期刊文献+
共找到350篇文章
< 1 2 18 >
每页显示 20 50 100
Simultaneous fluorescence and Compton scattering computed tomography based on linear polarization X-ray
1
作者 Zhi-Jun Chi Hong-Ze Zhang +7 位作者 Jin Lin Xuan-Qi Zhang Hao Ding Qi-Li Tian Zhi Zhang Ying-Chao Du Wen-Hui Huang Chuan-Xiang Tang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第10期41-50,共10页
Purpose To propose a method for simultaneous fluorescence and Compton scattering computed tomography by using linearly polarized X-rays.Methods Monte Carlo simulations were adopted to demonstrate the feasibility of th... Purpose To propose a method for simultaneous fluorescence and Compton scattering computed tomography by using linearly polarized X-rays.Methods Monte Carlo simulations were adopted to demonstrate the feasibility of the proposed method.In the simulations,the phantom is a polytetrafluoroethylene cylinder inside which are cylindrical columns containing aluminum,water,and gold(Au)-loaded water solutions with Au concentrations ranging between 0.5 and 4.0 wt%,and a parallel-hole collimator imaging geometry was adopted.The light source was modeled based on a Thomson scattering X-ray source.The phantom images for both imaging modalities were reconstructed using a maximumlikelihood expectation maximization algorithm.Results Both the X-ray fluorescence computed tomography(XFCT)and Compton scattering computed tomography(CSCT)images of the phantom were accurately reconstructed.A similar attenuation contrast problem for the different cylindrical columns in the phantom can be resolved in the XFCT and CSCT images.The interplay between XFCT and CSCT was analyzed,and the contrast-to-noise ratio(CNR)of the reconstruction was improved by correcting for the mutual influence between the two imaging modalities.Compared with K-edge subtraction imaging,XFCT exhibits a CNR advantage for the phantom.Conclusion Simultaneous XFCT and CSCT can be realized by using linearly polarized X-rays.The synergy between the two imaging modalities would have an important application in cancer radiation therapy. 展开更多
关键词 x-ray fluorescence computed tomography Compton scattering computed tomography Linear polarization Thomson scattering x-ray source Monte Carlo simulation
在线阅读 下载PDF
In situ compression and X-ray computed tomography of flow battery electrodes 被引量:1
2
作者 Rhodri Jervis Matt D.R.Kok +6 位作者 Tobias P.Neville Quentin Meyer Leon D.Brown Francesco Iacoviello Jeff T.Gostick Dan J.L.Brett Paul R.Shearing 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2018年第5期1353-1361,共9页
Redox flow batteries offer a potential solution to an increase in renewable energy generation on the grid by offering long-term, large-scale storage and regulation of power. However, they are currently un- derutilised... Redox flow batteries offer a potential solution to an increase in renewable energy generation on the grid by offering long-term, large-scale storage and regulation of power. However, they are currently un- derutilised due to cost and performance issues, many of which are linked to the microstructure of the porous carbon electrodes used. Here, for the first time, we offer a detailed study of the in situ effects of compression on a commercially available carbon felt electrode. Visualisation of electrode structure us- ing X-ray computed tomography shows the non-linear way that these materials compress and various metrics are used to elucidate the changes in porosity, pore size distribution and tortuosity factor under compressions from 0%-90%. 展开更多
关键词 Redox flow battery x-ray computed tomography Compression Carbon felt RFB
在线阅读 下载PDF
Hybrid reconstruction algorithm for computed tomography based on diagonal total variation 被引量:1
3
作者 Lu-Zhen Deng Peng He +3 位作者 Shang-Hai Jiang Mian-Yi Chen Biao Wei Peng Feng 《Nuclear Science and Techniques》 SCIE CAS CSCD 2018年第3期172-180,共9页
