In order to get rid of the dependence on high-precision centrifuges in accelerometer nonlinear coefficients calibration,this paper proposes a system-level calibration method for field condition.Firstly,a 42-dimension ...In order to get rid of the dependence on high-precision centrifuges in accelerometer nonlinear coefficients calibration,this paper proposes a system-level calibration method for field condition.Firstly,a 42-dimension Kalman filter is constructed to reduce impact brought by turntable.Then,a biaxial rotation path is designed based on the accelerometer output model,including orthogonal 22 positions and tilt 12 positions,which enhances gravity excitation on nonlinear coefficients of accelerometer.Finally,sampling is carried out for calibration and further experiments.The results of static inertial navigation experiments lasting 4000 s show that compared with the traditional method,the proposed method reduces the position error by about 390 m.展开更多
To enhance direction of arrival(DOA)estimation accuracy,this paper proposes a low-cost method for calibrating farfield steering vectors of large aperture millimeter wave radar(mmWR).To this end,we first derive the ste...To enhance direction of arrival(DOA)estimation accuracy,this paper proposes a low-cost method for calibrating farfield steering vectors of large aperture millimeter wave radar(mmWR).To this end,we first derive the steering vectors with amplitude and phase errors,assuming that mmWR works in the time-sharing mode.Then,approximate relationship between the near-field calibration steering vector and the far-field calibration steering vector is analyzed,which is used to accomplish the mapping between the two of them.Finally,simulation results verify that the proposed method can effectively improve the angle measurement accuracy of mmWR with existing amplitude and phase errors.展开更多
Metal Additive Manufacturing(MAM) technology has become an important means of rapid prototyping precision manufacturing of special high dynamic heterogeneous complex parts. In response to the micromechanical defects s...Metal Additive Manufacturing(MAM) technology has become an important means of rapid prototyping precision manufacturing of special high dynamic heterogeneous complex parts. In response to the micromechanical defects such as porosity issues, significant deformation, surface cracks, and challenging control of surface morphology encountered during the selective laser melting(SLM) additive manufacturing(AM) process of specialized Micro Electromechanical System(MEMS) components, multiparameter optimization and micro powder melt pool/macro-scale mechanical properties control simulation of specialized components are conducted. The optimal parameters obtained through highprecision preparation and machining of components and static/high dynamic verification are: laser power of 110 W, laser speed of 600 mm/s, laser diameter of 75 μm, and scanning spacing of 50 μm. The density of the subordinate components under this reference can reach 99.15%, the surface hardness can reach 51.9 HRA, the yield strength can reach 550 MPa, the maximum machining error of the components is 4.73%, and the average surface roughness is 0.45 μm. Through dynamic hammering and high dynamic firing verification, SLM components meet the requirements for overload resistance. The results have proven that MEM technology can provide a new means for the processing of MEMS components applied in high dynamic environments. The parameters obtained in the conclusion can provide a design basis for the additive preparation of MEMS components.展开更多
This study presents a kinematic calibration method for exoskeletal inertial motion capture (EI-MoCap) system with considering the random colored noise such as gyroscopic drift.In this method, the geometric parameters ...This study presents a kinematic calibration method for exoskeletal inertial motion capture (EI-MoCap) system with considering the random colored noise such as gyroscopic drift.In this method, the geometric parameters are calibrated by the traditional calibration method at first. Then, in order to calibrate the parameters affected by the random colored noise, the expectation maximization (EM) algorithm is introduced. Through the use of geometric parameters calibrated by the traditional calibration method, the iterations under the EM framework are decreased and the efficiency of the proposed method on embedded system is improved. The performance of the proposed kinematic calibration method is compared to the traditional calibration method. Furthermore, the feasibility of the proposed method is verified on the EI-MoCap system. The simulation and experiment demonstrate that the motion capture precision is significantly improved by 16.79%and 7.16%respectively in comparison to the traditional calibration method.展开更多
There are many motors in operation or on standby in nuclear power plants,and the startup of group motors will have a great impact on the voltage of the emergency bus.At present,there is no special or inexpensive softw...There are many motors in operation or on standby in nuclear power plants,and the startup of group motors will have a great impact on the voltage of the emergency bus.At present,there is no special or inexpensive software to solve this problem,and the experience of engineers is not accurate enough.Therefore,this paper developed a method and system for the startup calculation of group motors in nuclear power plants and proposed an automatic generation method of circuit topology in nuclear power plants.Each component in the topology was given its unique number,and the component class could be constructed according to its type and upper and lower connections.The subordination and topology relationship of switches,buses,and motors could be quickly generated by the program according to the component class,and the simplified direct power flow algorithm was used to calculate the power flow for the startup of group motors according to the above relationship.Then,whether the bus voltage is in the safe range and whether the voltage exceeds the limit during the startup of the group motor could be judged.The practical example was used to verify the effectiveness of the method.Compared with other professional software,the method has high efficiency and low cost.展开更多
