期刊文献+
共找到8篇文章
< 1 >
每页显示 20 50 100
Detection of the spatiotemporal field of a single-shot terahertz pulse based on spectral holography 被引量:1
1
作者 王晓雷 费扬 +2 位作者 李璐杰 王强 朱竹青 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第6期212-216,共5页
According to electro-optical sampling theory, we propose a new method to detect the spatiotemporal field of a single- shot terahertz pulse by spectral holography for the first time. The single-shot terahertz pulse is ... According to electro-optical sampling theory, we propose a new method to detect the spatiotemporal field of a single- shot terahertz pulse by spectral holography for the first time. The single-shot terahertz pulse is coupled into a broadened chirped femtosecond pulse according to electro-optical sampling theory in the detecting system. Then the reference wave and the signal wave are split by Dammann grating and spread into the interference band-pass filter. The filtered sub-waves are at different central-frequencies because of the different incident angles. These sub-waves at different central-frequencies interfere to form sub-holograms, which are recorded in a single frame of a charge coupled device (CCD). The sub-holograms are numerically processed, and the spatiotemporal field distribution of the original terahertz pulse is reconstructed. The computer simulations verify the feasibility of the proposed method. 展开更多
关键词 spatiotemporal field of single-shot terahertz pulse Dammann grating interference band-pass filter spectral holography
在线阅读 下载PDF
New terahertz dispersive device for single-shot spectral measurements of terahertz pulse
2
作者 巫殷忠 赵宗清 +2 位作者 谷渝秋 魏来 曹磊峰 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第12期329-332,共4页
A new terahertz dispersive device designed for single-shot spectral measurements of broadband terahertz pulses is proposed. With two-dimensional quasi-randomly distributed element design, the device exhibits approxima... A new terahertz dispersive device designed for single-shot spectral measurements of broadband terahertz pulses is proposed. With two-dimensional quasi-randomly distributed element design, the device exhibits approximately the dispersive property of single-order diffraction in far field. Its far-field diffraction pattern is experimentally verified employing a continuous terahertz source centered at 2.52 THz and a pyroelectric focal-plane-array camera, which is in good agreement with the numerical result. The device provides a new approach for direct single-shot spectral measurements of broadband terahertz waves. 展开更多
关键词 TERAHERTZ DIFFRACTION single-shot spectral measurement
在线阅读 下载PDF
Single-shot grating-based x-ray differential phase contrast imaging with a modified analyzer grating
3
作者 卫晨希 吴朝 +6 位作者 Faiz Wali 魏文彬 鲍园 骆荣辉 王磊 刘刚 田扬超 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第10期501-507,共7页
X-ray grating interferometer has attracted widely attention in the past years due to its capability in achieving x-ray phase contrast imaging with low brilliance source. However, the widely used phase stepping informa... X-ray grating interferometer has attracted widely attention in the past years due to its capability in achieving x-ray phase contrast imaging with low brilliance source. However, the widely used phase stepping information extraction method reduces system stability and prolongs data acquisition time by several times compared with conventional x-ray absorption- based imaging. The mechanical stepping can be avoided by using a staggered grating, but at the cost of low vertical spatial resolution. In this paper, employing a modified staggered grating and the angular signal radiography, we proposed a single-shot grating-based x-ray differential phase contrast imaging with decent vertical spatial resolution. The theoretical framework was deduced and proved by numerical experiments. Absorption, phase, and scattering computed tomography can be performed without phase stepping. Therefore, we believe this fast and highly stable imaging method with decent resolution would be widely applied in x-ray grating-based phase contrast imaging. 展开更多
关键词 x-ray phase contrast imaging single-shot decent resolution staggered grating computed tomography
在线阅读 下载PDF
Single-shot measurement of THz pulses
4
作者 Lei Yang Lei Hou +1 位作者 Chengang Dong Wei Shi 《Chinese Physics B》 SCIE EI CAS CSCD 2020年第5期37-40,共4页
Terahertz(THz) waves have shown a broad prospect in the analysis of some dielectric materials because of their special properties. For the ultrafast irreversible processes, the THz single-shot measurement is a good ch... Terahertz(THz) waves have shown a broad prospect in the analysis of some dielectric materials because of their special properties. For the ultrafast irreversible processes, the THz single-shot measurement is a good choice. In this paper,a single-shot system is investigated, where a pump beam is used to generate THz pulses with high electrical field by optical rectification in LiNbO3, the probe beam with wavefront tilted by a blazed grating is used for single-shot measurement. The time window is up to 90 ps, the signal to noise ratio is 2000 : 1, the spectrum covers from 0.1 THz to about 2.0 THz, and the spectral resolution is 0.011 THz. The single-shot measurement result agrees well with that of a traditional electrical-optic sampling method. 展开更多
关键词 terahertz waves tilted wavefront single-shot measurement
在线阅读 下载PDF
Single-Shot 360-Degree Cranial Deformity Detection System Using Digital Image Correlation
5
作者 Shaogang Liu Long Yin +2 位作者 Wei Yin Yuzhen Zhang Chao Zuo 《Journal of Beijing Institute of Technology》 EI CAS 2022年第2期131-139,共9页
