期刊文献+
共找到4,221篇文章
< 1 2 212 >
每页显示 20 50 100
Numerical design of transverse gradient coil with transformed magnetic gradient field over an effective imaging area
1
作者 Chaoqun Niu Hongyi Qu 《Magnetic Resonance Letters》 2025年第1期40-51,共12页
Gradient coil is an essential component of a magnetic resonance imaging(MRI)scanner.To achieve high spatial resolution and imaging speed,a high-efficiency gradient coil with high slew rate is required.In consideration... Gradient coil is an essential component of a magnetic resonance imaging(MRI)scanner.To achieve high spatial resolution and imaging speed,a high-efficiency gradient coil with high slew rate is required.In consideration of the safety and comfort of the patient,the mechanical stability,acoustic noise and peripheral nerve stimulation(PNS)are also need to be concerned for practical use.In our previous work,a high-efficiency whole-body gradient coil set with a hybrid cylindrical-planar structure has been presented,which offers significantly improved coil performances.In this work,we propose to design this transverse gradient coil system with transformed magnetic gradient fields.By shifting up the zero point of gradient fields,the designed new Y-gradient coil could provide enhanced electromagnetic performances.With more uniform coil winding arrangement,the net torque of the new coil is significantly reduced and the generated sound pressure level(SPL)is lower at most tested frequency bands.On the other hand,the new transverse gradient coil designed with rotated magnetic gradient fields produces considerably reduced electric field in the human body,which is important for the use of rapid MR sequences.It's demonstrated that a safer and patient-friendly design could be obtained by using transformed magnetic gradient fields,which is critical for practical use. 展开更多
关键词 Magnetic resonance imaging(MRI) Gradient coil Transformed magnetic gradient field Acoustic noise Induced electric field
在线阅读 下载PDF
Gradient coil design with enhanced shielding constraint for a cryogen-free superconducting MRI system 被引量:1
2
作者 Yaohui Wang Weimin Wang +3 位作者 Hui Liu Shunzhong Chen Feng Liu Qiuliang Wang 《Magnetic Resonance Letters》 2024年第1期1-9,共9页
The relatively fragile low-temperature stability of cryogen-free superconducting magnetic resonance imaging(MRI)magnets requires the careful management of exogenous heat sources.A strongly shielded gradient magnetic f... The relatively fragile low-temperature stability of cryogen-free superconducting magnetic resonance imaging(MRI)magnets requires the careful management of exogenous heat sources.A strongly shielded gradient magnetic field is important for the optimal operation of cryogen-free MRI systems.In this study,we present an enhanced shielding method incorporating a regionalized stray field constraining strategy.By optimizing the constraint parameters,we could develop engineering-feasible gradient coil schemes without increasing system complexity but with the stray field intensity reduced by half.In real measurement in an integrated MRI system,the developed gradient assembly demonstrated good performance and supported to output images of excellent quality.Our findings suggested that the proposed method could potentially form a useful design paradigm for cryogen-free MRI magnets. 展开更多
关键词 MRI Gradient coil Superconducting magnet Cryogen-free Magnetic shielding
在线阅读 下载PDF
Enhancing silicon spectral emission in LIBS using Tesla coil discharge
3
作者 Shuang CUI Yang LIU +1 位作者 Anmin CHEN Mingxing JIN 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第12期132-139,共8页
