Full waveform inversion(FWI)is a complex data fitting process based on full wavefield modeling,aiming to quantitatively reconstruct unknown model parameters from partial waveform data with high-resolution.However,this...Full waveform inversion(FWI)is a complex data fitting process based on full wavefield modeling,aiming to quantitatively reconstruct unknown model parameters from partial waveform data with high-resolution.However,this process is highly nonlinear and ill-posed,therefore achieving high-resolution imaging of complex biological tissues within a limited number of iterations remains challenging.We propose a multiscale frequency–domain full waveform inversion(FDFWI)framework for ultrasound computed tomography(USCT)imaging of biological tissues,which innovatively incorporates Sobolev space norm regularization for enhancement of prior information.Specifically,we investigate the effect of different types of hyperparameter on the imaging quality,during which the regularization weight is dynamically adapted based on the ratio of the regularization term to the data fidelity term.This strategy reduces reliance on predefined hyperparameters,ensuring robust inversion performance.The inversion results from both numerical and experimental tests(i.e.,numerical breast,thigh,and ex vivo pork-belly tissue)demonstrate the effectiveness of our regularized FWI strategy.These findings will contribute to the application of the FWI technique in quantitative imaging based on USCT and make USCT possible to be another high-resolution imaging method after x-ray computed tomography and magnetic resonance imaging.展开更多
Objective To compare contrast-enhanced magnetic resonance imaging (ceMRI) with nuclear metabolic imaging for the assessment of myocardial viability in patients with chronic ischemic heart disease. Methods Twenty pa...Objective To compare contrast-enhanced magnetic resonance imaging (ceMRI) with nuclear metabolic imaging for the assessment of myocardial viability in patients with chronic ischemic heart disease. Methods Twenty patients with suspected chronic ischemic heart disease underwent ceMRI and technetium-99m sestamibi single-photon emission computed tomography (SPECT). Patients with positive SPECT results also underwent 18 F-fluorodeoxyglucose (FDG) SPECT. In a 17-segment model, the segmental extent of hyperenhancement (SEH) by ceMRI was compared with segmental FDG and sestamibi uptake by SPECT. Correlation between the extent of hyperenhancement by ceMRI and left ventricular function was analyzed. Seven patients got negative results both in ceMRI and technetium-99m sestamibi SPECT. The rest 13 patients with positive results then underwent ^18F-FDG SPECT. In 221 segments of 13 patients, SEH was (2. 1±8.2)%, (25.0±13.7 )%, and (57. 7±23.6 )% in segments with normal metabolism/perfusion, metabolism/perfusion mismatch, and matched defects, respectively, and there were significant differences between either two of them ( all P 〈 0.05). By receiver operating characteristic curve analysis, the area under the curve was 0. 95 for the differentiation between viable and non-viable segments. At the cutoff value of 34%, SEH optimally differentiated viable from non-viable segments defined by SPECT. Using this threshold, the sensitivity and specificity of ceMRI to detect non-viable myocardium as defined by SPECT were 92% and 93%, respectively. Hyperenhancement size by ceMRI was correlated negatively with the left ventricular ejection fraction ( r = - 0.90, P 〈 0.01 ) and positively with left ventricular volumes ( r = 0. 62 for end-diastolic volume, r = 0.75 for end-systolic volume, both P 〈 0.05 ). Conclusion CeMRI allows assessment of myocardial viability with a high accuracy in patients with chronic ischemic heart disease.展开更多
Purpose To propose a method for simultaneous fluorescence and Compton scattering computed tomography by using linearly polarized X-rays.Methods Monte Carlo simulations were adopted to demonstrate the feasibility of th...Purpose To propose a method for simultaneous fluorescence and Compton scattering computed tomography by using linearly polarized X-rays.Methods Monte Carlo simulations were adopted to demonstrate the feasibility of the proposed method.In the simulations,the phantom is a polytetrafluoroethylene cylinder inside which are cylindrical columns containing aluminum,water,and gold(Au)-loaded water solutions with Au concentrations ranging between 0.5 and 4.0 wt%,and a parallel-hole collimator imaging geometry was adopted.The light source was modeled based on a Thomson scattering X-ray source.The phantom images for both imaging modalities were reconstructed using a maximumlikelihood expectation maximization algorithm.Results Both the X-ray fluorescence computed tomography(XFCT)and Compton scattering computed tomography(CSCT)images of the phantom were accurately reconstructed.A similar attenuation contrast problem for the different cylindrical columns in the phantom can be resolved in the XFCT and CSCT images.The interplay between XFCT and CSCT was analyzed,and the contrast-to-noise ratio(CNR)of the reconstruction was improved by correcting for the mutual influence between the two imaging modalities.Compared with K-edge subtraction imaging,XFCT exhibits a CNR advantage for the phantom.Conclusion Simultaneous XFCT and CSCT can be realized by using linearly polarized X-rays.The synergy between the two imaging modalities would have an important application in cancer radiation therapy.展开更多
BACKGROUND:Patients who present to the emergency department(ED)for suspected pulmonary embolism(PE)are often on active oral anticoagulation(AC).However,the diagnostic yield of computed tomography pulmonary angiography...BACKGROUND:Patients who present to the emergency department(ED)for suspected pulmonary embolism(PE)are often on active oral anticoagulation(AC).However,the diagnostic yield of computed tomography pulmonary angiography(CTPA)in screening for PE in patients who present on AC has not been well characterized.We aim to investigate the diagnostic yield of CTPA in diagnosing PE depending on AC status.METHODS:We reviewed and analyzed the electronic medical records of patients who underwent CTPA for PE at a university hospital ED from June 1,2019,to March 25,2022.Primary outcome was the incidence of PE on CTPA depending on baseline AC status and indication for AC.RESULTS:Of 2,846 patients,242 were on AC for a history of venous thromboembolism(VTE),210 were on AC for other indications,and 2,394 were not on AC.The incidence of PE on CTPA was significantly lower in patients on AC for other indications(5.7%)when compared to patients on AC for prior VTE(24.3%)and patients not on AC at presentation(9.8%)(P<0.001).In multivariable analysis among the whole cohort,AC was associated with a positive CTPA(odds ratio[OR]0.26,95%confidence interval[CI]:0.15-0.45,P<0.001).CONCLUSION:The incidence of PE among patients undergoing CTPA in the ED is lower in patients previously on AC for indications other than VTE when compared to those not on AC or those on AC for history of VTE.AC status and indication for AC may affect pre-test probability of a positive CTPA,and AC status therefore warrants consideration as part of future diagnostic algorithms among patients with suspected PE.展开更多
Image quality in positron emission tomography(PET)is affected by random and scattered coincidences and reconstruction protocols.In this study,we investigated the effects of scattered and random coincidences from outsi...Image quality in positron emission tomography(PET)is affected by random and scattered coincidences and reconstruction protocols.In this study,we investigated the effects of scattered and random coincidences from outside the field of view(FOV)on PET image quality for different reconstruction protocols.Imaging was performed on the Discovery 690 PET/CT scanner,using experimental configurations including the NEMA phantom(a body phantom,with six spheres of different sizes)with a signal background ratio of 4:1.The NEMA phantom(phantom I)was scanned separately in a one-bed position.To simulate the effect of random and scatter coincidences from outside the FOV,six cylindrical phantoms with various diameters were added to the NEMA phantom(phantom II).The 18 emission datasets with mean intervals of 15 min were acquired(3 min/scan).The emission data were reconstructed using different techniques.The image quality parameters were evaluated by both phantoms.Variations in the signal-to-noise ratio(SNR)in a 28-mm(10-mm)sphere of phantom II were 37.9%(86.5%)for ordered-subset expectation maximization(OSEM-only),36.8%(81.5%)for point spread function(PSF),32.7%(80.7%)for time of flight(TOF),and 31.5%(77.8%)for OSEM+PSF+TOF,respectively,indicating that OSEM+PSF+TOF reconstruction had the lowest noise levels and lowest coefficient of variation(COV)values.Random and scatter coincidences from outside the FOV induced lower SNR,lower contrast,and higher COV values,indicating image deterioration and significantly impacting smaller sphere sizes.Amongst reconstruction protocols,OSEM+PSF+TOF and OSEM+PSF showed higher contrast values for sphere sizes of 22,28,and 37 mm and higher contrast recovery coefficient values for smaller sphere sizes of 10 and 13 mm.展开更多
