Molecular imprinting technology has a great potential to be used in protein separation and purification. In this work, lysozyme imprinted polyacrylamide gel was prepared with silica particles as a sacrificial template...Molecular imprinting technology has a great potential to be used in protein separation and purification. In this work, lysozyme imprinted polyacrylamide gel was prepared with silica particles as a sacrificial template to generate macro-porosity for fast adsorption. The adsorption equilibrium time and adsorption capacity were 9 h and 56 mg/g respectively, which was 2 h less and 2.3-fold more than polymers without the sacrificial template. In order to test molecular imprinting polymers (MIPs) ' selectivity, bovine serum albumin (BSA) was chosen as interferent for binary adsorption tests. In addition, the adsorption selectivity was further investigated using different molar ratios of lysozyme to BSA with fixed total concentration of proteins, as well as using various total concentra- tions of proteins with an equimolar ratio of lysozyme to BSA. It has been proven that the total con- centration of proteins should be larger than 1.5 × 10^-7 mol/mL, when the molar ratio of BSA to Lyz is 1: 1, in order to effectively separate Lyz from the binary protein mixture. The macro-porous lyso- zyme molecularly imprinted polymers have less adsorption time, larger adsorption capacity, and bet- ter imprinting effect.展开更多
The method of reversed-phase high performance liquid chromatography was established for the determination of effective components in OC-CS spray using double wavelength UV detection.The method was utilized under follo...The method of reversed-phase high performance liquid chromatography was established for the determination of effective components in OC-CS spray using double wavelength UV detection.The method was utilized under following conditions:a column of Kromasil C18(250 mm × 4.6 mm,5 μm),mobile phase consisting of methanol/water(80 /20) at a flow rate of 0.8 mL/min,column temperature of 25 ℃,and the UV detection at 227 nm and 300 nm.Three key components in OC-CS spray could be distinguished clearly,including o-chlorobenzalmalononitrile(CS),oleoresin capsicum(OC) and dihydrocapsaicin(DC).This method has the advantages of fast,simple and satisfactory linear relationship between UV absorption and concentration.It may be considered to turn into a standard method for detection of related components in the spray.展开更多
文摘Molecular imprinting technology has a great potential to be used in protein separation and purification. In this work, lysozyme imprinted polyacrylamide gel was prepared with silica particles as a sacrificial template to generate macro-porosity for fast adsorption. The adsorption equilibrium time and adsorption capacity were 9 h and 56 mg/g respectively, which was 2 h less and 2.3-fold more than polymers without the sacrificial template. In order to test molecular imprinting polymers (MIPs) ' selectivity, bovine serum albumin (BSA) was chosen as interferent for binary adsorption tests. In addition, the adsorption selectivity was further investigated using different molar ratios of lysozyme to BSA with fixed total concentration of proteins, as well as using various total concentra- tions of proteins with an equimolar ratio of lysozyme to BSA. It has been proven that the total con- centration of proteins should be larger than 1.5 × 10^-7 mol/mL, when the molar ratio of BSA to Lyz is 1: 1, in order to effectively separate Lyz from the binary protein mixture. The macro-porous lyso- zyme molecularly imprinted polymers have less adsorption time, larger adsorption capacity, and bet- ter imprinting effect.
基金Sponsored by the Basic Research Funds of Beijing Institute of Technology (20081642007)
文摘The method of reversed-phase high performance liquid chromatography was established for the determination of effective components in OC-CS spray using double wavelength UV detection.The method was utilized under following conditions:a column of Kromasil C18(250 mm × 4.6 mm,5 μm),mobile phase consisting of methanol/water(80 /20) at a flow rate of 0.8 mL/min,column temperature of 25 ℃,and the UV detection at 227 nm and 300 nm.Three key components in OC-CS spray could be distinguished clearly,including o-chlorobenzalmalononitrile(CS),oleoresin capsicum(OC) and dihydrocapsaicin(DC).This method has the advantages of fast,simple and satisfactory linear relationship between UV absorption and concentration.It may be considered to turn into a standard method for detection of related components in the spray.