The self-excited vibration problems of maglev vehicle-bridge interaction system were addressed, which greatly degrades the stability of the levitation control, decreases the ride comfort, and restricts the cost of the...The self-excited vibration problems of maglev vehicle-bridge interaction system were addressed, which greatly degrades the stability of the levitation control, decreases the ride comfort, and restricts the cost of the whole system. Firstly, the coupled model containing the quintessential parts was built, and the mechanism of self-excited vibration was explained in terms of energy transmission from levitation system to bridge. Then, the influences of the parameters of the widely used integral-type proportion and derivation(PD) controller and the delay of signals on the stability of the interaction system were analyzed. The result shows that the integral-type PD control is a nonoptimal approach to solve the self-excited vibration completely. Furthermore, the differential-type PD controller can guarantee the passivity of levitation system at full band. However, the differentiation of levitation gap should be filtered by a low-pass filter due to noise of gap differentiation. The analysis indicates that a well tuned low-pass filter can still keep the coupled system stable.展开更多
This work addresses the problem of self-excited vibration,which degrades the stability of the levitation control,decreases the ride comfort,and restricts the construction cost of maglev system.Firstly,a minimum model ...This work addresses the problem of self-excited vibration,which degrades the stability of the levitation control,decreases the ride comfort,and restricts the construction cost of maglev system.Firstly,a minimum model containing a flexible bridge and a single levitation unit is presented.Based on the simplified model,the principle underlying the self-excited vibration is explored.After investigations about the energy transmission between the levitation system and bridge,it is concluded that the increment of modal damping can dissipate the accumulated energy by the bridge and the self-excited vibration may be avoided.To enlarge the equivalent modal damping of bridge,the sky-hooked damper is adopted.Furthermore,to avoid the hardware addition of real sky-hooked damper,considering the fact that the electromagnet itself is an excellent actuator that is capable of providing sufficiently fast and large force acting on the bridge to emulate the influence of the real sky-hooked damper,the technique of the virtual sky-hooked damper is proposed.The principle underlying the virtual sky-hooked damper by electromagnet is explored and the vertical velocity of bridge is estimated.Finally,numerical and experimental results illustrating the stability improvement of the vehicle-bridge interaction system are provided.展开更多
The application of new-designed levitation controller requires extensive validation prior to enter into commercial service. However, huge mounts of approximations and assumptions lead the theoretical analysis away fro...The application of new-designed levitation controller requires extensive validation prior to enter into commercial service. However, huge mounts of approximations and assumptions lead the theoretical analysis away from the engineering practice. The experimental methods are time-consuming and financial expensive, even unrealizable due to the lack of suitable sensors. Numerical simulations can bridge the gap between the theoretical analysis and experimental techniques. A complete overall dynamic model of maglev levitation system is derived in this work, which includes the simple-supported bridges, the calculation of electromagnetic force with more details, the stress of levitation modules and the cabin. Based on the aforementioned model, it shows that the inherent nonlinearity, inner coupling, misalignments between the sensors and actuators, and self-excited vibration are the main issues that should be considered during the design process of controller. Then, the backstepping controller based on the mathematical model of the module with reasonable simplifications is proposed, and the stability proofs are listed. To show the advantage of controller, two numerical simulation experiments are carried out. Finally, the results illustrating closed-loop performance are provided.展开更多
基金Projects(60404003,11202230)supported by the National Natural Science Foundation of China
文摘The self-excited vibration problems of maglev vehicle-bridge interaction system were addressed, which greatly degrades the stability of the levitation control, decreases the ride comfort, and restricts the cost of the whole system. Firstly, the coupled model containing the quintessential parts was built, and the mechanism of self-excited vibration was explained in terms of energy transmission from levitation system to bridge. Then, the influences of the parameters of the widely used integral-type proportion and derivation(PD) controller and the delay of signals on the stability of the interaction system were analyzed. The result shows that the integral-type PD control is a nonoptimal approach to solve the self-excited vibration completely. Furthermore, the differential-type PD controller can guarantee the passivity of levitation system at full band. However, the differentiation of levitation gap should be filtered by a low-pass filter due to noise of gap differentiation. The analysis indicates that a well tuned low-pass filter can still keep the coupled system stable.
基金Projects(11302252,11202230) supported by the National Natural Science Foundation of China
文摘This work addresses the problem of self-excited vibration,which degrades the stability of the levitation control,decreases the ride comfort,and restricts the construction cost of maglev system.Firstly,a minimum model containing a flexible bridge and a single levitation unit is presented.Based on the simplified model,the principle underlying the self-excited vibration is explored.After investigations about the energy transmission between the levitation system and bridge,it is concluded that the increment of modal damping can dissipate the accumulated energy by the bridge and the self-excited vibration may be avoided.To enlarge the equivalent modal damping of bridge,the sky-hooked damper is adopted.Furthermore,to avoid the hardware addition of real sky-hooked damper,considering the fact that the electromagnet itself is an excellent actuator that is capable of providing sufficiently fast and large force acting on the bridge to emulate the influence of the real sky-hooked damper,the technique of the virtual sky-hooked damper is proposed.The principle underlying the virtual sky-hooked damper by electromagnet is explored and the vertical velocity of bridge is estimated.Finally,numerical and experimental results illustrating the stability improvement of the vehicle-bridge interaction system are provided.
基金Projects(60404003,11202230)supported by the National Natural Science Foundation of China
文摘The application of new-designed levitation controller requires extensive validation prior to enter into commercial service. However, huge mounts of approximations and assumptions lead the theoretical analysis away from the engineering practice. The experimental methods are time-consuming and financial expensive, even unrealizable due to the lack of suitable sensors. Numerical simulations can bridge the gap between the theoretical analysis and experimental techniques. A complete overall dynamic model of maglev levitation system is derived in this work, which includes the simple-supported bridges, the calculation of electromagnetic force with more details, the stress of levitation modules and the cabin. Based on the aforementioned model, it shows that the inherent nonlinearity, inner coupling, misalignments between the sensors and actuators, and self-excited vibration are the main issues that should be considered during the design process of controller. Then, the backstepping controller based on the mathematical model of the module with reasonable simplifications is proposed, and the stability proofs are listed. To show the advantage of controller, two numerical simulation experiments are carried out. Finally, the results illustrating closed-loop performance are provided.