Background Elderly patients generally have higher occurrence of coronary calcification, increased heart rate and difficulty with prolonged breath-holding. The aim of our study was to investigate the feasibility and ac...Background Elderly patients generally have higher occurrence of coronary calcification, increased heart rate and difficulty with prolonged breath-holding. The aim of our study was to investigate the feasibility and accuracy of using 64-row multi-detector computed tomography (MDCT) in the assessment of coronary artery stenoses in elderly patients. Methods One hundred and fifty two patients with suspected or known coronary artery disease were divided into 4 groups according to their age (Group A: 40-49 years,n=34; Group B: 50-59 years, n=57; Group C: 60-69 years, n=48; Group D: 70 years and above; n=13). Coronary CT angiography (CTA) using a 64-row MDCT was performed and the findings were compared with that of conventional coronary angiography (CCA).Using axial images, multi-planar reconstructions (MPR) and maximum intensity projections (MIP), coronary segments of lumen diameter = 1.5mm were analyzed for the presence of significant stenosis (= 50% ). Results Percentages of poor image quality from coronary CTA preventing reliable correlations with CCA were 21%, 14%, 19% and 62% in Groups A to D respectively. Patients in Group D had significantly higher calcium scores compared with the other groups (P<0.001). In patients where CTA images were of acceptable quality, percentages of accurate correlations with CCA were 89.8%, 93.4%, 86.6% and 78.0% for Groups A to D respectively.There were no significant difference in serum creatinine, heart rate and contrast volume between the 4 groups. Conclusions The 64-row MDCT coronary angiography was less accurate and feasible for patients aged 70 years or above due to heavy coronary calcification and inability to perform a satisfactory breath-hold. However, a high diagnostic accuracy with the MDCT is possible in patients aged less than 70 years.展开更多
Multislice CT angiography represents one of the most exciting technological revolutions in cardiac imaging and it has been increasingly used in the diagnosis of coronary artery disease. Rapid improvements in multislic...Multislice CT angiography represents one of the most exciting technological revolutions in cardiac imaging and it has been increasingly used in the diagnosis of coronary artery disease. Rapid improvements in multislice CT scanners over the last decade have allowed this technique to become a potentially effective alternative to invasive coronary angiography in patients with suspected coronary artery disease. High diagnostic value has been achieved with multislice CT angiography with use of 64- and more slice CT scanners. In addition, multislice CT angiography shows accurate detection and analysis of coronary calcium, characterization of coronary plaques, as well as prediction of the disease progression and major cardiac events. Thus, patients can benefit from multislice CT angiography that provides a rapid and accurate diagnosis while avoiding unnecessary invasive coronary angiography procedures. The aim of this article is present an overview of the clinical applications of multislice CT angiography in coronary artery disease with a focus on the diagnostic accuracy of coronary artery disease; prognostic value of coronary artery disease with regard to the prediction of major cardiac events; detection and quantification of coronary calcium and characterization of coronary plaques. Limitations of multislice CT angiography in coronary artery disease are also briefly discussed, and future directions are highlighted.展开更多
Objective To investigate the image quality, radiation dose and diagnostic value of the low-tube-voltage high-pitch dual-source computed tomography(DSCT) with sinogram affirmed iterative reconstruction(SAFIRE) for non-...Objective To investigate the image quality, radiation dose and diagnostic value of the low-tube-voltage high-pitch dual-source computed tomography(DSCT) with sinogram affirmed iterative reconstruction(SAFIRE) for non-enhanced abdominal and pelvic scans. Methods This institutional review board-approved prospective study included 64 patients who gave written informed consent for additional abdominal and pelvic scan with DSCT in the period from November to December 2012. The patients underwent standard non-enhanced CT scans(protocol 1) [tube voltage of 120 k Vp/pitch of 0.9/filtered back-projection(FBP) reconstruction] followed by high-pitch non-enhanced CT scans(protocol 2)(100 k Vp/3.0/SAFIRE). The total scan time, mean CT number, signal-to-noise ratio(SNR), image quality, lesion detectability and radiation dose were compared between the two protocols. Results The total scan time of protocol 2 was significantly shorter than that of protocol 1(1.4±0.1 seconds vs. 7.6±0.6 seconds, P<0.001). There was no significant difference between protocol 1 and protocol 2 in mean CT number of all organs(liver, 55.4±6.3 HU vs. 56.1±6.8 HU, P=0.214; pancreas, 43.6±5.9 HU vs. 43.7±5.8 HU, P=0.785; spleen, 47.9±3.9 HU vs. 49.4±4.3 HU, P=0.128; kidney, 32.2±2.3 HU vs. 33.1±2.3 HU, P=0.367; abdominal aorta, 44.8±5.6 HU vs. 45.0±5.5 HU, P=0.499; psoas muscle, 50.7±4.1 HU vs. 50.3±4.5 HU, P=0.279). SNR on images of protocol 2 was higher than that of protocol 1(liver, 5.0±1.2 vs. 4.5±1.1, P<0.001; pancreas, 4.0±1.0 vs. 3.6±0.8, P<0.001; spleen, 4.7±1.0 vs. 4.1±0.9, P<0.001; kidney, 3.1±0.6 vs. 2.8±0.6, P<0.001; abdominal aorta, 4.1±1.0 vs. 3.8±1.0, P<0.001; psoas muscle, 4.5±1.1 vs. 4.3±1.2, P=0.012). The overall image noise of protocol 2 was lower than that of protocol1(9.8±3.1 HU vs. 11.1±3.0 HU, P<0.001). Image quality of protocol 2 was good but lower than that of protocol 1(4.1±0.7 vs. 4.6±0.5, P<0.001). Protocol 2 perceived 229 of 234 lesions(97.9%) that were detected in protocol 1 in the abdomen and pelvis. Radiation dose of protocol 2 was lower than that of protocol 1(4.4±0.4 m Sv vs. 7.3±2.4 m Sv, P<0.001) and the mean dose reduction was 41.4%. Conclusion The high-pitch DSCT with SAFIRE can shorten scan time and reduce radiation dose while preserving image quality in non-enhanced abdominal and pelvic scans.展开更多
Stability and accuracy of the imaging results are still unmet practical demands for ultrasonic computed tomography(CT)of concrete material.To address these issues,a CT technique based on simulated annealing genetic al...Stability and accuracy of the imaging results are still unmet practical demands for ultrasonic computed tomography(CT)of concrete material.To address these issues,a CT technique based on simulated annealing genetic algorithm(SAGA)is presented in this work.Firstly,a natural weight matrix with clear physical meaning is introduced in the inverse algorithm and then a quadric broadening objective function is formed according to the propagation characteristics of ultrasound in concrete.After that,the simulated annealing(SA)searching is added to speed up the inverse process and to improve the convergence and stability of the algorithm.Finally,the optimal inverse imaging results have been achieved by variable ectopic adaptive genetic algorithm.The numerical simulation experiments have shown that the usage of the correct priori information and the excellent characteristic of SAGA in searching the global minimum value of the function have produced accurate and effective results with stable numerical values.The imaging resolution is improved and the imagining results reflecting the inner defections of the tested objects are more reliable and accurate.展开更多
With the development of the compressive sensing theory, the image reconstruction from the projections viewed in limited angles is one of the hot problems in the research of computed tomography technology. This paper d...With the development of the compressive sensing theory, the image reconstruction from the projections viewed in limited angles is one of the hot problems in the research of computed tomography technology. This paper develops an iterative algorithm for image reconstruction, which can fit the most cases. This method gives an image reconstruction flow with the difference image vector, which is based on the concept that the difference image vector between the reconstructed and the reference image is sparse enough. Then the l1-norm minimization method is used to reconstruct the difference vector to recover the image for flat subjects in limited angles. The algorithm has been tested with a thin planar phantom and a real object in limited-view projection data. Moreover, all the studies showed the satisfactory results in accuracy at a rather high reconstruction speed.展开更多
