BACKGROUND:Paraquat (PQ) is a world-wide used herbicide and also a type of common poison for suicide and accidental poisoning. Numerous studies have proved that the concentration of serum PQ plays an important role...BACKGROUND:Paraquat (PQ) is a world-wide used herbicide and also a type of common poison for suicide and accidental poisoning. Numerous studies have proved that the concentration of serum PQ plays an important role in prognosis. Spectrophotometry, including common spectrophotometry and second-derivative spectrophotometry, is commonly used for PQ detection in primary hospitals. So far, lack of systematic research on the reliability of the method and the correlation between clinical features of patients with PQ poisoning and the test results has restricted the clinical use of spectrophotometry. This study aimed to evaluate the reliability and value of spectrophotometry in detecting the concentration of serum PQ. METHODS:The wavelengths for detecting the concentration of serum PQ by common and second-derivative spectrophotometry were determined. Second-derivative spectrophotometry was applied to detect the concentration of serum PQ. The linear range and precision for detection of PQ concentration by this method were confirmed. The concentration of serum PQ shown by second- derivative spectrophotometry and HPLC were compared in 8 patients with PQ poisoning. Altogether 21 patients with acute poisoning 4 hours after PQ ingestion treated in the period of October 2008 to September 2010 were retrospectively reviewed. The patients were divided into higher and lower than 1.8 μg/mL groups based on their concentrations of serum PQ measured by second-derivative spectrophotometry on admission. The severity of clinical manifestations between the two groups were analyzed with Student's t test or Fisher's exact test. RESULTS:The absorption peak of 257 nm could not be found when common spectrophotometry was used to detect the PQ concentration in serum. The calibration curve in the 0.4-8.0 μg/mL range for PQ concentration shown by second-derivative spectrophotometry obeyed Beer's law with r=0.996. The average recovery rates of PQ were within a range of 95.0% to 99.5%, relative standard deviation (RSD) was within 1.35% to 5.41% (n=6), and the lower detection limit was 0.05 μg/mL. The PQ concentrations in serum of 8 patients with PQ poisoning shown by second-derivative spectrophotometry were consistent with the quantitative determinations by HPLC (r=0.995, P〈0.0001). The survival rate was 22.2% in patients whose PQ concentration in serum was more than 1.8 μg/mL, and the incidences of acidosis, oliguria and pneumomediastinum in these patients were 55.6%, 55.6% and 77.8%, respectively. These clinical manifestations were different significantly from those of the patients whose PQ concentration in serum was less than 1.8 pg/mL (P〈0.05). CONCLUSIONS: For common spectrophotometry, the wavelength at 257 nm was not suitable for detecting serum PQ as no absorbance was shown. Second-derivative spectrophotometry was reliable for detecting serum paraquat concentration. Serum PQ concentration detected by second- derivative spectrophotometry could be used to predict the severity of clinical manifestations of patients with PQ poisoning, and PQ content higher than 1.8 tJg/mL 4 hours after ingestion could be an important predictive factor for poor prognosis.展开更多
A simple and sensitive kinetic spectrophotometric method for the determination of trace amounts of titanium(IV),based upon the catalytic effect of Ti(IV) on the oxidation of acid chrome blue K (ACBK) by hydrogen perox...A simple and sensitive kinetic spectrophotometric method for the determination of trace amounts of titanium(IV),based upon the catalytic effect of Ti(IV) on the oxidation of acid chrome blue K (ACBK) by hydrogen peroxide in 0.002 mol/L sulfuric acid,is described. The reaction rate is monitored spectrophotometrically by measuring the decrease in absorbance of ACBK at 524 nm. The detection limit of the method is 1.01×10?9 g/mL,and the linear range is 0-0.048 mg/L. The influence of acidity,concentration of reactants,reaction time,reaction temperature and for-eign ions is also discussed. The optimum reaction conditions were established and some kinetic parameters determined. The apparent activation energy of the catalytic reaction is 5.32 kJ/mol. The relative standard deviation for the determi-nation of titanium(IV) at the concentration of 0.048 mg/L is calculated to be 1.31% (n = 11). In combination with sol-vent extraction separation,the method has been successfully applied to the determination of trace titanium(IV) in human hair,plant matter,tea and rock samples. The results are in good agreement with the certified values with the relative standard deviations (RSD) of 1.4%-3.5%.展开更多
