期刊文献+
共找到1,892篇文章
< 1 2 95 >
每页显示 20 50 100
REAL-TIME THREE-DIMENSIONAL ECHOCARDIOGRAPHY FOR QUANTIFYING LEFT VENTRICULAR MASS 被引量:4
1
作者 Hong-wenFei Xin-fangWang +5 位作者 Ming-xingXie LeiZhuang Li-xinChen Run-qingHuang YingYang JingWang 《Chinese Medical Sciences Journal》 CAS CSCD 2004年第3期230-232,共3页
To test the accuracy of real-time three-dimensional echocardiography (RT3DE) imaging system for evaluating left ventricular mass (LVM) in phantom and excised canine heart. Methods Ten left ventricular (LV) wall phanto... To test the accuracy of real-time three-dimensional echocardiography (RT3DE) imaging system for evaluating left ventricular mass (LVM) in phantom and excised canine heart. Methods Ten left ventricular (LV) wall phantoms made of two rubber-bursas, ten excised canine hearts underwent RT3DE and two-dimensional echocardiography (2DE). In RT3DE "full volume" imaging, the myocardial volume was mea-sured using 2,4,8, and 16-plane method with the analysis software of RT3DE. Mass was then calculated by multiplying the resulting myocardial volume by specific density of myocardial tissue. In 2DE the masses were measured by area-length meth-od. The true LV wall phantom mass was measured by water displacement and the canine LVM was weighed by anatomy, which served as a reference standard. We compared RT3DE or 2DE with true mass. Results In LV wall phantoms, RT3DE correlated with true masses strongly (r = 0.813-0.994) and weakly correlated between 2DE and true masses (r = 0.628). In excised canine hearts, there is an excellent correlation between RT3DE and true masses (r = 0.764-0.991), while 2DE value showed a lesser correlation (r = 0.514). There are no difference between RT-3DE and true masses (P > 0.05) but different between 2DE and true masses (P < 0.05). In different planes, there was no difference between 8-plane and 16-plane (P > 0.05) but different between 8-plane and 2, 4-plane (P < 0.05). Conclusion RT3DE can accurately quantify LVM and provide a new tool to evaluate LV function. For LVM by RT3DE, 8-plane measurement method is the best choice for accuracy and convenience. 展开更多
关键词 real-time three-dimensional echocardiography left ventricular mass
在线阅读 下载PDF
QUANTITATIVE ASSESSMENT OF MYOCARDIAL PERFUSION DEFECTS WITH REAL-TIME THREE-DIMENSIONAL MYOCARDIAL CONTRAST ECHOCARDIOGRAPHY 被引量:2
2
作者 Lei Zhuang Ming-xing Xie +2 位作者 Wei-juan Wang Xiang-xin Yang Tao Liu 《Chinese Medical Sciences Journal》 CAS CSCD 2006年第3期135-139,共5页
Objective To evaluate the feasibility and accuracy of measurement of myocardial perfusion defects with intravenous contrast-enhanced real-time three-dimensional echocardiography (CE-RT3DE). Methods RT3DE was performed... Objective To evaluate the feasibility and accuracy of measurement of myocardial perfusion defects with intravenous contrast-enhanced real-time three-dimensional echocardiography (CE-RT3DE). Methods RT3DE was performed in 21 open-chest mongrel dogs undergoing acute ligation of the left anterior descending artery (LAD, n=14) or distal branch of the left circumflex artery (LCX, n=7). A perfluorocarbon microbubble contrast agent was injected intravenously to assess the resulting myocardial perfusion defects with Philips Sonos-7500 ultrasound system. Evans blue dye was injected into the occluded coronary artery for subsequent anatomic identification of underperfused myocardium. In vitro anatomic measurement of myocardial mass after removal of the animal’s heart was regarded as the control. Blinded off-line calculation of left ventricular mass and perfusion defect mass from RT3DE images were performed using an interactive aided-manual tracing technique.Results Total left ventricular (LV) myocardial mass ranged from 38.9 to 78.5 (mean±SD: 60.0±10.1) g. The mass of perfusion defect ranged from 0 to 21.4 (mean±SD: 12.0±5.0) g or 0 to 27% of total LV mass (mean±SD: 19%±6%). The RT3DE estimation of total LV mass (mean±SD: 59.8±9.9 g) strongly correlated with the anatomic measurement (r=0.98; y=2.01+0.96x). The CE-RT3DE calculation of the mass of underperfused myocardium (mean±SD: 12.3±5.3 g) also strongly correlated with the anatomic measurement (r=0.96; y=-0.10+1.04x) and when expressed as percentage of total LV mass (r=0.95; y=-0.20+1.04x). Conclusions RT3DE with myocardial contrast opacification could accurately estimate underperfused myocardial mass in dogs of acute coronary occlusion and would play an important role in quantitative assessment of myocardial perfusion defects in patients with coronary artery disease. 展开更多
