In the field of deep space exploration,the rapid development of terahertz spectrometer has put forward higher requirements to the back-end chirp transform spectrometer(CTS)system.In order to simultaneously meet the me...In the field of deep space exploration,the rapid development of terahertz spectrometer has put forward higher requirements to the back-end chirp transform spectrometer(CTS)system.In order to simultaneously meet the measurement requirements of wide bandwidth and high accuracy spectral lines,we built a CTS system with an analysis bandwidth of 1 GHz and a frequency resolution of 100 kHz around the surface acoustic wave(SAW)chirp filter with a bandwidth of 1 GHz.In this paper,the relationship between the CTS nonlinear phase error shift model and the basic measurement parameters is studied,and the effect of CTS phase mismatch on the pulse compression waveform is analyzed by simulation.And the expander error optimization method is proposed for the problem that the large nonlinear error of the expander leads to the unbalanced response of the CTS system and the serious distortion of the compressed pulse waveform under large bandwidth.It is verified through simulation and experiment that the method is effective for reducing the root mean square error(RMSE)of the phase of the expander from 18.75°to 6.65°,reducing the in-band standard deviation of the CTS frequency resolution index from 8.43 kHz to 4.72 kHz,solving the problem of serious distortion of the compressed pulse waveform,and improving the uneven CTS response under large bandwidth.展开更多
The miniature design technology is an important trend in space exploration.Mass spectrometer is used extensively in the space environment detection.The miniature ion mass spectrometer utilizes a 127° cylindrical ...The miniature design technology is an important trend in space exploration.Mass spectrometer is used extensively in the space environment detection.The miniature ion mass spectrometer utilizes a 127° cylindrical electrostatic analyzer accompanied with a Time of Flight(TOF)unit based on ultrathin carbon foil to measure the energy spectra and composition of space plasma.The Time of Flight technique has been used broadly in space plasma measurement.A new type of miniature method for the ion mass spectrometer is introduced.The total mass of the instrument is1.8 kg and the total power consumption is 2.0 W.The calibration results show that the energy measurement range is 8.71~43550eV,the energy resolution is 1.86%and the ion mass from 1 amu(1 amu= 1.67 × 10^(-27)kg) to 58 amu can be resolved by the miniature mass spectrometer.The miniature ion mass spectrometer also has a potential to be increased in the field of view by an electrostatic deflecting system to extend its application in space plasma detection.The miniature ion mass spectrometer has been selected for pre-study of Chinese Strategic Priority Research Program on Space Science.展开更多
In order to mitigate the effect of the strong electromagnetic pulse, which produces laser-plasma interactions, we designed a new streaked X-ray spectrometer (SXS) enclosed within a well-sealed, electromag- netic int...In order to mitigate the effect of the strong electromagnetic pulse, which produces laser-plasma interactions, we designed a new streaked X-ray spectrometer (SXS) enclosed within a well-sealed, electromag- netic interference-free cavity. The SXS can cover a wide selection of spectral windows using interchangeable Bragg crystals and by appropriate adjustment of the Bragg angle. The SXS has been used to observe time-re- solved X-ray spectrum in the 2.5 keV to 3.5 keV photon-energy range, resulting in a demonstrated spectral res- olution of about 13 at 2960 eV with a time resolution of 10 ps. The observed time and spectral resolutions dem- onstrate the applicability of the SXS for studies of laser-produced plasmas.展开更多
A novel energy analyzer with a simple structured Bessel box has been successfully developed and incorporated into ionization gauges and quadrupole mass spectrometers (QMS) to improve their measurement of the total and...A novel energy analyzer with a simple structured Bessel box has been successfully developed and incorporated into ionization gauges and quadrupole mass spectrometers (QMS) to improve their measurement of the total and partial pressures,respectively.We found that the energy analyzer may not only effectively separate the gas phase ions and electron stimulated desorption (ESD) ions produced in the ionizer,but also screen the ion collector from irradiation of the soft X rays and VUVphotons generated in the ionizer.The screening effects considerably better the trace impurity detection limit of the QMS down to a few tens ppb in the pressure range of 10 -3 Pa.The modified ionization gauge is capable of measuring pressure ranging from 10 -11 to 10 -6 Pa in the pulse counting mode and its upper limit may extends to 10 -3 Pa in DC ion current mode with typical sensitivities factor of(6.7±0.2)×10 -3 Pa -1 for N 2 and (2.3±0.2)×10 -3 Pa -1 for H 2,respectively.No ESD ions was observed in the simple looking spectrum obtained with the modified QMS.We also found that the energy spectra of fragment ions depend strongly on species of parent ions.展开更多
We present an ultra compact and high resolution free space optical spectrometer and demonstrate it by using FDTD simulations. The miniature interferometer-based spectrometer is a series of submicron phase objects on a...We present an ultra compact and high resolution free space optical spectrometer and demonstrate it by using FDTD simulations. The miniature interferometer-based spectrometer is a series of submicron phase objects on a polymethyl methacrylate(PMMA) film with a CCD as the detector. The spectrum is obtained by solving a system of simultaneous linear equations. The Tikhonov regularization method is used to achieve a resolution at the picometer level. Compared with conventional spectrometers, the proposed device is low-cost and easy to fabricate due to its simple structure. Furthermore, its compact feature renders the device ideal for miniaturization and integration as the systems in microfluidics architectures and lab-on-chip designs.展开更多
文摘In the field of deep space exploration,the rapid development of terahertz spectrometer has put forward higher requirements to the back-end chirp transform spectrometer(CTS)system.In order to simultaneously meet the measurement requirements of wide bandwidth and high accuracy spectral lines,we built a CTS system with an analysis bandwidth of 1 GHz and a frequency resolution of 100 kHz around the surface acoustic wave(SAW)chirp filter with a bandwidth of 1 GHz.In this paper,the relationship between the CTS nonlinear phase error shift model and the basic measurement parameters is studied,and the effect of CTS phase mismatch on the pulse compression waveform is analyzed by simulation.And the expander error optimization method is proposed for the problem that the large nonlinear error of the expander leads to the unbalanced response of the CTS system and the serious distortion of the compressed pulse waveform under large bandwidth.It is verified through simulation and experiment that the method is effective for reducing the root mean square error(RMSE)of the phase of the expander from 18.75°to 6.65°,reducing the in-band standard deviation of the CTS frequency resolution index from 8.43 kHz to 4.72 kHz,solving the problem of serious distortion of the compressed pulse waveform,and improving the uneven CTS response under large bandwidth.