Inspired by total variation(TV), this paper represents a new iterative algorithm based on diagonal total variation(DTV) to address the computed tomography image reconstruction problem. To improve the quality of a reco... Inspired by total variation(TV), this paper represents a new iterative algorithm based on diagonal total variation(DTV) to address the computed tomography image reconstruction problem. To improve the quality of a reconstructed image, we used DTV to sparsely represent images when iterative convergence of the reconstructed algorithm with TV-constraint had no effect during the reconstruction process. To investigate our proposed algorithm, the numerical and experimental studies were performed, and rootmean-square error(RMSE) and structure similarity(SSIM)were used to evaluate the reconstructed image quality. The results demonstrated that the proposed method could effectively reduce noise, suppress artifacts, and reconstruct highquality image from incomplete projection data. 展开更多
关键词 computed tomography (ct) Sparse-view reconstruction DIAGONAL total variation (DTV) COMPRESSIVE sensing (CS)
在线阅读 下载PDF
Three-dimensional visualization of soil pore structure using computed tomography 被引量:1
4
作者 Qiaoling Han Xibo Zhou +2 位作者 Lei Liu Yandong Zhao Yue Zhao 《Journal of Forestry Research》 SCIE CAS CSCD 2019年第3期1053-1061,共9页
The geometric and spatial characteristics of pore structures determine the permeability and water retention of soils, which have important effects on soil functional diversity and ecological restoration. Until recentl... The geometric and spatial characteristics of pore structures determine the permeability and water retention of soils, which have important effects on soil functional diversity and ecological restoration. Until recently, there have not been tools and methods to visually and quantitatively describe the characteristics of soil pores. To solve this problem, this research reconstructs the geometry and spatial distribution of soil pores by the marching cubes method, texture mapping method and the ray casting method widely used in literature. The objectives were to explore an optimal method for three-dimensional visualization of soil pore structure by comparing the robustness of the three methods on soil CT images with single pore structure and porosity ranging from low (2–5%) to high (12–18%), and to evaluate the reconstruction performance of the three methods with different geometric features. The results demonstrate that there are aliases (jagged edges) and deficiency at the boundaries of the model reconstructed by the marching cubes method and pore volumes are smaller than the ground truth, whereas the results of the texture mapping method lack the details of pore structures. For all the soil images, the ray casting method is preferable since it better preserves the pore characteristics of the ground truth. Furthermore, the ray casting method produced the best soil pore model with higher rendering speed and lower memory consumption. Therefore, the ray casting method provides a more advanced method for visualization of pore structures and provides an optional technique for the study of the transport of moisture and the exchange of air in soil. 展开更多
关键词 Soil PORE STRUctURE x-ray computed tomography Three-dimensional reconstruction PORE VISUALIZATION
在线阅读 下载PDF
Seeing through Materials:X-Ray Imaging Using Computed Tomography 被引量:1
5
作者 Yisheng Miao Chengpeng Xue +2 位作者 Xuelong Wu Zhongyao Li Junsheng Wang 《Journal of Beijing Institute of Technology》 EI CAS 2023年第4期494-516,共23页
X-ray computed tomography(XCT)has recently emerged as a powerful tool for characterizing the evolution of microstructure during phase transformation in three dimensional(3D)such as dendritic solidification of alloys.T... X-ray computed tomography(XCT)has recently emerged as a powerful tool for characterizing the evolution of microstructure during phase transformation in three dimensional(3D)such as dendritic solidification of alloys.This paper briefly reviews the recent advances in the in-situ observation of aluminium alloys,magnesium alloys and nickel-based superalloys during solidification using laboratory XCT and synchrotron X-ray sources.The focus is on the growth kinetics of dendrites,porosity and secondary phases.In addition,in-situ characterization during the loading and corrosion process is also discussed. 展开更多