关键词 real-time three-dimensional echocardiography CONTRAST perfusion defects myocardial infarction
在线阅读 下载PDF
Real-time Three-dimensional Echocardiography in Assessment of Left Ventricular and Right Ventricular Volumes
3
作者 YingYang Xin-fangWang Ming-xingXie JingWang 《Chinese Medical Sciences Journal》 CAS CSCD 2004年第3期236-236,共1页
关键词 ADULT echocardiography three-dimensional Heart Ventricles Humans Stroke Volume Ventricular Function Left Ventricular Function Right
在线阅读 下载PDF
Assessment of Left Atrial Function by Full Volume Real-time Three-dimensional Echocardiography and Left Atrial Tracking in Essential Hypertension Patients with Different Patterns of Left Ventricular Geometric Models 被引量:9
4
作者 Yang Wang Lin Gao +1 位作者 Jian-bai Li Chao Yu 《Chinese Medical Sciences Journal》 CAS CSCD 2013年第3期152-158,共7页
Objective To evaluate left atrial function in essential hypertension patients with different patterns of left ventricular geometric models by real-time three-dimensional echocardiography (RT-3DE) and left atrial tra... Objective To evaluate left atrial function in essential hypertension patients with different patterns of left ventricular geometric models by real-time three-dimensional echocardiography (RT-3DE) and left atrial tracking (EAT). 展开更多
关键词 essential hypertension left atrial function three-dimensional echocardiography left atrial tracking
在线阅读 下载PDF
Role of real-time three-dimensional transesophageal echocardiography in mitral valve repair 被引量:1
5
作者 Cuizhen Pan~1 Xianhong Shu~1 Qiling Cao~2 Chunsheng Wang~1 Wenjun Ding~1 Haozhu Chen~1 1 Department of Echocardiography, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases, Shanghai 200032, China, 2 Rush University Medical Center, Chicago, USA 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2008年第3期137-141,共5页
Background and objective Pre-operative assessment of mitral valve (MV) anatomy is essential to surgical design in patients undergoing MV repair.Although 2-dimensional (2D) echocardiography provides precise information... Background and objective Pre-operative assessment of mitral valve (MV) anatomy is essential to surgical design in patients undergoing MV repair.Although 2-dimensional (2D) echocardiography provides precise information regarding MV anatomy,RT-3D TEE could increase the understanding of MV apparatus and individual scallop identification.We aimed to investigate the value of RT- 3DTEE in MV repair.Methods RT-3DTEE was performed in six patients with mitral valve prolapse (MVP) by using Philips 1E33 with X7-2t probe.Preoperative RT-3DTEE studies were compared with surgical findings in patients undergoing surgical mitral valve repair,and quantitative evaluation was performed by QLab 6.0 software before and after surgical mitral valve repair.Results RT- 3DTEE could display dynamic morphology of MV,the location of prolapse,and spatial relation to the surrounding tissue.It could provide surgical views of the valves and the valvular apparatus.These results were consistent with surgical findings.The quantitative evaluation before and after surgical MV repair indicated that anterolateral to posteromedial diameter of annulus,anterior to posterior diameter of annulus,perimeter of annulus,and area of annulus in projection plane were significantly smaller after operation compared with those before operation (P【0.05).The length of posterior leaflet,the area of anterior and posterior leaflet,the maximal prolapse height,the volume of leaflet prolapse and the length of coaptation in projection plane were significantly reduced after operation (P【0. 05).Conclusion RT-3DTEE is a unique new modality for rapid and accurate evaluation ofmitral valve prolapse and mitral valve repair. 展开更多
关键词 echocardiography REAL-TIME transeophageal MITRAL VALVE REPAIR
在线阅读 下载PDF