The mathematical model used to describe the detonation multi-physics phenomenon is usually given by highly coupled nonlinear partial differential equations. Numerical simulation and the computer aided engineering (CAE...The mathematical model used to describe the detonation multi-physics phenomenon is usually given by highly coupled nonlinear partial differential equations. Numerical simulation and the computer aided engineering (CAE) technique has become the third pillar of detonation research, along with theory and experiment, due to the detonation phenomenon is difficult to explain by the theoretical analysis, and the cost required to accredit the reliability of detonation products is very high, even some physical experiments of detonation are impossible. The numerical simulation technique can solve these complex problems in the real situation repeatedly and reduce the design cost and time stunningly. But the reliability of numerical simulation software and the serviceability of the computational result seriously hinders the extension, application and the self-restoration of the simulation software, restricts its independently innovational ability. This article deals with the physical modeling, numerical simulation, and software development of detonation in a unified way. Verification and validation and uncertainty quantification (V&V&UQ) is an important approach in ensuring the credibility of the modeling and simulation of detonation. V&V of detonation is based on our independently developed detonation multiphysics software-LAD2D. We propose the verification method based on mathematical theory and program function as well as availability of its program execution. Validation is executed by comparing with the experiment data. At last, we propose the future prospect of numerical simulation software and the CAE technique, and we also pay attention to the research direction of V&V&UQ.展开更多
As a powerful distributed data processing mechanism,MapReduce supports abundant parallel applications that process massive data on computer clusters.To process the massive data efficiently and correctly,a rational des...As a powerful distributed data processing mechanism,MapReduce supports abundant parallel applications that process massive data on computer clusters.To process the massive data efficiently and correctly,a rational design for the MapReduce procedure is desired.An irrational MapReduce procedure can cause great waste of computing resources and even paralyze the execution system.With the wide application of MapReduce,the unavoidable drawback of irrational MapReduce procedures becomes increasingly serious.To solve this problem,a method for verifying the rationality of a MapReduce procedure before executing it on a computer cluster is proposed.This method constructs the rationality criteria for MapReduce,and then studies an automatic approach for modelling MapReduce with an executable model object Petri net(OPN).Finally,the approaches for automatically identifying the rationality criteria by analyzing the consequence of model execution is developed.The results from extensive case studies demonstrate that the proposed method is feasible and effective.展开更多
In order to achieve a high precision in three-dimensional(3D) multi-camera measurement system, an efficient multi-cameracalibration method is proposed. A stitching method of large scalecalibration targets is deduced...In order to achieve a high precision in three-dimensional(3D) multi-camera measurement system, an efficient multi-cameracalibration method is proposed. A stitching method of large scalecalibration targets is deduced, and a fundamental of multi-cameracalibration based on the large scale calibration target is provided.To avoid the shortcomings of the method, the vector differencesof reprojection error with the presence of the constraint conditionof the constant rigid body transformation is modelled, and mini-mized by the Levenberg-Marquardt (LM) method. Results of thesimulation and observation data calibration experiment show thatthe accuracy of the system calibrated by the proposed methodreaches 2 mm when measuring distance section of 20 000 mmand scale section of 7 000 mm × 7 000 mm. Consequently, theproposed method of multi-camera calibration performs better thanthe fundamental in stability. This technique offers a more uniformerror distribution for measuring large scale space.展开更多