Laser-induced breakdown spectroscopy(LIBS)is a powerful technique for elemental analysis,offering rapid analysis,minimal sample preparation,wide elemental coverage,and portability.To enhance the detection sensitivity ... Laser-induced breakdown spectroscopy(LIBS)is a powerful technique for elemental analysis,offering rapid analysis,minimal sample preparation,wide elemental coverage,and portability.To enhance the detection sensitivity of LIBS,increasing the spectral emission intensity is crucial.This paper explores the use of Tesla coil(TC)discharge as an alternative to spark discharge in silicon LIBS.The study examines the influence of TC discharge on both time-integrated and timeresolved spectra,with and without TC discharge;the corresponding electron temperature and density are obtained.The results show that TC discharge significantly amplifies the spectral intensity,improving signal sensitivity in LIBS analysis.Specifically,in the laser energy range from 7.4 to 24.0 mJ,TC discharge increased the average spectral line intensities of Si(II)385.60 nm and Si(I)390.55 nm by factors of 8.4 and 5.1,respectively.Additionally,the average electron temperature and density were enhanced by approximately 3.2%and 4.2%,respectively,under TC discharge.The advantages of TC discharge include higher energy deposition,extended discharge duration,reduced electrode erosion,and enhanced safety.This research contributes to advancing LIBS technology and expanding its applications in various fields. 展开更多
关键词 LIBS Tesla coil spectral enhancement SILICON
在线阅读 下载PDF
Analytical computation of magnetic field in coil-dominated superconducting quadrupole magnets based on racetrack coils
4
作者 Chuang Shen Ying-Shun Zhu Fu-San Chen 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第4期119-135,共17页
Currently,three types of superconducting quadrupole magnets are used in particle accelerators:cos 2θ,CCT,and serpentine.However,all three coil configurations have complex spatial geometries,which make magnet manufact... Currently,three types of superconducting quadrupole magnets are used in particle accelerators:cos 2θ,CCT,and serpentine.However,all three coil configurations have complex spatial geometries,which make magnet manufacturing and strain-sensitive superconductor applications difficult.Compared with the three existing quadrupole coils,the racetrack quadrupole coil has a simple shape and manufacturing process,but there have been few theoretical studies.In this paper,the two-dimensional and three-dimensional analytical expressions for the magnetic field in coil-dominated racetrack superconducting quadrupole magnets are presented.The analytical expressions of the field harmonics and gradient are fully resolved and depend only on the geometric parameters of the coil and current density.Then,a genetic algorithm is applied to obtain a solution for the coil geometry parameters with field harmonics on the order of 10^(-4).Finally,considering the practical engineering needs of the accelerator interaction region,electromagnetic design examples of racetrack quadrupole magnets with high gradients,large apertures,and small apertures are described,and the application prospects of racetrack quadrupole coils are analyzed. 展开更多
关键词 Superconducting quadrupole magnet Racetrack coil Multipole field Genetic algorithm Magnetic design
在线阅读 下载PDF
Effect of coil and chamber structure on plasma radial uniformity in radio frequency inductively coupled plasma
5
作者 赵洋 周晓华 +2 位作者 高升荣 宋莎莎 赵玉真 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第7期58-66,共9页
Enhancing plasma uniformity can be achieved by modifying coil and chamber structures in radio frequency inductively coupled plasma(ICP)to meet the demand for large-area and uniformly distributed plasma in industrial m... Enhancing plasma uniformity can be achieved by modifying coil and chamber structures in radio frequency inductively coupled plasma(ICP)to meet the demand for large-area and uniformly distributed plasma in industrial manufacturing.This study utilized a two-dimensional self-consistent fluid model to investigate how different coil configurations and chamber aspect ratios affect the radial uniformity of plasma in radio frequency ICP.The findings indicate that optimizing the radial spacing of the coil enhances plasma uniformity but with a reduction