An initial study on left ventricular diastolic function in patients with hypertrophy cardiomyopathy using single-beat, real-time, three-dimensional echocardiography
6
作者 Bei Zhao Juan Li +2 位作者 Yong Xu Hong-Wei Zhu Guang Zhi 《Journal of Geriatric Cardiology》 CAS CSCD 2012年第3期220-227,共8页
Objectives To assess the regional diastolic function in patients with hypertrophic cardiomyopathy (HCM) by using single-beat, real-time, three-dimensional echocardiography (RT-3DE). Methods Sixty-five patients wit... Objectives To assess the regional diastolic function in patients with hypertrophic cardiomyopathy (HCM) by using single-beat, real-time, three-dimensional echocardiography (RT-3DE). Methods Sixty-five patients with HCM in sinus rhythm together with fifty age- and gender-matched normal controls were studied by two dimensional echocardiography (2DE) and RT-3DE. The parameters analyzed by RT-3DE included: left ventrieular (LV) volumes, left ventricular ejection fraction (LVEF), end diastolic sphericity index (EDSI), diastolic dyssynchrony index (DDI), dispersion end diastole (DISPED), and normalized 17 segmental volume-time curves. Results Evaluated by RT-3DE, LVEF was slightly lower compared with 2DE (63.2 ± 6.8% vs. 59.1 ± 6.4%, P 〈 0.0001). Normal subjects had relatively uniform volumetric curves for all LV segments. In HCM patients, the segmental volumetric curves were dyssynchronous. Increased DDI and DISPED in end diastole were observed in patients with HCM (9.95 ± 3.75, 41.76 ± 17.19, P 〈 0.0001), and not all abnormal volumetric segments occurred in the hypertrophic regions. Conclusions Patients with HCM have presented regional diastolic dyssynchrony in the diastole phase, and this preclinical lesion can be recognized by single-beat RT-3DE. 展开更多
关键词 echocardiography Hypertrophic cardiomyopathy Diastolic dyssynchrony
在线阅读 下载PDF
Association between echocardiography utilization and prognosis in patients with cardiac arrest
7
作者 Nan Zhang Qingting Lin Huadong Zhu 《World Journal of Emergency Medicine》 2025年第1期63-66,共4页
Despite efforts to develop treatment technology for cardiac arrest (CA),CA incidence and mortality rates are still high.^([1,2])A recent study of CA patients in emergency departments revealed that the incidence of CA ... Despite efforts to develop treatment technology for cardiac arrest (CA),CA incidence and mortality rates are still high.^([1,2])A recent study of CA patients in emergency departments revealed that the incidence of CA is increasing annually,and the in-hospital survival rate of CA patients is only approximately 28.7%.^([3])Echocardiography has been widely used as an important monitoring tool in critical care and helps to identify the cause of shock,monitor hemodynamics,and guide fluid therapy utilization.^([4])One study reported that approximately one-third of patients underwent formal echocardiography during hospitalization in the intensive care unit (ICU). 展开更多
关键词 PATIENTS echocardiography CARDIAC
在线阅读 下载PDF
Experimental investigation of methane explosion fracturing in bedding shales:Load characteristics and three-dimensional fracture propagation 被引量:1
8
作者 Yu Wang Cheng Zhai +5 位作者 Ting Liu Jizhao Xu Wei Tang Yangfeng Zheng Xinyu Zhu Ning Luo 《International Journal of Mining Science and Technology》 SCIE EI CAS CSCD 2024年第10期1365-1383,共19页
Methane in-situ explosion fracturing(MISEF)enhances permeability in shale reservoirs by detonating desorbed methane to generate detonation waves in perforations.Fracture propagation in bedding shale under varying expl... Methane in-situ explosion fracturing(MISEF)enhances permeability in shale reservoirs by detonating desorbed methane to generate detonation waves in perforations.Fracture propagation in bedding shale under varying explosion loads remains unclear.In this study,prefabricated perforated shale samples with parallel and vertical bedding are fractured under five distinct explosion loads using a MISEF experimental setup.High-frequency explosion pressure-time curves were monitored within an equivalent perforation,and computed tomography scanning along with three-dimensional reconstruction techniques were used to investigate fracture propagation patterns.Additionally,the