Aiming at addressing the issues of unclear dynamic response mechanisms and insufficient quantification of temperature coupling effects in building structures under long-duration blast loads,this study investigates typ...Aiming at addressing the issues of unclear dynamic response mechanisms and insufficient quantification of temperature coupling effects in building structures under long-duration blast loads,this study investigates typical composite beam-slab structures through integrated blast shock tube experiments and multiscale numerical simulations using Voronoi-coupled Finite-Discrete Element Method(VoroFDEM).The research systematically reveals the dynamic response mechanisms and damage evolution patterns of composite beam-slab structures subjected to prolonged blast loading.An environmenttemperature-coupled P-I curve damage assessment system is established,and a rapid evaluation method based on image crack characteristics is proposed,achieving innovative transition from traditional mechanical indicators to intelligent recognition paradigms.Results demonstrate that composite beam-slab structures exhibit three-phase failure modes:elastic vibration,plastic hinge formation,and global collapse.Numerical simulations identify the brittle-to-ductile transition temperature threshold at-10℃,and establish a temperature-dependent piecewise function-based P-I curve prediction model,whose overpressure asymptote displays nonlinear temperature sensitivity within-50-30℃.A novel dual-mode evaluation methodology integrating Voro-FDEM numerical simulations with image-based damage feature recognition is developed,enabling quantitative mapping between crack area and destruction levels.These findings provide theoretical foundations and technical pathways for rapid blast damage assessment and protective engineering design.展开更多
A reasonable heat treatment process for TC4 ELI titanium alloy is crucial to tune microstructures to improve its explosion resistance.However,there is limited investigation on tuning microstructures of TC4 ELI to impr...A reasonable heat treatment process for TC4 ELI titanium alloy is crucial to tune microstructures to improve its explosion resistance.However,there is limited investigation on tuning microstructures of TC4 ELI to improve explosion resistance.Moreover,the current challenge is quantifying microstructural changes'effects on explosion resistance and incorporating microstructural changes into finite element models.This work aims to tune microstructures to improve explosion resistance and elucidate their anti-explosion mechanism,and find a suitable method to incorporate microstructural changes into finite element models.In this work,we systematically study the deformation and failure characteristics of TC4 ELI plates with varying microstructures using an air explosion test and LS-DYNA finite element modeling.The Johnson-Cook(JC)constitutive parameters are used to quantify the effects of microstructural changes on explosion resistance and incorporate microstructural changes into finite element models.Because of the heat treatment,one plate has equiaxed microstructure and the other has bimodal microstructure.The convex of the plate after the explosion has a quadratic relationship with the charge mass,and the simulation results demonstrate high reliability,with the error less than 17.5%.Therefore,it is feasible to obtain corresponding JC constitutive parameters based on the differences in microstructures and mechanical properties and characterize the effects of microstructural changes on explosion resistance.The bimodal target exhibits excellent deformation resistance.The response of bimodal microstructure to the shock wave may be more intense under explosive loading.The well-coordinated structure of the bimodal target enhances its resistance to deformation.展开更多
基金supported by Open Research Fund of State Key Laboratory of Target Vulnerability Assessment,Defense Engineering Institute,AMS,PLA(Grant No.YSX2024KFPG002)。
文摘Aiming at addressing the issues of unclear dynamic response mechanisms and insufficient quantification of temperature coupling effects in building structures under long-duration blast loads,this study investigates typical composite beam-slab structures through integrated blast shock tube experiments and multiscale numerical simulations using Voronoi-coupled Finite-Discrete Element Method(VoroFDEM).The research systematically reveals the dynamic response mechanisms and damage evolution patterns of composite beam-slab structures subjected to prolonged blast loading.An environmenttemperature-coupled P-I curve damage assessment system is established,and a rapid evaluation method based on image crack characteristics is proposed,achieving innovative transition from traditional mechanical indicators to intelligent recognition paradigms.Results demonstrate that composite beam-slab structures exhibit three-phase failure modes:elastic vibration,plastic hinge formation,and global collapse.Numerical simulations identify the brittle-to-ductile transition temperature threshold at-10℃,and establish a temperature-dependent piecewise function-based P-I curve prediction model,whose overpressure asymptote displays nonlinear temperature sensitivity within-50-30℃.A novel dual-mode evaluation methodology integrating Voro-FDEM numerical simulations with image-based damage feature recognition is developed,enabling quantitative mapping between crack area and destruction levels.These findings provide theoretical foundations and technical pathways for rapid blast damage assessment and protective engineering design.
基金National Key Laboratory of Science and Technology on Materials under Shock and Impact(Grant No.WDZC2022-4)to provide fund for conducting experiments。
文摘A reasonable heat treatment process for TC4 ELI titanium alloy is crucial to tune microstructures to improve its explosion resistance.However,there is limited investigation on tuning microstructures of TC4 ELI to improve explosion resistance.Moreover,the current challenge is quantifying microstructural changes'effects on explosion resistance and incorporating microstructural changes into finite element models.This work aims to tune microstructures to improve explosion resistance and elucidate their anti-explosion mechanism,and find a suitable method to incorporate microstructural changes into finite element models.In this work,we systematically study the deformation and failure characteristics of TC4 ELI plates with varying microstructures using an air explosion test and LS-DYNA finite element modeling.The Johnson-Cook(JC)constitutive parameters are used to quantify the effects of microstructural changes on explosion resistance and incorporate microstructural changes into finite element models.Because of the heat treatment,one plate has equiaxed microstructure and the other has bimodal microstructure.The convex of the plate after the explosion has a quadratic relationship with the charge mass,and the simulation results demonstrate high reliability,with the error less than 17.5%.Therefore,it is feasible to obtain corresponding JC constitutive parameters based on the differences in microstructures and mechanical properties and characterize the effects of microstructural changes on explosion resistance.The bimodal target exhibits excellent deformation resistance.The response of bimodal microstructure to the shock wave may be more intense under explosive loading.The well-coordinated structure of the bimodal target enhances its resistance to deformation.