The recently discovered,extremely proton-rich nuclide 18 Mg exhibits ground-state decay via two sequential two-proton(2p)emissions through the intermediate nucleus,16Ne.This study investigates the structure and the in...The recently discovered,extremely proton-rich nuclide 18 Mg exhibits ground-state decay via two sequential two-proton(2p)emissions through the intermediate nucleus,16Ne.This study investigates the structure and the initial 2p decay mechanism of^(18)Mgby examining the density and correlations of the valence protons using a three-body Gamow coupled-channel method.The results show that the ground state of^(18)Mgis significantly influenced by the continuum,resulting in a significant s-wave component.However,based on the current framework,this does not lead to a significant deviation in mirror symmetry in either the structure or spectroscopy of the 18Mg-18C pair.Additionally,the time evolution analysis of the^(18)Mgground state suggests a simultaneous 2p emission during the first step of decay.The observed nucleon-nucleon correlations align with those of the light-mass 2p emitters,indicating a consistent decay behavior within this nuclear region.展开更多
A newly developed digital data acquisition system,which is based on the digital pulse processor Pixie-16 modules by XIA LLC,was tested with the c-ray detector array of the China Institute of Atomic Energy using the cr...A newly developed digital data acquisition system,which is based on the digital pulse processor Pixie-16 modules by XIA LLC,was tested with the c-ray detector array of the China Institute of Atomic Energy using the cray source and in-beam c-rays.A comparison between this digital data acquisition system and the conventional analog data acquisition system was made.At a low count rate,both systems exhibit good and comparable energy resolutions.At a high count rate above 8.8 k/s,while the energy resolution obtained by the analog system deteriorates significantly,the energy resolution obtained by the digital system is nearly unchanged.Meanwhile,experimental data with higher statistics can be collected by the digital system.The advantage of this digital system over the conventional analog system can be ascribed to its excellent capability of handling pile-up pulses at higher count rates,and the fact that it has nearly no dead time in data transmission and conversion.展开更多
基金the National Key Research and Development Program(MOST 2022YFA1602303 and MOST 2023YFA1606404)the National Natural Science Foundation of China(Nos.12347106,2147101,11925502,11935001 and 11961141003)the Strategic Priority Research Program of Chinese Academy of Sciences(No.XDB34030000).
文摘The recently discovered,extremely proton-rich nuclide 18 Mg exhibits ground-state decay via two sequential two-proton(2p)emissions through the intermediate nucleus,16Ne.This study investigates the structure and the initial 2p decay mechanism of^(18)Mgby examining the density and correlations of the valence protons using a three-body Gamow coupled-channel method.The results show that the ground state of^(18)Mgis significantly influenced by the continuum,resulting in a significant s-wave component.However,based on the current framework,this does not lead to a significant deviation in mirror symmetry in either the structure or spectroscopy of the 18Mg-18C pair.Additionally,the time evolution analysis of the^(18)Mgground state suggests a simultaneous 2p emission during the first step of decay.The observed nucleon-nucleon correlations align with those of the light-mass 2p emitters,indicating a consistent decay behavior within this nuclear region.
基金supported by the National Key R&D Program of China(No.2018YFA0404403)the National Natural Science Foundation of China(Nos.12035001,12075006,11675003)the State Key Laboratory of Nuclear Physics and Technology,PKU(No.NPT2020KFY18)。
文摘A newly developed digital data acquisition system,which is based on the digital pulse processor Pixie-16 modules by XIA LLC,was tested with the c-ray detector array of the China Institute of Atomic Energy using the cray source and in-beam c-rays.A comparison between this digital data acquisition system and the conventional analog data acquisition system was made.At a low count rate,both systems exhibit good and comparable energy resolutions.At a high count rate above 8.8 k/s,while the energy resolution obtained by the analog system deteriorates significantly,the energy resolution obtained by the digital system is nearly unchanged.Meanwhile,experimental data with higher statistics can be collected by the digital system.The advantage of this digital system over the conventional analog system can be ascribed to its excellent capability of handling pile-up pulses at higher count rates,and the fact that it has nearly no dead time in data transmission and conversion.