Recognizing the underwater targets by the radiated noise information is one of the most significant subjects in the area of underwater acoustics. Based on the theory of auditory perception, a novel recognition approac...Recognizing the underwater targets by the radiated noise information is one of the most significant subjects in the area of underwater acoustics. Based on the theory of auditory perception, a novel recognition approach which consists of the algorithms of Bark-wavelet analysis, Hilbert-Huang transform and support vector machine is proposed. The performance of the proposed method is validated by comparing with traditional method and evaluated by the recognition experiments for SNRs of 0 dB, 5 dB, 10 dB, 15 dB and 20 dB.The results show that the average recognition rate of the method is above 88% and can be increased by 0.75 % to 6.25% under various SNR conditions compared to the baseline system.展开更多
为了检测触电时刻剩余电流中生物体触电支路电流信号的难题,应用Hilbert-Huang变换方法,确定了生物触电时剩余电流的固有模态函数中相关系数最大的IMF分量的局部幅值达34.02 m A,且与原信号相关性系数达到0.99,同时剩余电流与触电电流...为了检测触电时刻剩余电流中生物体触电支路电流信号的难题,应用Hilbert-Huang变换方法,确定了生物触电时剩余电流的固有模态函数中相关系数最大的IMF分量的局部幅值达34.02 m A,且与原信号相关性系数达到0.99,同时剩余电流与触电电流暂态过程频谱特性具有相似变化规律。以此为基础,应用生物电流信号高频IMF分量幅值的突变特征,作为触电故障时刻确定判据,建立生物触电故障时刻判定方法,实际数据的仿真处理正确率为94.17%;筛选剩余电流分解的相关性较高的有限个数的低频固有模态IMF分量,应用逐步多元线性回归方法,提出基于剩余电流固有模态分量的生物触电支路电流幅值检测方法,仿真试验结果的平均相对误差值5.46%,具有良好的适应性和实用性,为研发基于生物体触电电流而动作的剩余电流保护装置提供参考。展开更多
基金Sponsored by Program for New Century Excellent Talents in University ( NCET-08-0459)
文摘Recognizing the underwater targets by the radiated noise information is one of the most significant subjects in the area of underwater acoustics. Based on the theory of auditory perception, a novel recognition approach which consists of the algorithms of Bark-wavelet analysis, Hilbert-Huang transform and support vector machine is proposed. The performance of the proposed method is validated by comparing with traditional method and evaluated by the recognition experiments for SNRs of 0 dB, 5 dB, 10 dB, 15 dB and 20 dB.The results show that the average recognition rate of the method is above 88% and can be increased by 0.75 % to 6.25% under various SNR conditions compared to the baseline system.
文摘为了检测触电时刻剩余电流中生物体触电支路电流信号的难题,应用Hilbert-Huang变换方法,确定了生物触电时剩余电流的固有模态函数中相关系数最大的IMF分量的局部幅值达34.02 m A,且与原信号相关性系数达到0.99,同时剩余电流与触电电流暂态过程频谱特性具有相似变化规律。以此为基础,应用生物电流信号高频IMF分量幅值的突变特征,作为触电故障时刻确定判据,建立生物触电故障时刻判定方法,实际数据的仿真处理正确率为94.17%;筛选剩余电流分解的相关性较高的有限个数的低频固有模态IMF分量,应用逐步多元线性回归方法,提出基于剩余电流固有模态分量的生物触电支路电流幅值检测方法,仿真试验结果的平均相对误差值5.46%,具有良好的适应性和实用性,为研发基于生物体触电电流而动作的剩余电流保护装置提供参考。