formation mechanism and influencing factors of explosion crack-generated fines(CGF)were clarified by analyzing the morphology and statistics of explosion debris particles.The results indicate that methane explosion generated oscillating-pulse loads within perforations.Explosion characteristic parameters increase with increasing initial pressure.Explosion load and bedding orientation significantly influence fracture propagation patterns.As initial pressure increases,the fracture mode transitions from bi-wing to 4–5 radial fractures.In parallel bedding shale,radial fractures noticeably deflect along the bedding surface.Vertical bedding facilitates the development of transverse fractures oriented parallel to the cross-section.Bifurcation-merging of explosioninduced fractures generated CGF.CGF mass and fractal dimension increase,while average particle size decreases with increasing explosion load.This study provides valuable insights into MISEF technology. 展开更多
关键词 Methane in-situ explosion fracturing Bedding shale Fracture propagation three-dimensional reconstruction Crack-generated fines Fractal dimension
在线阅读 下载PDF
Development of a toroidal soft x-ray imaging system and application for investigating three-dimensional plasma on J-TEXT
9
作者 赵传旭 李建超 +9 位作者 张晓卿 王能超 丁永华 杨州军 江中和 严伟 李杨波 毛飞越 任正康 the J-TEXT Team 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第3期94-99,共6页
A toroidal soft x-ray imaging(T-SXRI)system has been developed to investigate threedimensional(3D)plasma physics on J-TEXT.This T-SXRI system consists of three sets of SXR arrays.Two sets are newly developed and locat... A toroidal soft x-ray imaging(T-SXRI)system has been developed to investigate threedimensional(3D)plasma physics on J-TEXT.This T-SXRI system consists of three sets of SXR arrays.Two sets are newly developed and located on the vacuum chamber wall at toroidal positionsφof 126.4°and 272.6°,respectively,while one set was established previously atφ=65.50.Each set of SXR arrays consists of three arrays viewing the plasma poloidally,and hence can be used separately to obtain SXR images via the tomographic method.The sawtooth precursor oscillations are measured by T-SXRI,and the corresponding images of perturbative SXR signals are successfully reconstructed at these three toroidal positions,hence providing measurement of the 3D structure of precursor oscillations.The observed 3D structure is consistent with the helical structure of the m/n=1/1 mode.The experimental observation confirms that the T-SXRI system is able to observe 3D structures in the J-TEXT plasma. 展开更多
关键词 SXR imaging J-TEXT tokamak three-dimensional measurement MHD
在线阅读 下载PDF
Study of three-dimensional spatial diffuse discharge in contact electrode structure applied to air purification
10
作者 Shuai XU Wenzheng LIU +3 位作者 Jiaying QIN Yiwei SUN Xitao JIANG Qi QI 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第10期73-81,共9页
In this work,based on the role of pre-ionization of the non-uniform electric field and its effect of reducing the collisional ionization coefficient,a diffuse dielectric barrier discharge plasma is formed in the open ... In this work,based on the role of pre-ionization of the non-uniform electric field and its effect of reducing the collisional ionization coefficient,a diffuse dielectric barrier discharge plasma is formed in the open space outside the electrode structure at a lower voltage by constructing a three-dimensional non-uniform spatial electric field using a contact electrode structure.The air purification study is also carried out.Firstly,a contact electrode structure is constructed using a three-dimensional wire electrode.The distribution characteristics of the spatial electric field formed by this electrode structure are analyzed,and the effects of the non-uniform electric field and the different angles of the vertical wire on the generation of three-dimensional spatial diffuse discharge are investigated.Secondly,the copper foam contact electrode structure is constructed using copper foam material,and the effects of different mesh sizes on the electric field distribution are analyzed.The results show that as the mesh size of the copper foam