In order to deal with the limitations during the register transfer level verification, a new functional verification method based on the random testing for the system-level of system-on-chip is proposed.The validity o...In order to deal with the limitations during the register transfer level verification, a new functional verification method based on the random testing for the system-level of system-on-chip is proposed.The validity of this method is proven theoretically.Specifically, testcases are generated according to many approaches of randomization.Moreover, the testbench for the system-level verification according to the proposed method is designed by using advanced modeling language.Therefore, under the circumstances that the testbench generates testcases quickly, the hardware/software co-simulation and co-verification can be implemented and the hardware/software partitioning planning can be evaluated easily.The comparison method is put to use in the evaluation approach of the testing validity.The evaluation result indicates that the efficiency of the partition testing is better than that of the random testing only when one or more subdomains are covered over with the area of errors, although the efficiency of the random testing is generally better than that of the partition testing.The experimental result indicates that this method has a good performance in the functional coverage and the cost of testing and can discover the functional errors as soon as possible.展开更多
The exact radar cross-section (RCS) measurement is difficult when the scattering of targets is low. Ful polarimetric cali-bration is one technique that offers the potential for improving the accuracy of RCS measurem...The exact radar cross-section (RCS) measurement is difficult when the scattering of targets is low. Ful polarimetric cali-bration is one technique that offers the potential for improving the accuracy of RCS measurements. There are numerous polarimetric calibration algorithms. Some complex expressions in these algo-rithms cannot be easily used in an engineering practice. A radar polarimetric coefficients matrix (RPCM) with a simpler expression is presented for the monostatic radar polarization scattering matrix (PSM) measurement. Using a rhombic dihedral corner reflector and a metal ic sphere, the RPCM can be obtained by solving a set of equations, which can be used to find the true PSM for any target. An example for the PSM of a metal ic dish shows that the proposed method obviously improves the accuracy of cross-polarized RCS measurements.展开更多
Two dynamic grey models DGM (1, 1) for the verification cycle and the lifecycle of measuring instrument based on time sequence and frequency sequence were set up, according to the statistical feature of examination da...Two dynamic grey models DGM (1, 1) for the verification cycle and the lifecycle of measuring instrument based on time sequence and frequency sequence were set up, according to the statistical feature of examination data and weighting method. By a specific case, i.e. vernier caliper, it is proved that the fit precision and forecast precision of the models are much higher, the cycles are obviously different under different working conditions, and the forecast result of the frequency sequence model is better than that of the time sequence model. Combining dynamic grey model and auto-manufacturing case the controlling and information subsystems of verification cycle and the lifecycle based on information integration, multi-sensor controlling and management controlling were given. The models can be used in production process to help enterprise reduce error, cost and flaw.展开更多
A novel polarimetric calibration method for new target property measurement radar system is presented. Its applica- tion in the real radar system is also discussed. The analysis indicates that instantaneous polarizati...A novel polarimetric calibration method for new target property measurement radar system is presented. Its applica- tion in the real radar system is also discussed. The analysis indicates that instantaneous polarization radar ([PR) has inherent cross-polarization measurement error. The proposed method can effectively eliminate this error, and thus enhance the polarization scattering matrix (PSM) measurement precision. The phase error caused by digital receiver's direct IF sampling and mixing of two orthogonal polarization channels can be removed. Consequently, the inherent error of target polarization scattering measurement of the instantaneous polarization radar system is well revised. It has good reference value for further ploarimetric calibration and high practical application prospect.展开更多
The blackbody calibration targets applied for microwave radiometer's prelaunch calibration are optimized with its electromagnetic and thermal characteristics. Based on the method of emissivity optimization with radar...The blackbody calibration targets applied for microwave radiometer's prelaunch calibration are optimized with its electromagnetic and thermal characteristics. Based on the method of emissivity optimization with radar cross section (RCS) simulation and the method of subgrid finite difference time domain (FDTD), the following design rules are summarized: that the round wedge is better than the square one, the best ratio from height to bottom radius is 4:1, for wide band calibration, the multilayer absorbing material coating is efficient to increase the emissivity, and the gradual thickness absorbing material coating is helpful to guarantee the uniform distribution of surface temperature even as it keeps a higher emissivity. Finally following the above conclusions, a new type of blackbody calibration target with the cellular array is preferred to improve the uniformity of polarization, which will increase the performance of the calibration targets further.展开更多
