期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Ultrahard X-ray multifunctional application beamline at the SSRF 被引量:1
1
作者 Ke Yang Zhao-Hui Dong +4 位作者 Chun-Yin Zhou Zi-Long Zhao dong-xu liang Sai-Chao Cao Ai-Guo Li 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第6期14-25,共12页
The ultrahard X-ray multifunctional application beamline(BL12SW)is a phase-II beamline project at the Shanghai Syn-chrotron Radiation Facility.The primary X-ray techniques used at the beamline are high-energy X-ray di... The ultrahard X-ray multifunctional application beamline(BL12SW)is a phase-II beamline project at the Shanghai Syn-chrotron Radiation Facility.The primary X-ray techniques used at the beamline are high-energy X-ray diffraction and imaging using white and monochromatic light.The main scientific objectives of ultrahard X-ray beamlines are focused on two research areas.One is the study of the structural properties of Earth’s interior and new materials under extreme high-temperature and high-pressure conditions,and the other is the characterization of materials and processes in near-real service environments.The beamline utilizes a superconducting wiggler as the light source,with two diamond windows and SiC discs to filter out low-energy light(primarily below 30 keV)and a Cu filter assembly to control the thermal load entering the subsequent optical components.The beamline is equipped with dual monochromators.The first was a meridional bending Laue monochromator cooled by liquid nitrogen,achieving a full-energy coverage of 30-162 keV.The second was a sagittal bending Laue monochromator installed in an external building,providing a focused beam in the horizontal direction with an energy range of 60-120 keV.There were four experimental hutches:two large-volume press experimental hutches(LVP1 and LVP2)and two engineering material experimental hutches(ENG1 and ENG2).Each hutch was equipped with various near-real service conditions to satisfy different requirements.For example,LVP1 and LVP2 were equipped with a 200-ton DDIA press and a 2000-ton dual-mode(DDIA and Kawai)press,respectively.ENG1 and ENG2 provide in situ tensile,creep,and fatigue tests as well as high-temperature conditions.Since June 2023,the BL12SW has been in trial operation.It is expected to officially open to users by early 2024. 展开更多
关键词 Shanghai Synchrotron Radiation Facility Ultrahard X-ray High energy diffraction High energy imaging Engineering materials Earth science
在线阅读 下载PDF
The hard X-ray nanoprobe beamline at the SSRF
2
作者 Yan He Hui Jiang +6 位作者 dong-xu liang Zhi-Sen Jiang Huai-Na Yu Hua Wang Cheng-Wen Mao Jia-Nan Xie Ai-Guo Li 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第7期79-88,共10页
The hard X-ray nanoprobe beamline BL13U is a phase-Ⅱ beamline project at the Shanghai Synchrotron Radiation Facility.The beamline aims to enable comprehensive experiments at high spatial resolutions ranging from 50 t... The hard X-ray nanoprobe beamline BL13U is a phase-Ⅱ beamline project at the Shanghai Synchrotron Radiation Facility.The beamline aims to enable comprehensive experiments at high spatial resolutions ranging from 50 to 10 nm. The X-ray energy range of the beamline, 5–25 keV, can detect most elements in the periodic table. Two operating modes were designed to accommodate the experimental requirements of high-energy resolution or high photon flux, respectively. X-ray nanofluorescence, nanodiffraction, and coherent diffraction imaging are developed as the main experimental techniques for BL13U. This paper describes the beamline optics, end station configurations, experimental methods under development, and preliminary test results. This comprehensive overview aims to provide a clear understanding of the beamline capabilities and potential applications. 展开更多
关键词 Shanghai synchrotron radiation facility Hard X-ray nanoprobe X-ray nanofocusing
在线阅读 下载PDF
Deep learning for estimation of Kirkpatrick-Baez mirror alignment errors 被引量:1
3
作者 Jia-Nan Xie Hui Jiang +4 位作者 Ai-Guo Li Na-Xi Tian Shuai Yan dong-xu liang Jun Hu 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第8期1-11,共11页
A deep learning-based automated Kirkpatrick-Baez mirror alignment method is proposed for synchrotron radiation.We trained a convolutional neural network(CNN)on simulated and experimental imaging data of a focusing sys... A deep learning-based automated Kirkpatrick-Baez mirror alignment method is proposed for synchrotron radiation.We trained a convolutional neural network(CNN)on simulated and experimental imaging data of a focusing system.Instead of learning directly from bypass images,we use a scatterer for X-ray modulation and speckle generation for image feature enhancement.The smallest normalized root-mean-square error on the validation set was 4%.Compared with conventional alignment methods based on motor scanning and analyzer setups,the present method simplified the optical layout and estimated alignment errors using a single-exposure experiment.Single-shot misalignment error estimation only took 0.13 s,significantly outperforming conventional methods.We also demonstrated the effects of the beam quality and pretraining using experimental data.The proposed method exhibited strong robustness,can handle high-precision focusing systems with complex or dynamic wavefront errors,and provides an important basis for intelligent control of future synchrotron radiation beamlines. 展开更多
关键词 Deep learning Synchrotron radiation Optics alignment
在线阅读 下载PDF
Scan system for arbitrary-shaped samples at the synchrotron radiation facility
4
作者 Xu-Ying Lan dong-xu liang Cheng-Wen Mao 《Nuclear Science and Techniques》 SCIE CAS CSCD 2017年第5期18-27,共10页
X-ray fluorescence(XRF) scan methodology is important for elemental mapping of samples at a synchrotron radiation facility. To save the experiment time and improve the experiment efficiency, one should develop an effi... X-ray fluorescence(XRF) scan methodology is important for elemental mapping of samples at a synchrotron radiation facility. To save the experiment time and improve the experiment efficiency, one should develop an efficient XRF scan method. In this paper, a new scan mode is presented. It can map arbitrary-shaped areas withou stopping the motors. The control and data acquisition system integrates motor controlling, detector triggering, and data acquisition and storage. The system realizes the arbitrary-shaped 2D-mapping and fluorescence data acquisition synchronously. SR-XRF mapping has been performed with a standard gold mask to verify the validity of this method a beamline BL15U1 of the Shanghai Synchrotron Radiation Facility. The results show that this method reduces the tota scan time and improves the experiment efficiency. 展开更多
关键词 SYNCHROTRON radiation X-ray fluorescence mapping EPICS XPS controller
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部