An experimental set up was designed to separately test how sedimentation and convection driven flows affect the perikinetic coagulation process in a ground based experiment.The experiment showed that the sedimentation...An experimental set up was designed to separately test how sedimentation and convection driven flows affect the perikinetic coagulation process in a ground based experiment.The experiment showed that the sedimentation slightly accelerates the coagulation process and weak free convection driven flows do not noticeably contribute to coagulation for 2 μm particles’ dispersion.展开更多
Pure liquid-liquid diffusion driven by concentration gradients is hard to study in a normal gravity environment since convection and sedimentation also contribute to the mass transfer process. We employ a Math Zehnder...Pure liquid-liquid diffusion driven by concentration gradients is hard to study in a normal gravity environment since convection and sedimentation also contribute to the mass transfer process. We employ a Math Zehnder interferometer to monitor the mass transfer process of a water droplet in EAFP protein solution under micro- gravity condition provided by the Satellite Shi Jian No 8, A series of the evolution charts of mass distribution during the diffusion process of the liquid droplet are presented and the relevant diffusion coefficient is determined.展开更多
The extinction cross sections of a system containing two particles are calculated by the T-matrix method, and the results are compared with those of two single particles with single-scattering approximation. The neces...The extinction cross sections of a system containing two particles are calculated by the T-matrix method, and the results are compared with those of two single particles with single-scattering approximation. The necessity of the correction of the refractive indices of water and polystyrene for different incident wavelengths is particularly addressed in the calculation. By this means, the volume fractions allowed for certain accuracy requirements of single-scattering approximation in the light scattering experiment can be evaluated. The volume fractions calculated with corrected refractive indices are compared with those obtained with fixed refractive indices which have been rather commonly used, showing that fixed refractive indices may cause significant error in evaluating multiple scattering effect. The results also give a simple criterion for selecting the incident wavelength and particle size to avoid the 'blind zone' in the turbidity measurement, where the turbidity change is insensitive to aggregation of two particles.展开更多
The method of density matching between the solid and liquid phases is often adopted to effectively eliminate the effect of sedimentation of suspensions in studies on dynamic behaviour of a colloidal system. However, t...The method of density matching between the solid and liquid phases is often adopted to effectively eliminate the effect of sedimentation of suspensions in studies on dynamic behaviour of a colloidal system. However, the associated changes in the solvent composition may bring side effects to the properties investigated and therefore might lead to a faulty conclusion if the relevant correction is not made. To illustrate the importance of this side effect, we present an example of the sedimentation influence on the coagulation rate of suspensions of 2μm (diameter) polystyrene. The liquid mixtures, in the proper proportions of water (H2O), deuterium oxide (D2O) and methanol (MeOH) as the liquid phase, density-matched and unmatched experiments are performed. Besides the influence of viscosity, the presence of methanol in solvent media, used to enhance the sedimentation effect, causes significant changes (reduction) in rapid coagulation rates compared to that in pure water. Without the relevant corrections for those non-gravitational factors it seems that gravitational sedimentation would retard the coagulation. The magnitude of the contribution from the non-gravitational factor is quantitatively determined, making the relevant correction possible. After necessary the influence of the sedimentation on coagulation rates at corrections for all factors, our experiments show that the initial stage of the coagulation is not observable.展开更多
Simultaneous orthokinetic and perikinetic coagulations(SOPCs) are studied for small and large Peclet numbers(P e) using Brownian dynamics simulation.The results demonstrate that the contributions of the Brownian m...Simultaneous orthokinetic and perikinetic coagulations(SOPCs) are studied for small and large Peclet numbers(P e) using Brownian dynamics simulation.The results demonstrate that the contributions of the Brownian motion and the shear flow to the overall coagulation rate are basically not additive.At the early stages of coagulation with small Peclet numbers,the ratio of overall coagulation rate to the rate of pure perikinetic coagulation is proportional to P 1/2 e,while with high Peclet numbers,the ratio of overall coagulation rate to the rate of pure orthokinetic coagulation is proportional to P 1/2 e.Moreover,our results show that the aggregation rate generally changes with time for the SOPC,which is different from that for pure perikinetic and pure orthokinetic coagulations.By comparing the SOPC with pure perikinetic and pure orthokinetic coagulations,we show that the redistribution of particles due to Brownian motion can play a very important role in the SOPC.In addition,the effects of redistribution in the directions perpendicular and parallel to the shear flow direction are different.This perspective explains the behavior of coagulation due to the joint effects of the Brownian motion(perikinetic) and the fluid motion(orthokinetic).展开更多
文摘An experimental set up was designed to separately test how sedimentation and convection driven flows affect the perikinetic coagulation process in a ground based experiment.The experiment showed that the sedimentation slightly accelerates the coagulation process and weak free convection driven flows do not noticeably contribute to coagulation for 2 μm particles’ dispersion.