becomes larger,a strong electric field region exists not only on the surface of the insulating layer,but also on the surface of the vertical wires inside the copper foam,i.e.,the strong electric field region shows a three-dimensional distribution.Besides,as the mesh size increases,the area of the vertical strong electric field also increases.However,the electric field strength on the surface of the insulating layer gradually decreases.Therefore,the appropriate mesh size can effectively increase the discharge area,which is conducive to improving the air purification efficiency.Finally,a highly permeable stacked electrode structure of multilayer wire-copper foam is designed.In combination with an ozone treatment catalyst,an air purification device is fabricated,and the air purification experiment is carried out. 展开更多
关键词 dielectric barrier discharge three-dimensional spatial discharge atmospheric pressure air diffusion discharge air purification
在线阅读 下载PDF
Centers and Limit Cycles for a Class of Three-dimensional Cubic Kukles Systems
11
作者 Liang Kunjian Huang Zhanghan Huang Wentao 《数学理论与应用》 2024年第4期31-44,共14页
In this paper the centers and limit cycles for a class of three-dimensional cubic Kukles systems are investigated.First,by calculating and analyzing the common zeros of the first ten singular point quantities,the nece... In this paper the centers and limit cycles for a class of three-dimensional cubic Kukles systems are investigated.First,by calculating and analyzing the common zeros of the first ten singular point quantities,the necessary conditions for the origin being a center on the center manifold are derived,and furthermore,the sufficiency of those conditions is proved using the Darboux integrating method.Then,by calculating and analyzing the common zeros of the first three period constants,the necessary and sufficient conditions for the origin being an isochronous center on the center manifold are given.Finally,by proving the linear independence of the first ten singular point quantities,it is demonstrated that the system can bifurcate ten small-amplitude limit cycles near the origin under a suitable perturbation,which is a new lower bound for the number of limit cycles around a weak focus in a three-dimensional cubic system. 展开更多
关键词 three-dimensional Kukles system Singular point quantity Limit cycle Center Darboux integrating method
在线阅读 下载PDF
A contrastive study on the influences of radial and three-dimensional satellite gravity gradiometry on the accuracy of the Earth's gravitational field recovery 被引量:5
12
作者 郑伟 许厚泽 +1 位作者 钟敏 员美娟 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第10期577-584,共8页
The accuracy of the Earth's gravitational field measured from the gravity field and steady-state ocean circulation explorer(GOCE),up to 250 degrees,influenced by the radial gravity gradient V zz and three-dimension... The accuracy of the Earth's gravitational field measured from the gravity field and steady-state ocean circulation explorer(GOCE),up to 250 degrees,influenced by the radial gravity gradient V zz and three-dimensional gravity gradient V ij from the satellite gravity gradiometry(SGG) are contrastively demonstrated based on the analytical error model and numerical simulation,respectively.Firstly,the new analytical error model of the cumulative geoid height,influenced by the radial gravity gradient V zz and three-dimensional gravity gradient V ij are established,respectively.In 250 degrees,the GOCE cumulative geoid height error measured by the radial gravity gradient V zz is about 2 1/2 times higher than that measured by the three-dimensional gravity gradient V ij.Secondly,the Earth's gravitational field from GOCE completely up to 250 degrees is recovered using the radial gravity gradient V zz and three-dimensional gravity gradient V ij by numerical simulation,respectively.The study results show that when the measurement error of the gravity gradient is 3×10 12 /s 2,the cumulative geoid height errors using the radial gravity gradient V zz and three-dimensional gravity gradient V ij are 12.319 cm and 9.295 cm at 250 degrees,respectively.The accuracy of the cumulative geoid height using the