To evaluate the value of 16-slice spiral CT in the demonstration of coronary artery and in the diagnose of coronary artery stenosis. Methods Plain and enhanced CT scans were performed with a 16-slice CT scanner (Sensa...To evaluate the value of 16-slice spiral CT in the demonstration of coronary artery and in the diagnose of coronary artery stenosis. Methods Plain and enhanced CT scans were performed with a 16-slice CT scanner (Sensation 16, Siemens, Germany) in 230 patients with suspected coronary heart disease (CHD). Parameters of the plain scan were: 120 kV, 133 mA, slice col-limation 16 mm×1.5 mm, rotation time 0.42 seconds, increment 1.5 mm, and slice width 3 mm. Parameters of the enhanced scan were: 120 kV, 500 mA, slice collimation 16 mm×0.75 mm, rotation time 0.42 seconds, increment 0.5 mm, and slice width 1 mm. Enhanced CT scan was performed with a rapid intravenous injection of 100 mL iothalamate meglumine (Ultravist) (370 mgI/mL) or Omnipaque (350 mgI/mL) and 30 mL 0.9% NaCl chaser bolus at a flow rate of 3.5 mL/s. Calcium scoring with plain scan images and two and three dimensional reconstruction with enhanced scan images were made in all cases, among which 30 cases underwent conventional coronary angiography. Demonstration of coronary arteries and their stenosis were evaluated and the factors that might influence the image quality were analyzed. Results Coronary calcium scores were calculated and coronary artery was demonstrated in our study. In the evaluationof image quality with volume rendering technique (VRT) images, 78.3% of the images were of the first class, 12.2% the sec-ond class, and 9.6% the third class. Multi-planar reconstruction (MPR) and maximal intensity projection (MIP) were better than VRT in the demonstration of small branches. The image quality was related to the heart rate, with or without arrhythmia, and breath-hold ability of patients. Comparative study of the stenosis of coronary arteries in 30 cases showed that the sensi-tivity and specificity of 16-slice coronary CT angiography (CTA) to diagnose significant stenosis were 95.8% and 94.8% resp-ectively. Conclusion As a non-invasive and quick method, 16-slice coronary CTA is sensitive and specific to diagnose the stenosis of coronary arteries and can be used as a screening method in the diagnosis of CHD.展开更多
Objective To explore the perihematomal perfusion typing and spot sign on computed tomography angiography(CTA) source images in order to assist in individualizing therapeutic decisions for patients with intracerebral h...Objective To explore the perihematomal perfusion typing and spot sign on computed tomography angiography(CTA) source images in order to assist in individualizing therapeutic decisions for patients with intracerebral hemorrhage by possibly forecasting perihematomal ischemia and hematoma enlargement. Methods We examined 58 patients with spontaneous intracerebral hemorrhage by computed tomography perfusion and CTA within 6 hours after symptom onset. Hematoma volumes were determined from non-contrast CT images and compared between first and second CT images. The perfusion of hematoma region and perihematoma region was evaluated for presence or absence of the perihematomal penumbra. Three kinds of perihematoma perfusion typing were defined according to the perfusion of hematoma region and perihematoma region. CTA source images was reviewed to make sure presence or absence of the spot sign. Results Finally, 53 patients(34 males, 19 females) were enrolled in our study according to exclusion criteria. Finally, 21 patients were classified into the normal group, 23 patients were classified into the mild group, and 9 patients were classified into the severe group. There were significant differences in hematoma size between the presence and absence of the perihematomal penumbra group(P<0.05). Thirteen(24.5%) patients presented with spot sign. Hematoma expansion occurred in 15(28.3%) patients on follow-up. In which 12 patients were with spot sign. Sensitivity, specificity, positive predictive value, and negative predictive value for expansion were 80.0%, 97.4%, 92.3%, and 92.5%, respectively. Conclusion In acute intracerebral hemorrhage patients, the perihematoma perfusion typing and CTA spot sign provide more radiological information that might assist in individualizing therapeutic decisions for patients by possibly forecasting perihematomal ischemia and hematoma enlargement.展开更多
Objective To compare 16-slice multi-detector spiral computed tomography (MDCT) and breathhold 3D magnetic resonance (MR) coronary angiography in the visualization of coronary arteries and the accuracy of detecting sig...Objective To compare 16-slice multi-detector spiral computed tomography (MDCT) and breathhold 3D magnetic resonance (MR) coronary angiography in the visualization of coronary arteries and the accuracy of detecting significant (> 50%) coronary stenoses in patients with suspected coronary artery disease. Methods Forty patients were examined by 16-slice CT (GE, Lightspeedl6)and MR (GE,Twinspeed) within 3 days; 31 of them underwent conventional coronary angiography (CAG) within 2 weeks after CT and MR scan. CT was performed with 16× 1.25 mm detector collimation, 0.5 s rotation time and images were reconstructed at 60%-75% of the cardiac cycle. MR was performed with breath hold 3D FIESTA (TR4.0 ms, TE1.7 ms, flip angle 65, slice thickness 3 mm, FOV 280 mm, matrix 256× 192). Mean heart rate was 63 ± 5.8 bpm and β-blocker was used in 24 patients. MR and CT image quality was evaluated in 9 coronary segments (RCA1, RCA2, RCA3, LM, LAD1, LAD2, LAD3, LCX1, LCX2) using a four-point grading scale.Sensitivity, specificity, positive predictive value, negative predictive value and accuracy were calculated for detection of significant stenosis using CAG as the gold standard. Results 16-slice CT showed higher image quality in most coronary segments except RCA2.Forty-three segments were diagnosed as significant stenosis by CAG, 36 and 27 of these were correctly detected by CT and MR respectively. Sensitivity, specificity, positive predictive value, and negative predictive value of 16-slice CT and MR for detecting significant stenosis were 83 %, 84 %, 49 %, 97 % and 63 %, 90 %, 55 %, 93 %, respectively. Conclusion Sixteen-slice CT showed higher image quality in most coronary segments excepted for middle RCA. 16-slice CT had higher sensitivity than MR for detection of coronary significant stenosis, whereas MR had higher specificity than CT. Both CT and MR showed high negative predictive value,which is useful for excluding coronary stenosis in symptomatic patients.展开更多
Objective To assess lumen visibility of coronary stents by 64-slice computed tomography (CT) coronary angiography, and determine the value of 64-slice CT in non-invasive detecting of in-stent restenosis after coro...Objective To assess lumen visibility of coronary stents by 64-slice computed tomography (CT) coronary angiography, and determine the value of 64-slice CT in non-invasive detecting of in-stent restenosis after coronary artery stent implantation. Methods Totally, 60 patients (54 males, aged 57.0±12.7 years) and /05 stents were investigated by 64-slice CT at a mean interval of 20.0±16.6 months after coronary stents implantation. Axial multi-planar reconstruction images of the stents and curved-planar reconstruction images through the median of the stents were reconstructed for evaluating stent image quality on a 5-point scale (1=excellent, 5=nonassessable), and stent lumen diameter was detected. Conventional coronary angiography was performed in 18 patients, and 32 stents were evaluated. Results Image quality was good to excellent on average (score 1.71±0.76). Stent image quality score was correlated to heart rate (r=0. 281, P〈0.01) and stent diameter (r=-0.480, P〈0.001). All the stents were assessable in lumen visibility with an average visible lumen diameter percentage of 60.7%±13.6%. Visible lumen diameter percentage was correlated to heart rate (r=-0.193, P〈0.05), stent diameter (r=0.403, P〈0.001), and stent image quality score (r=-0.500, P〈0.001). Visible lumen diameter percentage also varied depending on the stent type. In comparison with the conventional coronary angiography, 4 of 6 in-stent stenoses were correctly detected. The sensitivity and specificity for the detection of in-stent stenosis were 66.7% and 84.6%, respectively. Conclusions Using a 64-slice CT, the stent lumen is partly visible in most of the stents. And 64-slice CT may be useful in the assessment of stent patency.展开更多
