The indium activation diagnostic was calibrated using an accelerator neutron source to facilitate the diagnosis of deuterium-deuterium(DD)neutron yields of implosion experiments in the Shenguang-III facility.The sca...The indium activation diagnostic was calibrated using an accelerator neutron source to facilitate the diagnosis of deuterium-deuterium(DD)neutron yields of implosion experiments in the Shenguang-III facility.The scattered neutron background of the accelerator room was measured by placing a polypropylene shadow bar in front of the indium sample,so as to correct the calibrated factor of this activation diagnostic.The proper size of the shadow bar was given by Monte Carlo simulation.The calibration results showed that the scattered neutron background of the accelerator room was about 9%of the incident neutrons on the sample.Subtracting the portion induced by the neutron background,the calibrated factor for this sample condition was4.52×10^(-7)counts/n with an uncertainty of 4.3%.展开更多
In this work,the gas-Cherenkov detector with an off-axis parabolic reflector(Opr GCD)is designed using the Geant4 Monte Carlo simulation toolkit,which is helpful to improve the collection efficiency of Cherenkov photo...In this work,the gas-Cherenkov detector with an off-axis parabolic reflector(Opr GCD)is designed using the Geant4 Monte Carlo simulation toolkit,which is helpful to improve the collection efficiency of Cherenkov photons.The method to study the performance of Opr GCD based on femtosecond laser-wakefield-accelerated electron beams is presented.Cherenkov signals with high signal-to-noise ratio were obtained,and the measured Cherenkov signals changing with the CO2 pressure were consistent well with the simulation results.The design and study of this Opr GCD system lay the foundation for the application of fusion gamma diagnostics system in large laser facilities of China.展开更多
Low density and low convergence implosion occurs in the exploding-pusher target experiment, and generates neutrons isotropically to develop a high yield platform.In order to validate the performance of ShenGuang(SG) l...Low density and low convergence implosion occurs in the exploding-pusher target experiment, and generates neutrons isotropically to develop a high yield platform.In order to validate the performance of ShenGuang(SG) laser facility and test nuclear diagnostics, all 48-beam lasers with an on-target energy of 48 kJ were firstly used to drive room-temperature, DT gas-filled glass targets.The optimization has been carried out and optimal drive uniformity was obtained by the combination of beam repointing and target.The final irradiation uniformity of less than 5% on polar direct-drive capsules of 540 μm in diameter was achieved, and the highest thermonuclear yield of the polar direct-drive DT fuel implosion at the SG was 1.04 × 10^(13).The experiment results show neutron yields severely depend on the irradiation uniformity and laser timing,and decrease with the increase of the diameter and fuel pressure of the target.The thin CH ablator does not impact the implosion performance, but the laser drive uniformity is important.The simulated results validate that the cos γ distribution laser design is reasonable and can achieve a symmetric pressure distribution.Further optimization will focus on measuring the symmetry of the hot spot by self-emission imaging, increasing the diameter, and decreasing the fuel pressure.展开更多
A high-neutron yield platform imploded by a thin shell target is generally built to probe nuclear science problems,and it has the advantages of high neutron yield,ultrashort fusion time,micro fusion zone,isotropic and...A high-neutron yield platform imploded by a thin shell target is generally built to probe nuclear science problems,and it has the advantages of high neutron yield,ultrashort fusion time,micro fusion zone,isotropic and monoenergetic neutron.Some analytical models have been proposed to interpret exploding-pusher target implosion driven by a long wavelength laser,whereas they are imperfect for a 0.35 μm laser implosion experiment.When using the 0.35 μm laser,the shell is ablated and accelerated to high implosion velocity governed by Newton’s law,ablation acceleration and quasi-adiabatic compression models are suitable to explain the implosion of a laser direct-drive thin shell target.The new analytical model scales bang time,ion temperature and neutron yield for large variations in laser power,target radius,shell thickness,and fuel pressure.The predicted results of the analytical model are in agreement with experimental data on the ShenguangIII prototype laser facility,100 kJ laser facility,Omega,and NIF,it demonstrates that the analytical model benefits the understanding of experiment performance and optimizing the target design of high neutron yield implosion.展开更多
文摘The indium activation diagnostic was calibrated using an accelerator neutron source to facilitate the diagnosis of deuterium-deuterium(DD)neutron yields of implosion experiments in the Shenguang-III facility.The scattered neutron background of the accelerator room was measured by placing a polypropylene shadow bar in front of the indium sample,so as to correct the calibrated factor of this activation diagnostic.The proper size of the shadow bar was given by Monte Carlo simulation.The calibration results showed that the scattered neutron background of the accelerator room was about 9%of the incident neutrons on the sample.Subtracting the portion induced by the neutron background,the calibrated factor for this sample condition was4.52×10^(-7)counts/n with an uncertainty of 4.3%.