three-dimensional gravity gradient V ij is improved by 30%-40% on average compared with that using the radial gravity gradient V zz in 250 degrees.Finally,by mutual verification of the analytical error model and numerical simulation,the orders of magnitude from the accuracies of the Earth's gravitational field recovery make no substantial differences based on the radial and three-dimensional gravity gradients,respectively.Therefore,it is feasible to develop in advance a radial cold-atom interferometric gradiometer with a measurement accuracy of 10 13 /s 2-10 15 /s 2 for precisely producing the next-generation GOCE Follow-On Earth gravity field model with a high spatial resolution. 展开更多
关键词 GOCE GOCE Follow-On radial and three-dimensional gravity gradients satellite gravity gradiometry Earth's gravitational field
在线阅读 下载PDF
Terahertz Three-Dimensional Imaging Based on Computed Tomography with Photonics-Based Noise Source 被引量:4
13
作者 周涛 张戎 +3 位作者 姚辰 符张龙 邵棣祥 曹俊诚 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第8期76-78,共3页
Computed tomography has been proven to be useful for non-destructive inspection of structures and materials. We build a three-dimensional imaging system with the photonically generated incoherent noise source and the ... Computed tomography has been proven to be useful for non-destructive inspection of structures and materials. We build a three-dimensional imaging system with the photonically generated incoherent noise source and the Schottky barrier diode detector in the terahertz frequency band (90–140GHz). Based on the computed tomography technique, the three-dimensional image of a ceramic sample is reconstructed successfully by stacking the slices at different heights. The imaging results not only indicate the ability of terahertz wave in the non-invasive sensing and non-destructive inspection applications, but also prove the effectiveness and superiority of the uni-traveling-carrier photodiode as a terahertz source in the imaging applications. 展开更多
关键词 THz Terahertz three-dimensional Imaging Based on Computed Tomography with Photonics-Based Noise Source
在线阅读 下载PDF
Optical encryption of multiple three-dimensional objects based on multiple interferences and single-pixel digital holography 被引量:2
14
作者 Ying Wang Qi Liu +1 位作者 Jun Wang Qiong-Hua Wang 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第3期253-259,共7页
We present an optical encryption method of multiple three-dimensional objects based on multiple interferences and single-pixel digital holography. By modifying the Mach-Zehnder interferometer, the interference of the ... We present an optical encryption method of multiple three-dimensional objects based on multiple interferences and single-pixel digital holography. By modifying the Mach-Zehnder interferometer, the interference of the multiple objects beams and the one reference beam is used to simultaneously encrypt multiple objects into a ciphertext. During decryption, each three-dimensional object can be decrypted independently without having to decrypt other objects. Since the single- pixel digital holography based on compressive sensing theory is introduced, the encrypted data of this method is effectively reduced. In addition, recording fewer encrypted data can greatly reduce the bandwidth of network transmission. Moreover, the compressive sensing essentially serves as a secret key that makes an intruder attack invalid, which means that the system is more secure than the conventional encryption method. Simulation results demonstrate the feasibility of the proposed method and show that the system has good security performance. 展开更多
关键词 multiple three-dimensional objects encryption single-pixel digital holography phase-shifting in- terference compressive sensing
在线阅读 下载PDF
Near-Range Large Field-of-View Three-Dimensional Photon-Counting Imaging with a Single-Pixel Si-Avalanche Photodiode 被引量:3
15
作者 Guang-Yue Shen Tian-Xiang Zheng +4 位作者 Bing-Cheng Du Yang Lv E Wu Zhao-Hui Li Guang Wu 《Chinese Physics Letters》 SCIE CAS CSCD 2018年第11期38-41,共4页