In this paper,a single-shot 360-degree cranial deformity detection system using digital image correlation(DIC)is presented to quickly obtain and detect accurate 3D data of infants’cra-nium.By introducing plane mirror... In this paper,a single-shot 360-degree cranial deformity detection system using digital image correlation(DIC)is presented to quickly obtain and detect accurate 3D data of infants’cra-nium.By introducing plane mirrors into a stereo 3D DIC measurement system,a multi-view 3D imaging model is established to convert 3D data from real and virtual perspectives into 360-degree 3D data of the tested infant cranium,achieving single-shot and panoramic 3D measurement.Exper-imental results showed that the performance and measurement accuracy of the proposed system can meet the requirements for cranial deformity detection,which provides a fast,accurate,and low-cost solution medically. 展开更多
关键词 single-shot measurement 360-degree measurement cranial deformity detection
在线阅读 下载PDF
Single-Shot Measurement of Transient Phase Shift Induced by Laser Wake
6
作者 董军 卢宗贵 +8 位作者 张波 彭志涛 孙志红 夏彦文 元浩宇 唐军 朱德燕 刘华 吕嘉坤 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第5期60-62,共3页
Based on the frequency-to-time mapping relation of the linearly chirped pulse, the temporal phase shift induced by a laser-excited wake in a helium gas jet is measured using a chirped-pulse spectral interferometry wi... Based on the frequency-to-time mapping relation of the linearly chirped pulse, the temporal phase shift induced by a laser-excited wake in a helium gas jet is measured using a chirped-pulse spectral interferometry with ~ 140 fs resolution over a temporal region of I ps in a single shot. In this measurement, the image of the wake is obtained with one-dimensional spatial resolution and temporal resolution limited only by the bandwidth and chirp of the pulse. The 'bubbles' feature of the wake structure, along with multiple wakes excited by the main lobe and the side lobe of a laser focal-spot, is captured simultaneously. 展开更多
关键词 single-shot Measurement of Transient Phase Shift Induced by Laser Wake
在线阅读 下载PDF
First commissioning results of the coherent scattering and imaging endstation at the Shanghai soft X-ray free-electron laser facility 被引量:4
7
作者 Jia-Dong Fan Ya-Jun Tong +17 位作者 Yong-Gan Nie Zi-Chen Gao Bo He Hui Luan Dong-Hao Lu Jian-Hua Zhang Di-Fei Zhang Xin-Ye Yuan Jia-Hua Chen Zhi Guo Tao Liu Meng Zhang Chao Feng Hai-Xiao Deng Bo Liu Zhen-Tang Zhao Zhi Liu Huai-Dong Jiang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2022年第9期48-58,共11页
The Shanghai soft X-ray free-electron laser(SXFEL)user facility project started in 2016 and is expected to be open to users by 2022.It aims to deliver ultra-intense coherent femtosecond X-ray pulses to five endstation... The Shanghai soft X-ray free-electron laser(SXFEL)user facility project started in 2016 and is expected to be open to users by 2022.It aims to deliver ultra-intense coherent femtosecond X-ray pulses to five endstations covering a range of 100–620 eV for ultrafast X-ray science.Two undulator lines are designed and constructed,based on different lasing modes:self-amplified spontaneous emission and echo-enabled harmonic generation.The coherent scattering and imaging(CSI)endstation is the first of five endstations to be commissioned online.It focuses on high-resolution single-shot imaging and the study of ultrafast dynamic processes using coherent forward scattering techniques.Both the single-shot holograms and coherent diffraction patterns were recorded and reconstructed for nanoscale imaging,indicating the excellent coherence and high peak power of the SXFEL and the possibility of‘‘diffraction before destruction’’experiments at the CSI endstation.In this study,we report the first commissioning results of the CSI endstation. 展开更多
关键词 X-ray free electron laser Coherent diffraction imaging Fourier transform holography single-shot imaging Phase retrieval
在线阅读 下载PDF
A high-precision and 10 bit two-step Time-to-Digital Converter for TOF application
8
作者 YE Xuefeng TANG Lizhen +3 位作者 WANG Yang JIN Xiangliang PENG Yan LUO Jun 《太赫兹科学与电子信息学报》 2021年第3期528-536,共9页
A two-step high-precision Time-to-Digital Converter(TDC),integrated with a Single-Photon Avalanche Diode(SPAD),used for Time-Of-Flight(TOF)application,has been developed and tested.Time interval measurement is perform... A two-step high-precision Time-to-Digital Converter(TDC),integrated with a Single-Photon Avalanche Diode(SPAD),used for Time-Of-Flight(TOF)application,has been developed and tested.Time interval measurement is performed by the coarse counter and fine interpolator,which are utilized to measure the total periods and the residue time of the reference clock,respectively.Following a detail analysis of time precision and clock jitter in the two-step structure,the prototype TDC fabricated in GSMC 1P6M 0.18μm CMOS Image Sensor(CIS)technology exhibits a Single-Shot Precision(SSP)of 11.415 ps and a dynamic range of 216.7 ns.In addition,a pixel of the chip occupies 100μm×100μm,and the measured Integral Nonlinearity(INL)and Differential Nonlinearity(DNL)are better than±0.88 LSB and±0.67 LSB,respectively.Meanwhile,the overall power consumption of the chip is 35 mW at 1.8 V power supply.Combined with these characteristics,the designed chip is suitable for TOF-based ranging applications. 展开更多
关键词 Time-to-Digital Converter single-shot Precision non-linearity TIME-OF-FLIGHT coarse counter fine interpolator
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部