关键词 x-ray computed tomography(Xct) SYNCHROTRON DENDRITE POROSITY ALLOYS
在线阅读 下载PDF
Impact of random and scattered coincidences from outside of field of view on positron emission tomography/computed tomography imaging with different reconstruction protocols
6
作者 Mahak Osouli Alamdari Pardis Ghafarian +2 位作者 Arman Rahmim Mehrdad Bakhshayesh‑Karam Mohammad Reza Ay 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第12期40-52,共13页
Image quality in positron emission tomography(PET)is affected by random and scattered coincidences and reconstruction protocols.In this study,we investigated the effects of scattered and random coincidences from outsi... Image quality in positron emission tomography(PET)is affected by random and scattered coincidences and reconstruction protocols.In this study,we investigated the effects of scattered and random coincidences from outside the field of view(FOV)on PET image quality for different reconstruction protocols.Imaging was performed on the Discovery 690 PET/CT scanner,using experimental configurations including the NEMA phantom(a body phantom,with six spheres of different sizes)with a signal background ratio of 4:1.The NEMA phantom(phantom I)was scanned separately in a one-bed position.To simulate the effect of random and scatter coincidences from outside the FOV,six cylindrical phantoms with various diameters were added to the NEMA phantom(phantom II).The 18 emission datasets with mean intervals of 15 min were acquired(3 min/scan).The emission data were reconstructed using different techniques.The image quality parameters were evaluated by both phantoms.Variations in the signal-to-noise ratio(SNR)in a 28-mm(10-mm)sphere of phantom II were 37.9%(86.5%)for ordered-subset expectation maximization(OSEM-only),36.8%(81.5%)for point spread function(PSF),32.7%(80.7%)for time of flight(TOF),and 31.5%(77.8%)for OSEM+PSF+TOF,respectively,indicating that OSEM+PSF+TOF reconstruction had the lowest noise levels and lowest coefficient of variation(COV)values.Random and scatter coincidences from outside the FOV induced lower SNR,lower contrast,and higher COV values,indicating image deterioration and significantly impacting smaller sphere sizes.Amongst reconstruction protocols,OSEM+PSF+TOF and OSEM+PSF showed higher contrast values for sphere sizes of 22,28,and 37 mm and higher contrast recovery coefficient values for smaller sphere sizes of 10 and 13 mm. 展开更多
关键词 Positron emission tomography/computed tomography(PET/ct) Random coincidences Scatter coincidences·Time of flight(TOF) Point spread function(PSF) Field of view(FOV) Noise equivalent count rate(NECR) Signal-toNoise ratio(SNR)
在线阅读 下载PDF
人机交互CT影像AI识别定位技术在C1型桡骨远端骨折的初步应用 被引量:1
7
作者 成永忠 尹晓冬 +5 位作者 刘飞 邓新恒 王朝鲁 崔书克 李永耀 闫威 《中国骨伤》 2025年第1期31-40,共10页
目的:探讨人机交互智能软件识别定位Cl型桡骨远端骨折的精准性。方法:回顾性分析2023年9月至2024年3月收治的14例C1型桡骨远端骨折患者的CT数据,其中男3例,女11例,年龄27~82岁,随机编号后,由1名高年资骨科医师在院内影像系统上阅片并测... 目的:探讨人机交互智能软件识别定位Cl型桡骨远端骨折的精准性。方法:回顾性分析2023年9月至2024年3月收治的14例C1型桡骨远端骨折患者的CT数据,其中男3例,女11例,年龄27~82岁,随机编号后,由1名高年资骨科医师在院内影像系统上阅片并测量每例患者的尺偏角、桡骨高度、掌倾角、关节内台阶、关节内间隙等,依据桡骨远端骨折复位标准,分为复位组、非复位组。随后将数据依次导入人机交互智能软件,由1名低年资骨科医师识别分析,并测量出同人工测量同样的指标,依据同样标准分组后发现与人工测量信息一致(均复位组6例、非复位组8例,且组内数据两者一致)。继续在软件中对非复位数据行骨骼分割、骨折识别等处理,并生成包含骨折识别信息的诊断报告8份。最后针对需要复位的6例数据,由高年资医师和低年资医师分别在院内影像系统和软件中识别分析,分别判断出每例数据中需要复位的骨折块,由另2名高年资骨科医师核实两者所识别的骨块一致后,再进行骨块位移信息测量;两者在各自系统中分别测量出每1骨块在X轴(内外)、Z轴(前后)、Y轴(上下)上的位移、旋转角度等信息,同时软件组对数据进行骨折识别,并生成包含所有骨块位移信息、骨折识别信息的诊断报告6份。两者分别将各自数据录入数据表中。结果:依据桡骨远端骨折复位标准,两组均得出6例复位、8例非复位数据,且分组数据一致;经配对样本t检验,人工和软件测量14例数据的尺偏角、桡骨高度、关节内台阶、掌倾角、关节内间隙等比较,差异均无统计学意义(P>0.05);在骨折识别方面,软件识别出10例C型骨折,4例数据识别为B型;6例复位数据,每例数据两种测量方式均分割出2个骨块,每组12个骨块,经判定发现所识别骨块一致,经配对样本t检验发现,人工和软件测量骨块X、Y、Z轴位移、旋转角度等比较,差异均无统计学意义(P>0.05)。结论:人机交互CT影像AI识别定位软件在测量C1型桡骨远端骨折解剖学参数方面效能与人工测量近似。 展开更多
关键词 桡骨远端骨折 人机交互 计算机断层扫描 AI识别定位
在线阅读 下载PDF
基于Res2Net注意力机制网络智能检测CT肺动脉成像急性肺动脉栓塞
8
作者 李曼 蒋德攀 +5 位作者 王麦林 李艳若 张晗宇 王颖 张岚 黄婷婷 《中国医学影像学杂志》 北大核心 2025年第4期356-361,369,共7页
