The neutral beam injection is widely adopted in tokamaks as a key heating tool,playing a crucial role in generating burning plasmas.However,the loss of beam ions can damage the first wall and reduce the heating effici...The neutral beam injection is widely adopted in tokamaks as a key heating tool,playing a crucial role in generating burning plasmas.However,the loss of beam ions can damage the first wall and reduce the heating efficiency,resulting in failure to maintain steady-state conditions.In this work,the effect of neutral particles in the edge on fast ions generated by NBI in the Experimental Advanced Superconducting Tokamak(EAST)device is studied using the particle tracer code(PTC).The poloidal distribution of neutral particles is calculated by edge plasma simulation code SOLPS-ITER.In this simulation,four beam lines in EAST are considered:co-current tangential(co-tang),co-current perpendicular(co-perp),counter-current tangential(ctr-tang)and counter-current perpendicular(ctr-perp).It is shown that,in the absence of neutral particles,the loss fraction of ctr-injection is considerably higher than that of the co-injection.When considering the neutral particles,it is found that the ctr-perp injection demonstrates a significant variation in particles loss fraction(ranging from 18.56%to 25.42%)compared to the other three injection configurations.In terms of the loss fraction induced by neutral particles,ctr-injection exceeds co-injection,and perpendicular configuration exceeds tangential configuration.Furthermore,the difference of charge exchange ratios of three different energy(full energy,half energy,one third energy)of the four injections can be attributed to variations in the poloidal trajectories associated with each of these injections.Moreover,approximately half of fast ions which undergo neutralization directly lose to the first wall while the rest re-enter the bulk plasma and re-ionize.Except for the ctr-tang injection,the reionization ions from the other three injections exhibit effective confinement.展开更多
Multiple broadband Alfvenic chirping modes(CMs),with frequencies in the wide range of f-35-150 kHz and chirping down rapidly,are found in HL-2A neutral beam injection plasmas,and the CMs can even coexist.The frequency...Multiple broadband Alfvenic chirping modes(CMs),with frequencies in the wide range of f-35-150 kHz and chirping down rapidly,are found in HL-2A neutral beam injection plasmas,and the CMs can even coexist.The frequency chirping down process can be completed within-1 ms,and the frequency shift can reach 30-50 kHz.The CMs propagate in ion diamagnetic drift directions poloidally.The toroidal mode number is confirmed to be n=1,2,3 and 4 for the f-35-65,55-90,70-120 and 100-150 kHz CMs,respectively.The CMs are more like to be energetic-particle continuum modes(EPMs),since the modes almost locate on the Alfven continuum.展开更多
EAST NBI束线综合测试台已研制完成并具备一台兆瓦级离子源测试运行的全套电源设备,包括离子源灯丝电源、弧电源、加速器电源、抑制极电源、偏转磁体电源及缓冲器电源等。介绍了EAST兆瓦级离子源进行起弧放电调试运行的方式,叙述了各套...EAST NBI束线综合测试台已研制完成并具备一台兆瓦级离子源测试运行的全套电源设备,包括离子源灯丝电源、弧电源、加速器电源、抑制极电源、偏转磁体电源及缓冲器电源等。介绍了EAST兆瓦级离子源进行起弧放电调试运行的方式,叙述了各套离子源电源系统的设计结构、技术特点及运行控制方式,分析了离子源电源系统稳定可靠运行需要解决的各个难点,给出了EAST束线样机进行高功率及长脉冲束引出测试运行的实验结果。展开更多
The power supply system of ion source for the Neutral Beam Injector (NBI) in the HT-7 superconducting tokamak is based on a single injector with one ion source that can deliver 700 kW of neutral beam power. Experiment...The power supply system of ion source for the Neutral Beam Injector (NBI) in the HT-7 superconducting tokamak is based on a single injector with one ion source that can deliver 700 kW of neutral beam power. Experiments and a discharges test on the ion source were successfully performed. In this paper, the circuit structures and features of every power supply are described and the results of the discharges test are presented.展开更多
Neutral beam injection (NBI) heating is one of the most efficient auxiliary plasma heating methods for fusion devices. The data acquisition control system (DACS) with PXI (pe- ripheral component interconnect exte...Neutral beam injection (NBI) heating is one of the most efficient auxiliary plasma heating methods for fusion devices. The data acquisition control system (DACS) with PXI (pe- ripheral component interconnect extensions for instrumentation) data acquisition card for the first NBI system in the experimental advanced superconducting tokamak (EAST) is presented in this paper. As an important sub-system, DACS is designed to obtain physical measurement signals in the EAST NBI system and to deal and store these data with the Lempel-Ziv-Oberhumer (LZO) lossless data compression algorithm, as well as offer convenient data call-back and access inter- faces to the user for examining and analyzing the data. Experimental results show that accurate data will ensure that researchers correctly analyze it and then properly adjust the experimental parameters or operation, so DACS should take a large step in improving experimental efficiency. Tile hardware and software sections are briefly presented in this paper, and now this system has been tested to be able to work reliably and steadily.展开更多
A transformer type iron core snubber, as a protective device against the stray capacitance during the breakdown in EAST, is analyzed in detail. Three kinds of topology are presented. Then with the analysis for equival...A transformer type iron core snubber, as a protective device against the stray capacitance during the breakdown in EAST, is analyzed in detail. Three kinds of topology are presented. Then with the analysis for equivalent circuit, the ranges of three key parameters, i.e., secondary side resistance, leakage inductance and snubber inductance, are determined. By con- sidering the saturation of the magnetic material, a design principle is Mso presented. A nearly 1:10 core snubber is tested. It is proved that a high permeability core with secondary resistor can restrain the discharge current effectively.展开更多
基金supported by the National Key R&D Program of China(No.2022YFE03090000)National Natural Science Foundation of China(No.11975068).
