From the perspective of state-channel interaction,standard quantum teleportation can be viewed as a communication process characterized by both input and output,functioning as a quantum depolarizing channel.To achieve...From the perspective of state-channel interaction,standard quantum teleportation can be viewed as a communication process characterized by both input and output,functioning as a quantum depolarizing channel.To achieve a precise quantification of the quantumness introduced by this channel,we examine its uncertainties,which encompass both statedependent and state-independent uncertainties.Specifically,for qudit systems,we provide general formulas for these uncertainties.We analyze the uncertainties associated with standard quantum teleportation when induced by isotropic states,Werner states,and X-states,and we elucidate the correlation between these uncertainties and the parameters of the specific mixed states.Our findings demonstrate the validity of quantifying these uncertainties.展开更多
This study proposes a batch rapid quantitative analysis method for multiple elements by combining the advantages of standard curve(SC)and calibration-free laser-induced breakdown spectroscopy(CF-LIBS)technology to ach...This study proposes a batch rapid quantitative analysis method for multiple elements by combining the advantages of standard curve(SC)and calibration-free laser-induced breakdown spectroscopy(CF-LIBS)technology to achieve synchronous,rapid,and accurate measurement of elements in a large number of samples,namely,SC-assisted CF-LIBS.Al alloy standard samples,divided into calibration and test samples,were applied to validate the proposed method.SC was built based on the characteristic line of Pb and Cr in the calibration sample,and the contents of Pb and Cr in the test sample were calculated with relative errors of 6%and 4%,respectively.SC built using Cr with multiple characteristic lines yielded better calculation results.The relative contents of ten elements in the test sample were calculated using CF-LIBS.Subsequently,the SC-assisted CF-LIBS was executed,with the majority of the calculation relative errors falling within the range of 2%-5%.Finally,the Al and Na contents of the Al alloy were predicted.The results demonstrate that it effectively enables the rapid and accurate quantitative analysis of multiple elements after a single-element SC analysis of the tested samples.Furthermore,this quantitative analysis method was successfully applied to soil and Astragalus samples,realizing an accurate calculation of the contents of multiple elements.Thus,it is important to advance the LIBS quantitative analysis and its related applications.展开更多
基金Project supported by the National Natural Science Foundation of China(Grant No.12201300).
文摘From the perspective of state-channel interaction,standard quantum teleportation can be viewed as a communication process characterized by both input and output,functioning as a quantum depolarizing channel.To achieve a precise quantification of the quantumness introduced by this channel,we examine its uncertainties,which encompass both statedependent and state-independent uncertainties.Specifically,for qudit systems,we provide general formulas for these uncertainties.We analyze the uncertainties associated with standard quantum teleportation when induced by isotropic states,Werner states,and X-states,and we elucidate the correlation between these uncertainties and the parameters of the specific mixed states.Our findings demonstrate the validity of quantifying these uncertainties.
基金supported by the Major Science and TechnologyTechnol-ogy Projects in Gansu Province(No.22ZD6FA021-5)Industrial Support Project of Gansu Province(Nos.2023CYZC-19 and 2021CYZC-22)+1 种基金Science and Technol-ogy Project of Gansu Province(Nos.23YFFA0074,22JR5RA137,and 22JR5RA151)Central Leading Local Science and Technology Development Fund Projects(No.23ZYQA293).
文摘This study proposes a batch rapid quantitative analysis method for multiple elements by combining the advantages of standard curve(SC)and calibration-free laser-induced breakdown spectroscopy(CF-LIBS)technology to achieve synchronous,rapid,and accurate measurement of elements in a large number of samples,namely,SC-assisted CF-LIBS.Al alloy standard samples,divided into calibration and test samples,were applied to validate the proposed method.SC was built based on the characteristic line of Pb and Cr in the calibration sample,and the contents of Pb and Cr in the test sample were calculated with relative errors of 6%and 4%,respectively.SC built using Cr with multiple characteristic lines yielded better calculation results.The relative contents of ten elements in the test sample were calculated using CF-LIBS.Subsequently,the SC-assisted CF-LIBS was executed,with the majority of the calculation relative errors falling within the range of 2%-5%.Finally,the Al and Na contents of the Al alloy were predicted.The results demonstrate that it effectively enables the rapid and accurate quantitative analysis of multiple elements after a single-element SC analysis of the tested samples.Furthermore,this quantitative analysis method was successfully applied to soil and Astragalus samples,realizing an accurate calculation of the contents of multiple elements.Thus,it is important to advance the LIBS quantitative analysis and its related applications.