Large field-of-view(FoV) three-dimensional(3 D) photon-counting imaging is demonstrated with a single-pixel single-photon detector based on a Geiger-mode Si-avalanche photodiode. By removing the collecting lens(C... Large field-of-view(FoV) three-dimensional(3 D) photon-counting imaging is demonstrated with a single-pixel single-photon detector based on a Geiger-mode Si-avalanche photodiode. By removing the collecting lens(CL)before the detector, the FoV is expanded to ±10°. Thanks to the high detection efficiency, the signal-to-noise ratio of the imaging system is as high as 7.8 dB even without the CL when the average output laser pulse energy is about 0.45 pJ/pulse for imaging the targets at a distance of 5 m. A 3 D image overlaid with the reflectivity data is obtained according to the photon-counting time-of-flight measurement and the return photon intensity. 展开更多
关键词 Near-Range Large Field-of-View three-dimensional Photon-Counting Imaging with a Single-Pixel Si-Avalanche Photodiode SI
在线阅读 下载PDF
Simulation-Based Construction of Three-Dimensional Process Model for Punching Cartridge Cases 被引量:1
16
作者 Zhifang Wei Yechang Hu +1 位作者 Wu Lyu Jianzhong Gao 《Journal of Beijing Institute of Technology》 EI CAS 2018年第2期276-284,共9页
A method of constructing three-dimensional process model for the punching cartridge cases is presented based on DEFORM simulation analysis. Using DEFORM software,the finite element simulation models for the punching a... A method of constructing three-dimensional process model for the punching cartridge cases is presented based on DEFORM simulation analysis. Using DEFORM software,the finite element simulation models for the punching and forming process of cartridge cases are established,and the corresponding simulation result model of each intermediate procedure is obtained by continuously performing the forming process simulation. The simulation model cannot annotate size and process information due to poor interface between DEFORM software and CAD software. Thus,a 3D annotation module is developed with secondary development technology of UG NX software. Consequently,the final process model with dimension and process information is obtained. Then,with the current 3D process management system,the 3D punching and forming process design of cartridge cases can be completed further. An example is also provided to illustrate that the relative error between the simulation process model and the physical model is less than 2%,which proves the validity and reliability of the proposed method in this study. 展开更多
关键词 punching three-dimensional process model finite element simulation three-dimensional annotation
在线阅读 下载PDF
Giant Asymmetric Transmission and Optical Rotation of a Three-Dimensional Metamaterial 被引量:1
17
作者 黄磊 范云辉 +1 位作者 武山 于立志 《Chinese Physics Letters》 SCIE CAS CSCD 2015年第9期39-42,共4页
We show that giant asymmetric transmission and optical rotation for linear polarizations can be achieved by a chiral three-dimensional metamaterial composed of L-shaped and C-shaped metallic particles. Numerical calcu... We show that giant asymmetric transmission and optical rotation for linear polarizations can be achieved by a chiral three-dimensional metamaterial composed of L-shaped and C-shaped metallic particles. Numerical calcu- lations on the electric field distributions indicate that the coupling between the electric dipolar and quadrupolar resonances in the L- and C-shaped metallic particles contributes to these effects. 展开更多
关键词 Giant Asymmetric Transmission and Optical Rotation of a three-dimensional Metamaterial THZ
在线阅读 下载PDF
An image encryption scheme based on three-dimensional Brownian motion and chaotic system 被引量:6
18
作者 Xiu-Li Chai Zhi-Hua Gan +2 位作者 Ke Yuan l Yang Lu Yi-Ran Chen 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第2期99-113,共15页