目的基于Res2Net注意力机制网络实现CT肺动脉成像急性肺动脉栓塞(APE)的智能检测。资料与方法回顾性收集2015年2月—2023年5月河南中医药大学第一附属医院疑似APE行CT肺动脉成像并确诊为APE的患者。按照7∶2∶1将数据随机分为训练集、... 目的基于Res2Net注意力机制网络实现CT肺动脉成像急性肺动脉栓塞(APE)的智能检测。资料与方法回顾性收集2015年2月—2023年5月河南中医药大学第一附属医院疑似APE行CT肺动脉成像并确诊为APE的患者。按照7∶2∶1将数据随机分为训练集、验证集和测试集。基于Res2Net网络框架,结合多孔空间金字塔池化和注意力机制模块训练模型,对模型进行五折交叉内部验证;在测试集上采用受试者工作特征曲线下面积、敏感度、特异度评估模型的诊断效能;同时采用戴斯相似系数、精确率、交集比并集(IOU)评估模型的分割效能并绘制相应曲线。比较该模型与经典的U-Net模型及CE-Net模型的效能。结果最终纳入303例APE患者,训练集212例,验证集61例,测试集30例。模型的曲线下面积为0.95,敏感度为0.90,特异度为1.00;戴斯相似系数为0.86,精确率为0.90,Pos-IOU为0.78,Neg-IOU为1.00。参数曲线图及雷达图显示Res2Net注意力机制网络多项参数均优于U-Net及CE-Net模型。分割对比的可视化结果显示Res2Net注意力机制网络对肺动脉栓子的分割精准度更高。结论Res2Net注意力机制网络模型对APE具有良好的检测性能。 展开更多
关键词 肺栓塞 ct肺动脉成像 体层摄影术 螺旋计算机 深度学习 Res2Net 注意力机制
在线阅读 下载PDF
Ultrasonic Computed Tomography Imaging Method of Concrete Materials Based on Simulated Annealing Genetic Algorithm 被引量:4
9
作者 李秋锋 王禹 +2 位作者 刘荣梅 顾伟 敖峰 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI CSCD 2015年第3期341-347,共7页
Stability and accuracy of the imaging results are still unmet practical demands for ultrasonic computed tomography(CT)of concrete material.To address these issues,a CT technique based on simulated annealing genetic al... Stability and accuracy of the imaging results are still unmet practical demands for ultrasonic computed tomography(CT)of concrete material.To address these issues,a CT technique based on simulated annealing genetic algorithm(SAGA)is presented in this work.Firstly,a natural weight matrix with clear physical meaning is introduced in the inverse algorithm and then a quadric broadening objective function is formed according to the propagation characteristics of ultrasound in concrete.After that,the simulated annealing(SA)searching is added to speed up the inverse process and to improve the convergence and stability of the algorithm.Finally,the optimal inverse imaging results have been achieved by variable ectopic adaptive genetic algorithm.The numerical simulation experiments have shown that the usage of the correct priori information and the excellent characteristic of SAGA in searching the global minimum value of the function have produced accurate and effective results with stable numerical values.The imaging resolution is improved and the imagining results reflecting the inner defections of the tested objects are more reliable and accurate. 展开更多
关键词 CONCRETE materials computed tomography(ct)imaging
在线阅读 下载PDF
NON-INVASIVE IMAGING OF CORONARY ARTERY WITH 16-SLICE SPIRAL COMPUTED TOMOGRAPHY 被引量:6
10
作者 Zhu-huaZhang Zheng-yuJin +14 位作者 Dong-jingLi Song-baiLin Shu-yangZhang Ling-yanKong YunWang Lin-huiWang Wen-minZhao Wen-binMou Li-RenZhang Wen-lingZhu ChaoNi HuaRen Hong-quanYu QiMiao QiFang 《Chinese Medical Sciences Journal》 CAS CSCD 2004年第3期174-179,共6页
To evaluate the value of 16-slice spiral CT in the demonstration of coronary artery and in the diagnose of coronary artery stenosis. Methods Plain and enhanced CT scans were performed with a 16-slice CT scanner (Sensa... To evaluate the value of 16-slice spiral CT in the demonstration of coronary artery and in the diagnose of coronary artery stenosis. Methods Plain and enhanced CT scans were performed with a 16-slice CT scanner (Sensation 16, Siemens, Germany) in 230 patients with suspected coronary heart disease (CHD). Parameters of the plain scan were: 120 kV, 133 mA, slice col-limation 16 mm×1.5 mm, rotation time 0.42 seconds, increment 1.5 mm, and slice width 3 mm. Parameters of the enhanced scan were: 120 kV, 500 mA, slice collimation 16 mm×0.75 mm, rotation time 0.42 seconds, increment 0.5 mm, and slice width 1 mm. Enhanced CT scan was performed with a rapid intravenous injection of 100 mL iothalamate meglumine (Ultravist) (370 mgI/mL) or Omnipaque (350 mgI/mL) and 30 mL 0.9% NaCl chaser bolus at a flow rate of 3.5 mL/s. Calcium scoring with plain scan images and two and three dimensional reconstruction with enhanced scan images were made in all cases, among which 30 cases underwent conventional coronary angiography. Demonstration of coronary arteries and their stenosis were evaluated and the factors that might influence the image quality were analyzed. Results Coronary calcium scores were calculated and coronary artery was demonstrated in our study. In the evaluationof image quality with volume rendering technique (VRT) images, 78.3% of the images were of the first class, 12.2% the sec-ond class, and 9.6% the third class. Multi-planar