期刊文献+
共找到16篇文章
< 1 >
每页显示 20 50 100
Drilling-based measuring method for the c-φ parameter of rock and its field application 被引量:5
1
作者 Bei Jiang Fenglin Ma +5 位作者 Qi Wang Hongke Gao Dahu Zhai Yusong Deng Chuanjie Xu Liangdi Yao 《International Journal of Mining Science and Technology》 SCIE EI CAS CSCD 2024年第1期65-76,共12页
The technology of drilling tests makes it possible to obtain the strength parameter of rock accurately in situ. In this paper, a new rock cutting analysis model that considers the influence of the rock crushing zone(R... The technology of drilling tests makes it possible to obtain the strength parameter of rock accurately in situ. In this paper, a new rock cutting analysis model that considers the influence of the rock crushing zone(RCZ) is built. The formula for an ultimate cutting force is established based on the limit equilibrium principle. The relationship between digital drilling parameters(DDP) and the c-φ parameter(DDP-cφ formula, where c refers to the cohesion and φ refers to the internal friction angle) is derived, and the response of drilling parameters and cutting ratio to the strength parameters is analyzed. The drillingbased measuring method for the c-φ parameter of rock is constructed. The laboratory verification test is then completed, and the difference in results between the drilling test and the compression test is less than 6%. On this basis, in-situ rock drilling tests in a traffic tunnel and a coal mine roadway are carried out, and the strength parameters of the surrounding rock are effectively tested. The average difference ratio of the results is less than 11%, which verifies the effectiveness of the proposed method for obtaining the strength parameters based on digital drilling. This study provides methodological support for field testing of rock strength parameters. 展开更多
关键词 Digital drilling Rock crushing zone c-u parameter Measurement method Field application
在线阅读 下载PDF
Analysis and Application of the Synthetic Relative Measuring Method in On-Line Monitoring for Capacitive Equipment in Power Systems
2
作者 Qing Guo Li-Jun Qin Hua-Wei Jin 《Journal of Electronic Science and Technology》 CAS 2011年第3期270-277,共8页
On-line measurement for dielectric loss angle can effectively monitor the insulation condition of capacitive equipment in power systems. Synthetic relative measuring methods not only markedly overcome the shortcomings... On-line measurement for dielectric loss angle can effectively monitor the insulation condition of capacitive equipment in power systems. Synthetic relative measuring methods not only markedly overcome the shortcomings of traditional absolute measuring methods but also greatly improve the accuracy of dielectric loss angle measurement. However, synthetic relative measuring methods based on two or three pieces of capacitive equipment do not have the characteristic of generality. In this paper, a principle of synthetic relative measuring method is presented. The example of application for synthetic relative methods based on three and four pieces of capacitive equipment running in the same phase is taken to present the failure judgment matrices for N pieces of equipment. According to these matrices, the fault condition of N pieces of capacitive equipment can be watched, which is more general. Then some problems needing to be concerned along with two diagnostic methods used in diagnostic system are introduced. Finally, two programmable flow charts for the two methods are given and corresponding examples demonstrate their feasibility in practice. 展开更多
关键词 Index Terms-Capacitive equipment dielectric loss angle on-line monitoring synthetic relative measuring method failure judgment matrix.