文摘Pure liquid-liquid diffusion driven by concentration gradients is hard to study in a normal gravity environment since convection and sedimentation also contribute to the mass transfer process. We employ a Math Zehnder interferometer to monitor the mass transfer process of a water droplet in EAFP protein solution under micro- gravity condition provided by the Satellite Shi Jian No 8, A series of the evolution charts of mass distribution during the diffusion process of the liquid droplet are presented and the relevant diffusion coefficient is determined.
基金Supported by the National Natural Science Foundation of China under Grand Nos 10672173 and 10332050, and the China Postdoctoral Science Foundation.
文摘The extinction cross sections of a system containing two particles are calculated by the T-matrix method, and the results are compared with those of two single particles with single-scattering approximation. The necessity of the correction of the refractive indices of water and polystyrene for different incident wavelengths is particularly addressed in the calculation. By this means, the volume fractions allowed for certain accuracy requirements of single-scattering approximation in the light scattering experiment can be evaluated. The volume fractions calculated with corrected refractive indices are compared with those obtained with fixed refractive indices which have been rather commonly used, showing that fixed refractive indices may cause significant error in evaluating multiple scattering effect. The results also give a simple criterion for selecting the incident wavelength and particle size to avoid the 'blind zone' in the turbidity measurement, where the turbidity change is insensitive to aggregation of two particles.
基金Supported by the National Natural Science Foundation of China under Grant Nos 20473108 and 10332050, and the Knowledge Innovation Program of Chinese Academy of Sciences.
文摘The method of density matching between the solid and liquid phases is often adopted to effectively eliminate the effect of sedimentation of suspensions in studies on dynamic behaviour of a colloidal system. However, the associated changes in the solvent composition may bring side effects to the properties investigated and therefore might lead to a faulty conclusion if the relevant correction is not made. To illustrate the importance of this side effect, we present an example of the sedimentation influence on the coagulation rate of suspensions of 2μm (diameter) polystyrene. The liquid mixtures, in the proper proportions of water (H2O), deuterium oxide (D2O) and methanol (MeOH) as the liquid phase, density-matched and unmatched experiments are performed. Besides the influence of viscosity, the presence of methanol in solvent media, used to enhance the sedimentation effect, causes significant changes (reduction) in rapid coagulation rates compared to that in pure water. Without the relevant corrections for those non-gravitational factors it seems that gravitational sedimentation would retard the coagulation. The magnitude of the contribution from the non-gravitational factor is quantitatively determined, making the relevant correction possible. After necessary the influence of the sedimentation on coagulation rates at corrections for all factors, our experiments show that the initial stage of the coagulation is not observable.
基金Project supported by the National Natural Science Foundation of China (Grant Nos. 10972217,10932012 and 11032011)the Knowledge Innovation Program of the Chinese Academy of Sciences (Grant No. KJCX2-YW-L08)
文摘Simultaneous orthokinetic and perikinetic coagulations(SOPCs) are studied for small and large Peclet numbers(P e) using Brownian dynamics simulation.The results demonstrate that the contributions of the Brownian motion and the shear flow to the overall coagulation rate are basically not additive.At the early stages of coagulation with small Peclet numbers,the ratio of overall coagulation rate to the rate of pure perikinetic coagulation is proportional to P 1/2 e,while with high Peclet numbers,the ratio of overall coagulation rate to the rate of pure orthokinetic coagulation is proportional to P 1/2 e.Moreover,our results show that the aggregation rate generally changes with time for the SOPC,which is different from that for pure perikinetic and pure orthokinetic coagulations.By comparing the SOPC with pure perikinetic and pure orthokinetic coagulations,we show that the redistribution of particles due to Brownian motion can play a very important role in the SOPC.In addition,the effects of redistribution in the directions perpendicular and parallel to the shear flow direction are different.This perspective explains the behavior of coagulation due to the joint effects of the Brownian motion(perikinetic) and the fluid motion(orthokinetic).