To satisfy high-precision,widc-rangc,and real-time neutron flux measurement requirements by the International Thermonuclear Experimental Reactor(ITF.R),a data acquisition and control system based on fission chamber de...To satisfy high-precision,widc-rangc,and real-time neutron flux measurement requirements by the International Thermonuclear Experimental Reactor(ITF.R),a data acquisition and control system based on fission chamber detectors and fast controller technology,has been developed for neutron flux monitor in ITER Equatorial Port#7.The signal processing units which arc based on a field programmable gate array and the PXI Express platform arc designed to realize the neutron flux measurement with I ms time resolution and a fast response less than 0.2 ms,together with real-time timestamps provided by a timing hoard.The application of the wide-range algorithm allows the system to measure up to 10^10cps with a relative error of less than 5%.Furthermore,the system is managed and controlled by a software based on the Experimental Physics and Industrial Control System,compliant with COntrol.Data Access and Communication architecture.展开更多
A novel real time fast electron bremsstrahlung (FEB) diagnostic system based on the lutetium yttrium oxyorthosilicate scintillators (LYSO) and silicon photomultipliers (SiPM) has been developed for tokamak.The diagnos...A novel real time fast electron bremsstrahlung (FEB) diagnostic system based on the lutetium yttrium oxyorthosilicate scintillators (LYSO) and silicon photomultipliers (SiPM) has been developed for tokamak.The diagnostic system is dedicated to study the FEB emission in the hard x-ray (HXR) energy range between 10 and 200 keV during the lower hybrid current drive.The system consists of a detection module and three data acquisition and processing (DAP)boards.The detection module consists of annulus LYSO-SiPM detector array and a 12-channel preamplifier module.The DAP boards upload the data to the host computer for displaying and storing through PXI bus.The time and space resolutions of the system are 10 ms and 4 cm,respectively.The experimental results can show the evolution over time and the spatial distribution of FEB.This paper presents the system performance and typical discharge results.展开更多
A synchronous demodulation system is proposed and deployed for CO_2 dispersion interferometer on HL-2 A,which aims at high plasma density measurements and real-time feedback control.In order to make sure that the demo...A synchronous demodulation system is proposed and deployed for CO_2 dispersion interferometer on HL-2 A,which aims at high plasma density measurements and real-time feedback control.In order to make sure that the demodulator and the interferometer signal are synchronous in phase,a phase adjustment(PA) method has been developed for the demodulation system.The method takes advantages of the field programmable gate array parallel and pipeline process capabilities to carry out high performance and low latency PA.Some experimental results presented show that the PA method is crucial to the synchronous demodulation system and reliable to follow the fast change of the electron density.The system can measure the lineintegrated density with a high precision of 2.0?×10^(18)m^(-2).展开更多
A novel full-digital real-time neutron flux monitor(NFM) has been developed for the International Thermonuclear Experimental Reactor.A measurement range of 10~9 counts per second is achieved with 3 different sensiti...A novel full-digital real-time neutron flux monitor(NFM) has been developed for the International Thermonuclear Experimental Reactor.A measurement range of 10~9 counts per second is achieved with 3 different sensitive fission chambers.The Counting mode and Campbelling mode have been combined as a means to achieve higher measurement range.The system is based on high speed as well as parallel and pipeline processing of the field programmable gate array and has the ability to upload raw-data of analog-to-digital converter in real-time through the PXIe platform.With the advantages of the measurement range,real time performance and the ability of raw-data uploading,the digital NFM has been tested in HL-2 A experiments and reflected good experimental performance.展开更多
A real-time magnetic island reconstruction(MIR)system based on PCI express platform for HL-2 A tokamak is introduced.The front-end analog circuit and high performance analog-to-digital converters complete high-precisi...A real-time magnetic island reconstruction(MIR)system based on PCI express platform for HL-2 A tokamak is introduced.The front-end analog circuit and high performance analog-to-digital converters complete high-precision synchronous sampling of 18 channel Mirnov signals,and the application of PCIe platform and direct memory access technology enables high speed data transmission between graphics processing unit and field programmable gate array(FPGA).FPGA,as a mainstream high speed parallelizable computing tool,was used to implement the MIR algorithm,while a parameter table is established in an external double data rate SDRAM to improve the computational efficiency.The software of the MIR system is developed with Compute Unified Device Architecture 8.0 in Centos 6 system,which mainly realizes driver development,data transmission,network communication,parameter calculation and system control.This system has been tested in HL-2 A plasma discharge experiment,and the reconstructed magnetic island structure can achieve a spatial resolution of 1.02 cm while the time resolution can reach 2 ms.展开更多