在线阅读 下载PDF
A New Method for Measuring the Wall Charge Waveforms of AC PDP
3
作者 梁志虎 刘祖军 刘纯亮 《Plasma Science and Technology》 SCIE EI CAS CSCD 2004年第6期2567-2570,共4页
A new method is developed to measure the wall charge waveforms in coplanar alternating current plasma display panel (AC PDP). In the method, two groups of display electrodes are selected from a coplanar AC PDP and two... A new method is developed to measure the wall charge waveforms in coplanar alternating current plasma display panel (AC PDP). In the method, two groups of display electrodes are selected from a coplanar AC PDP and two capacitors are respectively connected with these two groups of display electrodes in series, and a measuring circuit and a reference circuit are thus constructed. With the help of special processing, discharge takes place in the cells included in the measuring circuit under a normal drive voltage but no discharge takes place in the cells included in the reference circuit under a normal drive voltage. The wall charge waveforms are obtained from the voltage difference between the two capacitors. Using the method, the wall charge waveforms are measured during resetting period, addressing period and sustaining period for the 304.8mm (12-inch) test PDP panel. The result shows that the wall voltage is about 96V during the sustaining period. 展开更多
关键词 plasma display panel wall charge measuring method
在线阅读 下载PDF
Measurement methods and analysis tools for rail irregularities:a case study for urban tram track 被引量:3
4
作者 Laura Chiacchiari Giuseppe Loprencipe 《Journal of Modern Transportation》 2015年第2期137-147,共11页
Rail irregularities, in particular for urban rail- way infrastructures, are one of the main causes for the generation of noise and vibrations. In addition, repetitive loading may also lead to decay of the structural e... Rail irregularities, in particular for urban rail- way infrastructures, are one of the main causes for the generation of noise and vibrations. In addition, repetitive loading may also lead to decay of the structural elements of the rolling stock. This further causes an increase in main- tenance costs and reduction of service life. Monitoring these defects on a periodic basis enables the network rail managers to apply proactive measures to limit further damage. This paper discusses the measurement methods for rail corrugation with particular regard to the analysis tools for evaluating the thresholds of acceptability in re- lation to the tramway Italian transport system. Further- more, a method of analysis has been proposed: an application of the methodology used for treating road profiles has been also utilized for the data processing of rail profilometric data. 展开更多
关键词 Rail corrugation Noise disturbance Measurement methods Continuous measurement Dataprocessing algorithm Wavebands filtering
在线阅读 下载PDF
Reliability of gas holdup measurements using the differential pressure method in a cyclone-static micro-bubble flotation column 被引量:1
5
作者 Xia Wencheng Yang Jianguo Wang Yuling 《Mining Science and Technology》 EI CAS 2011年第6期797-801,共5页
Gas holdup is one of the key parameters in flotation process. Gas holdup as measured by a differential pressure method was investigated and the relative errors compared to the average gas holdup from the volume expans... Gas holdup is one of the key parameters in flotation process. Gas holdup as measured by a differential pressure method was investigated and the relative errors compared to the average gas holdup from the volume expansion method. The errors were used to establish optimum measurement positions. The results show that the measurement position should be in the middle of the column and in the region half way from the center to the wall (the half-radius). The gas holdup along the axial direction is lower at the bottom and higher at the top of the floatation column. The gas holdup along the radial direction is lower near the wall and higher near the center of the flotation column. The average gas holdup measure- ment can be replaced by regional gas holdup values. 展开更多
关键词 Gas holdup distribution Differential pressure method Measurement positions Axial direction Radial direction
在线阅读 下载PDF
Scaled radar cross section measurement method for lossy targets via dynamically matching reflection coefficients in THz band
6
作者 Shuang Pang Yang Zeng +2 位作者 Qi Yang Bin Deng Hong-Qiang Wang 《Chinese Physics B》 SCIE EI CAS CSCD 2022年第6期759-764,共6页
In the terahertz band,the dispersive characteristic of dielectric material is one of the major problems in the scaled radar cross section(RCS)measurement,which is inconsistent with the electrodynamics similitude deduc... In the terahertz band,the dispersive characteristic of dielectric material is one of the major problems in the scaled radar cross section(RCS)measurement,which is inconsistent with the electrodynamics similitude deducted according to the Maxwell’s equations.Based on the high-frequency estimation method of physical optics(PO),a scaled RCS measurement method for lossy objects is proposed through dynamically matching the reflection coefficients according to the distribution of the object facets.Simulations of the model of SLICY are conducted,and the inversed RCS of the lossy prototype is obtained using the proposed method.Comparing the inversed RCS with the calculated results,the validity of the proposed method is demonstrated.The proposed method provides an effective solution to the scaled RCS measurement for lossy objects in the THz band. 展开更多
