Effect of aeration on fast gas pressure tests 被引量:1
1
作者 CHEN Yu-jia JIANG Cheng-lin LI Xiao-wei TANG Jun WANG Chen YANG Fei-long WANG Fa-kai ZHANG Chao-jie DENG Shu-hua 《Mining Science and Technology》 EI CAS 2009年第6期756-760,共5页
Given the problem of the long time required for testing gas pressure, we propose a fast-test method in which we used a technique of fast borehole sealing and air replenishing. Based on the characteristics of gas emiss... Given the problem of the long time required for testing gas pressure, we propose a fast-test method in which we used a technique of fast borehole sealing and air replenishing. Based on the characteristics of gas emission from boreholes to be tested, we built a theoretical model for calculating parameters during the process of increasing natural pressure and aeration. Using this model, we investigated the effect of different aeration conditions on velocity of pressure tests. The result shows that: 1) aerating air into boreholes can speed up gas pressure tests and 2) the more similar the pressure of the aerated air to the original gas pressure, the smaller the gas volume absorbed by coal and the shorter the time needed in pressure test. A case study in the Lu’an mining area shows that the time needed for gas pressure test is only 4 h using our method of aeration and 29 h under conditions of increasing natural pressure, saving time by 86.2%. This case study also indicates that, by using the aeration method, only one hour is needed for gas pressure to reach a stable state, which breaks the record of the shortest time needed for gas pressure tests in China. 展开更多
关键词 aeration gas pressure fast test aeration pressure adsorption quantity
在线阅读 下载PDF
Insight into the structural evolution of porous and fractured media by forced aeration during heap leaching 被引量:5
2
作者 Yu Shaofeng Wu Aixiang Wang Yiming 《International Journal of Mining Science and Technology》 SCIE EI CSCD 2019年第5期803-807,共5页
Despite lots of techniques in improving the heap leaching performance,many constraints on the industrial applications remain.We proposed a correspondingly effective and new idea of introducing forced aeration to impro... Despite lots of techniques in improving the heap leaching performance,many constraints on the industrial applications remain.We proposed a correspondingly effective and new idea of introducing forced aeration to improve the bad permeability and leaching effect of Yangla Copper Mine(YCM)during heap leaching.The dual-media theory was employed to study the impact mechanism of forced aeration on the variations of porous and fractured media during the column leaching experiments.An X-Ray Computed Tomography(CT)set was utilized to perform the pore imaging of the specimens and the fracture morphology of the particles within the columns was analyzed by Scanning Electron Microscope(SEM)as aeration rate(AR)changed.The results show that there exists copious fine particles within the heap of YCM,the particle size distribution of which is not reasonable.The forced aeration can not only promote the development of the porous and fractured structures but effectively break the blocked seepage paths.Then the leaching degree is improved and the seepage performance of the solute within the solution is enhanced.Therefore,the forced aeration is probable of making the leaching performance greatly improved. 展开更多
关键词 LEACHING performance FORCED aeration POROUS and fractured MEDIA CT SEM aeration rate
在线阅读 下载PDF
Field load testing of copper extraction aeration pipes under simulated high heap pile
3
作者 Shad M.Sargand Teruhisa Masada Jim Goddard 《International Journal of Mining Science and Technology》 SCIE EI 2013年第5期751-756,共6页
Recently a research team at Ohio University,USA,conducted a unique full-scale feld load test to simulate the aeration pipe installations at a copper extraction mine operated in Chile.The overliner material taken from ... Recently a research team at Ohio University,USA,conducted a unique full-scale feld load test to simulate the aeration pipe installations at a copper extraction mine operated in Chile.The overliner material taken from the mine was used in recreating the in situ conditions.Electric heaters were utilized to raise the temperature inside each pipe to simulate the essential element of the copper extraction process.The maximum vertical deflection reached by the test pipes was close to 20%,when the simulated heap pile height was 80 m.The plastic pipes and the overliner material were also tested in the laboratory.Based on the results,the maximum heap pile fll depth was recommended for the aeration system.The results indicated that the vertical deflection was the primary performance index for the aeration pipes installed in heap piles at mines.Lastly,the pipe made of polypropylene resin was super. 展开更多
