The lethality of a semi-preformed fragment warhead is closely related to the expand velocity and spatial distribution of the fragments from ruptured metal casing. The topic of how to improve the utilization of charge ...The lethality of a semi-preformed fragment warhead is closely related to the expand velocity and spatial distribution of the fragments from ruptured metal casing. The topic of how to improve the utilization of charge of have been drawing great attention from researchers and designer in this filed. In present paper,in order to investigate the influence of charge initiation manners on the scattering characteristics of semi-preformed fragment warhead, the numerical simulations and experimental test are conducted.Firstly, the influence of grid density on numerical results is investigated, and a proper numerical model with relatively high accuracy and effectiveness is determined. Then. numerical simulations of three kinds of different initiation position of a semi-preformed fragment warhead are carried out. An experimental test of the explosion of a semi-preformed fragment warhead is carried out. By comparing and analyzing the numerical results and experimental data, it is found that the initiation manners have great influence on scattering characteristics of semi-preformed fragment warhead. The researcher work of this paper would provide an effective alternative method to optimize the design of warhead.展开更多
In this article,the viscoelastic damped was equation in three-dimensional cylindrical domain were studied by using a second-order differential inequality.We proved a Phragm´en-Lindelof alternative results,i.e.,th...In this article,the viscoelastic damped was equation in three-dimensional cylindrical domain were studied by using a second-order differential inequality.We proved a Phragm´en-Lindelof alternative results,i.e.,the smooth solutions either grow or decay exponentially as the distance from the entry section tends to infinity.Our results can be seen as a version of the Saint-Venant principle.展开更多
Niobium suboxide powder was pressed and sintered in vacuum into NbO electrolytic capacitor sintered anode..High voltage and constant current formation experiment was performed on NbO electrolytic capacitor anode,durin...Niobium suboxide powder was pressed and sintered in vacuum into NbO electrolytic capacitor sintered anode..High voltage and constant current formation experiment was performed on NbO electrolytic capacitor anode,during which electrolyte was 0.01 % Ha PO4 solution, temperature was 90 C and current was 50 mA per gram sample. Through the relationship between anode voltage and time and scanning electron microscopy(SEM) images of invalidated anode and normal forming anode, invalidation manner and mechanism of NbO electrolytic capacitor anode were discussed. The results show that, the main invalidation manner of NbO electrolytic capacitor anode is not short circuit but open circuit, which is different to that of traditional Ta electrolytic capacitor anode. The reason of invalidation is that anode oxide film whose thickness increases gradually penetrates the "connection neck" among anode powder particles, which leads to the open circuit invalidation of anode. Compared with Ta electrolytic capacitor,NbO electrolytic capacitor has better security.展开更多
基金supported by the Joint Foundation project for Young Scientists of Ministry of Education(6141A02033108)National Natural Science Foundation of China(11502180)
文摘The lethality of a semi-preformed fragment warhead is closely related to the expand velocity and spatial distribution of the fragments from ruptured metal casing. The topic of how to improve the utilization of charge of have been drawing great attention from researchers and designer in this filed. In present paper,in order to investigate the influence of charge initiation manners on the scattering characteristics of semi-preformed fragment warhead, the numerical simulations and experimental test are conducted.Firstly, the influence of grid density on numerical results is investigated, and a proper numerical model with relatively high accuracy and effectiveness is determined. Then. numerical simulations of three kinds of different initiation position of a semi-preformed fragment warhead are carried out. An experimental test of the explosion of a semi-preformed fragment warhead is carried out. By comparing and analyzing the numerical results and experimental data, it is found that the initiation manners have great influence on scattering characteristics of semi-preformed fragment warhead. The researcher work of this paper would provide an effective alternative method to optimize the design of warhead.
基金Supported by the Guangdong Natural Science foundation(2023A1515012044)Special Project of Guangdong Province in Key Fields of Ordinary Colleges and Universities(2023ZDZX4069)+1 种基金the Research Team of Guangzhou Huashang College(2021HSKT01)Guangzhou Huashang College’s Characteristic Research Projects(2024HSTS09)。
文摘In this article,the viscoelastic damped was equation in three-dimensional cylindrical domain were studied by using a second-order differential inequality.We proved a Phragm´en-Lindelof alternative results,i.e.,the smooth solutions either grow or decay exponentially as the distance from the entry section tends to infinity.Our results can be seen as a version of the Saint-Venant principle.
文摘Niobium suboxide powder was pressed and sintered in vacuum into NbO electrolytic capacitor sintered anode..High voltage and constant current formation experiment was performed on NbO electrolytic capacitor anode,during which electrolyte was 0.01 % Ha PO4 solution, temperature was 90 C and current was 50 mA per gram sample. Through the relationship between anode voltage and time and scanning electron microscopy(SEM) images of invalidated anode and normal forming anode, invalidation manner and mechanism of NbO electrolytic capacitor anode were discussed. The results show that, the main invalidation manner of NbO electrolytic capacitor anode is not short circuit but open circuit, which is different to that of traditional Ta electrolytic capacitor anode. The reason of invalidation is that anode oxide film whose thickness increases gradually penetrates the "connection neck" among anode powder particles, which leads to the open circuit invalidation of anode. Compared with Ta electrolytic capacitor,NbO electrolytic capacitor has better security.