reconstruction (MPR) and maximal intensity projection (MIP) were better than VRT in the demonstration of small branches. The image quality was related to the heart rate, with or without arrhythmia, and breath-hold ability of patients. Comparative study of the stenosis of coronary arteries in 30 cases showed that the sensi-tivity and specificity of 16-slice coronary CT angiography (CTA) to diagnose significant stenosis were 95.8% and 94.8% resp-ectively. Conclusion As a non-invasive and quick method, 16-slice coronary CTA is sensitive and specific to diagnose the stenosis of coronary arteries and can be used as a screening method in the diagnosis of CHD. 展开更多
关键词 ANGIOGRAPHY tomography x-ray computed coronary artery
在线阅读 下载PDF
Application of Computed Tomographic Colonography in Diagnosis of Colonic Polyps 被引量:1
11
作者 Ming-wei Qin Wei-dong Pan Guan-ning Cong Yun Wang Yun-qing Zhang Ji-xiang Liang 《Chinese Medical Sciences Journal》 CAS CSCD 2009年第1期36-40,共5页
Objective To assess the clinical values of computed tomographic colonography (CTC) in diagnosis of colonic polyps. Methods Forty-two patients who were clinically suspicious of colonic polyps or underwent colonic po... Objective To assess the clinical values of computed tomographic colonography (CTC) in diagnosis of colonic polyps. Methods Forty-two patients who were clinically suspicious of colonic polyps or underwent colonic polyps screening received examinations with both CTC and conventional colonoscopy. Sixteen- or 64-slice spiral computed tomography and professional imaging processing techniques were used for evaluation. Per-polyp and per-patient results were analyzed. Those by per-polyp were subsequently divided into ≥10 mm group, 5-10 mm group, and ≤5 mm group. Sensitivity, positive predictive value (PPV), specificity, negative predictive value (NPV), and accuracy were calculated using statistical method for diagnostic studies, with conventional colonoscopy as a gold standard. Results Ninety and 61 polyps were found by CTC and conventional colonoscopy, respectively. The per-polyp sensitivity/PPV were 80.3%/55.6% in total, and 100%/92.9%, 93.8%/65.2%, and 68.8%/ 41.5% in the ≥10 mm group, 5-10 mm group, and ≤5 turn group, respectively. The per-patient sensitivity, PPV, specificity, NPV, and accuracy were 97.1%, 89.5%, 42.9%, 75.0%, and 88.1%, respectively. Conclusion CTC can clearly reveal the morphology of colonic polyps and be used as a routine monitoring method for the clinical diagnosis of polyps. 展开更多
关键词 colonic polyp x-ray computed tomography COLONOSCOPY
在线阅读 下载PDF
Transition to computed radiography: can emergency medicine doctors accurately predict the need of film printing to facilitate optimal patient care? 被引量:1
12
作者 Siu Ming Yang Chor Man Lo 《World Journal of Emergency Medicine》 CAS 2011年第1期33-37,共5页
BACKGROUND: This study aimed to evaluate emergency medicine doctors' accuracy in predicting the need of film printing in a simulated setting of computed radiography and assess whether this can facilitate optimal pat... BACKGROUND: This study aimed to evaluate emergency medicine doctors' accuracy in predicting the need of film printing in a simulated setting of computed radiography and assess whether this can facilitate optimal patient care.METHODS: Cross sectional study was conducted from 20 March 2009 to 3 April 2009 in 1334 patients. After clinical assessment of those patients who needed X-ray examination, doctors in the emergency department would indicate whether film printing was necessary for subsequent patient care in a simulated computed radiography setting. The fi nal discharge plan was then retrieved from each patient record. Accuracy of doctors' prediction was calculated by comparing the initial request for radiographic film printing and the final need of film. Doctors with different level of emergency medicine experience would also be analyzed and compared.RESULTS: The sensitivity of predicting fi lm printing was 84.5% and the specifi city of predicting no fi lm printing was 91.2%. Positive predictive value was 88.4% while negative predictive value was 88.2%. The overall accuracy was 88.2%. The accuracy of doctors stratified into groups of fellows, higher trainees and basic trainees were 85.4%, 90.5% and 88.5% respectively (P=0.073).CONCLUSIONS: Our study showed that doctors can reliably predict whether film printing is needed after clinical assessment of patients, before actual image viewing. Advanced indication for film printing at the time of imaging request for selected patients can save time for all parties with minimal wastage. 展开更多
