This research was conducted to study the performances of the heat and multilayer reflection insulators used for buildings in South Korea to realize eco-friendly, low-energy-consumption, green construction, and to cont...This research was conducted to study the performances of the heat and multilayer reflection insulators used for buildings in South Korea to realize eco-friendly, low-energy-consumption, green construction, and to contribute to energy consumption reduction in buildings and to the nation's greenhouse gas emission reduction policy (targeting 30% reduction compared to BAUCousiness as usual) by 2020). The heat insulation performance test is about the temperatures on surfaces of test piece. The high air temperature and the low air temperature were measured to determine the overall heat transfer coefficient and thermal conductivity. The conclusions are drawn that the heat transmission coefficients for each type of existing reflection insulator are: A-1 (0.045 W/(m-K)), A-2 (0.031 W/(m.K)), A-3 (0.042 W/(m.K)), A-4 (0.078 W/(m.K)), and the average heat conductivity is 0.049 W/(m-K); The heat conductivity for each type of Styrofoam insulator are 0.030 W/(m.K) for B-l, 0.032 W/(m-K) for B-2, 0.037 W/(m'K) for B-3, 0.037 W/(m.K) for B-4, and the average heat conductivity is 0.035 W/(m'K) regardless of the thickness of the insulator; The heat conductivity values of the multilayer reflection insulators are converted based on the thickness and type C-1 (0.020 W/(m.K)), C-2 (0.018 W/(m.K)), C-3 (0.016 W/(m.K)), and C-4 (0.012 W/(m.K)); The multilayer reflection insulator keeps the indoor-side surface temperature high (during winter) or low (in summer), enhances the comfort of the building occupants, and conducts heating and moisture resistance to prevent dew condensation on the glass-outer-wall surface.展开更多
The thermal-environment characteristics of the existing forced-convection cooling system were compared with those of the convective cooling system, which combined the radiant-floor cooling system using floor-heating p...The thermal-environment characteristics of the existing forced-convection cooling system were compared with those of the convective cooling system, which combined the radiant-floor cooling system using floor-heating panel typically applied to apartments in South Korea with the forced-convection cooling system using improved fan coil unit. The subjective warm/cool-feeling responses to the combined radiant-floor and convective cooling system in the questionnaire survey conducted among the test subjects were analyzed to establish the basic data for the combined cooling system. The results show that in the thermal-equilibrium condition, the vertical air temperature difference in the model living room is larger in the forced-convection-cooling condition. Most of the subjects feel a proper warm/cool feeling on their entire body, but they feel colder on the foot and lower body in the combined-cooling condition.展开更多
This work aims to understand the relationship between the member angle limit and the energy ratio for 24 test samples of composite beams and CFT square steel tube columns. This work also compares the formula applicabi...This work aims to understand the relationship between the member angle limit and the energy ratio for 24 test samples of composite beams and CFT square steel tube columns. This work also compares the formula applicability for member angle limit with the previous test result to provide the basic data for the design of composite beam-CFT column. The evaluation of the member angle limit was performed with concrete compressive strength (fC =22.16 MPa, 30.49 MPa), breadth-to-thickness ratio (B/t=25.0, 33.3, 43.5), and axial capacity ratio (N/N0=0, 0.3, 0.4, 0.5) as the main variables of the test samples. For the relationship between the member angle limit (Ru) and the energy ratio (ES/EC ), the test result shows that the energy ratio becomes lower as the axial capacity ratio and the breadth-to-thickness ratio increase. The energy ratio is lower for the Type B test sample compared with that of Types A and C. For the formula suggested by SATO, the test samples are distributed evenly for comparison between test values and the member angle limit; however, other formulas indicate a deviation. Specifically, for the comparison between R u,cal and R u (Test), Maeda's formula shows severe deviation.展开更多
Practical techniques for smooth geodesic patterning of membrane structures were investigated.For the geodesic search,adjustment of the subplane of the extracted elements series was proposed,and various spline approxim...Practical techniques for smooth geodesic patterning of membrane structures were investigated.For the geodesic search,adjustment of the subplane of the extracted elements series was proposed,and various spline approximation methods were used to flatten the strip for the generation of a smooth pattern.This search approach is very simple,and the geodesic line could be easily attained by the proposed method without the need for a difficult computation method.Smooth cutting patterning can also be generated by spline approximation without the noise in discrete nodal information.Additionally,the geodesic cutting pattern saved about 21%of the required area for the catenary model due to the reduction of the curvature of the planar pattern seam line.展开更多
Recently, urban high temperature phenomenon has become a problem which results from human activities, the increase in energy consumption, and land-cover change in urban areas. As extremely hot weather caused by urban ...Recently, urban high temperature phenomenon has become a problem which results from human activities, the increase in energy consumption, and land-cover change in urban areas. As extremely hot weather caused by urban high temperature continues, demand for power is increased and results in the degradation of electricity reserves. The current trend in climate change, regardless of the summer and winter power demand, is likely to have much effect on the power demand. Thus, sensitivity to electricity consumption in urban areas due to climate change was researched. The results show that, 1) the basic unit of the sensitivity to electricity consumption in the target areas is 1.25-1.58W/(m2.℃); 2) The maximum sensitivity is recorded at around 8:00 pm in the area crowded with commercial and business area. And in the business area, electricity consumption load is even from 9:00 am to 6:00 pm.展开更多
