BACKGROUND:Fluid management is crucial to acute respiratory distress syndrome(ARDS)secondary to sepsis.However,choices of fluid resuscitation strategies and fluid input volumes remain a thorny problem.Our study aimed ...BACKGROUND:Fluid management is crucial to acute respiratory distress syndrome(ARDS)secondary to sepsis.However,choices of fluid resuscitation strategies and fluid input volumes remain a thorny problem.Our study aimed to elucidate the relationship between fluid balance and prognosis of ARDS patients secondary to sepsis.METHODS:Our study included 322 sepsis patients from Ruijin Hospital between 2014 and 2018,and 84 patients were diagnosed as ARDS within 72 hours after onset of sepsis according to Berlin ARDS Defi nition.RESULTS:Among the 322 sepsis patients,84(26.1%)were complicated with ARDS within 72 hours.ARDS patients had a lower oxygenation index(PaO2/FiO2166.4±71.0 vs.255.0±91.2,P<0.05),longer duration of mechanical ventilation(11[6-24]days vs.0[0-0]days,P<0.05)than those without ARDS.Sepsis patients with ARDS showed daily positive net fl uid balance during seven days compared with those without ARDS who showed daily negative net fluid balance since the second day with signifi cant statistical differences.Among the 84 sepsis patients with ARDS,58(69.0%)died.Mean daily fl uid input volumes were much lower in survivors than in non-survivors(43.2±16.7 mL/kg vs.51.0±25.2 mL/kg,P<0.05)while output volumes were much higher in survivors(45.2±19.8 mL/kg vs.40.2±22.7 mL/kg,P<0.05).Using binary logistic regression analysis,we found that the mean daily fl uid balance was independently associated with mortality of sepsis patients complicating with ARDS(P<0.05).CONCLUSIONS:Early negative fluid balance is independently associated with a better prognosis of sepsis patients complicated with ARDS.展开更多
The nitrogen doping/infusion of 650 MHz cavities for the circular electron positron collider(CEPC)is investigated in this study.Two 650 MHz 1-cell cavities are first treated via buffered chemical polishing(BCP),follow...The nitrogen doping/infusion of 650 MHz cavities for the circular electron positron collider(CEPC)is investigated in this study.Two 650 MHz 1-cell cavities are first treated via buffered chemical polishing(BCP),followed by nitrogen doping.A"2/6"condition is adopted,similar to that for 1.3 GHz cavities of Linear Coherent Light Source II.The quality factor of both cavities improved to 7×10^(10)in low fields,i.e.,higher than that obtained from the baseline test.One 650 MHz two-cell cavity is nitrogen infused at 165℃for 48 h with a BCP surface base.The intrinsic quality factor(Q0)reached6×10^(10)at 22 MV/m in the vertical test,and the maximum gradient is 25 MV/m,which exceeds the specification of the CEPC(4×10^(10)at 22 MV/m).展开更多
基金Shanghai Shenkang Hospital Development Center of China(SHDC12017116)Program for Outstanding Medical Academic,Shanghai Municipal Committee of Science and Technology(184119500900)+1 种基金Shanghai Municipal Commission of Health and Family Planning(2016ZB0206,ZHYY-ZXYJHZX-1-201702)and Shanghai Jiao Tong University School of Medicine(DLY201803)to Er-zhen ChenShanghai Municipal Commission of Health and Family Planning(201640089)to Zhi-tao Yang.
文摘BACKGROUND:Fluid management is crucial to acute respiratory distress syndrome(ARDS)secondary to sepsis.However,choices of fluid resuscitation strategies and fluid input volumes remain a thorny problem.Our study aimed to elucidate the relationship between fluid balance and prognosis of ARDS patients secondary to sepsis.METHODS:Our study included 322 sepsis patients from Ruijin Hospital between 2014 and 2018,and 84 patients were diagnosed as ARDS within 72 hours after onset of sepsis according to Berlin ARDS Defi nition.RESULTS:Among the 322 sepsis patients,84(26.1%)were complicated with ARDS within 72 hours.ARDS patients had a lower oxygenation index(PaO2/FiO2166.4±71.0 vs.255.0±91.2,P<0.05),longer duration of mechanical ventilation(11[6-24]days vs.0[0-0]days,P<0.05)than those without ARDS.Sepsis patients with ARDS showed daily positive net fl uid balance during seven days compared with those without ARDS who showed daily negative net fluid balance since the second day with signifi cant statistical differences.Among the 84 sepsis patients with ARDS,58(69.0%)died.Mean daily fl uid input volumes were much lower in survivors than in non-survivors(43.2±16.7 mL/kg vs.51.0±25.2 mL/kg,P<0.05)while output volumes were much higher in survivors(45.2±19.8 mL/kg vs.40.2±22.7 mL/kg,P<0.05).Using binary logistic regression analysis,we found that the mean daily fl uid balance was independently associated with mortality of sepsis patients complicating with ARDS(P<0.05).CONCLUSIONS:Early negative fluid balance is independently associated with a better prognosis of sepsis patients complicated with ARDS.
基金supported by the National Key Program for S&T Research and Development(No.2016YFA0400400)the Platform of Advanced Photon Source Technology R&D,National Natural Science Foundation of China(No.11505197).
文摘The nitrogen doping/infusion of 650 MHz cavities for the circular electron positron collider(CEPC)is investigated in this study.Two 650 MHz 1-cell cavities are first treated via buffered chemical polishing(BCP),followed by nitrogen doping.A"2/6"condition is adopted,similar to that for 1.3 GHz cavities of Linear Coherent Light Source II.The quality factor of both cavities improved to 7×10^(10)in low fields,i.e.,higher than that obtained from the baseline test.One 650 MHz two-cell cavity is nitrogen infused at 165℃for 48 h with a BCP surface base.The intrinsic quality factor(Q0)reached6×10^(10)at 22 MV/m in the vertical test,and the maximum gradient is 25 MV/m,which exceeds the specification of the CEPC(4×10^(10)at 22 MV/m).