Objective To explore the scan technique and image quality of coronary angiography with dual source computed tomography(CT) without oral metoprolol preparation.Methods Plain and enhanced dual source CT coronary angiogr...Objective To explore the scan technique and image quality of coronary angiography with dual source computed tomography(CT) without oral metoprolol preparation.Methods Plain and enhanced dual source CT coronary angiography without oral metoprolol preparation was prospectively performed in 600 patients.Calcium scoring with plain scan images as well as multi-planar reconstruction(MPR),maximum intensity projection(MIP),and volume rendering technique(VRT) reconstruction with enhanced scan images were performed in all cases.The scan technique and post-reconstruction experience was summarized.The image quality was classified as 1 to 4 points,and coronary segments classified according to the American Heart Association standards were evaluated.Results The average calcium score of the 600 cases was 213.6±298.7(0-3 216.5).The average heart rate of the enhanced scan was 82.1±16.2(47-139) bpm.The post-reconstruction methods with which coronary segments could be shown as best as possible consisted of single phase reconstruction method,two or more phases supplemented method,and electrocardiogram editing method.Altogether 8 457 coronary segments were evaluated,among which 97.2% were evaluated as point 1,1.7% point 2,0.5% point 3,and 0.6% point 4.The coronary segments in 261 cases were completely normal,while 360 segments were diagnosed with <50% stenosis and 625 segments with ≥50% stenosis.Conclusions Excellent coronary artery image can be obtained with dual source CT in patients with any heart rate without oral metoprolol preparation.Heart rate is not a major source of the artifact,coronary segments can be well shown with single or multiple-phase reconstruction method.展开更多
Microstructure of shale formation is the key to understanding its petrophysical and chemical properties.Optical microscopy, scanning electron microscopy and micro-computed tomography(μ-CT) have been combined for char...Microstructure of shale formation is the key to understanding its petrophysical and chemical properties.Optical microscopy, scanning electron microscopy and micro-computed tomography(μ-CT) have been combined for characterization of microstructure of Longmaxi(LMX)shale from Shizhu area, Sichan Basin. The results indicate that laminated LMX shale consists of mineral matrix-rich layers and organic matter(OM)-rich layers at micrometer scale in two and three dimensions. Mineral matrix layers,mainly consisting of interparticle pores and intraplatelet pores, are approximately parallel to the bedding plane.Pyrite-rich layer, mainly containing intercrystalline pores,shows a strong preferred orientation parallel to the bedding plane. OM-rich layer, mainly containing OM pores, seems to be discontinuous. In addition, intercrystalline pores are enriched in some layers, while OM pores are distributed irregularly in matrix layers. This vertical heterogeneity of pore microscopic structures in LMX shale is of great importance to understand its petrophysical and chemical properties.展开更多
BACKGROUND:To assess the association between relevant brain computed tomography(CT)parameters at different time and neurological prognosis in adult comatose survivors after cardiac arrest(CA).METHODS:A total of 94 CA ...BACKGROUND:To assess the association between relevant brain computed tomography(CT)parameters at different time and neurological prognosis in adult comatose survivors after cardiac arrest(CA).METHODS:A total of 94 CA patients who underwent early and late CT scans(within 24 h and 24 h to 7 d respectively after CA)between January 2018 and April 2020 were enrolled in this retrospective study.According to the Cerebral Performance Category(CPC)score at hospital discharge,the patients were divided into either a good outcome(CPC 1-2)group or a poor-outcome group(CPC 3-5).The grey-to-white matter ratio(GWR)and the proportion of cerebrospinal fluid volume(pCSFV)were measured.In predicting poor outcomes,the prognostic performance of relevant CT parameters was evaluated,and the comparison analysis(expressed as the ratio of parameters in late CT to those in the early CT)of diff erent CT time was conducted.RESULTS:Totally 26 patients were in the good-outcome group,while 68 patients were in the poor-outcome group.The putamen density,GWR,and pCSFV in late CT were significantly lower in the poor-outcome group(P<0.05).The ratios of GWR and pCSFV in the poor-outcome group were signifi cantly decreased according to comparison analysis of diff erent CT time(P<0.05),while there was no signifi cant diff erence in the ratio of putamen density.GWR-basal ganglia<1.18 in late CT showed the best predictive value.The ratio of pCSFV<0.98 predicted unfavorable neurological outcomes with a sensitivity of 65.9%and a specifi city of 93.8%(P=0.001).CONCLUSIONS:Brain CT performed>24 h after CA may be a good choice as a neuroimaging approach to evaluating prognosis.To predict neurological prognosis,comparison analysis of diff erent CT time can be used as another promising tool in comatose CA survivors.展开更多
Although the average age of diagnosis for aorticdissection is 63,[1] this case demonstrates the need toconsider AD in younger patients, particularly in thepresence of risk factors or in the absence of anotherreasonabl...Although the average age of diagnosis for aorticdissection is 63,[1] this case demonstrates the need toconsider AD in younger patients, particularly in thepresence of risk factors or in the absence of anotherreasonable diagnosis. This case suggests PCP use as aprecipitant for hypertension and sympathomimetic stresson the aorta. Despite high sensitivity, false negativeCTA imaging for AD can occur. If pretest probabilityremains high, further imaging must be obtained. Duringresuscitation in the ED, focused point-of-care ultrasoundcan also assist with medical decision making.展开更多
Computed tomography has been proven to be useful for non-destructive inspection of structures and materials. We build a three-dimensional imaging system with the photonically generated incoherent noise source and the ...Computed tomography has been proven to be useful for non-destructive inspection of structures and materials. We build a three-dimensional imaging system with the photonically generated incoherent noise source and the Schottky barrier diode detector in the terahertz frequency band (90–140GHz). Based on the computed tomography technique, the three-dimensional image of a ceramic sample is reconstructed successfully by stacking the slices at different heights. The imaging results not only indicate the ability of terahertz wave in the non-invasive sensing and non-destructive inspection applications, but also prove the effectiveness and superiority of the uni-traveling-carrier photodiode as a terahertz source in the imaging applications.展开更多
The geometric and spatial characteristics of pore structures determine the permeability and water retention of soils, which have important effects on soil functional diversity and ecological restoration. Until recentl...The geometric and spatial characteristics of pore structures determine the permeability and water retention of soils, which have important effects on soil functional diversity and ecological restoration. Until recently, there have not been tools and methods to visually and quantitatively describe the characteristics of soil pores. To solve this problem, this research reconstructs the geometry and spatial distribution of soil pores by the marching cubes method, texture mapping method and the ray casting method widely used in literature. The objectives were to explore an optimal method for three-dimensional visualization of soil pore structure by comparing the robustness of the three methods on soil CT images with single pore structure and porosity ranging from low (2–5%) to high (12–18%), and to evaluate the reconstruction performance of the three methods with different geometric features. The results demonstrate that there are aliases (jagged edges) and deficiency at the boundaries of the model reconstructed by the marching cubes method and pore volumes are smaller than the ground truth, whereas the results of the texture mapping method lack the details of pore structures. For all the soil images, the ray casting method is preferable since it better preserves the pore characteristics of the ground truth. Furthermore, the ray casting method produced the best soil pore model with higher rendering speed and lower memory consumption. Therefore, the ray casting method provides a more advanced method for visualization of pore structures and provides an optional technique for the study of the transport of moisture and the exchange of air in soil.展开更多
基金supported by the National Natural Science Foundation of China(Grant No.12474461)the Basic and Frontier Exploration Project Independently Deployed by Institute of Acoustics,Chinese Academy of Sciences(Grant No.JCQY202402)the Goal-Oriented Project Independently Deployed by Institute of Acoustics,Chinese Academy of Sciences(Grant No.MBDX202113).
