期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Preliminary clinical application of total free-breathing cardiac MR examination 被引量:3
1
作者 YANG Kai YIN Gang +4 位作者 AN Jing YANG Xinling LAN Tian ZHAO Shihua LU Minjie 《中国医学影像技术》 CSCD 北大核心 2024年第8期1183-1188,共6页
Objective To observe the clinical application value of total free-breathing cardiac MR(CMR)examination preliminarily.Methods Two patients who underwent CMR scanning under free-breathing state,including cine,motion cor... Objective To observe the clinical application value of total free-breathing cardiac MR(CMR)examination preliminarily.Methods Two patients who underwent CMR scanning under free-breathing state,including cine,motion correction T1 and T2 mapping,blood flow imaging,and late gadolinium enhancement scanning were retrospectively enrolled,and the qualities of the above images were evaluated and compared with that of conventional CMR images under breath-holding state.Results No significant difference of imaging quality was found between total free-breathing and conventional breath-holding CMR.The differences of left ventricular ejection fraction,cardiac output,left ventricular end-diastolic volume index and left ventricular mass measured based on CMR images under different breath conditions were limited.Conclusion Total free-breathing CMR was feasible in clinical practice,which could provide"one-stop"evaluation of cardiac structure,function and myocardial histological characteristics,hence having promising clinical prospects. 展开更多
关键词 HEART magnetic resonance imaging respiratory motion motion correction
在线阅读 下载PDF
探讨3T场强下的平衡式稳态自由进动序列心脏电影成像的最优偏转角
2
作者 尹刚 崔辰 +6 位作者 陆敏杰 张岩 杨新令 陈琳 纪可珊 陈瑶 赵世华 《中国循环杂志》 CSCD 北大核心 2016年第z1期-,共1页
目的:探寻3T场强下的平衡式稳态自由进动序列用于心脏电影成像的最优偏转角<br>  方法:本研究连续入选52例心脏病患者,年龄(51±13)岁。在3T 磁共振成像系统下,应用不同的偏转角(Flip Angle,FA),即30、40、50、6... 目的:探寻3T场强下的平衡式稳态自由进动序列用于心脏电影成像的最优偏转角<br>  方法:本研究连续入选52例心脏病患者,年龄(51±13)岁。在3T 磁共振成像系统下,应用不同的偏转角(Flip Angle,FA),即30、40、50、60度,用平衡式稳态自由进动序列进行心脏电影成像。测量4组图像的信号噪声比(SNR)和血池心肌对比噪声比(CNR)。图像总体质量由两名经验丰富的放射科医生来分级评分。 展开更多
在线阅读 下载PDF
运动相位纠正技术与节段法相位技术在磁共振心肌延迟增强中的对比研究 被引量:3
3
作者 樊红霞 尹刚 +2 位作者 杨新令 陆敏杰 赵世华 《中国循环杂志》 CSCD 北大核心 2017年第9期908-912,共5页