基金Project(NRF-2010-0024155) supported by the National Research Foundation of Korea
文摘This research was conducted to study the performances of the heat and multilayer reflection insulators used for buildings in South Korea to realize eco-friendly, low-energy-consumption, green construction, and to contribute to energy consumption reduction in buildings and to the nation's greenhouse gas emission reduction policy (targeting 30% reduction compared to BAUCousiness as usual) by 2020). The heat insulation performance test is about the temperatures on surfaces of test piece. The high air temperature and the low air temperature were measured to determine the overall heat transfer coefficient and thermal conductivity. The conclusions are drawn that the heat transmission coefficients for each type of existing reflection insulator are: A-1 (0.045 W/(m-K)), A-2 (0.031 W/(m.K)), A-3 (0.042 W/(m.K)), A-4 (0.078 W/(m.K)), and the average heat conductivity is 0.049 W/(m-K); The heat conductivity for each type of Styrofoam insulator are 0.030 W/(m.K) for B-l, 0.032 W/(m-K) for B-2, 0.037 W/(m'K) for B-3, 0.037 W/(m.K) for B-4, and the average heat conductivity is 0.035 W/(m'K) regardless of the thickness of the insulator; The heat conductivity values of the multilayer reflection insulators are converted based on the thickness and type C-1 (0.020 W/(m.K)), C-2 (0.018 W/(m.K)), C-3 (0.016 W/(m.K)), and C-4 (0.012 W/(m.K)); The multilayer reflection insulator keeps the indoor-side surface temperature high (during winter) or low (in summer), enhances the comfort of the building occupants, and conducts heating and moisture resistance to prevent dew condensation on the glass-outer-wall surface.
基金Project(NRF-2013RIA2A1A01014020)supported by the National Research Foundation of Korea
文摘The thermal-environment characteristics of the existing forced-convection cooling system were compared with those of the convective cooling system, which combined the radiant-floor cooling system using floor-heating panel typically applied to apartments in South Korea with the forced-convection cooling system using improved fan coil unit. The subjective warm/cool-feeling responses to the combined radiant-floor and convective cooling system in the questionnaire survey conducted among the test subjects were analyzed to establish the basic data for the combined cooling system. The results show that in the thermal-equilibrium condition, the vertical air temperature difference in the model living room is larger in the forced-convection-cooling condition. Most of the subjects feel a proper warm/cool feeling on their entire body, but they feel colder on the foot and lower body in the combined-cooling condition.
基金supported by the Basic Science Research Program of the National Research Foundation of Korea (NRF) and funded by the Ministry of Education,Science and Technology (2011-0009227)
文摘This work aims to understand the relationship between the member angle limit and the energy ratio for 24 test samples of composite beams and CFT square steel tube columns. This work also compares the formula applicability for member angle limit with the previous test result to provide the basic data for the design of composite beam-CFT column. The evaluation of the member angle limit was performed with concrete compressive strength (fC =22.16 MPa, 30.49 MPa), breadth-to-thickness ratio (B/t=25.0, 33.3, 43.5), and axial capacity ratio (N/N0=0, 0.3, 0.4, 0.5) as the main variables of the test samples. For the relationship between the member angle limit (Ru) and the energy ratio (ES/EC ), the test result shows that the energy ratio becomes lower as the axial capacity ratio and the breadth-to-thickness ratio increase. The energy ratio is lower for the Type B test sample compared with that of Types A and C. For the formula suggested by SATO, the test samples are distributed evenly for comparison between test values and the member angle limit; however, other formulas indicate a deviation. Specifically, for the comparison between R u,cal and R u (Test), Maeda's formula shows severe deviation.
基金Project(12 High-tech Urban C22)supported by High-tech Urban Development Program,Ministry of Land,Transport and Moritime Affairs of Korea
文摘Practical techniques for smooth geodesic patterning of membrane structures were investigated.For the geodesic search,adjustment of the subplane of the extracted elements series was proposed,and various spline approximation methods were used to flatten the strip for the generation of a smooth pattern.This search approach is very simple,and the geodesic line could be easily attained by the proposed method without the need for a difficult computation method.Smooth cutting patterning can also be generated by spline approximation without the noise in discrete nodal information.Additionally,the geodesic cutting pattern saved about 21%of the required area for the catenary model due to the reduction of the curvature of the planar pattern seam line.
基金Project(NRF-20110030631) supported by the National Research Foundation of Korea Grant funded by the Korean Government
文摘Recently, urban high temperature phenomenon has become a problem which results from human activities, the increase in energy consumption, and land-cover change in urban areas. As extremely hot weather caused by urban high temperature continues, demand for power is increased and results in the degradation of electricity reserves. The current trend in climate change, regardless of the summer and winter power demand, is likely to have much effect on the power demand. Thus, sensitivity to electricity consumption in urban areas due to climate change was researched. The results show that, 1) the basic unit of the sensitivity to electricity consumption in the target areas is 1.25-1.58W/(m2.℃); 2) The maximum sensitivity is recorded at around 8:00 pm in the area crowded with commercial and business area. And in the business area, electricity consumption load is even from 9:00 am to 6:00 pm.