Analyzed the relation between time delay difference and time delay estimation errors, based on the principles of three-point locating, a reformed threshold method for time delay difference estimation of impulse signal...Analyzed the relation between time delay difference and time delay estimation errors, based on the principles of three-point locating, a reformed threshold method for time delay difference estimation of impulse signals, called as amendment estimation for short, is developed by introducing channel equalization technique to its conventional version, named as direct estimation in this paper, to improve the estimation stability. After inherent relationship between time delay and phase shift of signals is analyzed, an integer period error compensation method utilized the diversities of both contribution share and contribution mode of concerned estimates is proposed under the condition of high precision phase lag estimation. Finally, a cooperative multi-threshold estimation method composed of amendment and direct estimations to process impulse signals with three thresholds is established. In sea trials data tests of passive locating, this method improves the estimation precision of time delay difference efficiently. The experiments verify the theoretical predictions.展开更多
The work principle of all fiber optical current transducer (AFOCT) was introduced. By analyzing the characteristic of photo-detector's output, a measurement and signal processing scheme based on sine wave modulati...The work principle of all fiber optical current transducer (AFOCT) was introduced. By analyzing the characteristic of photo-detector's output, a measurement and signal processing scheme based on sine wave modulation and demodulation was put forward for eliminating the influence of light intensity change and modulation degree change. A digital signal processing system and a calibration scheme were also advanced. The experimental data show that the mean ratio error is 0.016 74% for direct current and 0.035% for alternating current, and the correlation coefficient of linearity is up to 0.999 982 4, meeting the precision requirement of 0.2 grade. Stability experiments and temperature drift experiments show the AFOCT has a better stable capability.展开更多
根据残留农药受到紫外光激发能够发出荧光的机理,研究了一种用于测量残留农药浓度的荧光光纤测量系统.该系统采用脉冲氙灯作为激发光源,光纤探测并传输荧光,电荷耦合器(CCD)作为荧光检测系统的光电转换器件.由于荧光是微弱信号,系统采...根据残留农药受到紫外光激发能够发出荧光的机理,研究了一种用于测量残留农药浓度的荧光光纤测量系统.该系统采用脉冲氙灯作为激发光源,光纤探测并传输荧光,电荷耦合器(CCD)作为荧光检测系统的光电转换器件.由于荧光是微弱信号,系统采用微弱信号处理电路对CCD输出信号进行了处理,并且采用相关双采样技术有效地抑制了CCD输出噪声的干扰.用该系统对吡虫啉溶液进行荧光分析,实现了对吡虫啉的快速测定,在5~100μg/L范围内,荧光强度和浓度基本呈线性关系,线性相关系数为0.9959.
Abstract:
Based on the mechanism that pesticide can emit fluorescence in the ultraviolet light, a fluorescence fiber- optical measuring system is developed for monitoring its concentration. This system makes use of pulse xenon lamp as exciting light source, the optical fiber detects and transmits the fluorescence, charge coupled device (CCD) is used to photo-electricity transformation component of fluorescence measuring system. Because fluorescence is a weak signal, the system uses the weak signal processing circuit to carry on processing to the CCD output signal and uses the correlated double sample technique to control the disturbance Of CCD output noise effectively. Carting on the fluorescence analysis with this system to the imidaeloprid, the imidacloprid fast determination was realized. In the scope of 5~100 μg/L, the fluorescence intensity and the density assume the linear relations, the linear correlation coefficient is basically 0. 9959.展开更多
Low-frequency signals have been proven valuable in the fields of target detection and geological exploration.Nevertheless,the practical implementation of these signals is hindered by large antenna diameters,limiting t...Low-frequency signals have been proven valuable in the fields of target detection and geological exploration.Nevertheless,the practical implementation of these signals is hindered by large antenna diameters,limiting their potential applications.Therefore,it is imperative to study the creation of lowfrequency signals using antennas with suitable dimensions.In contrast to conventional mechanical antenna techniques,our study generates low-frequency signals in the spatial domain utilizing the principle of the Doppler effect.We also defines the antenna array architecture,the timing sequency,and the radiating element signal waveform,and provides experimental prototypes including 8/64 antennas based on earlier research.In the conducted experiments,121 MHz,40 MHz,and 10 kHz composite signals are generated by 156 MHz radiating element signals.The composite signal spectrum matches the simulations,proving our low-frequency signal generating method works.This holds significant implications for research on generating low-frequency signals with small-sized antennas.展开更多
According to the features of the wideband underwater acoustic signals,an algorithm for the wideband ambiguity function is put forward based on Mellin transform.The wideband acoustic signal processing using the fast Me...According to the features of the wideband underwater acoustic signals,an algorithm for the wideband ambiguity function is put forward based on Mellin transform.The wideband acoustic signal processing using the fast Mellin transform is also explored.The theoretical analysis and simulation results show that the algorithm has not only high computation efficiency but also good concentration in wideband ambiguity domain.It suits for the wideband underwater acoustic signal processing.展开更多
文摘Analyzed the relation between time delay difference and time delay estimation errors, based on the principles of three-point locating, a reformed threshold method for time delay difference estimation of impulse signals, called as amendment estimation for short, is developed by introducing channel equalization technique to its conventional version, named as direct estimation in this paper, to improve the estimation stability. After inherent relationship between time delay and phase shift of signals is analyzed, an integer period error compensation method utilized the diversities of both contribution share and contribution mode of concerned estimates is proposed under the condition of high precision phase lag estimation. Finally, a cooperative multi-threshold estimation method composed of amendment and direct estimations to process impulse signals with three thresholds is established. In sea trials data tests of passive locating, this method improves the estimation precision of time delay difference efficiently. The experiments verify the theoretical predictions.