A new method for array calibration of array gain and phase uncertainties, which severely degrade the performance of spatial spectrum estimation, is presented. The method is based on the idea of the instrumental sensor...A new method for array calibration of array gain and phase uncertainties, which severely degrade the performance of spatial spectrum estimation, is presented. The method is based on the idea of the instrumental sensors method (ISM), two well-calibrated sensors are added into the original array. By applying the principle of estimation of signal parameters via rotational invariance techniques (ESPRIT), the direction-of-arrivals (DOAs) and uncertainties can be estimated simultaneously through eigen-decomposition. Compared with the conventional ones, this new method has less computational complexity while has higher estimation precision, what's more, it can overcome the problem of ambiguity. Both theoretical analysis and computer simulations show the effectiveness of the proposed method.展开更多
Driving safety field(DSF) model has been proposed to represent comprehensive driving risk formed by interactions of driver-vehicle-road in mixed traffic environment. In this work, we establish an optimization model ba...Driving safety field(DSF) model has been proposed to represent comprehensive driving risk formed by interactions of driver-vehicle-road in mixed traffic environment. In this work, we establish an optimization model based on grey relation degree analysis to calibrate risk coefficients of DSF model. To solve the optimum solution, a genetic algorithm is employed. Finally, the DSF model is verified through a real-world driving experiment. Results show that the DSF model is consistent with driver's hazard perception and more sensitive than TTC. Moreover, the proposed DSF model offers a novel way for criticality assessment and decision-making of advanced driver assistance systems and intelligent connected vehicles.展开更多
The development processes and the application achievements of space-borne microwave sounder pre-launch calibration technologies in China are introduced briefly. Then, the general project plan for pre-launch calibratio...The development processes and the application achievements of space-borne microwave sounder pre-launch calibration technologies in China are introduced briefly. Then, the general project plan for pre-launch calibration, the latest research achievements on the optimization and development of the microwave wide band calibration targets, emissivity measurement technologies and the system level uncertainty analysis of the laboratory, and the thermal/vacuum microwave sounder calibration system for "FY-3" meteorological satellite are reported, respectively. Finally, the key technological problems of the calibration technologies under researching are analyzed predictively.展开更多
An optimal measurement pose number searching method was designed to improve the pose selection method.Several optimal robot measurement configurations were added to an initial pre-selected optimal configuration set to...An optimal measurement pose number searching method was designed to improve the pose selection method.Several optimal robot measurement configurations were added to an initial pre-selected optimal configuration set to establish a new configuration set for robot calibration one by one.The root mean squares (RMS) of the errors of each end-effector poses after being calibrated by these configuration sets were calculated.The optimal number of the configuration set corresponding to the least RMS of pose error was then obtained.Calibration based on those poses selected by this algorithm can get higher end-effector accuracy,meanwhile consumes less time.An optimal pose set including optimal 25 measurement configurations is found during the simulation.Tracking errors after calibration by using these poses are 1.54,1.61 and 0.86 mm,and better than those before calibration which are 7.79,7.62 and 8.29 mm,even better than those calibrated by the random method which are 2.22,2.35 and 1.69 mm in directions X,Y and Z,respectively.展开更多
基金supported by the National Natural Science Foundation of China(42276199).
文摘In order to get rid of the dependence on high-precision centrifuges in accelerometer nonlinear coefficients calibration,this paper proposes a system-level calibration method for field condition.Firstly,a 42-dimension Kalman filter is constructed to reduce impact brought by turntable.Then,a biaxial rotation path is designed based on the accelerometer output model,including orthogonal 22 positions and tilt 12 positions,which enhances gravity excitation on nonlinear coefficients of accelerometer.Finally,sampling is carried out for calibration and further experiments.The results of static inertial navigation experiments lasting 4000 s show that compared with the traditional method,the proposed method reduces the position error by about 390 m.
文摘To enhance direction of arrival(DOA)estimation accuracy,this paper proposes a low-cost method for calibrating farfield steering vectors of large aperture millimeter wave radar(mmWR).To this end,we first derive the steering vectors with amplitude and phase errors,assuming that mmWR works in the time-sharing mode.Then,approximate relationship between the near-field calibration steering vector and the far-field calibration steering vector is analyzed,which is used to accomplish the mapping between the two of them.Finally,simulation results verify that the proposed method can effectively improve the angle measurement accuracy of mmWR with existing amplitude and phase errors.
基金funded by the National Natural Science Foundation of China Youth Fund(Grant No.62304022)Science and Technology on Electromechanical Dynamic Control Laboratory(China,Grant No.6142601012304)the 2022e2024 China Association for Science and Technology Innovation Integration Association Youth Talent Support Project(Grant No.2022QNRC001).