Magnetic measurement and diagnostics are critical for the operation of magnetic confinement experimental facilities and plasma analysis, while differential signals are mostly detected by a detector. For this, we have ...Magnetic measurement and diagnostics are critical for the operation of magnetic confinement experimental facilities and plasma analysis, while differential signals are mostly detected by a detector. For this, we have developed and designed a stable and reliable data integration system for HL-2M magnetic measurement and magnetic diagnostics. The system will be used for realtime control of HL-2M after the construction of HL-2M is completed. The system is built based on the PXI platform, and the software system is based on the LABVIEW platform. Key technologies realized by the system primarily include drift compensation, pulse data acquisition technology, multi-threading processing technology and transmission control communication protocol. Trials of the system were successfully carried out on HL-2A, and the results showed that the system could fully meet the construction needs of HL-2M.展开更多
A new CO2 laser dispersion interferometer has been developed in the HL-2 M tokamak to measure the electron density.In order to meet the needs of high-precision measurement,a data acquisition system with real-time sign...A new CO2 laser dispersion interferometer has been developed in the HL-2 M tokamak to measure the electron density.In order to meet the needs of high-precision measurement,a data acquisition system with real-time signal conditioning(RSC)method is proposed.It can eliminate part of the impacts of environmental factors,such as mechanical vibration,light path changes,and plasma refraction effect during experiments.In harsh environments,the system can measure the line-integrated density with a high precision of 2×10^18 m^-2 with the RSC method.The system has been tested in a recent HL-2 A experimental campaign,and the results show that the RSC method plays an important role in the plasma electron density measurement.展开更多
The precision of plasma electron density and Faraday rotation angle measurement is a key indicator for far-infrared laser interferometer/polarimeter plasma diagnosis. To improve the precision, a new multi-channel high...The precision of plasma electron density and Faraday rotation angle measurement is a key indicator for far-infrared laser interferometer/polarimeter plasma diagnosis. To improve the precision, a new multi-channel high signal-to-noise ratio HCOOH interferometer/polarimeter has been developed on the HL-2A tokamak. It has a higher level requirement for phase demodulation precision. This paper introduces an improved real-time fast Fourier transform algorithm based on the field programmable gate array, which significantly improves the precision. We also apply a real-time error monitoring module (REMM) and a stable error inhibiting module (SEIM) for precision control to deal with the weak signal. We test the interferometer/polarimeter system with this improved precision control method in plasma discharge experiments and simulation experiments. The experimental results confirm that the plasma electron density precision is better than 1/3600 fringe and the Faraday rotation angle measurement precision is better than 1/900 fringe, while the temporal resolution is 80 ns. This performance can fully meet the requirements of HL-2A.展开更多
A digital pulse analysis system is an important diagnostic system in nuclear physics experimental research.In response to the demand for reflecting the particle state in a nuclear physics experiment,we have designed a...A digital pulse analysis system is an important diagnostic system in nuclear physics experimental research.In response to the demand for reflecting the particle state in a nuclear physics experiment,we have designed and developed a real-time digital pulse analysis system and applied it to the digital nuclear pulse waveform discrimination of different detectors in the HL-2M tokamak.The system is based on the peripheral component interconnect extensions for instrumentation(PXI)platform,while its software was written in LABVIEW.The key technologies involved in the system implementation include digital pulse analysis technology,digital discrimination technology,pulse height analysis technology,etc.The system has been applied to the plastic scintillator detector at the Neutron Source Lab of the University of Science and Technology of China.And the experimental results indicate that the system can discriminate between neutron(n)particles and gamma(γ)particles well when used to measure the plastic scintillator detector.展开更多
The extended Bonner sphere spectrometer (EBSS) at the HL-2A tokamak for the neutron spectrum is described. This device was developed on the basis of previous Bonner sphere spectrometry (BSS), aiming to obtain a mo...The extended Bonner sphere spectrometer (EBSS) at the HL-2A tokamak for the neutron spectrum is described. This device was developed on the basis of previous Bonner sphere spectrometry (BSS), aiming to obtain a more accurate neutron spectrum in the HL-2A tokamak hall. The previous BSS contained eight Bonner spheres (BS). This EBSS contains 13 3He-filled detectors embedded in polyethylene spheres (PS), pre-amplifiers, and a parallel processing data acquisition system (DAQ). A response matrix is simulated in Geant4 taking the effect of the environment into account.展开更多
文摘To satisfy high-precision,widc-rangc,and real-time neutron flux measurement requirements by the International Thermonuclear Experimental Reactor(ITF.R),a data acquisition and control system based on fission chamber detectors and fast controller technology,has been developed for neutron flux monitor in ITER Equatorial Port#7.The signal processing units which arc based on a field programmable gate array and the PXI Express platform arc designed to realize the neutron flux measurement with I ms time resolution and a fast response less than 0.2 ms,together with real-time timestamps provided by a timing hoard.The application of the wide-range algorithm allows the system to measure up to 10^10cps with a relative error of less than 5%.Furthermore,the system is managed and controlled by a software based on the Experimental Physics and Industrial Control System,compliant with COntrol.Data Access and Communication architecture.
