The measurement of K shell fluorescence parameters is an easy and practical way to investigate the electronic structures of elements in alloys,compounds or complexes.Since the number of valence electrons will change t...The measurement of K shell fluorescence parameters is an easy and practical way to investigate the electronic structures of elements in alloys,compounds or complexes.Since the number of valence electrons will change the screening effect,the measured parameters will be affected from the changes.In this study,the measured parameters were investigated for sulphur element according to the number of CH_2 groups.For the experimental measurements,the samples were excited by 59.5keVγrays from a 241 Am annular radioactive source.The emitted K X-rays from the samples were counted by ab Ultra-LEGe detector with a resolution of 150 eV at 5.9keV.展开更多
局内问题及其解法的研究是优化领域研究热点之一 ,而有关局内问题解法的研究必将涉及相应的局外问题 .提出了局外 k -出租车调度问题 ,给出了问题的动态规划求解方法 ,并给出该问题的一个具体算例 .同时简要地介绍了局外 k -卡车调度问...局内问题及其解法的研究是优化领域研究热点之一 ,而有关局内问题解法的研究必将涉及相应的局外问题 .提出了局外 k -出租车调度问题 ,给出了问题的动态规划求解方法 ,并给出该问题的一个具体算例 .同时简要地介绍了局外 k -卡车调度问题的动态规划求解方法 .展开更多
雷击是影响±500 k V直流架空输电线路运行的重要因素,±500 k V直流线路避雷器的挂网试运行成功,为直流线路防雷改造提供了有效技术手段,但大规模的工程应用仍是空白。笔者结合±500 k V江城线直流线路避雷器安装项目,研究...雷击是影响±500 k V直流架空输电线路运行的重要因素,±500 k V直流线路避雷器的挂网试运行成功,为直流线路防雷改造提供了有效技术手段,但大规模的工程应用仍是空白。笔者结合±500 k V江城线直流线路避雷器安装项目,研究了±500 k V直流线路避雷器选型、选点原则,给出了不同塔型下直流线路避雷器的安装方案,并提出直线塔宜采用悬挂式安装方案,耐张塔宜采用地面支柱式安装方案。运行数据表明,笔者提出的±500 k V直流线路避雷器选型、选点原则防雷改造效果明显,安装方案达到线路安全运行要求,对±500 k V直流线路避雷器的推广应用和在运直流线路防雷改造工作具有重要的实践和借鉴意义。展开更多
基金The financial support from research foundation of Mustafa Kemal University(grant no:13121)is also gratefully acknowledged
文摘The measurement of K shell fluorescence parameters is an easy and practical way to investigate the electronic structures of elements in alloys,compounds or complexes.Since the number of valence electrons will change the screening effect,the measured parameters will be affected from the changes.In this study,the measured parameters were investigated for sulphur element according to the number of CH_2 groups.For the experimental measurements,the samples were excited by 59.5keVγrays from a 241 Am annular radioactive source.The emitted K X-rays from the samples were counted by ab Ultra-LEGe detector with a resolution of 150 eV at 5.9keV.
文摘雷击是影响±500 k V直流架空输电线路运行的重要因素,±500 k V直流线路避雷器的挂网试运行成功,为直流线路防雷改造提供了有效技术手段,但大规模的工程应用仍是空白。笔者结合±500 k V江城线直流线路避雷器安装项目,研究了±500 k V直流线路避雷器选型、选点原则,给出了不同塔型下直流线路避雷器的安装方案,并提出直线塔宜采用悬挂式安装方案,耐张塔宜采用地面支柱式安装方案。运行数据表明,笔者提出的±500 k V直流线路避雷器选型、选点原则防雷改造效果明显,安装方案达到线路安全运行要求,对±500 k V直流线路避雷器的推广应用和在运直流线路防雷改造工作具有重要的实践和借鉴意义。