目的 :对比运动矫正相位敏感反转恢复序列(PSIR SSFP MOCO)与快速扰相梯度回波相位敏感反转恢复序列(PSIR segmented)在磁共振心肌延迟增强中的优势。方法 :回顾56例同时采用PSIR segmented(PSIR segmented组)和PSIR SSFP MOCO(PSIR SSF... 目的 :对比运动矫正相位敏感反转恢复序列(PSIR SSFP MOCO)与快速扰相梯度回波相位敏感反转恢复序列(PSIR segmented)在磁共振心肌延迟增强中的优势。方法 :回顾56例同时采用PSIR segmented(PSIR segmented组)和PSIR SSFP MOCO(PSIR SSFP MOCO组)两种扫描方式行磁共振心肌延迟增强扫描的患者的影像资料,对比分析两组图像的主观质量评分(4级),并配对对比分析两组中正常心肌、异常强化心肌及左心室腔内图像的信噪比和相对信噪比。结果 :PSIR segmented组图像质量主观评分结果:4分、3分、2分和1分组依次占28.6%、41.1%、28.6%和1.8%。PSIR SSFP MOCO组图像质量主观评分为4分的比例为96.4%,显著高于PSIR segmented组(P<0.001),3分占3.6%,1分或2分均为0%。PSIR SSFP MOCO组图像正常心肌信噪比(4.70±3.47 vs 3.64±3.2,P=0.074)、异常心肌信噪比(52.58±36.58 vs 27.65±18.47,P<0.001)及左心室血池的信噪比(40.52±33.97 vs 23.14±11.46,P<0.001)均高于PSIR segmented组。PSIR SSFP MOCO组图像异常强化心肌与正常心肌的相对信噪比(47.46±33.97 vs 23.75±16.68,P<0.001)、异常强化心肌与左心室血池的相对信噪比(8.53±17.77 vs 4.54±10.10,P=0.181)及左心室血池与正常心肌的相对信噪比(35.82±25.72 vs 19.49±9.44,P<0.001)也均显著高于PSIR segmented组。结论 :与PSIR segmented序列相比,采用PSIR SSFP MOCO序列能够获得更高比例的高质量心肌增强延迟图像。 展开更多
关键词 磁共振成像 延迟增强 心肌强化
在线阅读 下载PDF
心脏磁共振单次屏气三维容积电影成像在心脏功能评价中的应用 被引量:5
4
作者 尹刚 陈秀玉 +3 位作者 崔辰 范阳 杨新令 赵世华 《放射学实践》 北大核心 2018年第2期156-160,共5页
目的:探讨单次屏气三维(3D)平衡式稳态自由进动(bSSFP)心脏电影成像评估心脏功能方面的可行性。方法:对20例入选的心脏疾病患者进行常规心脏各切面的2DbSSFP序列和单次屏气心脏全容积3DbSSFP序列的电影成像。采集的MRI图像由2名经验丰... 目的:探讨单次屏气三维(3D)平衡式稳态自由进动(bSSFP)心脏电影成像评估心脏功能方面的可行性。方法:对20例入选的心脏疾病患者进行常规心脏各切面的2DbSSFP序列和单次屏气心脏全容积3DbSSFP序列的电影成像。采集的MRI图像由2名经验丰富的放射科医师采用双盲法进行分析。采用四分法对图像的总体质量进行等级评分(1分为最差,4分为最优),然后利用两种序列的图像,分别测量左心室舒张末容积(EDV)、收缩末容积(ESV)、每搏输出量(SV)、射血分数(EF)、心排量(CO)和心指数(CI)。依据数据的正态性分布情况,采用配对t检验或秩和检验比较两种序列的图像质量评分和心功能各项参数值,并进行Pearson相关分析或Spearman相关分析。结果:20例患者均成功完成两种序列的电影成像。3D序列扫描时间[(23.0±2.7)s]明显短于2D序列总成像时间[(488.8±27.0)s],3D和2D序列的图像质量评分分别为(2.90±0.31)和(3.55±0.60)分,差异具有统计学意义(Z=3.357,P=0.001)。剔除3例2D或3D图像质量较差有可能影响诊断的患者,对余下的17例患者进行心功能评价,2D和3D序列的心功能参数比较结果显示,EDV(t=2.519,P=0.023)和ESV(t=2.804,P=0.013)在两者间差异具有统计学意义;而SV(Z=1.254,P=0.210)、EF(t=1.728,P=0.103)、CO(Z=1.250,P=0.211)和CI(Z=0.995,P=0.320)在两者间差异无统计学意义。相关性分析显示2D和3D序列的EDV、ESV、SV、EF、CO和CI结果均高度相关(相关系数r分别为0.992、0.995、0.981、0.999、0.985和0.965,P均<0.01)。结论:相对于常规2D-bSSFP序列,单次屏气3D-bSSFP序列电影成像的图像质量虽略低,但在保证左心室功能评估的准确性的同时,大大节约CMR成像的时间成本。 展开更多
关键词 成像 三维 全心容积 单次屏气 磁共振成像 电影
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部