ESR studies were done on UV-ray irradiated silk fabric samples at room temperature. Different types of UV lamps were used and similar ESR signals were observed. The results indicate that UV-rays can produce free radic...ESR studies were done on UV-ray irradiated silk fabric samples at room temperature. Different types of UV lamps were used and similar ESR signals were observed. The results indicate that UV-rays can produce free radicals for graft-copolymerization of monomer onto silk fibers without external additives or co additives, Also, radicals in silk fabrics irradiated by UV-rays are purer than that irradiated by γ-rays. The study suggests that UV-lights may be a better tool to improve properties of silk fabrics by grafting monomers onto the polymer chains.展开更多
DNA analysis is the core of biotechnology applied in petroleum resources and engineering. Traditionally accurate determination of DNA purity and concentration by spectrometer is the first and critical step for downstr...DNA analysis is the core of biotechnology applied in petroleum resources and engineering. Traditionally accurate determination of DNA purity and concentration by spectrometer is the first and critical step for downstream molecular biology research. In this study, three different spectrophotometry methods, BPM, NDTT and NPMTTZ were compared for their performance in determining DNA concentration and purity in 32 oil samples, and molecule methods like quantitative real-time PCR (qPCR) and high-throughput sequence were also performed to help assess the accuracy of the three methods in determining DNA concentration and purity. For ordinary heavy oil (OHO), extra heavy oil (EHO) and super heavy oil (SHO), the characteristics of high viscosity (η), density (ρ) and resin plus asphaltene content will affect the DNA extraction and UV determination. The DNA concentration was decreased as density increased: OHO (11.46 ± 18.34 ng/μL), EHO (6.68 ± 9.67 ng/μL) and SHO (6.20 ± 7.83 ng/μL), and the DNA purity was on the reverse: OHO (1.31 ± 0.27), EHO (1.54 ± 0.20), and SHO (1.83 ± 0.32). The results suggest that spectrophotometry such as BPM and NPMTTZ are qualitatively favorite methods as the quick non-consumable methods in determining DNA concentration and purity of medium oil and heavy oil.展开更多
A spectrophotometric technique is developed to simultaneously quantify nitrate and nitrite in plasma treated water.The measurement is based on examining the inflection points(wavelengths)in the derivative absorbance o...A spectrophotometric technique is developed to simultaneously quantify nitrate and nitrite in plasma treated water.The measurement is based on examining the inflection points(wavelengths)in the derivative absorbance of the nitrate or nitrite solution.At the inflection points of the pure nitrate solution,the derivative absorbance is zero and independent of the nitrate’s concentration,and thus the nitrite’s concentration in a mixed nitrate and nitrite solution can be obtained by using the Beer’s law at these points.The nitrate’s concentration can also be achieved from the inflection points of nitrite in the same manner.The relation between the tested substance’s(nitrate or nitrite)concentration and the second-or the third-order absorbances is obtained at these inflection points.Test measurements for mixed aqueous solutions of nitrate and nitrite with or without hydrogen peroxide confirm the reliability of this technique.We applied this technique to quantify the nitrate and nitrite generated in air plasma treated aqueous solutions.The results indicate that both nitrate and nitrite concentrations increase with the plasma treatment time,and the nitrite species is found to be generated prior to the nitrate species in the air plasma treated aqueous solution.Moreover,the production rate of total nitrogen species is independent of the solutions’p H value.These results are relevant to diverse applications of plasma activated solutions in materials processing,biotechnology,medicine and other fields.展开更多
基金This study was supported by a grant from the National Natural Science Foundation of China(No.30871202).
