The comparative research on the seismic performance of grouted sleeve connected pier(GS)and prestressed precast segmental concrete pier(PC)is mostly carried out by numerical simulation.In this study,the GS pier and th...The comparative research on the seismic performance of grouted sleeve connected pier(GS)and prestressed precast segmental concrete pier(PC)is mostly carried out by numerical simulation.In this study,the GS pier and the PC pier of the new railway project from Hetian to Ruoqiang are taken into consideration.Two kinds of 1/5-scale assembled double-column specimens are made,and the quasi-static tests are carried out.The overall seismic performance of the two spliced piers is studied,and compared in terms of failure mechanism,bearing capacity,ductility,stiffness and energy dissipation capacity.The results show that the failure modes of both GS pier and PC pier are characterized by bending.However,the specific failure location and form are different.The GS pier presents a complete hysteretic curve,large equivalent stiffness and strong energy dissipation capacity.The hysteretic area of the PC pier is small.However,it has good self-reset ability and quasi-static residual displacement.Finite element models are set up using DispBeamColumn fiber elements and ZeroLength elements.The models that are calibrated with the test data can effectively simulate the damage development under monotonic loading.The load−displacement curves are in good agreement with the backbone curves of the test results.展开更多
利用超高性能混凝土(ultra high performance concrete, UHPC)材料特性,提出一种针对预制拼装桥墩的重力灌浆构造,即采用UHPC灌浆并依靠立柱自身重力完成拼接的插槽式连接构造。为研究该形式桥墩的抗震性能,设计完成了三个桥墩的拟静力...利用超高性能混凝土(ultra high performance concrete, UHPC)材料特性,提出一种针对预制拼装桥墩的重力灌浆构造,即采用UHPC灌浆并依靠立柱自身重力完成拼接的插槽式连接构造。为研究该形式桥墩的抗震性能,设计完成了三个桥墩的拟静力试验,分别为整体现浇墩Z1、新型插槽式连接墩P1及现有“I型”连接墩P2,并采用OpenSees有限元软件做模拟分析,与试验结果对比分析。结果表明:三个桥墩的破坏形式一致,均为弯曲破坏;Z1墩与P1墩滞回曲线呈梭形,滞回环较为饱满,且相同位移加载循环下的滞回路径较为吻合,P2墩接口处钢筋与混凝土间黏结滑移影响较大,导致滞回环面积减小,桥墩整体滞回耗能能力降低;P1墩的耗能能力较Z1墩和P2墩分别提升7.0%、10.7%,呈现峰值荷载小、失效速率慢、极限位移大、滞回耗能多的骨架趋势。试验结果与有限元模拟结果较为吻合,抗震性能参数差幅在10.0%以内,新型插槽式连接墩可应用于实际工程。展开更多
基金Project(N2018G034)supported by China Railway Corporation。
文摘The comparative research on the seismic performance of grouted sleeve connected pier(GS)and prestressed precast segmental concrete pier(PC)is mostly carried out by numerical simulation.In this study,the GS pier and the PC pier of the new railway project from Hetian to Ruoqiang are taken into consideration.Two kinds of 1/5-scale assembled double-column specimens are made,and the quasi-static tests are carried out.The overall seismic performance of the two spliced piers is studied,and compared in terms of failure mechanism,bearing capacity,ductility,stiffness and energy dissipation capacity.The results show that the failure modes of both GS pier and PC pier are characterized by bending.However,the specific failure location and form are different.The GS pier presents a complete hysteretic curve,large equivalent stiffness and strong energy dissipation capacity.The hysteretic area of the PC pier is small.However,it has good self-reset ability and quasi-static residual displacement.Finite element models are set up using DispBeamColumn fiber elements and ZeroLength elements.The models that are calibrated with the test data can effectively simulate the damage development under monotonic loading.The load−displacement curves are in good agreement with the backbone curves of the test results.
文摘利用超高性能混凝土(ultra high performance concrete, UHPC)材料特性,提出一种针对预制拼装桥墩的重力灌浆构造,即采用UHPC灌浆并依靠立柱自身重力完成拼接的插槽式连接构造。为研究该形式桥墩的抗震性能,设计完成了三个桥墩的拟静力试验,分别为整体现浇墩Z1、新型插槽式连接墩P1及现有“I型”连接墩P2,并采用OpenSees有限元软件做模拟分析,与试验结果对比分析。结果表明:三个桥墩的破坏形式一致,均为弯曲破坏;Z1墩与P1墩滞回曲线呈梭形,滞回环较为饱满,且相同位移加载循环下的滞回路径较为吻合,P2墩接口处钢筋与混凝土间黏结滑移影响较大,导致滞回环面积减小,桥墩整体滞回耗能能力降低;P1墩的耗能能力较Z1墩和P2墩分别提升7.0%、10.7%,呈现峰值荷载小、失效速率慢、极限位移大、滞回耗能多的骨架趋势。试验结果与有限元模拟结果较为吻合,抗震性能参数差幅在10.0%以内,新型插槽式连接墩可应用于实际工程。