文摘Metal Additive Manufacturing(MAM) technology has become an important means of rapid prototyping precision manufacturing of special high dynamic heterogeneous complex parts. In response to the micromechanical defects such as porosity issues, significant deformation, surface cracks, and challenging control of surface morphology encountered during the selective laser melting(SLM) additive manufacturing(AM) process of specialized Micro Electromechanical System(MEMS) components, multiparameter optimization and micro powder melt pool/macro-scale mechanical properties control simulation of specialized components are conducted. The optimal parameters obtained through highprecision preparation and machining of components and static/high dynamic verification are: laser power of 110 W, laser speed of 600 mm/s, laser diameter of 75 μm, and scanning spacing of 50 μm. The density of the subordinate components under this reference can reach 99.15%, the surface hardness can reach 51.9 HRA, the yield strength can reach 550 MPa, the maximum machining error of the components is 4.73%, and the average surface roughness is 0.45 μm. Through dynamic hammering and high dynamic firing verification, SLM components meet the requirements for overload resistance. The results have proven that MEM technology can provide a new means for the processing of MEMS components applied in high dynamic environments. The parameters obtained in the conclusion can provide a design basis for the additive preparation of MEMS components.
基金supported by the National Natural Science Foundation of China (61503392)。
文摘This study presents a kinematic calibration method for exoskeletal inertial motion capture (EI-MoCap) system with considering the random colored noise such as gyroscopic drift.In this method, the geometric parameters are calibrated by the traditional calibration method at first. Then, in order to calibrate the parameters affected by the random colored noise, the expectation maximization (EM) algorithm is introduced. Through the use of geometric parameters calibrated by the traditional calibration method, the iterations under the EM framework are decreased and the efficiency of the proposed method on embedded system is improved. The performance of the proposed kinematic calibration method is compared to the traditional calibration method. Furthermore, the feasibility of the proposed method is verified on the EI-MoCap system. The simulation and experiment demonstrate that the motion capture precision is significantly improved by 16.79%and 7.16%respectively in comparison to the traditional calibration method.
基金Key Project of National Natural Science Foundation of China(52237008)Beijing Municipal Education Commission Research Program Funding Project(KM202111232022)。
文摘There are many motors in operation or on standby in nuclear power plants,and the startup of group motors will have a great impact on the voltage of the emergency bus.At present,there is no special or inexpensive software to solve this problem,and the experience of engineers is not accurate enough.Therefore,this paper developed a method and system for the startup calculation of group motors in nuclear power plants and proposed an automatic generation method of circuit topology in nuclear power plants.Each component in the topology was given its unique number,and the component class could be constructed according to its type and upper and lower connections.The subordination and topology relationship of switches,buses,and motors could be quickly generated by the program according to the component class,and the simplified direct power flow algorithm was used to calculate the power flow for the startup of group motors according to the above relationship.Then,whether the bus voltage is in the safe range and whether the voltage exceeds the limit during the startup of the group motor could be judged.The practical example was used to verify the effectiveness of the method.Compared with other professional software,the method has high efficiency and low cost.
基金supported by Science Challenge Project [No TZ2018001]Shandong Provincial Natural Science Foundation [No ZR2017BA014]+1 种基金National Natural Science Foundation of China [No91630312]the Development Program for Defense Ministry of China [No.C1520110002]
文摘The mathematical model used to describe the detonation multi-physics phenomenon is usually given by highly coupled nonlinear partial differential equations. Numerical simulation and the computer aided engineering (CAE) technique has become the third pillar of detonation research, along with theory and experiment, due to the detonation phenomenon is difficult to explain by the theoretical analysis, and the cost required to accredit the reliability of detonation products is very high, even some physical experiments of detonation are impossible. The numerical simulation technique can solve these complex problems in the real situation repeatedly and reduce the design cost and time stunningly. But the reliability of numerical simulation software and the serviceability of the computational result seriously hinders the extension, application and the self-restoration of the simulation software, restricts its independently innovational ability. This article deals with the physical modeling, numerical simulation, and software development of detonation in a unified way. Verification and validation and uncertainty quantification (V&V&UQ) is an important approach in ensuring the credibility of the modeling and simulation of detonation. V&V of detonation is based on our independently developed detonation multiphysics software-LAD2D. We propose the verification method based on mathematical theory and program function as well as availability of its program execution. Validation is executed by comparing with the experiment data. At last, we propose the future prospect of numerical simulation software and the CAE technique, and we also pay attention to the research direction of V&V&UQ.