基金Supported by the Strategic Priority Research Program on Space Science,the Chinese Academy of Sciences(XDA04071700,XDA04060202)
文摘The miniature design technology is an important trend in space exploration.Mass spectrometer is used extensively in the space environment detection.The miniature ion mass spectrometer utilizes a 127° cylindrical electrostatic analyzer accompanied with a Time of Flight(TOF)unit based on ultrathin carbon foil to measure the energy spectra and composition of space plasma.The Time of Flight technique has been used broadly in space plasma measurement.A new type of miniature method for the ion mass spectrometer is introduced.The total mass of the instrument is1.8 kg and the total power consumption is 2.0 W.The calibration results show that the energy measurement range is 8.71~43550eV,the energy resolution is 1.86%and the ion mass from 1 amu(1 amu= 1.67 × 10^(-27)kg) to 58 amu can be resolved by the miniature mass spectrometer.The miniature ion mass spectrometer also has a potential to be increased in the field of view by an electrostatic deflecting system to extend its application in space plasma detection.The miniature ion mass spectrometer has been selected for pre-study of Chinese Strategic Priority Research Program on Space Science.
文摘In order to mitigate the effect of the strong electromagnetic pulse, which produces laser-plasma interactions, we designed a new streaked X-ray spectrometer (SXS) enclosed within a well-sealed, electromag- netic interference-free cavity. The SXS can cover a wide selection of spectral windows using interchangeable Bragg crystals and by appropriate adjustment of the Bragg angle. The SXS has been used to observe time-re- solved X-ray spectrum in the 2.5 keV to 3.5 keV photon-energy range, resulting in a demonstrated spectral res- olution of about 13 at 2960 eV with a time resolution of 10 ps. The observed time and spectral resolutions dem- onstrate the applicability of the SXS for studies of laser-produced plasmas.
文摘A novel energy analyzer with a simple structured Bessel box has been successfully developed and incorporated into ionization gauges and quadrupole mass spectrometers (QMS) to improve their measurement of the total and partial pressures,respectively.We found that the energy analyzer may not only effectively separate the gas phase ions and electron stimulated desorption (ESD) ions produced in the ionizer,but also screen the ion collector from irradiation of the soft X rays and VUVphotons generated in the ionizer.The screening effects considerably better the trace impurity detection limit of the QMS down to a few tens ppb in the pressure range of 10 -3 Pa.The modified ionization gauge is capable of measuring pressure ranging from 10 -11 to 10 -6 Pa in the pulse counting mode and its upper limit may extends to 10 -3 Pa in DC ion current mode with typical sensitivities factor of(6.7±0.2)×10 -3 Pa -1 for N 2 and (2.3±0.2)×10 -3 Pa -1 for H 2,respectively.No ESD ions was observed in the simple looking spectrum obtained with the modified QMS.We also found that the energy spectra of fragment ions depend strongly on species of parent ions.
基金supported by the Hong Kong Research Grants Council under CERG project 411907 and 412208Nation-al Basic Research Program of China(973)(No.2009CB930600)
文摘We present an ultra compact and high resolution free space optical spectrometer and demonstrate it by using FDTD simulations. The miniature interferometer-based spectrometer is a series of submicron phase objects on a polymethyl methacrylate(PMMA) film with a CCD as the detector. The spectrum is obtained by solving a system of simultaneous linear equations. The Tikhonov regularization method is used to achieve a resolution at the picometer level. Compared with conventional spectrometers, the proposed device is low-cost and easy to fabricate due to its simple structure. Furthermore, its compact feature renders the device ideal for miniaturization and integration as the systems in microfluidics architectures and lab-on-chip designs.