NSS/SS WR models on the required ventilation rates to prevent airborne transmission and related energy consumption.The modified NSS/SS WR models were proposed by considering many parameters that were ignored before,such as the initial quantum concentration.Based on the NSS/SS WR models,two new ventilation control strategies were proposed.A real building in Canada is used as the case study.The results indicate that under a high initial quantum concentration(e.g.,0.3 q/m^(3))and no protective measures,SS WR control underestimates the required ventilation rate.The ventilation energy consumption of NSS control is up to 2.5 times as high as that of the SS control. 展开更多
关键词 building ventilation Wells-Riley model building energy consumption airborne transmission
在线阅读 下载PDF
Pedestrian environment prediction with different types of on-shore building distribution 被引量:6
16
作者 宋晓程 刘京 余磊 《Journal of Central South University》 SCIE EI CAS CSCD 2016年第4期955-968,共14页
The aim of this work is to evaluate how the building distribution influences the cooling effect of water bodies. Different turbulence models, including the S-A, SKE, RNG, Realizable, Low-KE and RSM model, were evaluat... The aim of this work is to evaluate how the building distribution influences the cooling effect of water bodies. Different turbulence models, including the S-A, SKE, RNG, Realizable, Low-KE and RSM model, were evaluated, and the CFD results were compared with wind tunnel experiment. The effects of the water body were detected by analyzing the water vapor distribution around it. It is found that the RNG model is the most effective model in terms of accuracy and computational economy. Next, the RNG model was used to simulate four waterfront planning cases to predict the wind, thermal and moisture environment in urban areas around urban water bodies. The results indicate that the building distribution, especially the height of the frontal building, has a larger effect on the water vapor dispersion, and indicate that the column-type distribution has a better performance than the enclosed-type distribution. 展开更多
关键词 CFD simulation micro-climate unban water body building distribution
在线阅读 下载PDF
Country-level meteorological parameters for building energy efficiency in China 被引量:3
17
作者 LIU Yan WANG Shang-yu +2 位作者 CAO Qi-meng LU Mei YANG Liu 《Journal of Central South University》 SCIE EI CAS CSCD 2022年第7期2301-2316,共16页
Accurate basic data are necessary to support performance-based design for achieving carbon peak and carbon neutral targets in the building sector.Meteorological parameters are the prerequisites of building thermal eng... Accurate basic data are necessary to support performance-based design for achieving carbon peak and carbon neutral targets in the building sector.Meteorological parameters are the prerequisites of building thermal engineering design,heating ventilation and air conditioning design,and energy consumption simulations.Focusing on the key issues such as low spatial coverage and the lack of daily or higher time resolution data,daily and hourly models of the surface meteorological data and solar radiation were established and evaluated.Surface meteorological data and solar radiation data were generated for 1019 cities and towns in China from 1988 to 2017.The data were carefully compared,and the accuracy was proved to be high.All the meteorological parameters can be assessed in the building sector via a sharing platform.Then,country-level meteorological parameters were developed for energy-efficient building assessment in China,based on actual meteorological data in the present study.This set of meteorological parameters may facilitate engineering applications as well as allowing the updating and expansion of relevant building energy efficiency standards.The study was supported by the National Science and Technology Major Project of China during the 13th Five-Year Plan Period,named Fundamental parameters on building energy efficiency in China,comprising of 15 top-ranking universities and institutions in China. 展开更多
关键词 building energy efficiency building thermal engineering heating ventilation and air conditioning meteorological parameters solar radiation