基金National Natural Science Foundation of China (No. 11575184).
文摘A novel real time fast electron bremsstrahlung (FEB) diagnostic system based on the lutetium yttrium oxyorthosilicate scintillators (LYSO) and silicon photomultipliers (SiPM) has been developed for tokamak.The diagnostic system is dedicated to study the FEB emission in the hard x-ray (HXR) energy range between 10 and 200 keV during the lower hybrid current drive.The system consists of a detection module and three data acquisition and processing (DAP)boards.The detection module consists of annulus LYSO-SiPM detector array and a 12-channel preamplifier module.The DAP boards upload the data to the host computer for displaying and storing through PXI bus.The time and space resolutions of the system are 10 ms and 4 cm,respectively.The experimental results can show the evolution over time and the spatial distribution of FEB.This paper presents the system performance and typical discharge results.
基金supported by the National Magnetic Confinement Fusion Science Program of China (Nos.2014GB109001 and 2013GB104003)National Natural Science Foundation of China (Grant Nos.11375195,11505053,and 11575184)
文摘A synchronous demodulation system is proposed and deployed for CO_2 dispersion interferometer on HL-2 A,which aims at high plasma density measurements and real-time feedback control.In order to make sure that the demodulator and the interferometer signal are synchronous in phase,a phase adjustment(PA) method has been developed for the demodulation system.The method takes advantages of the field programmable gate array parallel and pipeline process capabilities to carry out high performance and low latency PA.Some experimental results presented show that the PA method is crucial to the synchronous demodulation system and reliable to follow the fast change of the electron density.The system can measure the lineintegrated density with a high precision of 2.0?×10^(18)m^(-2).
基金supported by National Natural Science Foundation of China (Nos.11375195,11575184)the National Magnetic Confinement Fusion Energy Development Research of China (No.2013GB104003)
文摘A novel full-digital real-time neutron flux monitor(NFM) has been developed for the International Thermonuclear Experimental Reactor.A measurement range of 10~9 counts per second is achieved with 3 different sensitive fission chambers.The Counting mode and Campbelling mode have been combined as a means to achieve higher measurement range.The system is based on high speed as well as parallel and pipeline processing of the field programmable gate array and has the ability to upload raw-data of analog-to-digital converter in real-time through the PXIe platform.With the advantages of the measurement range,real time performance and the ability of raw-data uploading,the digital NFM has been tested in HL-2 A experiments and reflected good experimental performance.
基金supported by National Natural Science Foundation of China(No.11575184)。
文摘A real-time magnetic island reconstruction(MIR)system based on PCI express platform for HL-2 A tokamak is introduced.The front-end analog circuit and high performance analog-to-digital converters complete high-precision synchronous sampling of 18 channel Mirnov signals,and the application of PCIe platform and direct memory access technology enables high speed data transmission between graphics processing unit and field programmable gate array(FPGA).FPGA,as a mainstream high speed parallelizable computing tool,was used to implement the MIR algorithm,while a parameter table is established in an external double data rate SDRAM to improve the computational efficiency.The software of the MIR system is developed with Compute Unified Device Architecture 8.0 in Centos 6 system,which mainly realizes driver development,data transmission,network communication,parameter calculation and system control.This system has been tested in HL-2 A plasma discharge experiment,and the reconstructed magnetic island structure can achieve a spatial resolution of 1.02 cm while the time resolution can reach 2 ms.