文摘BACKGROUND:Paraquat (PQ) is a world-wide used herbicide and also a type of common poison for suicide and accidental poisoning. Numerous studies have proved that the concentration of serum PQ plays an important role in prognosis. Spectrophotometry, including common spectrophotometry and second-derivative spectrophotometry, is commonly used for PQ detection in primary hospitals. So far, lack of systematic research on the reliability of the method and the correlation between clinical features of patients with PQ poisoning and the test results has restricted the clinical use of spectrophotometry. This study aimed to evaluate the reliability and value of spectrophotometry in detecting the concentration of serum PQ. METHODS:The wavelengths for detecting the concentration of serum PQ by common and second-derivative spectrophotometry were determined. Second-derivative spectrophotometry was applied to detect the concentration of serum PQ. The linear range and precision for detection of PQ concentration by this method were confirmed. The concentration of serum PQ shown by second- derivative spectrophotometry and HPLC were compared in 8 patients with PQ poisoning. Altogether 21 patients with acute poisoning 4 hours after PQ ingestion treated in the period of October 2008 to September 2010 were retrospectively reviewed. The patients were divided into higher and lower than 1.8 μg/mL groups based on their concentrations of serum PQ measured by second-derivative spectrophotometry on admission. The severity of clinical manifestations between the two groups were analyzed with Student's t test or Fisher's exact test. RESULTS:The absorption peak of 257 nm could not be found when common spectrophotometry was used to detect the PQ concentration in serum. The calibration curve in the 0.4-8.0 μg/mL range for PQ concentration shown by second-derivative spectrophotometry obeyed Beer's law with r=0.996. The average recovery rates of PQ were within a range of 95.0% to 99.5%, relative standard deviation (RSD) was within 1.35% to 5.41% (n=6), and the lower detection limit was 0.05 μg/mL. The PQ concentrations in serum of 8 patients with PQ poisoning shown by second-derivative spectrophotometry were consistent with the quantitative determinations by HPLC (r=0.995, P〈0.0001). The survival rate was 22.2% in patients whose PQ concentration in serum was more than 1.8 μg/mL, and the incidences of acidosis, oliguria and pneumomediastinum in these patients were 55.6%, 55.6% and 77.8%, respectively. These clinical manifestations were different significantly from those of the patients whose PQ concentration in serum was less than 1.8 pg/mL (P〈0.05). CONCLUSIONS: For common spectrophotometry, the wavelength at 257 nm was not suitable for detecting serum PQ as no absorbance was shown. Second-derivative spectrophotometry was reliable for detecting serum paraquat concentration. Serum PQ concentration detected by second- derivative spectrophotometry could be used to predict the severity of clinical manifestations of patients with PQ poisoning, and PQ content higher than 1.8 tJg/mL 4 hours after ingestion could be an important predictive factor for poor prognosis.
基金Project 0520002 supported by the Natural Science Foundation of Jiangxi Province
文摘A simple and sensitive kinetic spectrophotometric method for the determination of trace amounts of titanium(IV),based upon the catalytic effect of Ti(IV) on the oxidation of acid chrome blue K (ACBK) by hydrogen peroxide in 0.002 mol/L sulfuric acid,is described. The reaction rate is monitored spectrophotometrically by measuring the decrease in absorbance of ACBK at 524 nm. The detection limit of the method is 1.01×10?9 g/mL,and the linear range is 0-0.048 mg/L. The influence of acidity,concentration of reactants,reaction time,reaction temperature and for-eign ions is also discussed. The optimum reaction conditions were established and some kinetic parameters determined. The apparent activation energy of the catalytic reaction is 5.32 kJ/mol. The relative standard deviation for the determi-nation of titanium(IV) at the concentration of 0.048 mg/L is calculated to be 1.31% (n = 11). In combination with sol-vent extraction separation,the method has been successfully applied to the determination of trace titanium(IV) in human hair,plant matter,tea and rock samples. The results are in good agreement with the certified values with the relative standard deviations (RSD) of 1.4%-3.5%.
