目的探讨5F鞘组在经外周静脉穿刺置入中心静脉导管(peripherally inserted central catheter,PICC)中临床应用的效果。方法回顾性分析并总结2012年12月至2013年2月哈尔滨医科大学附属第一医院收治的应用5F鞘组10例行PICC患者的临床资料...目的探讨5F鞘组在经外周静脉穿刺置入中心静脉导管(peripherally inserted central catheter,PICC)中临床应用的效果。方法回顾性分析并总结2012年12月至2013年2月哈尔滨医科大学附属第一医院收治的应用5F鞘组10例行PICC患者的临床资料。结果 10例患者均顺利完成PICC,有2例患者术后出现静脉炎,其余患者均未发生严重的并发症。结论静脉穿刺条件差的患者应用5F鞘组行PICC导管有利于提高置管成功率。展开更多
Thermogravimetric study of rubber compositions (operating glove and catheter) in medical waste was carried out using the thermogravimetric analyser (TGA),at the heating rate of 20 ℃/min in a stream of N2.The resu...Thermogravimetric study of rubber compositions (operating glove and catheter) in medical waste was carried out using the thermogravimetric analyser (TGA),at the heating rate of 20 ℃/min in a stream of N2.The results indicate that the decomposition process of operating glove appears an obvious mass loss stage at 250-485 ℃,while catheter has two obvious stages at 240-510 ℃ and 655-800 ℃,respectively; both samples present endothermic pyrolysis reaction; the decomposition of operating glove and the first mass loss stage of catheter are in agreement with natural rubber pyrolysis; the second mass loss stage of catheter corresponds to CaCO3 decomposition.Based on the experimental results,a novel two-step four-reaction model was established to simulate the whole continuous processes,which could more satisfactorily describe and predict the pyrolysis processes of rubber compositions,being more mechanistic and conveniently serving for the engineering.展开更多
Thermal decomposition of 21 kinds of binary mixtures between typical medical compositions was investigated under nitrogen conditions by dynamic thermogravimetric analysis(TGA) at 25–800 °C. The weighed sum metho...Thermal decomposition of 21 kinds of binary mixtures between typical medical compositions was investigated under nitrogen conditions by dynamic thermogravimetric analysis(TGA) at 25–800 °C. The weighed sum method(WSM) coupled with thermal analysis was applied to study the interaction between components. Then, co-pyrolysis kinetic model of the binary mixtures(tube for transfusion(TFT) and gauze) was established to verify the reliability of conclusions. The results show the follows. 1) Strong or weak interactions are shown between binary mixtures containing polyvinyl chloride(PVC), the main ingredient of TFT. The addition of other medical waste could enhance first stage decomposition of TFT. While, the secondary stage pyrolysis may be suppressed or enhanced or not affected by the addition. 2) There exists no interaction between catheter and other component, the DTG peak temperature representing Ca CO3 decomposition in catheter fraction is obviously lower than that of pure catheter; while,the shape of DTG peak keeps unchanged. 3) No evident reaction occurs between the other mix-samples, it is considered that their co-pyrolysis characteristics are linear superposition of mono-component pyrolysis characteristics.展开更多
文摘目的探讨5F鞘组在经外周静脉穿刺置入中心静脉导管(peripherally inserted central catheter,PICC)中临床应用的效果。方法回顾性分析并总结2012年12月至2013年2月哈尔滨医科大学附属第一医院收治的应用5F鞘组10例行PICC患者的临床资料。结果 10例患者均顺利完成PICC,有2例患者术后出现静脉炎,其余患者均未发生严重的并发症。结论静脉穿刺条件差的患者应用5F鞘组行PICC导管有利于提高置管成功率。
基金Project(50378062)supported by the National Natural Science Foundation of ChinaProject(09JCYBJC08100)supported by the Natural Science Foundation of Tianjin Municipality,ChinaProject supported by Key Laboratory Program of the Ministry of Education,China
文摘Thermogravimetric study of rubber compositions (operating glove and catheter) in medical waste was carried out using the thermogravimetric analyser (TGA),at the heating rate of 20 ℃/min in a stream of N2.The results indicate that the decomposition process of operating glove appears an obvious mass loss stage at 250-485 ℃,while catheter has two obvious stages at 240-510 ℃ and 655-800 ℃,respectively; both samples present endothermic pyrolysis reaction; the decomposition of operating glove and the first mass loss stage of catheter are in agreement with natural rubber pyrolysis; the second mass loss stage of catheter corresponds to CaCO3 decomposition.Based on the experimental results,a novel two-step four-reaction model was established to simulate the whole continuous processes,which could more satisfactorily describe and predict the pyrolysis processes of rubber compositions,being more mechanistic and conveniently serving for the engineering.
基金Projects(51105269,51406133)supported by the National Natural Science Foundation of ChinaProject supported by the ScientificResearch Foundation for the Returned Overseas Chinese Scholars,Ministry of Education,ChinaProject supported by the Ministry ofEducation Key Laboratory Program,China
文摘Thermal decomposition of 21 kinds of binary mixtures between typical medical compositions was investigated under nitrogen conditions by dynamic thermogravimetric analysis(TGA) at 25–800 °C. The weighed sum method(WSM) coupled with thermal analysis was applied to study the interaction between components. Then, co-pyrolysis kinetic model of the binary mixtures(tube for transfusion(TFT) and gauze) was established to verify the reliability of conclusions. The results show the follows. 1) Strong or weak interactions are shown between binary mixtures containing polyvinyl chloride(PVC), the main ingredient of TFT. The addition of other medical waste could enhance first stage decomposition of TFT. While, the secondary stage pyrolysis may be suppressed or enhanced or not affected by the addition. 2) There exists no interaction between catheter and other component, the DTG peak temperature representing Ca CO3 decomposition in catheter fraction is obviously lower than that of pure catheter; while,the shape of DTG peak keeps unchanged. 3) No evident reaction occurs between the other mix-samples, it is considered that their co-pyrolysis characteristics are linear superposition of mono-component pyrolysis characteristics.