As the requirements of production process is getting higher and higher with the reduction of volume,microphone production automation become an urgent need to improve the production efficiency.The most important part i...As the requirements of production process is getting higher and higher with the reduction of volume,microphone production automation become an urgent need to improve the production efficiency.The most important part is studied and a precise algorithm of calculating the deviation angle of four types microphones is proposed,based on the feature extraction and visual detection.Pretreatment is performed to achieve the real-time microphone image.Canny edge detection and typical feature extraction are used to distinguish the four types of microphones,categorizing them as type M1 and type M2.And Hough transformation is used to extract the image features of microphone.Therefore,the deviation angle between the posture of microphone and the ideal posture in 2Dplane can be achieved.Depending on the angle,the system drives the motor to adjust posture of the microphone.The final purpose is to realize the high efficiency welding of four different types of microphones.展开更多
Dielectrophoresis impedance measurement(DEPIM)is a powerful tool for bioparticle detection due to its advantages of high efficiency,label-free and low costs.However,the strong electric field may decrease the viability...Dielectrophoresis impedance measurement(DEPIM)is a powerful tool for bioparticle detection due to its advantages of high efficiency,label-free and low costs.However,the strong electric field may decrease the viability of the bioparticle,thus leading to instability of impedance measurement.A new design of biochip is presented with high stable bioparticle detection capabilities by using both negative dielectrophoresis(nDEP)and traveling wave dielectrophoresis(twDEP).In the biochip,a spiral electrode is arranged on the top of channel,while a detector is arranged on the bottom of the channel.The influence factors on the DEP force and twDEP force are investigated by using the basic principle of DEP,based on which,the relationship between Clausius-Mossotti(CM)factor and the frequency of electric field is obtained.The two-dimensional model of the biochip is built by using Comsol Multiphysics.Electric potential distribution,force distribution and particle trajectory in the channel are then obtained by using the simulation model.Finally,both the simulations and experiments are performed to demonstrate that the new biochip can enhance the detection efficiency and reduce the negative effects of electric field on the bioparticles.展开更多
基金supported by the Project of Youth Fund of the National Natural Science Foundation (No. 61203208)the National Natural Science Foundation of China(No.61327802)the Specialized Research Fund for the Doctoral Program of Higher Education (No.2013320111 0009)
文摘As the requirements of production process is getting higher and higher with the reduction of volume,microphone production automation become an urgent need to improve the production efficiency.The most important part is studied and a precise algorithm of calculating the deviation angle of four types microphones is proposed,based on the feature extraction and visual detection.Pretreatment is performed to achieve the real-time microphone image.Canny edge detection and typical feature extraction are used to distinguish the four types of microphones,categorizing them as type M1 and type M2.And Hough transformation is used to extract the image features of microphone.Therefore,the deviation angle between the posture of microphone and the ideal posture in 2Dplane can be achieved.Depending on the angle,the system drives the motor to adjust posture of the microphone.The final purpose is to realize the high efficiency welding of four different types of microphones.
基金supported by the Project of Youth Fund of National Natural Science Foundation (No. 61203208)the National Natural Science Foundation of China(No.61327802)
文摘Dielectrophoresis impedance measurement(DEPIM)is a powerful tool for bioparticle detection due to its advantages of high efficiency,label-free and low costs.However,the strong electric field may decrease the viability of the bioparticle,thus leading to instability of impedance measurement.A new design of biochip is presented with high stable bioparticle detection capabilities by using both negative dielectrophoresis(nDEP)and traveling wave dielectrophoresis(twDEP).In the biochip,a spiral electrode is arranged on the top of channel,while a detector is arranged on the bottom of the channel.The influence factors on the DEP force and twDEP force are investigated by using the basic principle of DEP,based on which,the relationship between Clausius-Mossotti(CM)factor and the frequency of electric field is obtained.The two-dimensional model of the biochip is built by using Comsol Multiphysics.Electric potential distribution,force distribution and particle trajectory in the channel are then obtained by using the simulation model.Finally,both the simulations and experiments are performed to demonstrate that the new biochip can enhance the detection efficiency and reduce the negative effects of electric field on the bioparticles.