文摘Full waveform inversion(FWI)is a complex data fitting process based on full wavefield modeling,aiming to quantitatively reconstruct unknown model parameters from partial waveform data with high-resolution.However,this process is highly nonlinear and ill-posed,therefore achieving high-resolution imaging of complex biological tissues within a limited number of iterations remains challenging.We propose a multiscale frequency–domain full waveform inversion(FDFWI)framework for ultrasound computed tomography(USCT)imaging of biological tissues,which innovatively incorporates Sobolev space norm regularization for enhancement of prior information.Specifically,we investigate the effect of different types of hyperparameter on the imaging quality,during which the regularization weight is dynamically adapted based on the ratio of the regularization term to the data fidelity term.This strategy reduces reliance on predefined hyperparameters,ensuring robust inversion performance.The inversion results from both numerical and experimental tests(i.e.,numerical breast,thigh,and ex vivo pork-belly tissue)demonstrate the effectiveness of our regularized FWI strategy.These findings will contribute to the application of the FWI technique in quantitative imaging based on USCT and make USCT possible to be another high-resolution imaging method after x-ray computed tomography and magnetic resonance imaging.
文摘Objective To compare contrast-enhanced magnetic resonance imaging (ceMRI) with nuclear metabolic imaging for the assessment of myocardial viability in patients with chronic ischemic heart disease. Methods Twenty patients with suspected chronic ischemic heart disease underwent ceMRI and technetium-99m sestamibi single-photon emission computed tomography (SPECT). Patients with positive SPECT results also underwent 18 F-fluorodeoxyglucose (FDG) SPECT. In a 17-segment model, the segmental extent of hyperenhancement (SEH) by ceMRI was compared with segmental FDG and sestamibi uptake by SPECT. Correlation between the extent of hyperenhancement by ceMRI and left ventricular function was analyzed. Seven patients got negative results both in ceMRI and technetium-99m sestamibi SPECT. The rest 13 patients with positive results then underwent ^18F-FDG SPECT. In 221 segments of 13 patients, SEH was (2. 1±8.2)%, (25.0±13.7 )%, and (57. 7±23.6 )% in segments with normal metabolism/perfusion, metabolism/perfusion mismatch, and matched defects, respectively, and there were significant differences between either two of them ( all P 〈 0.05). By receiver operating characteristic curve analysis, the area under the curve was 0. 95 for the differentiation between viable and non-viable segments. At the cutoff value of 34%, SEH optimally differentiated viable from non-viable segments defined by SPECT. Using this threshold, the sensitivity and specificity of ceMRI to detect non-viable myocardium as defined by SPECT were 92% and 93%, respectively. Hyperenhancement size by ceMRI was correlated negatively with the left ventricular ejection fraction ( r = - 0.90, P 〈 0.01 ) and positively with left ventricular volumes ( r = 0. 62 for end-diastolic volume, r = 0.75 for end-systolic volume, both P 〈 0.05 ). Conclusion CeMRI allows assessment of myocardial viability with a high accuracy in patients with chronic ischemic heart disease.
基金supported by the National Natural Science Foundation of China(Nos.12375157,12027902,and 11905011)。
文摘Purpose To propose a method for simultaneous fluorescence and Compton scattering computed tomography by using linearly polarized X-rays.Methods Monte Carlo simulations were adopted to demonstrate the feasibility of the proposed method.In the simulations,the phantom is a polytetrafluoroethylene cylinder inside which are cylindrical columns containing aluminum,water,and gold(Au)-loaded water solutions with Au concentrations ranging between 0.5 and 4.0 wt%,and a parallel-hole collimator imaging geometry was adopted.The light source was modeled based on a Thomson scattering X-ray source.The phantom images for both imaging modalities were reconstructed using a maximumlikelihood expectation maximization algorithm.Results Both the X-ray fluorescence computed tomography(XFCT)and Compton scattering computed tomography(CSCT)images of the phantom were accurately reconstructed.A similar attenuation contrast problem for the different cylindrical columns in the phantom can be resolved in the XFCT and CSCT images.The interplay between XFCT and CSCT was analyzed,and the contrast-to-noise ratio(CNR)of the reconstruction was improved by correcting for the mutual influence between the two imaging modalities.Compared with K-edge subtraction imaging,XFCT exhibits a CNR advantage for the phantom.Conclusion Simultaneous XFCT and CSCT can be realized by using linearly polarized X-rays.The synergy between the two imaging modalities would have an important application in cancer radiation therapy.
文摘BACKGROUND:Patients who present to the emergency department(ED)for suspected pulmonary embolism(PE)are often on active oral anticoagulation(AC).However,the diagnostic yield of computed tomography pulmonary angiography(CTPA)in screening for PE in patients who present on AC has not been well characterized.We aim to investigate the diagnostic yield of CTPA in diagnosing PE depending on AC status.METHODS:We reviewed and analyzed the electronic medical records of patients who underwent CTPA for PE at a university hospital ED from June 1,2019,to March 25,2022.Primary outcome was the incidence of PE on CTPA depending on baseline AC status and indication for AC.RESULTS:Of 2,846 patients,242 were on AC for a history of venous thromboembolism(VTE),210 were on AC for other indications,and 2,394 were not on AC.The incidence of PE on CTPA was significantly lower in patients on AC for other indications(5.7%)when compared to patients on AC for prior VTE(24.3%)and patients not on AC at presentation(9.8%)(P<0.001).In multivariable analysis among the whole cohort,AC was associated with a positive CTPA(odds ratio[OR]0.26,95%confidence interval[CI]:0.15-0.45,P<0.001).CONCLUSION:The incidence of PE among patients undergoing CTPA in the ED is lower in patients previously on AC for indications other than VTE when compared to those not on AC or those on AC for history of VTE.AC status and indication for AC may affect pre-test probability of a positive CTPA,and AC status therefore warrants consideration as part of future diagnostic algorithms among patients with suspected PE.
基金supported by the Tehran University of Medical Sciences under Grant No.36291PET/CT and Cyclotron Center of Masih Daneshvari Hospital at Shahid Beheshti University of Medical Sciences。
文摘Image quality in positron emission tomography(PET)is affected by random and scattered coincidences and reconstruction protocols.In this study,we investigated the effects of scattered and random coincidences from outside the field of view(FOV)on PET image quality for different reconstruction protocols.Imaging was performed on the Discovery 690 PET/CT scanner,using experimental configurations including the NEMA phantom(a body phantom,with six spheres of different sizes)with a signal background ratio of 4:1.The NEMA phantom(phantom I)was scanned separately in a one-bed position.To simulate the effect of random and scatter coincidences from outside the FOV,six cylindrical phantoms with various diameters were added to the NEMA phantom(phantom II).The 18 emission datasets with mean intervals of 15 min were acquired(3 min/scan).The emission data were reconstructed using different techniques.The image quality parameters were evaluated by both phantoms.Variations in the signal-to-noise ratio(SNR)in a 28-mm(10-mm)sphere of phantom II were 37.9%(86.5%)for ordered-subset expectation maximization(OSEM-only),36.8%(81.5%)for point spread function(PSF),32.7%(80.7%)for time of flight(TOF),and 31.5%(77.8%)for OSEM+PSF+TOF,respectively,indicating that OSEM+PSF+TOF reconstruction had the lowest noise levels and lowest coefficient of variation(COV)values.Random and scatter coincidences from outside the FOV induced lower SNR,lower contrast,and higher COV values,indicating image deterioration and significantly impacting smaller sphere sizes.Amongst reconstruction protocols,OSEM+PSF+TOF and OSEM+PSF showed higher contrast values for sphere sizes of 22,28,and 37 mm and higher contrast recovery coefficient values for smaller sphere sizes of 10 and 13 mm.