关键词 Copper extraction aeration pipe Heap pile Field load test Laboratory testing
在线阅读 下载PDF
Petroleum Pollution of Groundwater in Zibo and Its Prevention Measures 被引量:1
4
作者 徐建芳 武强 李铎 《Journal of China University of Mining and Technology》 2003年第1期24-28,共5页
The source of ground water supply in Dawu is an extremely huge one in Shandong province. Now it is faced with serious pollution of petroleum in Hougao area. Aiming at this problem, the petroleum pollution in aeration ... The source of ground water supply in Dawu is an extremely huge one in Shandong province. Now it is faced with serious pollution of petroleum in Hougao area. Aiming at this problem, the petroleum pollution in aeration zone and in groundwater was analyzed. The result shows that the contaminant of groundwater comes from the leaching of petroleum in the soil horizon of aeration zone through precipitation, and the quick flow of groundwater makes the convection dominate themigration of contaminant. So movement of groundwater controls the distribution of petroleum contaminant, which is consistent with the direction of ground flow. Building a groundwater closure zone in Hougao is an effective method to stop the contaminated groundwater flowing toward the water supply source of Dawu. The petroleum contaminant can be effectively reduced through using the aeration, biological and oxidation technologies. 展开更多
关键词 Groundwater source Dawu area Petroleum pollution Groundwater closure zone aeration biological and oxidation technology
在线阅读 下载PDF
Polyurea coating for foamed concrete panel:An efficient way to resist explosion 被引量:14
5
作者 Yi-shun Chen Bo Wang +4 位作者 Bei Zhang Qing Zheng Jian-nan Zhou Feng-nian Jin Hua-lin Fan 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2020年第1期136-149,共14页
Autoclaved aerated concrete(AAC) panels have ultra-light weight,excellent thermal insulation and energy absorption,so it is an ideal building material for protective structures.To improve the blast resistance of the A... Autoclaved aerated concrete(AAC) panels have ultra-light weight,excellent thermal insulation and energy absorption,so it is an ideal building material for protective structures.To improve the blast resistance of the AAC panels,three schemes are applied to strengthen the AAC panels through spraying 4 mm thick polyurea coating from top,bottom and double-sides.In three-point bending tests,the polyurea-coated AAC panels have much higher ultimate loads than the un-coated panels,but slightly lower than those strengthened by the carbon fiber reinforced plastics(CEFRPs).Close-in explosion experiments reveal the dynamic strengthening effect of the polyurea coating.Critical scaled distances of the strengthened AAC panels are acquired,which are valuable for the engineering application of the AAC panels in the extreme loading conditions.Polyurea coatings efficiently enhance the blast resistance of the bottom and double-sided polyurea-coated AAC panels.It is interesting that the polyurea-coated AAC panels have much more excellent blast resistance than the CFRP reinforced AAC panels,although the latter have better static mechanical properties. 展开更多
关键词 Autoclaved aerated CONCRETE POLYUREA Explosion FAILURE
在线阅读 下载PDF
Treatment performance of integrated biological aerated filter by orthogonal experiments 被引量:1
6
作者 段秀举 刘亚丽 《Journal of Chongqing University》 CAS 2011年第4期153-158,共6页
Biological aerated filters have many advantages such as small volume and high treatment efficiency. This research focused on sewage treatment performance of integrated biological aerated filter (IBAF) under different ... Biological aerated filters have many advantages such as small volume and high treatment efficiency. This research focused on sewage treatment performance of integrated biological aerated filter (IBAF) under different conditions such as aeration, hydraulic retention time and the height of fillers layer, to identify the turn of marked affecting factor of removal performance through orthogonal experiments, optimize the function parameter of IBAF, reveal the regularity of sewage treatment of IBAF under different conditions, and adopt suitable measures to guarantee excess water quality of IBAF. 展开更多
关键词 integrated biological aerated filter sewage treatment removal efficiency orthogonal experiment
在线阅读 下载PDF
Performance of simultaneous nitrification and denitrification in lateral flow biological aerated filter 被引量:1
7
作者 龙腾锐 《Journal of Chongqing University》 CAS 2006年第4期223-228,共6页