文摘The neutral beam injection is widely adopted in tokamaks as a key heating tool,playing a crucial role in generating burning plasmas.However,the loss of beam ions can damage the first wall and reduce the heating efficiency,resulting in failure to maintain steady-state conditions.In this work,the effect of neutral particles in the edge on fast ions generated by NBI in the Experimental Advanced Superconducting Tokamak(EAST)device is studied using the particle tracer code(PTC).The poloidal distribution of neutral particles is calculated by edge plasma simulation code SOLPS-ITER.In this simulation,four beam lines in EAST are considered:co-current tangential(co-tang),co-current perpendicular(co-perp),counter-current tangential(ctr-tang)and counter-current perpendicular(ctr-perp).It is shown that,in the absence of neutral particles,the loss fraction of ctr-injection is considerably higher than that of the co-injection.When considering the neutral particles,it is found that the ctr-perp injection demonstrates a significant variation in particles loss fraction(ranging from 18.56%to 25.42%)compared to the other three injection configurations.In terms of the loss fraction induced by neutral particles,ctr-injection exceeds co-injection,and perpendicular configuration exceeds tangential configuration.Furthermore,the difference of charge exchange ratios of three different energy(full energy,half energy,one third energy)of the four injections can be attributed to variations in the poloidal trajectories associated with each of these injections.Moreover,approximately half of fast ions which undergo neutralization directly lose to the first wall while the rest re-enter the bulk plasma and re-ionize.Except for the ctr-tang injection,the reionization ions from the other three injections exhibit effective confinement.
基金Supported by the National Key R&D Program of China (Grant Nos.2018YFE0304102,2019YFE03020000 and 2017YFE0301202)the National Natural Science Foundation of China (Grant Nos.11875024,11875021,11835010 and 12005054)the Sichuan Provincial Science and Technology Project (Grant Nos.2020YFSY0047 and 2020JDJQ0070)。
文摘Multiple broadband Alfvenic chirping modes(CMs),with frequencies in the wide range of f-35-150 kHz and chirping down rapidly,are found in HL-2A neutral beam injection plasmas,and the CMs can even coexist.The frequency chirping down process can be completed within-1 ms,and the frequency shift can reach 30-50 kHz.The CMs propagate in ion diamagnetic drift directions poloidally.The toroidal mode number is confirmed to be n=1,2,3 and 4 for the f-35-65,55-90,70-120 and 100-150 kHz CMs,respectively.The CMs are more like to be energetic-particle continuum modes(EPMs),since the modes almost locate on the Alfven continuum.
基金The project supported by the Chinese Academy of Sciences (No. SYKXD04)
文摘The power supply system of ion source for the Neutral Beam Injector (NBI) in the HT-7 superconducting tokamak is based on a single injector with one ion source that can deliver 700 kW of neutral beam power. Experiments and a discharges test on the ion source were successfully performed. In this paper, the circuit structures and features of every power supply are described and the results of the discharges test are presented.
基金supported by National Natural Science Foundation of China(No.11075183)
文摘Neutral beam injection (NBI) heating is one of the most efficient auxiliary plasma heating methods for fusion devices. The data acquisition control system (DACS) with PXI (pe- ripheral component interconnect extensions for instrumentation) data acquisition card for the first NBI system in the experimental advanced superconducting tokamak (EAST) is presented in this paper. As an important sub-system, DACS is designed to obtain physical measurement signals in the EAST NBI system and to deal and store these data with the Lempel-Ziv-Oberhumer (LZO) lossless data compression algorithm, as well as offer convenient data call-back and access inter- faces to the user for examining and analyzing the data. Experimental results show that accurate data will ensure that researchers correctly analyze it and then properly adjust the experimental parameters or operation, so DACS should take a large step in improving experimental efficiency. Tile hardware and software sections are briefly presented in this paper, and now this system has been tested to be able to work reliably and steadily.
基金supported in part by Auxiliary Heating Project of EAST upgradein part by Ph. D foundation of State Education Ministry of China(No. 20060248012)
文摘A transformer type iron core snubber, as a protective device against the stray capacitance during the breakdown in EAST, is analyzed in detail. Three kinds of topology are presented. Then with the analysis for equivalent circuit, the ranges of three key parameters, i.e., secondary side resistance, leakage inductance and snubber inductance, are determined. By con- sidering the saturation of the magnetic material, a design principle is Mso presented. A nearly 1:10 core snubber is tested. It is proved that a high permeability core with secondary resistor can restrain the discharge current effectively.