期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Study on X-ray and electron-excited fluorescence spectroscopy of tungsten using TES
1
作者 Bing-Jun Wu jing-kai xia +5 位作者 Shuo Zhang Robin Cantor Wen-Tao Wu Jin-Hua Li xiao-Ming Xie Zhi Liu 《Nuclear Science and Techniques》 2025年第4期119-126,共8页
In the exploration of celestial bodies,such as Mars,the Moon,and asteroids,X-ray fluorescence analysis has emerged as a critical tool for elemental analysis.However,the varying selection rules and excitation sources i... In the exploration of celestial bodies,such as Mars,the Moon,and asteroids,X-ray fluorescence analysis has emerged as a critical tool for elemental analysis.However,the varying selection rules and excitation sources introduce complexity.Specifically,these discrepancies can cause variations in the intensities of the characteristic spectral lines emitted by identical elements.These variations,compounded by the minimal energy spacing between these spectral lines,pose substantial challenges for conventional silicon drift detectors(SDD),hindering their ability to accurately differentiate these lines and provide detailed insights into the material structure.To overcome this challenge,a cryogenic X-ray spectrometer based on transition-edge sensor(TES)detector arrays is required to achieve precise measurements.This study measured and analyzed the K-edge characteristic lines of copper and the diverse L-edge characteristic lines of tungsten using a comparative analysis of the electron and X-ray excitation processes.For the electron excitation experiments,copper and tungsten targets were employed as X-ray sources,as they emit distinctive X-ray spectra upon electron-beam bombardment.In the photon excitation experiments,a molybdenum target was used to produce a continuous spectrum with the prominent Mo Kαlines to emit pure copper and tungsten samples.TES detectors were used for the comparative spectroscopic analysis.The initial comparison revealed no substantial differences in the Kαand Kβlines of copper across different excitation sources.Similarly,the Lαlines of tungsten exhibited uniformity under different excitation sources.However,this investigation revealed pronounced differences within the Lβline series.The study found that XRF spectra preferentially excite outer-shell electrons,in contrast to intrinsic spectra,owing to different photon and electron interaction mechanisms.Photon interactions are selection-ruledependent and involve a single electron,whereas electron interactions can involve multiple electrons without such limitations.This leads to varied excitation transitions,as evidenced in the observed Lβline series. 展开更多
关键词 X-ray spectra X-ray emission spectra and fluorescence Superconducting transition-edge sensor X-RAY γ-ray spectrometers
在线阅读 下载PDF
Transition edge sensor-based detector:from X-ray to γ-ray 被引量:1
2
作者 Shuo Zhang jing-kai xia +15 位作者 Tao Sun Wen-Tao Wu Bing-Jun Wu Yong-Liang Wang Robin Cantor Ke Han xiao-Peng Zhou Hao-Ran Liu Fu-You Fan Si-Ming Guo Jun-Cheng Liang De-Hong Li Yan-Ru Song Xu-Dong Ju Qiang Fu Zhi Liu 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2022年第7期61-72,共12页
A transition edge sensor(TES)is extremely sensitive to changes in temperature,and combined with a high-Z metal of a certain thickness,it can realize high-energy resolution measurements of particles such as X-rays.X-ra... A transition edge sensor(TES)is extremely sensitive to changes in temperature,and combined with a high-Z metal of a certain thickness,it can realize high-energy resolution measurements of particles such as X-rays.X-rays with energies below 10 keV have a weak penetrating ability,hence,only gold or bismuth of a few micrometers in thickness can guarantee a quantum efficiency higher than 70%.Therefore,the entire structure of the TES X-ray detector in this energy range can be realized using a microfabrication process.However,for X-rays or γ-rays from 10 keV to 200 keV,submillimeter absorber layers are required,which cannot be realized using the microfabrication process.This paper first briefly introduces a set of TES X-ray detectors and their auxiliary systems,and then focuses on the introduction of the TES γ-ray detector with an absorber based on a submillimeter lead-tin alloy sphere.The detector achieved a quantum efficiency above 70% near 100 keV and an energy resolution of approximately 161.5 eV at 59.5 keV. 展开更多
关键词 Synchrotron radiation INSTRUMENTATION X-ray spectrometers Cryogenic detectors Transition edge sensor
在线阅读 下载PDF
Aging behavior of large area MCP–PMT
3
作者 Wen-Wen Wang Sen Qian +16 位作者 Ming Qi jing-kai xia Ya-Ping Cheng Zhe Ning Yue-Kun Heng Shu-Lin Liu Shu-Guang Si Jian-Ning Sun Dong Li Xing-Chao Wang Guo-Rui Huang Jing-Shou Tian Yong-Lin Wei Hu-Lin Liu Wei-Hua Li Xing Wang Li-Wei Xin 《Nuclear Science and Techniques》 SCIE CAS CSCD 2016年第2期136-140,共5页
The Institute of High Energy Physics, Chinese Academy of Sciences have designed a new type of photomultiplier tube(PMT) based on microchannel plates(MCPs) with large area photocathode, known as large area microchannel... The Institute of High Energy Physics, Chinese Academy of Sciences have designed a new type of photomultiplier tube(PMT) based on microchannel plates(MCPs) with large area photocathode, known as large area microchannel plate photomultiplier tube(MCP–PMT). The aging characteristics of the large area MCP–PMTs are different from dynode PMTs and small proximity-focus MCP–PMT. In this work, a prototype large area MCP–PMT was aged by operating with nearly 1000 photoelectrons per pulse for 3 months, and aging process of the MCP–PMT was discussed based on the aging curve. 展开更多
关键词 MCP-PMT 面积 老化行为 光电倍增管 高能物理研究所 微通道板 中国科学院 近贴聚焦
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部