Prevailing ambient wind is the main reason thatcauses inlet flow rate(air mass flow rate)decreasingand air flowing backward to the air-cooled condenserfans upward to the wind,hence a set of wind guidingnets is designe...Prevailing ambient wind is the main reason thatcauses inlet flow rate(air mass flow rate)decreasingand air flowing backward to the air-cooled condenserfans upward to the wind,hence a set of wind guidingnets is designed to improve the detrimental effect.Fig.1 shows four typical units of a 1000MW directair-cooled condenser(DACC)and a set of windguiding nets installed under its edge upward to theambient wind.As shown in Fig.2,the fan inlet flowrate decreases as the prevailing ambient wind velocityincreasing,especially for the first two units upward tothe wind.展开更多
A statistical signal processing technique was proposed and verified as independent component analysis(ICA) for fault detection and diagnosis of industrial systems without exact and detailed model.Actually,the aim is t...A statistical signal processing technique was proposed and verified as independent component analysis(ICA) for fault detection and diagnosis of industrial systems without exact and detailed model.Actually,the aim is to utilize system as a black box.The system studied is condenser system of one of MAPNA's power plants.At first,principal component analysis(PCA) approach was applied to reduce the dimensionality of the real acquired data set and to identify the essential and useful ones.Then,the fault sources were diagnosed by ICA technique.The results show that ICA approach is valid and effective for faults detection and diagnosis even in noisy states,and it can distinguish main factors of abnormality among many diverse parts of a power plant's condenser system.This selectivity problem is left unsolved in many plants,because the main factors often become unnoticed by fault expansion through other parts of the plants.展开更多
The operating theory of an evaporative condenser was expatiated.The difference between an evaporative condensing refrigeration system and a general refrigeration system was analyzed.Compared with the air-cooled and th...The operating theory of an evaporative condenser was expatiated.The difference between an evaporative condensing refrigeration system and a general refrigeration system was analyzed.Compared with the air-cooled and the water-cooled,the virtues of energy-conservation and water-conservation of evaporative condensers were analyzed.Some questions existing in the application of evaporative condensers were pointed out,the corresponding solving methods were analyzed accordingly,and the development trend of evaporative condensing technique in mechanical refrigeration system field and the applied foreground of evaporative condensers in comfortable air conditioning were prospected.展开更多
This paper established an on-line monitoring model for fouling resistance of cooling water based on heat transfer theory,which was mainly applied to the fouling resistance test for condenser of chiller in operation,an...This paper established an on-line monitoring model for fouling resistance of cooling water based on heat transfer theory,which was mainly applied to the fouling resistance test for condenser of chiller in operation,and the test requirements were presented.It proves that the load ratio of chiller has big influence on the test result,and the best load ratio for test is the range of 80%~100%.A case has been executed to validate the model's feasibility.展开更多
文摘Prevailing ambient wind is the main reason thatcauses inlet flow rate(air mass flow rate)decreasingand air flowing backward to the air-cooled condenserfans upward to the wind,hence a set of wind guidingnets is designed to improve the detrimental effect.Fig.1 shows four typical units of a 1000MW directair-cooled condenser(DACC)and a set of windguiding nets installed under its edge upward to theambient wind.As shown in Fig.2,the fan inlet flowrate decreases as the prevailing ambient wind velocityincreasing,especially for the first two units upward tothe wind.
基金Project(217/s/458)supported by Azarbaijan Shahid Madani University,Iran
文摘A statistical signal processing technique was proposed and verified as independent component analysis(ICA) for fault detection and diagnosis of industrial systems without exact and detailed model.Actually,the aim is to utilize system as a black box.The system studied is condenser system of one of MAPNA's power plants.At first,principal component analysis(PCA) approach was applied to reduce the dimensionality of the real acquired data set and to identify the essential and useful ones.Then,the fault sources were diagnosed by ICA technique.The results show that ICA approach is valid and effective for faults detection and diagnosis even in noisy states,and it can distinguish main factors of abnormality among many diverse parts of a power plant's condenser system.This selectivity problem is left unsolved in many plants,because the main factors often become unnoticed by fault expansion through other parts of the plants.
基金Supported by the combined project of the Science and Technology Ministry of Guangdong province and the Science and Tech-nology Ministry of Guangzhou city(2007A04020004,2007C13G0161)
文摘The operating theory of an evaporative condenser was expatiated.The difference between an evaporative condensing refrigeration system and a general refrigeration system was analyzed.Compared with the air-cooled and the water-cooled,the virtues of energy-conservation and water-conservation of evaporative condensers were analyzed.Some questions existing in the application of evaporative condensers were pointed out,the corresponding solving methods were analyzed accordingly,and the development trend of evaporative condensing technique in mechanical refrigeration system field and the applied foreground of evaporative condensers in comfortable air conditioning were prospected.
基金Supported by National Key Technologies R&D Program(2006BAJ02A10)
文摘This paper established an on-line monitoring model for fouling resistance of cooling water based on heat transfer theory,which was mainly applied to the fouling resistance test for condenser of chiller in operation,and the test requirements were presented.It proves that the load ratio of chiller has big influence on the test result,and the best load ratio for test is the range of 80%~100%.A case has been executed to validate the model's feasibility.