文摘ESR studies were done on UV-ray irradiated silk fabric samples at room temperature. Different types of UV lamps were used and similar ESR signals were observed. The results indicate that UV-rays can produce free radicals for graft-copolymerization of monomer onto silk fibers without external additives or co additives, Also, radicals in silk fabrics irradiated by UV-rays are purer than that irradiated by γ-rays. The study suggests that UV-lights may be a better tool to improve properties of silk fabrics by grafting monomers onto the polymer chains.
基金supported by grants from the PetroChina-CUP Major Strategic Cooperation Projects(ZLZX2020010805,ZLZX2020020405)National Natural Science Foundation of China(41373086)+3 种基金National Science and Technology Major Project(No.2016ZX05050011,2016ZX05040002)Beijing Nova Program and Leading Talent Culturing Cooperative Projects(No.Z161100004916033)Beijing Higher Education Young Elite Teacher Project(No.YETP0670)Outstanding Young Excellent Teachers Foundation of China University of Petroleum(Beijing)(KYJJ2012-01-10).
文摘DNA analysis is the core of biotechnology applied in petroleum resources and engineering. Traditionally accurate determination of DNA purity and concentration by spectrometer is the first and critical step for downstream molecular biology research. In this study, three different spectrophotometry methods, BPM, NDTT and NPMTTZ were compared for their performance in determining DNA concentration and purity in 32 oil samples, and molecule methods like quantitative real-time PCR (qPCR) and high-throughput sequence were also performed to help assess the accuracy of the three methods in determining DNA concentration and purity. For ordinary heavy oil (OHO), extra heavy oil (EHO) and super heavy oil (SHO), the characteristics of high viscosity (η), density (ρ) and resin plus asphaltene content will affect the DNA extraction and UV determination. The DNA concentration was decreased as density increased: OHO (11.46 ± 18.34 ng/μL), EHO (6.68 ± 9.67 ng/μL) and SHO (6.20 ± 7.83 ng/μL), and the DNA purity was on the reverse: OHO (1.31 ± 0.27), EHO (1.54 ± 0.20), and SHO (1.83 ± 0.32). The results suggest that spectrophotometry such as BPM and NPMTTZ are qualitatively favorite methods as the quick non-consumable methods in determining DNA concentration and purity of medium oil and heavy oil.
基金National Natural Science Foundation of China(No.52077185)the Basic Research Program of Science and Technology of Shenzhen,China(No.JCYJ20190809162617137)for partial financial support。
文摘A spectrophotometric technique is developed to simultaneously quantify nitrate and nitrite in plasma treated water.The measurement is based on examining the inflection points(wavelengths)in the derivative absorbance of the nitrate or nitrite solution.At the inflection points of the pure nitrate solution,the derivative absorbance is zero and independent of the nitrate’s concentration,and thus the nitrite’s concentration in a mixed nitrate and nitrite solution can be obtained by using the Beer’s law at these points.The nitrate’s concentration can also be achieved from the inflection points of nitrite in the same manner.The relation between the tested substance’s(nitrate or nitrite)concentration and the second-or the third-order absorbances is obtained at these inflection points.Test measurements for mixed aqueous solutions of nitrate and nitrite with or without hydrogen peroxide confirm the reliability of this technique.We applied this technique to quantify the nitrate and nitrite generated in air plasma treated aqueous solutions.The results indicate that both nitrate and nitrite concentrations increase with the plasma treatment time,and the nitrite species is found to be generated prior to the nitrate species in the air plasma treated aqueous solution.Moreover,the production rate of total nitrogen species is independent of the solutions’p H value.These results are relevant to diverse applications of plasma activated solutions in materials processing,biotechnology,medicine and other fields.