Recent Status of Taiji Program in China 被引量:6
1
作者 LUO Ziren ZHANG Min WU Yueliang 《空间科学学报》 CAS CSCD 北大核心 2022年第4期536-538,共3页
The Taiji-1 satellite is a pilot satellite mission of Taiji program,which is used to verify Taiji’s key technology and also to testify the feasibility of Taiji roadmap.Taiji-1 was launched on 31 August 2019 and its d... The Taiji-1 satellite is a pilot satellite mission of Taiji program,which is used to verify Taiji’s key technology and also to testify the feasibility of Taiji roadmap.Taiji-1 was launched on 31 August 2019 and its designed mission was successfully completed.The in-orbit scientific achievements of Taiji-1 satellite in the first stage have been published and now it has entered the extended task phase.Taiji-2 will prepare all the technology needed by Taiji-3,and remove all the technical obstacles faced by Taiji-3. 展开更多
关键词 Gravitational wave Taiji program Global gravity field model
在线阅读 下载PDF
GOCE kinematic orbit adjustment for EGM validation and accelerometer calibration
2
作者 徐天河 孙张振 +2 位作者 江楠 陈康康 李敏 《Journal of Central South University》 SCIE EI CAS 2014年第6期2397-2403,共7页
The main principle and mathematical model of GOCE kinematic orbit adjustment for Earth gravity field model (EGM) validation and accelerometer calibration are presented. Based on 60 days GOCE kinematic orbits with 1-... The main principle and mathematical model of GOCE kinematic orbit adjustment for Earth gravity field model (EGM) validation and accelerometer calibration are presented. Based on 60 days GOCE kinematic orbits with 1-2 cm accuracy and accelerometer data from 2009-11-02 to 2009-12-31, the RMS-of-fit (ROF) of them using EGM2008, EIGEN-SC, ITG- GRACE2010S and GOCO01S up to 120, 150 and 180 degree and order (d/o) are evaluated and compared. The scale factors and biases of GOCE accelerometer data are calibrated and the energy balance method (EBM) is performed to test the accuracy of accelerometer calibration. The results show that GOCE orbits are also sensitive to EGM from 120 to 150 d/o. The ROFs of EGMs with 150 and 180 d/o are obviously better than those of EGMs with 120 d/o. The ROFs of GOCO01S and ITG-GRACE2010S are almost the same up to 120 and 150 d/o, which are about 3.3 cm and 1.8 cm, respectively. They are far better than those of EGM2008 and EIGEN-SC with the same d/o. The ROF of GOCO01S with 180 d/o is about 1.6 em, which is the best one among those EGMs. The accelerometer calibration accuracies (ACAs) of ITG-GRACE2010S and GOCO01S are obviously higher that those of EGM2008 and EIGEN-SC. The ACA of GOCO01S with 180 d/o is far higher than that of EGMs with 120 d/o, and a little higher than that of ITG-GRACE2010S with 150 d/o. I t is suggested that the newest released EGM such as GOCO01S or GOCO02S till at least 150 d/o should be chosen in GOCE precise orbit determination (POD) and accelerometer calibration. 展开更多
关键词 GOCE orbit adjustment Earth gravity field model kinematic orbit accelerometer calibration
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部