A new wastewater treatment facility—lateral flow biological aerated filter (LBAF) was developed aiming at solving energy consumption and operational problems in wastewater treatment facilities in small towns. It has ... A new wastewater treatment facility—lateral flow biological aerated filter (LBAF) was developed aiming at solving energy consumption and operational problems in wastewater treatment facilities in small towns. It has the function of nitrification and removing organic substrate. In this study, we focused on the denitrification performance of LBAF and its possible mechanism under thorough aeration. We identified the existence of simultaneous nitrification and denitrification (SND) by analyzing nitrogenous compounds along the flow path of LBAF and supportive microbial microscopy, and studied the effects of air/water ratio and hydraulic loading on the performance of nitrogen removal and on SND in LBAF to find out the optimal operation condition. It is found that for saving operation cost, aeration can be reduced to some degree that allows desirable removal efficiency of pollutants, and the optimal air/water ratio is 10:1. Hydraulic loading less than 0.43 m h?1 hardly affects the nitrification and denitrification performance; whereas higher hydraulic loading is unfavorable to both nitrification and denitrification, far more unfavorable to denitrification than to nitrification. 展开更多
关键词 lateral flow biological aerated filter simultaneous nitrification and denitrification air/water ratio hydraulic loading
在线阅读 下载PDF
Enhanced Nutrient Removal with Upflow Biological Aerated Filter for Reclaimed Water
8
作者 王海东 彭永臻 +1 位作者 王淑莹 张艳萍 《Journal of Beijing Institute of Technology》 EI CAS 2007年第3期369-374,共6页
A two-stage upflow biological aerated filter was designed as an advanced treatment process to optimize the operating parameters and study the correlative factors influencing the efficiency of nitrification, denitrific... A two-stage upflow biological aerated filter was designed as an advanced treatment process to optimize the operating parameters and study the correlative factors influencing the efficiency of nitrification, denitrification and phosphorus removal. The experimental results showed that the final effluent of the two-stage upflow biofilter process operated in series could meet the stringent limits of the reclaimed water for the total nitrogen of 2 mg/L, and total phosphorus of 0.3 mg/L. The high treatment efficiency allowed the reactor operating at very high hydraulic loadings and reaching nearly complete nitrification and denitrifieation. 展开更多
关键词 biological aerated filter NITRIFICATION DENITRIFICATION nitrogen and phosphorus removal reclaimed water
在线阅读 下载PDF
Characteristics of integrated biological aerated filter in municipal wastewater treatment
9
作者 何强 《Journal of Chongqing University》 CAS 2005年第4期208-212,共5页
In this paper, the characteristics of integrated biological aerated filter (IBAF) applied to municipal wastewater treatment were studied in a pilot scale experiment. The experimental results showed that IBAF has high ... In this paper, the characteristics of integrated biological aerated filter (IBAF) applied to municipal wastewater treatment were studied in a pilot scale experiment. The experimental results showed that IBAF has high efficiencies in removing organic pollutants, such as CODCr and SS, in municipal wastewater. The removal rates of CODCr and SS can reach over 90% and 80%, respectively, when COD and SS in the influent are 234 mg L1 and 112 mg L1, hydraulic retention time (HRT) is 8 h, and the aerated intensity is in the range of (0.5 to 0.6) L m2 s1. 展开更多
关键词 Integrated biological aerated filter (IBAF) municipal wastewater organic pollutants bio-film
在线阅读 下载PDF
Performances of lateral flow biological aerated filter in treating domestic wastewater
10
作者 张红晶 《Journal of Chongqing University》 CAS 2006年第3期152-156,共5页
A new biological aerated filter?lateral flow biological aerated filter(LBAF) is developed. The effects of air/water ratio, hydraulic loading and the length of LBAF on pollutants removal efficiency are tested. The resu... A new biological aerated filter?lateral flow biological aerated filter(LBAF) is developed. The effects of air/water ratio, hydraulic loading and the length of LBAF on pollutants removal efficiency are tested. The results show that under optimal technological conditions when hydraulic loading is 0.43 m3 m?2 h?1 and air/water ratio is 10:1, the average removal efficiencies of COD, SS, NH3-N, and TN reach 88.01%, 95.18%, 78.97% and 52.58%, respectively. An LBAF has a large pollutants handling capacity; is less liable to be blocked, and has a longer operation cycle in comparison with a traditional BAF. 展开更多
关键词 lateral flow biological aerated filter domestic wastewater ZEOLITE