关键词 scaled measurement method radar cross section lossy targets TERAHERTZ
在线阅读 下载PDF
Improved Efficiency Test Method for the Motor Controller with SiC MOSFETs
7
作者 Wei Wang Qiang Song +1 位作者 Yiting Li Mukhtiar Ahmad 《Journal of Beijing Institute of Technology》 EI CAS 2020年第3期294-302,共9页
The traditional measurement method was inaccurate to evaluate the motor controller efficiency,which the measurement efficiency value could be more than 100%in practical testing experiments.To deal with this issue,an i... The traditional measurement method was inaccurate to evaluate the motor controller efficiency,which the measurement efficiency value could be more than 100%in practical testing experiments.To deal with this issue,an improved electrical measurement method for the motor controller efficiency is proposed in this paper,which is established by analyzing the power loss distribution and phase currents of the motor controller.It is demonstrated that the SiC MOSFET chips are the main power loss devices in the motor controller,accounting for more than 93.1%of the total power loss.The accuracy of the proposed method is compared with the traditional method in simulation.It shows that the test error of the efficiency obtained by the traditional method fluctuates on a large scale,which varied from 0.094%to 1.911%.Compared with the traditional method,the test error of the proposed method appears to be less than 0.083%,which provides significant guidance for the motor controller efficiency test and design. 展开更多
关键词 electrical measurement method motor controller efficiency power loss distribution SiC MOSFET
在线阅读 下载PDF
Similarity evaluation of stratum anti-drilling ability and a new method of drill bit selection
8
作者 YAN Tie XU Rui +4 位作者 SUN Wenfeng LIU Weikai HOU Zhaokai YUAN Yuan SHAO Yang 《Petroleum Exploration and Development》 CSCD 2021年第2期450-459,共10页
Considering the stratum anti-drilling ability,drill bit working conditions,drill bit application effect and drill bit economic benefits,the similarity of stratum anti-drilling ability was evaluated by grey relational ... Considering the stratum anti-drilling ability,drill bit working conditions,drill bit application effect and drill bit economic benefits,the similarity of stratum anti-drilling ability was evaluated by grey relational analysis theory to screen out candidate drill bits with reference values.A new comprehensive performance evaluation model of drill bit was established by constructing the absolute ideal solution,changing the relative distance measurement method,and introducing entropy weight to work out the closeness between the candidate drill bits and ideal drill bits and select the reasonable drill bit.Through the construction of absolute ideal solution,improvement of relative distance measurement method and introduction of entropy weight,the inherent defects of TOPSIS decision analysis method,such as non-absolute order,reverse order and unreasonable weight setting,can be overcome.Simple in calculation and easy to understand,the new bit selection method has good adaptability to drill bit selection using dynamic change drill bit database.Field application has proved that the drill bits selected by the new drill bit selection method had significant increase in average rate of penetration,low wear rate,and good compatibility with the drilled formations in actual drilling.This new method of drill bit selection can be used as a technical means to select drill bits with high efficiency,long life and good economics in oilfields. 展开更多
关键词 drill bit selection stratum anti-drilling ability grey relational analysis absolutely ideal solution relative distance measurement method entropy weight comprehensive performance of drill bit
在线阅读 下载PDF
Fast Measurement of Dielectric Conductivity for Space Application by Surface Potential Decay Method 被引量:1
9
作者 全荣辉 周凯 +2 位作者 方美华 池卫英 张振龙 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第6期104-106,共3页
Surface potential decay of polymers for electrical insulation can help to determine the dark conductivity for spacecraft charging analysis. Due to the existence of radiation-induced conductivity, it decays fast in the... Surface potential decay of polymers for electrical insulation can help to determine the dark conductivity for spacecraft charging analysis. Due to the existence of radiation-induced conductivity, it decays fast in the first few hours after irradiation and exponentially slowly for the remaining time. The measurement of dark conductivity with this method usually takes the slow part and needs a couple of days. Integrating the Fowler formula into the deep dielectric charging equations, we obtain a new expression for the fast decay part. The experimental data of different materials, dose rates and temperatures are fitted by the new expression. Both the dark conductivity and the radiation-induced conductivity are derived and compared with other methods. The result shows a good estimation of dark conductivity and radiation-induced conductivity in high-resistivity polymers, which enables a fast measurement of dielectric conductivity within about 600 rain after irradiation. 展开更多