基金supported by the Natural Science Foundation of Hubei Province,China(2016CFB287)
文摘As a powerful distributed data processing mechanism,MapReduce supports abundant parallel applications that process massive data on computer clusters.To process the massive data efficiently and correctly,a rational design for the MapReduce procedure is desired.An irrational MapReduce procedure can cause great waste of computing resources and even paralyze the execution system.With the wide application of MapReduce,the unavoidable drawback of irrational MapReduce procedures becomes increasingly serious.To solve this problem,a method for verifying the rationality of a MapReduce procedure before executing it on a computer cluster is proposed.This method constructs the rationality criteria for MapReduce,and then studies an automatic approach for modelling MapReduce with an executable model object Petri net(OPN).Finally,the approaches for automatically identifying the rationality criteria by analyzing the consequence of model execution is developed.The results from extensive case studies demonstrate that the proposed method is feasible and effective.
基金supported by the National Natural Science Foundation of China(61473100)
文摘In order to achieve a high precision in three-dimensional(3D) multi-camera measurement system, an efficient multi-cameracalibration method is proposed. A stitching method of large scalecalibration targets is deduced, and a fundamental of multi-cameracalibration based on the large scale calibration target is provided.To avoid the shortcomings of the method, the vector differencesof reprojection error with the presence of the constraint conditionof the constant rigid body transformation is modelled, and mini-mized by the Levenberg-Marquardt (LM) method. Results of thesimulation and observation data calibration experiment show thatthe accuracy of the system calibrated by the proposed methodreaches 2 mm when measuring distance section of 20 000 mmand scale section of 7 000 mm × 7 000 mm. Consequently, theproposed method of multi-camera calibration performs better thanthe fundamental in stability. This technique offers a more uniformerror distribution for measuring large scale space.
基金supported by the National High Technology Research and Development Program of China (863 Program) (2002AA1Z1490)Specialized Research Fund for the Doctoral Program of Higher Education (20040486049)the University Cooperative Research Fund of Huawei Technology Co., Ltd
文摘In order to deal with the limitations during the register transfer level verification, a new functional verification method based on the random testing for the system-level of system-on-chip is proposed.The validity of this method is proven theoretically.Specifically, testcases are generated according to many approaches of randomization.Moreover, the testbench for the system-level verification according to the proposed method is designed by using advanced modeling language.Therefore, under the circumstances that the testbench generates testcases quickly, the hardware/software co-simulation and co-verification can be implemented and the hardware/software partitioning planning can be evaluated easily.The comparison method is put to use in the evaluation approach of the testing validity.The evaluation result indicates that the efficiency of the partition testing is better than that of the random testing only when one or more subdomains are covered over with the area of errors, although the efficiency of the random testing is generally better than that of the partition testing.The experimental result indicates that this method has a good performance in the functional coverage and the cost of testing and can discover the functional errors as soon as possible.
基金supported by the National Basic Research Program of China(973 Program)(2010CB731905)
文摘The exact radar cross-section (RCS) measurement is difficult when the scattering of targets is low. Ful polarimetric cali-bration is one technique that offers the potential for improving the accuracy of RCS measurements. There are numerous polarimetric calibration algorithms. Some complex expressions in these algo-rithms cannot be easily used in an engineering practice. A radar polarimetric coefficients matrix (RPCM) with a simpler expression is presented for the monostatic radar polarization scattering matrix (PSM) measurement. Using a rhombic dihedral corner reflector and a metal ic sphere, the RPCM can be obtained by solving a set of equations, which can be used to find the true PSM for any target. An example for the PSM of a metal ic dish shows that the proposed method obviously improves the accuracy of cross-polarized RCS measurements.
文摘Two dynamic grey models DGM (1, 1) for the verification cycle and the lifecycle of measuring instrument based on time sequence and frequency sequence were set up, according to the statistical feature of examination data and weighting method. By a specific case, i.e. vernier caliper, it is proved that the fit precision and forecast precision of the models are much higher, the cycles are obviously different under different working conditions, and the forecast result of the frequency sequence model is better than that of the time sequence model. Combining dynamic grey model and auto-manufacturing case the controlling and information subsystems of verification cycle and the lifecycle based on information integration, multi-sensor controlling and management controlling were given. The models can be used in production process to help enterprise reduce error, cost and flaw.