基金supported by National Natural Science Foundation of China(No.1157518)
文摘Magnetic measurement and diagnostics are critical for the operation of magnetic confinement experimental facilities and plasma analysis, while differential signals are mostly detected by a detector. For this, we have developed and designed a stable and reliable data integration system for HL-2M magnetic measurement and magnetic diagnostics. The system will be used for realtime control of HL-2M after the construction of HL-2M is completed. The system is built based on the PXI platform, and the software system is based on the LABVIEW platform. Key technologies realized by the system primarily include drift compensation, pulse data acquisition technology, multi-threading processing technology and transmission control communication protocol. Trials of the system were successfully carried out on HL-2A, and the results showed that the system could fully meet the construction needs of HL-2M.
文摘A new CO2 laser dispersion interferometer has been developed in the HL-2 M tokamak to measure the electron density.In order to meet the needs of high-precision measurement,a data acquisition system with real-time signal conditioning(RSC)method is proposed.It can eliminate part of the impacts of environmental factors,such as mechanical vibration,light path changes,and plasma refraction effect during experiments.In harsh environments,the system can measure the line-integrated density with a high precision of 2×10^18 m^-2 with the RSC method.The system has been tested in a recent HL-2 A experimental campaign,and the results show that the RSC method plays an important role in the plasma electron density measurement.
基金supported by National Natural Science Foundation of China (Nos. 11375195, 11575184 and 11275059)National Magnetic Confinement Fusion Energy Development Research (Nos. 2013GB104003 and 2014GB109001)
文摘The precision of plasma electron density and Faraday rotation angle measurement is a key indicator for far-infrared laser interferometer/polarimeter plasma diagnosis. To improve the precision, a new multi-channel high signal-to-noise ratio HCOOH interferometer/polarimeter has been developed on the HL-2A tokamak. It has a higher level requirement for phase demodulation precision. This paper introduces an improved real-time fast Fourier transform algorithm based on the field programmable gate array, which significantly improves the precision. We also apply a real-time error monitoring module (REMM) and a stable error inhibiting module (SEIM) for precision control to deal with the weak signal. We test the interferometer/polarimeter system with this improved precision control method in plasma discharge experiments and simulation experiments. The experimental results confirm that the plasma electron density precision is better than 1/3600 fringe and the Faraday rotation angle measurement precision is better than 1/900 fringe, while the temporal resolution is 80 ns. This performance can fully meet the requirements of HL-2A.
基金supported by National Natural Science Foundation of China (No. 1157518)
文摘A digital pulse analysis system is an important diagnostic system in nuclear physics experimental research.In response to the demand for reflecting the particle state in a nuclear physics experiment,we have designed and developed a real-time digital pulse analysis system and applied it to the digital nuclear pulse waveform discrimination of different detectors in the HL-2M tokamak.The system is based on the peripheral component interconnect extensions for instrumentation(PXI)platform,while its software was written in LABVIEW.The key technologies involved in the system implementation include digital pulse analysis technology,digital discrimination technology,pulse height analysis technology,etc.The system has been applied to the plastic scintillator detector at the Neutron Source Lab of the University of Science and Technology of China.And the experimental results indicate that the system can discriminate between neutron(n)particles and gamma(γ)particles well when used to measure the plastic scintillator detector.
基金supported by National Natural Science Foundation of China (No. 11375195, No. 11575184)the National Magnetic Confinement Fusion Energy Development Research (2013GB104003)
文摘The extended Bonner sphere spectrometer (EBSS) at the HL-2A tokamak for the neutron spectrum is described. This device was developed on the basis of previous Bonner sphere spectrometry (BSS), aiming to obtain a more accurate neutron spectrum in the HL-2A tokamak hall. The previous BSS contained eight Bonner spheres (BS). This EBSS contains 13 3He-filled detectors embedded in polyethylene spheres (PS), pre-amplifiers, and a parallel processing data acquisition system (DAQ). A response matrix is simulated in Geant4 taking the effect of the environment into account.