关键词 Fast Measurement of Dielectric Conductivity for Space Application by Surface Potential Decay method
在线阅读 下载PDF
Express Methods for Measurement of Electroconductivity of Semiconductor Layered Crystal
10
作者 FILIPPOV V. V. VLASOV A. N. 《Chinese Physics Letters》 SCIE CAS CSCD 2015年第11期114-117,共4页
We describe theoretically the grounded method of measuring the conductivity of anisotropic layered semiconductor materials. The suggested method implies the use of a four-probe testing device with a linear arrangement... We describe theoretically the grounded method of measuring the conductivity of anisotropic layered semiconductor materials. The suggested method implies the use of a four-probe testing device with a linear arrangement of probes. The final expressions for identifying the electrical conductivity are presented in the form of a series of analytic functions. The suggested method is experimentally verified, and practical recommendations of how to apply it are also provided. 展开更多
关键词 Express methods for Measurement of Electroconductivity of Semiconductor Layered Crystal
在线阅读 下载PDF
Temporally Modulated Phase Retrieval Method for Weak Temporal Phase Measurement of Laser Pulses
11
作者 姚玉东 乔治 +2 位作者 汪小超 范薇 林尊琪 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第3期29-33,共5页
We propose a simple iterative algorithm based on a temporally movable phase modulation process to retrieve the weak temporal phase of laser pulses. This unambiguous method can be used to achieve a high accuracy and to... We propose a simple iterative algorithm based on a temporally movable phase modulation process to retrieve the weak temporal phase of laser pulses. This unambiguous method can be used to achieve a high accuracy and to simultaneously measure the weak temporal phase and temporal profile of pulses, which are almost transform- limited. A detailed analysis shows that this iterative method has valuable potential applications in the charac- terization of pulses with weak temporal phase. 展开更多
关键词 Temporally Modulated Phase Retrieval method for Weak Temporal Phase Measurement of Laser Pulses
在线阅读 下载PDF
Magnetic field regression using artificial neural networks for cold atom experiments
12
作者 陈子霆 黃建陶 +6 位作者 Bojeong Seo 黄明琛 Mithilesh K.Parit 何逸飞 甄浩廷 Jensen Li Gyu-Boong Jo 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第2期46-51,共6页
Accurately measuring magnetic fields is essential for magnetic-field sensitive experiments in areas like atomic,molecular,and optical physics,condensed matter experiments,and other areas.However,since many experiments... Accurately measuring magnetic fields is essential for magnetic-field sensitive experiments in areas like atomic,molecular,and optical physics,condensed matter experiments,and other areas.However,since many experiments are often conducted in an isolated environment that is inaccessible to experimentalists,it can be challenging to accurately determine the magnetic field at the target location.Here,we propose an efficient method for detecting magnetic fields with the assistance of an artificial neural network(NN).Instead of measuring the magnetic field directly at the desired location,we detect fields at several surrounding positions,and a trained NN can accurately predict the magnetic field at the target location.After training,we achieve a below 0.3%relative prediction error of magnetic field magnitude at the center of the vacuum chamber,and successfully apply this method to our erbium quantum gas apparatus for accurate calibration of magnetic field and long-term monitoring of environmental stray magnetic field.The demonstrated approach significantly simplifies the process of determining magnetic fields in isolated environments and can be applied to various research fields across a wide range of magnetic field magnitudes. 展开更多
关键词 ultracold gases trapped gases measurement methods and instrumentation
在线阅读 下载PDF
Simultaneous estimation of aerosol optical constants and size distribution from angular light-scattering measurement signals 被引量:3
13
作者 Zhen-Zong He Dong Liang +1 位作者 Jun-Kui Mao Xing-Si Han 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第5期564-572,共9页