关键词 computed tomography x-ray EMERGENCIES Radiographic image enhancement Forecasting
在线阅读 下载PDF
Investigation of noise properties in grating-based x-ray phase tomography with reverse projection method
13
作者 鲍园 王研 +3 位作者 高昆 王志立 朱佩平 吴自玉 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第10期622-628,共7页
The relationship between noise variance and spatial resolution in grating-based x-ray phase computed tomography(PCT) imaging is investigated with reverse projection extraction method, and the noise variances of the ... The relationship between noise variance and spatial resolution in grating-based x-ray phase computed tomography(PCT) imaging is investigated with reverse projection extraction method, and the noise variances of the reconstructed absorption coefficient and refractive index decrement are compared. For the differential phase contrast method, the noise variance in the differential projection images follows the same inverse-square law with spatial resolution as in conventional absorption-based x-ray imaging projections. However, both theoretical analysis and simulations demonstrate that in PCT the noise variance of the reconstructed refractive index decrement scales with spatial resolution follows an inverse linear relationship at fixed slice thickness, while the noise variance of the reconstructed absorption coefficient conforms with the inverse cubic law. The results indicate that, for the same noise variance level, PCT imaging may enable higher spatial resolution than conventional absorption computed tomography(ACT), while ACT benefits more from degraded spatial resolution. This could be a useful guidance in imaging the inner structure of the sample in higher spatial resolution. 展开更多
关键词 x-ray imaging noise variance spatial resolution computed tomography (ct
在线阅读 下载PDF
Cosine fitting radiography and computed tomography
14
作者 李盼云 张凯 +5 位作者 黄万霞 袁清习 王研 鞠在强 吴自玉 朱佩平 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第6期679-686,共8页
A new method in diffraction-enhanced imaging computed tomography (DEI-CT) that follows the idea developed by Chapman et al. [Chapman D, Thomlinson W, Johnston R E, Washburn D, Pisano E, Gmur N, Zhong Z, Menk R, Arfe... A new method in diffraction-enhanced imaging computed tomography (DEI-CT) that follows the idea developed by Chapman et al. [Chapman D, Thomlinson W, Johnston R E, Washburn D, Pisano E, Gmur N, Zhong Z, Menk R, Arfelli F and Sayers D 1997 Phys. Med. BioL 42 2015] in 1997 is proposed in this paper. Merged with a "reverse projections" algorithm, only two sets of projection datasets at two defined orientations of the analyzer crystal are needed to reconstruct the linear absorption coefficient, the decrement of the real part of the refractive index and the linear scattering coefficient of the sample. Not only does this method reduce the delivered dose to the sample without degrading the image quality, but, compared with the existing DEI-CT approaches, it simplifies data-acquisition procedures. Experimental results confirm the reliability of this new method for DEI-CT applications. 展开更多
关键词 x-ray imaging diffraction-enhanced imaging phase contrast computed tomography
在线阅读 下载PDF
CT值在可评估骨质疏松性胸腰椎骨折经皮椎体成形术术后骨水泥渗漏情况中的价值
15
作者 陈建福 陈逸瑞 +3 位作者 朱振禄 翁就炎 刘鑫 崔运能 《分子影像学杂志》 2025年第3期360-364,共5页
目的 探讨CT值在评估胸腰椎骨质疏松性骨折经皮椎体成形术(PVP)后骨水泥渗漏的价值。方法 回顾性分析2022年3月~2023年12月在佛山汉德骨科医院及佛山三水增康颈腰椎医院有限公司就诊的74例(共计103椎)胸腰椎骨质疏松性骨折PVP术后患者... 目的 探讨CT值在评估胸腰椎骨质疏松性骨折经皮椎体成形术(PVP)后骨水泥渗漏的价值。方法 回顾性分析2022年3月~2023年12月在佛山汉德骨科医院及佛山三水增康颈腰椎医院有限公司就诊的74例(共计103椎)胸腰椎骨质疏松性骨折PVP术后患者临床及影像学资料,其中男23例,女51例,年龄53~94(74.0±9.4)岁,对比发生骨水泥渗漏与非骨水渗漏患者年龄、L1椎体CT值,并评估不同类型骨水泥渗漏阴性及阳性椎体的相邻椎体CT值差异。结果 在74例患者中,55例发生骨水泥渗漏,其年龄更大、L1椎体CT值更低。在所有103椎中,69椎(67.0%)发生骨水泥渗漏,包括椎间盘渗漏17椎(24.6%)、椎旁静脉渗漏38椎(55.1%)、椎旁软组织渗漏15椎(21.8%)、椎基底静脉渗漏14椎(20.3%)、针道渗漏4椎(5.8%)。相比未发生骨水泥渗漏椎体,发生椎间盘渗漏的相邻椎体CT值更低,而其他类型骨水泥渗漏椎体的相邻椎体CT值无显著差别。结论 L1及伤椎相邻椎体CT值与骨质疏松性骨折PVP术后骨水泥渗漏具有相关性,CT值在评估骨水泥渗漏方面具有一定的指导价值。 展开更多