At present, many chaos-based image encryption algorithms have proved to be unsafe, few encryption schemes permute the plain images as three-dimensional(3D) bit matrices, and thus bits cannot move to any position, th... At present, many chaos-based image encryption algorithms have proved to be unsafe, few encryption schemes permute the plain images as three-dimensional(3D) bit matrices, and thus bits cannot move to any position, the movement range of bits are limited, and based on them, in this paper we present a novel image encryption algorithm based on 3D Brownian motion and chaotic systems. The architecture of confusion and diffusion is adopted. Firstly, the plain image is converted into a 3D bit matrix and split into sub blocks. Secondly, block confusion based on 3D Brownian motion(BCB3DBM)is proposed to permute the position of the bits within the sub blocks, and the direction of particle movement is generated by logistic-tent system(LTS). Furthermore, block confusion based on position sequence group(BCBPSG) is introduced, a four-order memristive chaotic system is utilized to give random chaotic sequences, and the chaotic sequences are sorted and a position sequence group is chosen based on the plain image, then the sub blocks are confused. The proposed confusion strategy can change the positions of the bits and modify their weights, and effectively improve the statistical performance of the algorithm. Finally, a pixel level confusion is employed to enhance the encryption effect. The initial values and parameters of chaotic systems are produced by the SHA 256 hash function of the plain image. Simulation results and security analyses illustrate that our algorithm has excellent encryption performance in terms of security and speed. 展开更多
关键词 image encryption logistic-tent system(LTS) memristive chaotic system three-dimensional(3D) Brownian motion
在线阅读 下载PDF
Two-dimensional nanosheets as building blocks to construct three-dimensional structures for lithium storage 被引量:1
19
作者 Di Zhang Shuai Wang +1 位作者 Yang Ma Shubin Yang 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2018年第1期128-145,共18页
2D nanosheets such as graphene, silicene, phosphorene, metal dichalcogenides and MXenes are emerging and promising for lithium storage due to their ultrathin nature and corresponding chemical/physical properties. Howe... 2D nanosheets such as graphene, silicene, phosphorene, metal dichalcogenides and MXenes are emerging and promising for lithium storage due to their ultrathin nature and corresponding chemical/physical properties. However, the serious restacking and aggregation of the 2D nanosheets are still hampering their applications. To circumvent the issues of 2D nanosheets, one efficient strategy is to construct 3D structures with hierarchical porous structures, good chemical/mechanical stabilities and tunable electrical conductivities. In this review, we firstly focus on the available synthetic approaches of 3D structures from 2D nanosheets, and then summarize the relationships between the microstructures of 3D structures built from 2D nanosheets and their electrochemical behaviors for lithium storage. On the basis of above results, some challenges are briefly discussed in the perspective of the development of various functional 3D structures. 展开更多
关键词 NanosheetsAtomic layers Graphene three-dimensional structures Lithium ion batteries
在线阅读 下载PDF
An Efficient Three-Dimensional Coupled Normal Mode Model and Its Application to Internal Solitary Wave Problems 被引量:1
20
作者 Ze-Zhong Zhang Wen-Yu Luo Ren-He Zhang 《Chinese Physics Letters》 SCIE CAS CSCD 2018年第8期36-39,共4页
We present an efficient three-dimensional coupled-mode model based on the Fourier synthesis technique. In principle, this model is a one-way model, and hence provides satisfactory accuracy for problems where the forwa... We present an efficient three-dimensional coupled-mode model based on the Fourier synthesis technique. In principle, this model is a one-way model, and hence provides satisfactory accuracy for problems where the forward scattering dominates. At the same time, this model provides an efficiency gain of an order of magnitude or more over two-way coupled-mode models. This model can be applied to three-dimensional range-dependent problems with a slowly varying bathymetry or internal waves. A numerical example of the latter is demonstrated in this work. Comparisons of both accuracy and efficiency between the present model and a benchmark model are also provided. 展开更多
关键词 An Efficient three-dimensional Coupled Normal Mode Model and Its Application to Internal Solitary Wave Problems
在线阅读 下载PDF
上一页 1 2 95 下一页 到第
使用帮助 返回顶部