The angular light-scattering measurement(ALSM) method combined with an improved artificial bee colony algorithm is introduced to determine aerosol optical constants and aerosol size distribution(ASD) simultaneousl... The angular light-scattering measurement(ALSM) method combined with an improved artificial bee colony algorithm is introduced to determine aerosol optical constants and aerosol size distribution(ASD) simultaneously. Meanwhile, an optimized selection principle of the ALSM signals based on the sensitivity analysis and principle component analysis(PCA)is proposed to improve the accuracy of the retrieval results. The sensitivity analysis of the ALSM signals to the optical constants or characteristic parameters in the ASD is studied first to find the optimized selection region of measurement angles. Then, the PCA is adopted to select the optimized measurement angles within the optimized selection region obtained by sensitivity analysis. The investigation reveals that, compared with random selection measurement angles, the optimized selection measurement angles can provide more useful measurement information to ensure the retrieval accuracy. Finally,the aerosol optical constants and the ASDs are reconstructed simultaneously. The results show that the retrieval accuracy of refractive indices is better than that of absorption indices, while the characteristic parameters in ASDs have similar retrieval accuracy. Moreover, the retrieval accuracy in studying L-N distribution is a little better than that in studying Gamma distribution for the difference of corresponding correlation coefficient matrixes of the ALSM signals. All the results confirm that the proposed technique is an effective and reliable technique in estimating the aerosol optical constants and ASD simultaneously. 展开更多
关键词 angular light-scattering measurement method aerosol optical constants aerosol size distribution inverse radiation problem
在线阅读 下载PDF
Calorimetric power measurements in the EAST ECRH system 被引量:2
14
作者 Weiye XU Handong XU +3 位作者 Fukun LIU Jian WANG Xiaojie WANG Yongzhong HOU 《Plasma Science and Technology》 SCIE EI CAS CSCD 2017年第10期91-102,共12页
In this paper, the measurement method of calorimetric power for an electron cyclotron resonance heating(ECRH) system for EAST is presented. This method requires measurements of the water flow through the cooling cir... In this paper, the measurement method of calorimetric power for an electron cyclotron resonance heating(ECRH) system for EAST is presented. This method requires measurements of the water flow through the cooling circuits and the input and output water temperatures in each cooling circuit. Usually, the inlet water temperature stability is controlled to obtain more accurate results.The influence of the inlet water temperature change on the measurement results is analyzed for the first time in this paper. Also, a novel temperature calibration method is proposed. This kind of calibration method is accurate and effective, and can be easily implemented. 展开更多
关键词 power measurement calorimetric method data acquisition EAST tokamak ECRH
在线阅读 下载PDF
Twelve Elastic Constants of Betula platyphylla Suk. 被引量:1
15
作者 WangLiyu LuZhenyou 《Forestry Studies in China》 CAS 2004年第1期37-41,共5页
Wood elastic constants are needed to describe the elastic behaviors of wood and be taken as an important design parameter for wood-based composite materials and structural materials. This paper clarified the relations... Wood elastic constants are needed to describe the elastic behaviors of wood and be taken as an important design parameter for wood-based composite materials and structural materials. This paper clarified the relationships between compliance coefficients and engineering elastic constants combined with orthotropic properties of wood, and twelve elastic constants of Betula platyphylla Suk. were measured by electrical strain gauges. Spreading the adhesive quantity cannot be excessive or too little when the strain flakes were glued. If excessive, the glue layer was too thick which would influence the strain flakes?performance, and if too little, glues plastered were not firm, which could not accurately transmit the strain. Wood as an orthotropic material, its modulus of elasticity and poissons ratios are related by two formulas:μij /Ei =μji /Ej and μij < (Ei /Ej)1/2. The results showed that the elastic constants of Betula platyphylla Suk. measured by electrical strain gauges were accurate and reliable. The results of shear elastic modulus GTL and GLR show a high linear regression correlation coefficient (> 0.95) between the reciprocal of elastic modulus MOE-1 and the square of the ratio of depth to length (h/l)2, which indicate that shear modulus values measured were reliable by three point bending experiment. 展开更多
关键词 WOOD method of electrical measurement elastic constant
在线阅读 下载PDF
Nondestructive measurement of thermal contact resistance for the power vertical double-diffused metal-oxide-semiconductor
16
作者 李睿 郭春生 +3 位作者 冯士维 石磊 朱慧 王琳 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第7期384-386,共3页
To obtain thermal contact resistance(TCR) between the vertical double-diffused metal-oxide-semiconductor(VDMOS) and the heat sink, we derived the relationship between the total thermal resistance and the contact f... To obtain thermal contact resistance(TCR) between the vertical double-diffused metal-oxide-semiconductor(VDMOS) and the heat sink, we derived the relationship between the total thermal resistance and the contact force imposed on the VDMOS. The total thermal resistance from the chip to the heat sink is measured under different contact forces, and the TCR can be extracted nondestructively from the derived relationship. Finally, the experimental results are compared with the simulation results. 展开更多
关键词 thermal contact resistance nondestructive measurement method structure function contact pressure
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部