关键词 椎体成形术 骨水泥渗漏 体层摄影术 X线计算机 ct
在线阅读 下载PDF
Framework for COVID-19 Segmentation and Classification Based on Deep Learning of Computed Tomography Lung Images
16
作者 Wessam M.Salama Moustafa H.Aly 《Journal of Electronic Science and Technology》 CAS CSCD 2022年第3期246-256,共11页
Corona Virus Disease 2019(COVID-19) has affected millions of people worldwide and caused more than6.3 million deaths(World Health Organization, June 2022). Increased attempts have been made to develop deep learning me... Corona Virus Disease 2019(COVID-19) has affected millions of people worldwide and caused more than6.3 million deaths(World Health Organization, June 2022). Increased attempts have been made to develop deep learning methods to diagnose COVID-19 based on computed tomography(CT) lung images. It is a challenge to reproduce and obtain the CT lung data, because it is not publicly available. This paper introduces a new generalized framework to segment and classify CT images and determine whether a patient is tested positive or negative for COVID-19 based on lung CT images. In this work, many different strategies are explored for the classification task.ResNet50 and VGG16 models are applied to classify CT lung images into COVID-19 positive or negative. Also,VGG16 and ReNet50 combined with U-Net, which is one of the most used architectures in deep learning for image segmentation, are employed to segment CT lung images before the classifying process to increase system performance. Moreover, the image size dependent normalization technique(ISDNT) and Wiener filter are utilized as the preprocessing techniques to enhance images and noise suppression. Additionally, transfer learning and data augmentation techniques are performed to solve the problem of COVID-19 CT lung images deficiency, therefore the over-fitting of deep models can be avoided. The proposed frameworks, which comprised of end-to-end, VGG16,ResNet50, and U-Net with VGG16 or ResNet50, are applied on the dataset that is sourced from COVID-19 lung CT images in Kaggle. The classification results show that using the preprocessed CT lung images as the input for U-Net hybrid with ResNet50 achieves the best performance. The proposed classification model achieves the 98.98%accuracy(ACC), 98.87% area under the ROC curve(AUC), 98.89% sensitivity(Se), 97.99 % precision(Pr), 97.88%F-score, and 1.8974-seconds computational time. 展开更多
关键词 Augmentation CLASSIFICATION computed tomography(ct) Corona Virus Disease 2019(COVID-19) deep learning ResNet50 SEGMENTATION U-Net VGG16
在线阅读 下载PDF
CT whole lung radiomic nomogram:a potential biomarker for lung function evaluation and identification of COPD
17
作者 Tao-Hu Zhou Xiu-Xiu Zhou +16 位作者 Jiong Ni Yan-Qing Ma Fang-Yi Xu Bing Fan Yu Guan Xin-Ang Jiang Xiao-Qing Lin Jie Li Yi Xia Xiang Wang Yun Wang Wen-Jun Huang Wen-Ting Tu Peng Dong Zhao-Bin Li Shi-Yuan Liu Li Fan 《Military Medical Research》 2025年第1期36-47,共12页
Background:Computed tomography(CT)plays a great role in characterizing and quantifying changes in lung structure and function of chronic obstructive pulmonary disease(COPD).This study aimed to explore the performance ... Background:Computed tomography(CT)plays a great role in characterizing and quantifying changes in lung structure and function of chronic obstructive pulmonary disease(COPD).This study aimed to explore the performance of CT-based whole lung radiomic in discriminating COPD patients and non-COPD patients.Methods:This retrospective study was performed on 2785 patients who underwent pulmonary function examination in 5 hospitals and were divided into non-COPD group and COPD group.The radiomic features of the whole lung volume were extracted.Least absolute shrinkage and selection operator(LASSO)logistic regression was applied for feature selection and radiomic signature construction.A radiomic nomogram was established by combining the radiomic score