文摘The work principle of all fiber optical current transducer (AFOCT) was introduced. By analyzing the characteristic of photo-detector's output, a measurement and signal processing scheme based on sine wave modulation and demodulation was put forward for eliminating the influence of light intensity change and modulation degree change. A digital signal processing system and a calibration scheme were also advanced. The experimental data show that the mean ratio error is 0.016 74% for direct current and 0.035% for alternating current, and the correlation coefficient of linearity is up to 0.999 982 4, meeting the precision requirement of 0.2 grade. Stability experiments and temperature drift experiments show the AFOCT has a better stable capability.
文摘根据残留农药受到紫外光激发能够发出荧光的机理,研究了一种用于测量残留农药浓度的荧光光纤测量系统.该系统采用脉冲氙灯作为激发光源,光纤探测并传输荧光,电荷耦合器(CCD)作为荧光检测系统的光电转换器件.由于荧光是微弱信号,系统采用微弱信号处理电路对CCD输出信号进行了处理,并且采用相关双采样技术有效地抑制了CCD输出噪声的干扰.用该系统对吡虫啉溶液进行荧光分析,实现了对吡虫啉的快速测定,在5~100μg/L范围内,荧光强度和浓度基本呈线性关系,线性相关系数为0.9959.
Abstract:
Based on the mechanism that pesticide can emit fluorescence in the ultraviolet light, a fluorescence fiber- optical measuring system is developed for monitoring its concentration. This system makes use of pulse xenon lamp as exciting light source, the optical fiber detects and transmits the fluorescence, charge coupled device (CCD) is used to photo-electricity transformation component of fluorescence measuring system. Because fluorescence is a weak signal, the system uses the weak signal processing circuit to carry on processing to the CCD output signal and uses the correlated double sample technique to control the disturbance Of CCD output noise effectively. Carting on the fluorescence analysis with this system to the imidaeloprid, the imidacloprid fast determination was realized. In the scope of 5~100 μg/L, the fluorescence intensity and the density assume the linear relations, the linear correlation coefficient is basically 0. 9959.
基金Science and Technology Project of Aerospace Information Research Institute,Chinese Academy of Sciences(Y910340Z2F)Science and Technology Project of BBEF(E3E2010201)。
文摘Low-frequency signals have been proven valuable in the fields of target detection and geological exploration.Nevertheless,the practical implementation of these signals is hindered by large antenna diameters,limiting their potential applications.Therefore,it is imperative to study the creation of lowfrequency signals using antennas with suitable dimensions.In contrast to conventional mechanical antenna techniques,our study generates low-frequency signals in the spatial domain utilizing the principle of the Doppler effect.We also defines the antenna array architecture,the timing sequency,and the radiating element signal waveform,and provides experimental prototypes including 8/64 antennas based on earlier research.In the conducted experiments,121 MHz,40 MHz,and 10 kHz composite signals are generated by 156 MHz radiating element signals.The composite signal spectrum matches the simulations,proving our low-frequency signal generating method works.This holds significant implications for research on generating low-frequency signals with small-sized antennas.
基金Sponsored by National Nature Science Foundation of China(10474079)
文摘According to the features of the wideband underwater acoustic signals,an algorithm for the wideband ambiguity function is put forward based on Mellin transform.The wideband acoustic signal processing using the fast Mellin transform is also explored.The theoretical analysis and simulation results show that the algorithm has not only high computation efficiency but also good concentration in wideband ambiguity domain.It suits for the wideband underwater acoustic signal processing.