In order to mitigate the effect of the strong electromagnetic pulse, which produces laser-plasma interactions, we designed a new streaked X-ray spectrometer (SXS) enclosed within a well-sealed, electromag- netic int...In order to mitigate the effect of the strong electromagnetic pulse, which produces laser-plasma interactions, we designed a new streaked X-ray spectrometer (SXS) enclosed within a well-sealed, electromag- netic interference-free cavity. The SXS can cover a wide selection of spectral windows using interchangeable Bragg crystals and by appropriate adjustment of the Bragg angle. The SXS has been used to observe time-re- solved X-ray spectrum in the 2.5 keV to 3.5 keV photon-energy range, resulting in a demonstrated spectral res- olution of about 13 at 2960 eV with a time resolution of 10 ps. The observed time and spectral resolutions dem- onstrate the applicability of the SXS for studies of laser-produced plasmas.展开更多
Spectra of KX-rays emitted from pure 3 dtransition metals and their oxide and sulfate compounds were measured using a single crystal wavelength dispersive X-ray spectroscopy(WDXRF).The measurements were performed usin...Spectra of KX-rays emitted from pure 3 dtransition metals and their oxide and sulfate compounds were measured using a single crystal wavelength dispersive X-ray spectroscopy(WDXRF).The measurements were performed using a ZSX-100 esequential spectrometer equipped with an RhX-ray tube operated.An accurate analytical representation of each line was obtained by a fit to a Lorentz function.The spectra were analyzed in order to examine the KX-ray peak parameters such as asymmetry index,peak energy and relative intensity ratios.The energy shifts and relative intensities weredetermined tobetter understand the chemical effect.展开更多
In this paper,the synthesis of a novel polyoxovanadiumborate[Li(H2O)3]3[V12B18O48(OH)12(OH)]·(H2O)5by hydrothermal method.FTIR,2DFTIR and UV-Vis absorption spectroscopy were employed to explore the relationships ...In this paper,the synthesis of a novel polyoxovanadiumborate[Li(H2O)3]3[V12B18O48(OH)12(OH)]·(H2O)5by hydrothermal method.FTIR,2DFTIR and UV-Vis absorption spectroscopy were employed to explore the relationships between structure and properties of 3-D compound 1.展开更多
A recently released XMM-Newton note revealed a significant calibration issue between nuclear spectroscopic telescope array(NuSTAR)and XMM-Newton European Photon Imaging Camera(EPIC)and provided an empirical correction...A recently released XMM-Newton note revealed a significant calibration issue between nuclear spectroscopic telescope array(NuSTAR)and XMM-Newton European Photon Imaging Camera(EPIC)and provided an empirical correction to the EPIC effective area.To quantify the bias caused by the calibration issue in the joint analysis of XMM-NuSTAR spectra and verify the effectiveness of the correction,in this work,we perform joint-fitting of the NuSTAR and EPIC-pn spectra for a large sample of 104 observation pairs of 44 X-ray bright active galactic nuclei(AGN).The spectra were extracted after requiring perfect simultaneity between the XMM-Newton and NuSTAR exposures(merging good time intervals(GTIs)from two missions)to avoid bias due to the rapid spectral variability of the AGN.Before the correction,the EPIC-pn spectra are systematically harder than the corresponding NuSTAR spectra by■subsequently yielding significantly underestimated cutoff energy E_(cut)and the strength of reflection component R when performing joint-fitting.We confirm that the correction is highly effective and can commendably erase the discrepancy in best-fitΓ,E_(cut),and R.We thus urge the community to apply the correction when joint-fitting XMM-NuSTAR spectra,but note that the correction is limited to 3–12 keV and therefore not applicable when the soft X-ray band data are included.Besides,we show that as merging GTIs from two missions would cause severe loss of NuSTAR net exposure time,in many cases,joint-fitting yields no advantage compared with utilizing NuSTAR data alone.Finally,We present a technical note on filtering periods of high background flares for XMM-Newton EPIC-pn exposures in the small window(SW)mode.展开更多
文摘In order to mitigate the effect of the strong electromagnetic pulse, which produces laser-plasma interactions, we designed a new streaked X-ray spectrometer (SXS) enclosed within a well-sealed, electromag- netic interference-free cavity. The SXS can cover a wide selection of spectral windows using interchangeable Bragg crystals and by appropriate adjustment of the Bragg angle. The SXS has been used to observe time-re- solved X-ray spectrum in the 2.5 keV to 3.5 keV photon-energy range, resulting in a demonstrated spectral res- olution of about 13 at 2960 eV with a time resolution of 10 ps. The observed time and spectral resolutions dem- onstrate the applicability of the SXS for studies of laser-produced plasmas.
基金the Scientific and Technological Research Council of Turkey (TUBITAK), under the project No. 10GT045
文摘Spectra of KX-rays emitted from pure 3 dtransition metals and their oxide and sulfate compounds were measured using a single crystal wavelength dispersive X-ray spectroscopy(WDXRF).The measurements were performed using a ZSX-100 esequential spectrometer equipped with an RhX-ray tube operated.An accurate analytical representation of each line was obtained by a fit to a Lorentz function.The spectra were analyzed in order to examine the KX-ray peak parameters such as asymmetry index,peak energy and relative intensity ratios.The energy shifts and relative intensities weredetermined tobetter understand the chemical effect.
基金the NNSFC(21473030,1371033)Fujian Provincial Natural Science Foundation(2013J01042)the Open Fund of State Key Laboratory of Structural Chemistry(20130015)
文摘In this paper,the synthesis of a novel polyoxovanadiumborate[Li(H2O)3]3[V12B18O48(OH)12(OH)]·(H2O)5by hydrothermal method.FTIR,2DFTIR and UV-Vis absorption spectroscopy were employed to explore the relationships between structure and properties of 3-D compound 1.
基金supported by the National Natural Science Foundation of China(12033006,12192221,123B2042).
文摘A recently released XMM-Newton note revealed a significant calibration issue between nuclear spectroscopic telescope array(NuSTAR)and XMM-Newton European Photon Imaging Camera(EPIC)and provided an empirical correction to the EPIC effective area.To quantify the bias caused by the calibration issue in the joint analysis of XMM-NuSTAR spectra and verify the effectiveness of the correction,in this work,we perform joint-fitting of the NuSTAR and EPIC-pn spectra for a large sample of 104 observation pairs of 44 X-ray bright active galactic nuclei(AGN).The spectra were extracted after requiring perfect simultaneity between the XMM-Newton and NuSTAR exposures(merging good time intervals(GTIs)from two missions)to avoid bias due to the rapid spectral variability of the AGN.Before the correction,the EPIC-pn spectra are systematically harder than the corresponding NuSTAR spectra by■subsequently yielding significantly underestimated cutoff energy E_(cut)and the strength of reflection component R when performing joint-fitting.We confirm that the correction is highly effective and can commendably erase the discrepancy in best-fitΓ,E_(cut),and R.We thus urge the community to apply the correction when joint-fitting XMM-NuSTAR spectra,but note that the correction is limited to 3–12 keV and therefore not applicable when the soft X-ray band data are included.Besides,we show that as merging GTIs from two missions would cause severe loss of NuSTAR net exposure time,in many cases,joint-fitting yields no advantage compared with utilizing NuSTAR data alone.Finally,We present a technical note on filtering periods of high background flares for XMM-Newton EPIC-pn exposures in the small window(SW)mode.