and clinical factors.Receiver operating characteristic(ROC)curve analysis and decision curve analysis(DCA)were used to evaluate the predictive performance of the radiomic nomogram in the training,internal validation,and independent external validation cohorts.Results:Eighteen radiomic features were collected from the whole lung volume to construct a radiomic model.The area under the curve(AUC)of the radiomic model in the training,internal,and independent external validation cohorts were 0.888[95%confidence interval(CI)0.869–0.906],0.874(95%CI 0.844–0.904),and 0.846(95%CI 0.822–0.870),respectively.All were higher than the clinical model(AUC were 0.732,0.714,and 0.777,respectively,P<0.001).DCA demonstrated that the nomogram constructed by combining radiomic score,age,sex,height,and smoking status was superior to the clinical factor model.Conclusions:The intuitive nomogram constructed by CT-based whole-lung radiomic has shown good performance and high accuracy in identifying COPD in this multicenter study. 展开更多
关键词 Chronic obstructive pulmonary disease(COPD) computed tomography(ct) Radiomic
在线阅读 下载PDF
人工智能诊断系统及CT无创血流储备分数在评估高海拔地区 冠脉临界病变中的应用 被引量:1
18
作者 王雪燕 曹云太 +3 位作者 韩千程 颜梅 韩玲 温生宝 《分子影像学杂志》 2024年第6期616-621,共6页
目的探讨基于冠状动脉CT血管成像(CCTA)的人工智能(AI)诊断系统及CT无创血流储备分数(CT-FFR)在评估高海拔地区冠状动脉临界病变结构及功能学中的应用价值。方法前瞻性收集2022年1月~2023年10月青海大学附属医院冠心病临界病变患者164例... 目的探讨基于冠状动脉CT血管成像(CCTA)的人工智能(AI)诊断系统及CT无创血流储备分数(CT-FFR)在评估高海拔地区冠状动脉临界病变结构及功能学中的应用价值。方法前瞻性收集2022年1月~2023年10月青海大学附属医院冠心病临界病变患者164例,按居住地海拔进行分组,其中2000~3000m为A组(n=83),3000m以上为B组(n=81),再将两组患者按冠脉狭窄程度细分为50%~60%亚组(n=84)和61%~70%亚组(n=80)。将患者冠状动脉CT血管成像数据导入AI辅助诊断及CT-FFR测量系统,以冠脉造影及冠脉传统血流储备分数(FFR)为金标准,分别评价AI及CT-FFR在高海拔地区冠脉临界病变诊断中的应用。结果以FFR为金标准,CT-FFR与FFR的一致性为83.75%。B组钙化斑块、易损斑块高于A组(P=0.037、0.020);B组冠状动脉多支病变、61%~70%狭窄程度发生率均高于A组(P<0.05);A组、B组在61%~70%亚组钙化斑块、易损斑块发生率均高于50%~60%亚组(P<0.05)。B组CT-FFR值低于A组(0.76±0.04 vs 0.88±0.05,P<0.01);A、B两组在61%~70%亚组CT-FFR值≤0.80、<0.70的发生率高于50%~60%亚组(P<0.05)。结论AI诊断系统及CT-FFR对评估高海拔地区冠状动脉临界病变的结构特征及血流动力学改变的结果与冠脉造影、FFR一致性高,具有较高的诊断敏感度和特异度。 展开更多
关键词 人工智能 冠状动脉 ct无创血流储备分数 ct血管成像 冠脉临界病变
在线阅读 下载PDF
基于X-ray CT原位三轴剪切试验的砂土颗粒材料微观动力学 被引量:3
19
作者 苗泽锴 张大任 +4 位作者 马刚 邹宇雄 陈远 周伟 肖宇轩 《浙江大学学报(工学版)》 EI CAS CSCD 北大核心 2023年第8期1597-1606,共10页
将X射线断层扫描技术(CT)与原位三轴剪切试验相结合,分析渥太华砂在剪切过程中的微观动力学演化规律.在试验过程中共完成15次X射线扫描,使用图像分割算法进行颗粒分割并使用球谐函数重构颗粒的表面形貌,根据颗粒的多尺度形态指标序列实... 将X射线断层扫描技术(CT)与原位三轴剪切试验相结合,分析渥太华砂在剪切过程中的微观动力学演化规律.在试验过程中共完成15次X射线扫描,使用图像分割算法进行颗粒分割并使用球谐函数重构颗粒的表面形貌,根据颗粒的多尺度形态指标序列实现整个加载过程中颗粒的准确匹配与追踪,并分析颗粒位移、转动、局部非仿射运动和局部孔隙率等微观动力学和微观结构指标的演化规律.在剪切过程中颗粒体系的竖向位移分布呈现2个锥形区域,颗粒的转动分布出现明显的X型剪切带.用于度量局部塑性变形程度的局部非仿射运动和局部体积分数呈现出较为明显的相关关系,表明颗粒微观动力学与其微观结构之间存在因果关系,局部自由体积较大的地方更易发生塑性变形. 展开更多
关键词 颗粒材料 X射线断层扫描(ct) 三轴试验 微观动力学 微观结构
在线阅读 下载PDF
Penetrating view of nano-structures in Aleochara verna spermatheca and flagellum by hard X-ray microscopy 被引量:2
20
作者 张凯 李德娥 +6 位作者 洪友丽 朱佩平 袁清习 黄万霞 高昆 周红章 吴自玉 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第7期410-414,共5页
A penetrating view of the three-dimensional nanostructure of female spermatheca and male flagellum in the species Aleochara verna is obtained with 100-nm resolution using a hard X-ray microscope, which provides a fast... A penetrating view of the three-dimensional nanostructure of female spermatheca and male flagellum in the species Aleochara verna is obtained with 100-nm resolution using a hard X-ray microscope, which provides a fast noninvasive imaging technology for insect morphology. Through introducing Zernike phase contrast and heavy metal staining, images taken at 8 keV displayed sufficient contrast for observing nanoscale fine structures, such as the spermatheca cochleate duct and the subapex of the flagellum, which have some implications for the study of the sperm transfer process and genital evolution in insects. This work shows that both the spatial resolution and the contrast characteristic of hard X-ray microscopy are quite promising for insect morphology studies and, particularly, provide an attractive alternative to the destructive techniques used for investigating internal soft tissues. 展开更多
关键词 x-ray microscopy computed tomography synchrotron radiation source morphology
在线阅读 下载PDF
上一页 1 2 18 下一页 到第
使用帮助 返回顶部