文摘In this work,the gas-Cherenkov detector with an off-axis parabolic reflector(Opr GCD)is designed using the Geant4 Monte Carlo simulation toolkit,which is helpful to improve the collection efficiency of Cherenkov photons.The method to study the performance of Opr GCD based on femtosecond laser-wakefield-accelerated electron beams is presented.Cherenkov signals with high signal-to-noise ratio were obtained,and the measured Cherenkov signals changing with the CO2 pressure were consistent well with the simulation results.The design and study of this Opr GCD system lay the foundation for the application of fusion gamma diagnostics system in large laser facilities of China.
基金Project supported by the National Natural Science Foundation of China(Grant No.11605178)the Science Challenging Project,China(Grant Nos.JCKY2016212A505 and TZ2016001)
文摘Low density and low convergence implosion occurs in the exploding-pusher target experiment, and generates neutrons isotropically to develop a high yield platform.In order to validate the performance of ShenGuang(SG) laser facility and test nuclear diagnostics, all 48-beam lasers with an on-target energy of 48 kJ were firstly used to drive room-temperature, DT gas-filled glass targets.The optimization has been carried out and optimal drive uniformity was obtained by the combination of beam repointing and target.The final irradiation uniformity of less than 5% on polar direct-drive capsules of 540 μm in diameter was achieved, and the highest thermonuclear yield of the polar direct-drive DT fuel implosion at the SG was 1.04 × 10^(13).The experiment results show neutron yields severely depend on the irradiation uniformity and laser timing,and decrease with the increase of the diameter and fuel pressure of the target.The thin CH ablator does not impact the implosion performance, but the laser drive uniformity is important.The simulated results validate that the cos γ distribution laser design is reasonable and can achieve a symmetric pressure distribution.Further optimization will focus on measuring the symmetry of the hot spot by self-emission imaging, increasing the diameter, and decreasing the fuel pressure.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11775203 and 12075219)the Innovation and Development Fund of China Academy of Engineering Physics(Grant No.CX20210019)。
文摘A high-neutron yield platform imploded by a thin shell target is generally built to probe nuclear science problems,and it has the advantages of high neutron yield,ultrashort fusion time,micro fusion zone,isotropic and monoenergetic neutron.Some analytical models have been proposed to interpret exploding-pusher target implosion driven by a long wavelength laser,whereas they are imperfect for a 0.35 μm laser implosion experiment.When using the 0.35 μm laser,the shell is ablated and accelerated to high implosion velocity governed by Newton’s law,ablation acceleration and quasi-adiabatic compression models are suitable to explain the implosion of a laser direct-drive thin shell target.The new analytical model scales bang time,ion temperature and neutron yield for large variations in laser power,target radius,shell thickness,and fuel pressure.The predicted results of the analytical model are in agreement with experimental data on the ShenguangIII prototype laser facility,100 kJ laser facility,Omega,and NIF,it demonstrates that the analytical model benefits the understanding of experiment performance and optimizing the target design of high neutron yield implosion.