文摘Background Elderly patients generally have higher occurrence of coronary calcification, increased heart rate and difficulty with prolonged breath-holding. The aim of our study was to investigate the feasibility and accuracy of using 64-row multi-detector computed tomography (MDCT) in the assessment of coronary artery stenoses in elderly patients. Methods One hundred and fifty two patients with suspected or known coronary artery disease were divided into 4 groups according to their age (Group A: 40-49 years,n=34; Group B: 50-59 years, n=57; Group C: 60-69 years, n=48; Group D: 70 years and above; n=13). Coronary CT angiography (CTA) using a 64-row MDCT was performed and the findings were compared with that of conventional coronary angiography (CCA).Using axial images, multi-planar reconstructions (MPR) and maximum intensity projections (MIP), coronary segments of lumen diameter = 1.5mm were analyzed for the presence of significant stenosis (= 50% ). Results Percentages of poor image quality from coronary CTA preventing reliable correlations with CCA were 21%, 14%, 19% and 62% in Groups A to D respectively. Patients in Group D had significantly higher calcium scores compared with the other groups (P<0.001). In patients where CTA images were of acceptable quality, percentages of accurate correlations with CCA were 89.8%, 93.4%, 86.6% and 78.0% for Groups A to D respectively.There were no significant difference in serum creatinine, heart rate and contrast volume between the 4 groups. Conclusions The 64-row MDCT coronary angiography was less accurate and feasible for patients aged 70 years or above due to heavy coronary calcification and inability to perform a satisfactory breath-hold. However, a high diagnostic accuracy with the MDCT is possible in patients aged less than 70 years.
文摘Multislice CT angiography represents one of the most exciting technological revolutions in cardiac imaging and it has been increasingly used in the diagnosis of coronary artery disease. Rapid improvements in multislice CT scanners over the last decade have allowed this technique to become a potentially effective alternative to invasive coronary angiography in patients with suspected coronary artery disease. High diagnostic value has been achieved with multislice CT angiography with use of 64- and more slice CT scanners. In addition, multislice CT angiography shows accurate detection and analysis of coronary calcium, characterization of coronary plaques, as well as prediction of the disease progression and major cardiac events. Thus, patients can benefit from multislice CT angiography that provides a rapid and accurate diagnosis while avoiding unnecessary invasive coronary angiography procedures. The aim of this article is present an overview of the clinical applications of multislice CT angiography in coronary artery disease with a focus on the diagnostic accuracy of coronary artery disease; prognostic value of coronary artery disease with regard to the prediction of major cardiac events; detection and quantification of coronary calcium and characterization of coronary plaques. Limitations of multislice CT angiography in coronary artery disease are also briefly discussed, and future directions are highlighted.
文摘Objective To investigate the image quality, radiation dose and diagnostic value of the low-tube-voltage high-pitch dual-source computed tomography(DSCT) with sinogram affirmed iterative reconstruction(SAFIRE) for non-enhanced abdominal and pelvic scans. Methods This institutional review board-approved prospective study included 64 patients who gave written informed consent for additional abdominal and pelvic scan with DSCT in the period from November to December 2012. The patients underwent standard non-enhanced CT scans(protocol 1) [tube voltage of 120 k Vp/pitch of 0.9/filtered back-projection(FBP) reconstruction] followed by high-pitch non-enhanced CT scans(protocol 2)(100 k Vp/3.0/SAFIRE). The total scan time, mean CT number, signal-to-noise ratio(SNR), image quality, lesion detectability and radiation dose were compared between the two protocols. Results The total scan time of protocol 2 was significantly shorter than that of protocol 1(1.4±0.1 seconds vs. 7.6±0.6 seconds, P<0.001). There was no significant difference between protocol 1 and protocol 2 in mean CT number of all organs(liver, 55.4±6.3 HU vs. 56.1±6.8 HU, P=0.214; pancreas, 43.6±5.9 HU vs. 43.7±5.8 HU, P=0.785; spleen, 47.9±3.9 HU vs. 49.4±4.3 HU, P=0.128; kidney, 32.2±2.3 HU vs. 33.1±2.3 HU, P=0.367; abdominal aorta, 44.8±5.6 HU vs. 45.0±5.5 HU, P=0.499; psoas muscle, 50.7±4.1 HU vs. 50.3±4.5 HU, P=0.279). SNR on images of protocol 2 was higher than that of protocol 1(liver, 5.0±1.2 vs. 4.5±1.1, P<0.001; pancreas, 4.0±1.0 vs. 3.6±0.8, P<0.001; spleen, 4.7±1.0 vs. 4.1±0.9, P<0.001; kidney, 3.1±0.6 vs. 2.8±0.6, P<0.001; abdominal aorta, 4.1±1.0 vs. 3.8±1.0, P<0.001; psoas muscle, 4.5±1.1 vs. 4.3±1.2, P=0.012). The overall image noise of protocol 2 was lower than that of protocol1(9.8±3.1 HU vs. 11.1±3.0 HU, P<0.001). Image quality of protocol 2 was good but lower than that of protocol 1(4.1±0.7 vs. 4.6±0.5, P<0.001). Protocol 2 perceived 229 of 234 lesions(97.9%) that were detected in protocol 1 in the abdomen and pelvis. Radiation dose of protocol 2 was lower than that of protocol 1(4.4±0.4 m Sv vs. 7.3±2.4 m Sv, P<0.001) and the mean dose reduction was 41.4%. Conclusion The high-pitch DSCT with SAFIRE can shorten scan time and reduce radiation dose while preserving image quality in non-enhanced abdominal and pelvic scans.
基金supported by the National Natural Science Foundation of China (No.11264032)the Aeronautical Science Foundation of China (No.2014ZD56007)+4 种基金the Science and Technology Project of General Administration of Quality Supervision,Inspection and Quarantine of China (No.2013zjjz180)the Natural Science Foundation of Jiangxi Province (No.20122BAB201024)the Science and Technology Project of the Education Department of Jiangxi Province (No.GJJ14530)the Innovation Foundation of Shanghai Aerospace(SAST201364)the Graduate Innovation Foundation of Nanchang Hangkong University (No.YC2013010)
文摘Stability and accuracy of the imaging results are still unmet practical demands for ultrasonic computed tomography(CT)of concrete material.To address these issues,a CT technique based on simulated annealing genetic algorithm(SAGA)is presented in this work.Firstly,a natural weight matrix with clear physical meaning is introduced in the inverse algorithm and then a quadric broadening objective function is formed according to the propagation characteristics of ultrasound in concrete.After that,the simulated annealing(SA)searching is added to speed up the inverse process and to improve the convergence and stability of the algorithm.Finally,the optimal inverse imaging results have been achieved by variable ectopic adaptive genetic algorithm.The numerical simulation experiments have shown that the usage of the correct priori information and the excellent characteristic of SAGA in searching the global minimum value of the function have produced accurate and effective results with stable numerical values.The imaging resolution is improved and the imagining results reflecting the inner defections of the tested objects are more reliable and accurate.