基金supported by the National Natural Science Priority Foundation of China(60736006)National Natural Science Foundation of China for Youth(60802078)+1 种基金National Basic Research Program(973 Program)(51314)Hunan Provincial Innovation Foundation for Postgraduate
文摘A novel polarimetric calibration method for new target property measurement radar system is presented. Its applica- tion in the real radar system is also discussed. The analysis indicates that instantaneous polarization radar ([PR) has inherent cross-polarization measurement error. The proposed method can effectively eliminate this error, and thus enhance the polarization scattering matrix (PSM) measurement precision. The phase error caused by digital receiver's direct IF sampling and mixing of two orthogonal polarization channels can be removed. Consequently, the inherent error of target polarization scattering measurement of the instantaneous polarization radar system is well revised. It has good reference value for further ploarimetric calibration and high practical application prospect.
基金supported by the National Key Laboratory of Metrology and Calibration Technologythe Second Academy Institute of China Aerospace Science & Industry Corp
文摘The blackbody calibration targets applied for microwave radiometer's prelaunch calibration are optimized with its electromagnetic and thermal characteristics. Based on the method of emissivity optimization with radar cross section (RCS) simulation and the method of subgrid finite difference time domain (FDTD), the following design rules are summarized: that the round wedge is better than the square one, the best ratio from height to bottom radius is 4:1, for wide band calibration, the multilayer absorbing material coating is efficient to increase the emissivity, and the gradual thickness absorbing material coating is helpful to guarantee the uniform distribution of surface temperature even as it keeps a higher emissivity. Finally following the above conclusions, a new type of blackbody calibration target with the cellular array is preferred to improve the uniformity of polarization, which will increase the performance of the calibration targets further.
文摘A new method for array calibration of array gain and phase uncertainties, which severely degrade the performance of spatial spectrum estimation, is presented. The method is based on the idea of the instrumental sensors method (ISM), two well-calibrated sensors are added into the original array. By applying the principle of estimation of signal parameters via rotational invariance techniques (ESPRIT), the direction-of-arrivals (DOAs) and uncertainties can be estimated simultaneously through eigen-decomposition. Compared with the conventional ones, this new method has less computational complexity while has higher estimation precision, what's more, it can overcome the problem of ambiguity. Both theoretical analysis and computer simulations show the effectiveness of the proposed method.
基金Projects(51475254,51625503)supported by the National Natural Science Foundation of ChinaProject(MCM20150302)supported by the Joint Project of Tsinghua and China Mobile,ChinaProject supported by the joint Project of Tsinghua and Daimler Greater China Ltd.,Beijing,China
文摘Driving safety field(DSF) model has been proposed to represent comprehensive driving risk formed by interactions of driver-vehicle-road in mixed traffic environment. In this work, we establish an optimization model based on grey relation degree analysis to calibrate risk coefficients of DSF model. To solve the optimum solution, a genetic algorithm is employed. Finally, the DSF model is verified through a real-world driving experiment. Results show that the DSF model is consistent with driver's hazard perception and more sensitive than TTC. Moreover, the proposed DSF model offers a novel way for criticality assessment and decision-making of advanced driver assistance systems and intelligent connected vehicles.
基金the National Key Laboratory of Metrology and Calibration Technology,the Second Academy Institute of China Aerospace Science & Industry Corp.
文摘The development processes and the application achievements of space-borne microwave sounder pre-launch calibration technologies in China are introduced briefly. Then, the general project plan for pre-launch calibration, the latest research achievements on the optimization and development of the microwave wide band calibration targets, emissivity measurement technologies and the system level uncertainty analysis of the laboratory, and the thermal/vacuum microwave sounder calibration system for "FY-3" meteorological satellite are reported, respectively. Finally, the key technological problems of the calibration technologies under researching are analyzed predictively.
基金Project(2008AA04Z203) supported by the National High Technology Research and Development Program of China
文摘An optimal measurement pose number searching method was designed to improve the pose selection method.Several optimal robot measurement configurations were added to an initial pre-selected optimal configuration set to establish a new configuration set for robot calibration one by one.The root mean squares (RMS) of the errors of each end-effector poses after being calibrated by these configuration sets were calculated.The optimal number of the configuration set corresponding to the least RMS of pose error was then obtained.Calibration based on those poses selected by this algorithm can get higher end-effector accuracy,meanwhile consumes less time.An optimal pose set including optimal 25 measurement configurations is found during the simulation.Tracking errors after calibration by using these poses are 1.54,1.61 and 0.86 mm,and better than those before calibration which are 7.79,7.62 and 8.29 mm,even better than those calibrated by the random method which are 2.22,2.35 and 1.69 mm in directions X,Y and Z,respectively.