在线阅读 下载PDF
Fuzzy-AHP-Based Comprehensive Evaluation on Facility Management System of High-Rise Office Buildings 被引量:2
18
作者 ZHANG Peihong,WANG Kan,WAN Huanhuan,MA Zhongjiao(School of Environment Engineering,Shenyang Jianzhu University,Shenyang,China,110168) 《沈阳建筑大学学报(自然科学版)》 CAS 北大核心 2011年第2期324-330,共7页
The present building facility management status in China resulted in many problems such as high energy consumption,failure of automation control,services failure and poor indoor air quality.Based on questionnaires and... The present building facility management status in China resulted in many problems such as high energy consumption,failure of automation control,services failure and poor indoor air quality.Based on questionnaires and interviews to professional engineers and building users,a comprehensive evaluation index system was established on facility management of high-rise office buildings.A Fuzzy AHP based upon hierarchy criteria system was established.A Fuzzy AHP Evaluation Model on Facility Management System was set up;α-cut analysis was introduced and incorporated with expert knowledge together,which made up the optimism index λ.The fuzzy optimum crisp weight of each criterion was resulted from data-mining.Case investigations were processed in high-rise office buildings in Shenyang.The results illustrated that indoor air quality,thermal comfort and life cycle cost were the most important indexes in the evaluation of Facility Management System of high rise office buildings.Residents in high-rise buildings in Shenyang pay less attention to maintenance management and environment protection.By comparison with the analysis result of Export Choice,Fuzzy AHP-based evaluation model could act as a scientific reference for the establishment of governmental standards in facility management area in building. 展开更多
关键词 building facility management evaluation index Fuzzy AHP indoor air quality thermal comfort
在线阅读 下载PDF
Selection of Weather Parameters for Air-Conditioning System Design for Buildings with Long Thermal Lag 被引量:1
19
作者 GE Lian-feng1,2,LEI Ming3,CHEN You-ming1,2(1.College of Civil Engineering,Hunan University,Changsha,Hunan 410082,China 2.Key Laboratory of Building Safety and Energy Efficiency,MOE,China (3.Aviation Theory Department,Aviation University of Air Force,Changchun,Jilin 130022,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期79-82,共4页
Two building factors-a longer thermal lag of more than one hour for building envelops and a lag of indoor radiation to convert into cooling load-have impact on the instantaneous heat input and instantaneous cooling lo... Two building factors-a longer thermal lag of more than one hour for building envelops and a lag of indoor radiation to convert into cooling load-have impact on the instantaneous heat input and instantaneous cooling load.So the two factors should be taken into account when selecting the weather parameters for air-conditioning system design.This paper developed a new statistic method for the rational selection of coincident solar irradiance,dry-bulb and wet-bulb temperatures.The method was applied to historic weather records of 25 years in Hong Kong to generate coincident design weather data.And the results show that traditional design solar irradiance,dry-bulb and wet-bulb temperatures may be significantly overestimated in many conditions,and the design weather data for the three different constructions is not kept constant. 展开更多
关键词 building construction THERMAL LAG system capacity design WEATHER data AIR-CONDITIONING
在线阅读 下载PDF
基于Midas Building软件的某超限结构抗震性能研究 被引量:2
20
作者 徐秀凤 孔子昂 《工程抗震与加固改造》 北大核心 2018年第6期81-88,共8页
本文采用Midas Building软件对某楼板不连续、扭转及凹凸不规则的超限框剪结构进行抗震性能研究,文中首先将Midas模型与PKPM模型得到的周期、位移及基底剪力的结果进行对比,以验证Midas模型的正确性,从而对此结构进行中震及大震下的弹... 本文采用Midas Building软件对某楼板不连续、扭转及凹凸不规则的超限框剪结构进行抗震性能研究,文中首先将Midas模型与PKPM模型得到的周期、位移及基底剪力的结果进行对比,以验证Midas模型的正确性,从而对此结构进行中震及大震下的弹塑性时程分析。分析表明:结构在中震和大震时,层间位移角最大值分别为0.00177和0.00373,满足性能目标的要求;支撑在各工况下只发生轻微开裂并未屈服,加强区首层框架柱在大震和中震下有57%和35%发生屈服但仍留有足够的安全储备,加强区首层剪力墙边缘约束构件有71.2%发生屈服,但损伤较为分散且均匀,可知各构件均满足性能目标的要求。 展开更多
关键词 MIDAS building 超限框剪结构 时程分析
在线阅读 下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部