基金Project supported by the National Basic Research Program of China(Grant No.2006CB7057005)the National High Technology Research and Development Program of China(Grant No.2009AA012200)the National Natural Science Foundation of China (Grant No.60672104)
文摘With the development of the compressive sensing theory, the image reconstruction from the projections viewed in limited angles is one of the hot problems in the research of computed tomography technology. This paper develops an iterative algorithm for image reconstruction, which can fit the most cases. This method gives an image reconstruction flow with the difference image vector, which is based on the concept that the difference image vector between the reconstructed and the reference image is sparse enough. Then the l1-norm minimization method is used to reconstruct the difference vector to recover the image for flat subjects in limited angles. The algorithm has been tested with a thin planar phantom and a real object in limited-view projection data. Moreover, all the studies showed the satisfactory results in accuracy at a rather high reconstruction speed.
文摘To evaluate the value of 16-slice spiral CT in the demonstration of coronary artery and in the diagnose of coronary artery stenosis. Methods Plain and enhanced CT scans were performed with a 16-slice CT scanner (Sensation 16, Siemens, Germany) in 230 patients with suspected coronary heart disease (CHD). Parameters of the plain scan were: 120 kV, 133 mA, slice col-limation 16 mm×1.5 mm, rotation time 0.42 seconds, increment 1.5 mm, and slice width 3 mm. Parameters of the enhanced scan were: 120 kV, 500 mA, slice collimation 16 mm×0.75 mm, rotation time 0.42 seconds, increment 0.5 mm, and slice width 1 mm. Enhanced CT scan was performed with a rapid intravenous injection of 100 mL iothalamate meglumine (Ultravist) (370 mgI/mL) or Omnipaque (350 mgI/mL) and 30 mL 0.9% NaCl chaser bolus at a flow rate of 3.5 mL/s. Calcium scoring with plain scan images and two and three dimensional reconstruction with enhanced scan images were made in all cases, among which 30 cases underwent conventional coronary angiography. Demonstration of coronary arteries and their stenosis were evaluated and the factors that might influence the image quality were analyzed. Results Coronary calcium scores were calculated and coronary artery was demonstrated in our study. In the evaluationof image quality with volume rendering technique (VRT) images, 78.3% of the images were of the first class, 12.2% the sec-ond class, and 9.6% the third class. Multi-planar reconstruction (MPR) and maximal intensity projection (MIP) were better than VRT in the demonstration of small branches. The image quality was related to the heart rate, with or without arrhythmia, and breath-hold ability of patients. Comparative study of the stenosis of coronary arteries in 30 cases showed that the sensi-tivity and specificity of 16-slice coronary CT angiography (CTA) to diagnose significant stenosis were 95.8% and 94.8% resp-ectively. Conclusion As a non-invasive and quick method, 16-slice coronary CTA is sensitive and specific to diagnose the stenosis of coronary arteries and can be used as a screening method in the diagnosis of CHD.
文摘Objective To explore the perihematomal perfusion typing and spot sign on computed tomography angiography(CTA) source images in order to assist in individualizing therapeutic decisions for patients with intracerebral hemorrhage by possibly forecasting perihematomal ischemia and hematoma enlargement. Methods We examined 58 patients with spontaneous intracerebral hemorrhage by computed tomography perfusion and CTA within 6 hours after symptom onset. Hematoma volumes were determined from non-contrast CT images and compared between first and second CT images. The perfusion of hematoma region and perihematoma region was evaluated for presence or absence of the perihematomal penumbra. Three kinds of perihematoma perfusion typing were defined according to the perfusion of hematoma region and perihematoma region. CTA source images was reviewed to make sure presence or absence of the spot sign. Results Finally, 53 patients(34 males, 19 females) were enrolled in our study according to exclusion criteria. Finally, 21 patients were classified into the normal group, 23 patients were classified into the mild group, and 9 patients were classified into the severe group. There were significant differences in hematoma size between the presence and absence of the perihematomal penumbra group(P<0.05). Thirteen(24.5%) patients presented with spot sign. Hematoma expansion occurred in 15(28.3%) patients on follow-up. In which 12 patients were with spot sign. Sensitivity, specificity, positive predictive value, and negative predictive value for expansion were 80.0%, 97.4%, 92.3%, and 92.5%, respectively. Conclusion In acute intracerebral hemorrhage patients, the perihematoma perfusion typing and CTA spot sign provide more radiological information that might assist in individualizing therapeutic decisions for patients by possibly forecasting perihematomal ischemia and hematoma enlargement.
文摘Objective To compare 16-slice multi-detector spiral computed tomography (MDCT) and breathhold 3D magnetic resonance (MR) coronary angiography in the visualization of coronary arteries and the accuracy of detecting significant (> 50%) coronary stenoses in patients with suspected coronary artery disease. Methods Forty patients were examined by 16-slice CT (GE, Lightspeedl6)and MR (GE,Twinspeed) within 3 days; 31 of them underwent conventional coronary angiography (CAG) within 2 weeks after CT and MR scan. CT was performed with 16× 1.25 mm detector collimation, 0.5 s rotation time and images were reconstructed at 60%-75% of the cardiac cycle. MR was performed with breath hold 3D FIESTA (TR4.0 ms, TE1.7 ms, flip angle 65, slice thickness 3 mm, FOV 280 mm, matrix 256× 192). Mean heart rate was 63 ± 5.8 bpm and β-blocker was used in 24 patients. MR and CT image quality was evaluated in 9 coronary segments (RCA1, RCA2, RCA3, LM, LAD1, LAD2, LAD3, LCX1, LCX2) using a four-point grading scale.Sensitivity, specificity, positive predictive value, negative predictive value and accuracy were calculated for detection of significant stenosis using CAG as the gold standard. Results 16-slice CT showed higher image quality in most coronary segments except RCA2.Forty-three segments were diagnosed as significant stenosis by CAG, 36 and 27 of these were correctly detected by CT and MR respectively. Sensitivity, specificity, positive predictive value, and negative predictive value of 16-slice CT and MR for detecting significant stenosis were 83 %, 84 %, 49 %, 97 % and 63 %, 90 %, 55 %, 93 %, respectively. Conclusion Sixteen-slice CT showed higher image quality in most coronary segments excepted for middle RCA. 16-slice CT had higher sensitivity than MR for detection of coronary significant stenosis, whereas MR had higher specificity than CT. Both CT and MR showed high negative predictive value,which is useful for excluding coronary stenosis in symptomatic patients.
文摘Objective To assess lumen visibility of coronary stents by 64-slice computed tomography (CT) coronary angiography, and determine the value of 64-slice CT in non-invasive detecting of in-stent restenosis after coronary artery stent implantation. Methods Totally, 60 patients (54 males, aged 57.0±12.7 years) and /05 stents were investigated by 64-slice CT at a mean interval of 20.0±16.6 months after coronary stents implantation. Axial multi-planar reconstruction images of the stents and curved-planar reconstruction images through the median of the stents were reconstructed for evaluating stent image quality on a 5-point scale (1=excellent, 5=nonassessable), and stent lumen diameter was detected. Conventional coronary angiography was performed in 18 patients, and 32 stents were evaluated. Results Image quality was good to excellent on average (score 1.71±0.76). Stent image quality score was correlated to heart rate (r=0. 281, P〈0.01) and stent diameter (r=-0.480, P〈0.001). All the stents were assessable in lumen visibility with an average visible lumen diameter percentage of 60.7%±13.6%. Visible lumen diameter percentage was correlated to heart rate (r=-0.193, P〈0.05), stent diameter (r=0.403, P〈0.001), and stent image quality score (r=-0.500, P〈0.001). Visible lumen diameter percentage also varied depending on the stent type. In comparison with the conventional coronary angiography, 4 of 6 in-stent stenoses were correctly detected. The sensitivity and specificity for the detection of in-stent stenosis were 66.7% and 84.6%, respectively. Conclusions Using a 64-slice CT, the stent lumen is partly visible in most of the stents. And 64-slice CT may be useful in the assessment of stent patency.
文摘Objective To explore the scan technique and image quality of coronary angiography with dual source computed tomography(CT) without oral metoprolol preparation.Methods Plain and enhanced dual source CT coronary angiography without oral metoprolol preparation was prospectively performed in 600 patients.Calcium scoring with plain scan images as well as multi-planar reconstruction(MPR),maximum intensity projection(MIP),and volume rendering technique(VRT) reconstruction with enhanced scan images were performed in all cases.The scan technique and post-reconstruction experience was summarized.The image quality was classified as 1 to 4 points,and coronary segments classified according to the American Heart Association standards were evaluated.Results The average calcium score of the 600 cases was 213.6±298.7(0-3 216.5).The average heart rate of the enhanced scan was 82.1±16.2(47-139) bpm.The post-reconstruction methods with which coronary segments could be shown as best as possible consisted of single phase reconstruction method,two or more phases supplemented method,and electrocardiogram editing method.Altogether 8 457 coronary segments were evaluated,among which 97.2% were evaluated as point 1,1.7% point 2,0.5% point 3,and 0.6% point 4.The coronary segments in 261 cases were completely normal,while 360 segments were diagnosed with <50% stenosis and 625 segments with ≥50% stenosis.Conclusions Excellent coronary artery image can be obtained with dual source CT in patients with any heart rate without oral metoprolol preparation.Heart rate is not a major source of the artifact,coronary segments can be well shown with single or multiple-phase reconstruction method.
基金supported by the Strategic Priority Research Program of the Chinese Academy of Sciences(No.XDB1002010)the Major Program for the Fundamental Research of Shanghai Committee of Science and Technology(No.12JC1410400)the National Natural Science Foundation of China for Distinguished Young Scholars(No.41325016)
文摘Microstructure of shale formation is the key to understanding its petrophysical and chemical properties.Optical microscopy, scanning electron microscopy and micro-computed tomography(μ-CT) have been combined for characterization of microstructure of Longmaxi(LMX)shale from Shizhu area, Sichan Basin. The results indicate that laminated LMX shale consists of mineral matrix-rich layers and organic matter(OM)-rich layers at micrometer scale in two and three dimensions. Mineral matrix layers,mainly consisting of interparticle pores and intraplatelet pores, are approximately parallel to the bedding plane.Pyrite-rich layer, mainly containing intercrystalline pores,shows a strong preferred orientation parallel to the bedding plane. OM-rich layer, mainly containing OM pores, seems to be discontinuous. In addition, intercrystalline pores are enriched in some layers, while OM pores are distributed irregularly in matrix layers. This vertical heterogeneity of pore microscopic structures in LMX shale is of great importance to understand its petrophysical and chemical properties.
基金This study was supported by Ruiyi Special Fund for Emergency Medicine Research(R2019019)Postgraduate Research&Practice Innovation Program of Jiangsu Province(SJCX20_0481).Ethical approval:。
文摘BACKGROUND:To assess the association between relevant brain computed tomography(CT)parameters at different time and neurological prognosis in adult comatose survivors after cardiac arrest(CA).METHODS:A total of 94 CA patients who underwent early and late CT scans(within 24 h and 24 h to 7 d respectively after CA)between January 2018 and April 2020 were enrolled in this retrospective study.According to the Cerebral Performance Category(CPC)score at hospital discharge,the patients were divided into either a good outcome(CPC 1-2)group or a poor-outcome group(CPC 3-5).The grey-to-white matter ratio(GWR)and the proportion of cerebrospinal fluid volume(pCSFV)were measured.In predicting poor outcomes,the prognostic performance of relevant CT parameters was evaluated,and the comparison analysis(expressed as the ratio of parameters in late CT to those in the early CT)of diff erent CT time was conducted.RESULTS:Totally 26 patients were in the good-outcome group,while 68 patients were in the poor-outcome group.The putamen density,GWR,and pCSFV in late CT were significantly lower in the poor-outcome group(P<0.05).The ratios of GWR and pCSFV in the poor-outcome group were signifi cantly decreased according to comparison analysis of diff erent CT time(P<0.05),while there was no signifi cant diff erence in the ratio of putamen density.GWR-basal ganglia<1.18 in late CT showed the best predictive value.The ratio of pCSFV<0.98 predicted unfavorable neurological outcomes with a sensitivity of 65.9%and a specifi city of 93.8%(P=0.001).CONCLUSIONS:Brain CT performed>24 h after CA may be a good choice as a neuroimaging approach to evaluating prognosis.To predict neurological prognosis,comparison analysis of diff erent CT time can be used as another promising tool in comatose CA survivors.
文摘Although the average age of diagnosis for aorticdissection is 63,[1] this case demonstrates the need toconsider AD in younger patients, particularly in thepresence of risk factors or in the absence of anotherreasonable diagnosis. This case suggests PCP use as aprecipitant for hypertension and sympathomimetic stresson the aorta. Despite high sensitivity, false negativeCTA imaging for AD can occur. If pretest probabilityremains high, further imaging must be obtained. Duringresuscitation in the ED, focused point-of-care ultrasoundcan also assist with medical decision making.
基金Supported by the Hundred Talents Program of Chinese Academy of Sciencesthe National Basic Research Program of China under Grant No 2014CB339803+2 种基金the Major National Development Project of Scientific Instrument and Equipment under Grant No2011YQ150021the National Natural Science Foundation of China under Grant Nos 61575214,61574155,61404149 and 61404150the Shanghai Municipal Commission of Science and Technology under Grant Nos 14530711300,15560722000 and 15ZR1447500
文摘Computed tomography has been proven to be useful for non-destructive inspection of structures and materials. We build a three-dimensional imaging system with the photonically generated incoherent noise source and the Schottky barrier diode detector in the terahertz frequency band (90–140GHz). Based on the computed tomography technique, the three-dimensional image of a ceramic sample is reconstructed successfully by stacking the slices at different heights. The imaging results not only indicate the ability of terahertz wave in the non-invasive sensing and non-destructive inspection applications, but also prove the effectiveness and superiority of the uni-traveling-carrier photodiode as a terahertz source in the imaging applications.
基金supported by the National Natural Science Foundation Project(41501283)Beijing Science and Technology Plan Project(Z161100000916012)+2 种基金the National Key Research and Development Program(2017YFD0600901)Special Fund for Beijing Common Construction Projectthe Fundamental Research Funds for the Central Universities(2015ZCQ-GX-04)
文摘The geometric and spatial characteristics of pore structures determine the permeability and water retention of soils, which have important effects on soil functional diversity and ecological restoration. Until recently, there have not been tools and methods to visually and quantitatively describe the characteristics of soil pores. To solve this problem, this research reconstructs the geometry and spatial distribution of soil pores by the marching cubes method, texture mapping method and the ray casting method widely used in literature. The objectives were to explore an optimal method for three-dimensional visualization of soil pore structure by comparing the robustness of the three methods on soil CT images with single pore structure and porosity ranging from low (2–5%) to high (12–18%), and to evaluate the reconstruction performance of the three methods with different geometric features. The results demonstrate that there are aliases (jagged edges) and deficiency at the boundaries of the model reconstructed by the marching cubes method and pore volumes are smaller than the ground truth, whereas the results of the texture mapping method lack the details of pore structures. For all the soil images, the ray casting method is preferable since it better preserves the pore characteristics of the ground truth. Furthermore, the ray casting method produced the best soil pore model with higher rendering speed and lower memory consumption. Therefore, the ray casting method provides a more advanced method for visualization of pore structures and provides an optional technique for the study of the transport of moisture and the exchange of air in soil.