in electron density.Furthermore,optimizing the coil within the ICP reactor,using the interior point method in the Interior Point Optimizer significantly enhances plasma uniformity,elevating it from 56%to 96%within the range of the model sizes.Additionally,when the chamber aspect ratio k changes from 2.8 to 4.7,the plasma distribution changes from a center-high to a saddleshaped distribution.Moreover,the plasma uniformity becomes worse.Finally,adjusting process parameters,such as increasing source power and gas pressure,can enhance plasma uniformity.These findings contribute to optimizing the etching process by improving plasma radial uniformity. 展开更多
关键词 inductively coupled plasma fluid simulation optimized coil chamber aspect ratio plasma uniformity
在线阅读 下载PDF
Realization of an optimized cylindrical uniform magnetic field coil via flexible printed circuit technology
6
作者 A-Hui Zhao Yong-Le Zhang +5 位作者 Yue-Yue Liang Yi Zhang Jun-Jun Zha Dao-Rong Rui Xiao-Qiang Zhang Kang Yang 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第12期242-248,共7页
The design and fabrication method of magnetic field coils with high uniformity is essential for atomic magnetometers.In this paper,a novel design strategy for cylindrical uniform coils is first proposed,which combines... The design and fabrication method of magnetic field coils with high uniformity is essential for atomic magnetometers.In this paper,a novel design strategy for cylindrical uniform coils is first proposed,which combines the target-field method(TFM)with an optimized slime mold algorithm(SMA)to determine optimal structure parameters.Then,the realization method for the designed cylindrical coil by using the flexible printed circuit(FPC)technology is presented.Compared with traditional fabrication methods,this method has advantages in excellent flexibility and bending property,making the coils easier to be arranged in limited space.Moreover,the manufacturing process of the FPC technology via a specific cylindrical uniform magnetic field coil is discussed in detail,and the successfully realized coil is well tested in a verification system.By comparing the uniformity performance of the experimental coil with the simulation one,the effectiveness of the FPC technology in producing cylindrical coils has been well validated. 展开更多
关键词 uniform magnetic field coil optimized target field method slime mold algorithm FPC technology
在线阅读 下载PDF
螺旋管式蒸汽发生器管束流体弹性不稳定性机理研究
7
作者 王越 谭蔚 《原子能科学技术》 北大核心 2025年第3期607-615,共9页
螺旋管束由于其结构紧凑、传热效率高等特点广泛应用于快堆与第4代核电堆型中。为揭示螺旋管束流体弹性不稳定性,本文在验证激振模型的冲击实验基础上,利用螺旋管束激振模型系统地研究了管的相对位置、管束结构参数对螺旋管振动响应的... 螺旋管束由于其结构紧凑、传热效率高等特点广泛应用于快堆与第4代核电堆型中。为揭示螺旋管束流体弹性不稳定性,本文在验证激振模型的冲击实验基础上,利用螺旋管束激振模型系统地研究了管的相对位置、管束结构参数对螺旋管振动响应的作用机制。研究发现面外方向的振幅远大于面内方向的,相邻管层节径比对螺旋管振动响应的影响强于同层管间节径比与螺旋角。通过改变管间流速,探究了螺旋管束流体弹性不稳定性机理,提出了预测临界流速的半经验公式,并且同现有直管管束的国家标准与先前的研究成果进行了对比分析,结果为螺旋管式蒸汽发生器的设计与工程评估提供了理论基础。 展开更多
关键词 螺旋管式蒸汽发生器 管束振动 流体弹性不稳定性 临界流速半经验公式
在线阅读 下载PDF
p-τ值对COIL的影响的实验研究 被引量:8
8
作者 房本杰 魏凌云 +2 位作者 陈方 金玉奇 桑凤亭 《强激光与粒子束》 EI CAS CSCD 北大核心 2002年第1期26-28,共3页
实验研究了单重态氧发生器 ( SOG)的 p-τ值 ,即初始氯气分压与停留时间的乘积 ,对化学氧碘激光器 ( COIL)的影响 ,并分析了诸多实验因素对 SOG的 p-τ值的影响。对于提高
关键词 coil SOG p-τ值 化学氧碘激光器 单重态氧发生器
在线阅读 下载PDF
拉伸载荷下非金属敷缆复合连续油管力学行为模拟研究
9
作者 张学敏 张雪茹 +2 位作者 李厚补 齐国权 高雄 《石油钻探技术》 北大核心 2025年第1期94-101,共8页
非金属敷缆复合连续油管在起下及采油过程中因自重而承受拉伸载荷,明确敷缆管在该载荷下的力学行为,可以为敷缆管的安全服役提供指导。采用有限元软件,构建了非金属敷缆复合连续油管的三维数值模型,分析了敷缆管在拉伸载荷下的力学行为... 非金属敷缆复合连续油管在起下及采油过程中因自重而承受拉伸载荷,明确敷缆管在该载荷下的力学行为,可以为敷缆管的安全服役提供指导。采用有限元软件,构建了非金属敷缆复合连续油管的三维数值模型,分析了敷缆管在拉伸载荷下的力学行为及其各结构层的力学响应,探究了敷缆工艺参数(缆线缠绕及分布角度)对敷缆管力学特性的影响。研究表明:在拉伸载荷下,敷缆管所有结构层的应力均因缆线缠绕呈螺旋式分布;敷缆管拉伸至失效时,会经历弹性变形、过渡和屈服变形3个阶段,此时管内缆线处于小塑性均匀变形状态;减小缆线缠绕角度,可以提高敷缆管的弹性模量及其轴向承载能力,但会使敷缆管提前进入过渡阶段,进而发生屈服;缆线分布角度对敷缆管力学特性的影响不大。因此,在生产制造该类敷缆管时应着重考虑管内缆线的缠绕角度,该参数与敷缆管在拉伸载荷下力学性能的相关性较大。 展开更多
关键词 非金属敷缆 连续油管 拉伸载荷 力学特性 缆线 有限元分析
在线阅读 下载PDF
以氮气为载气的千瓦级COIL的初步实验研究 被引量:6
10
作者 房本杰 陈方 +2 位作者 张岳龙 金玉奇 桑凤亭 《强激光与粒子束》 EI CAS CSCD 北大核心 2002年第3期447-450,共4页
首次在氯气流量为 110 mmol/ s、采用方列管型射流式 O2 (1 Δ)发生器 (SPJSOG)以及列阵式超音速氧碘混合喷管的 COIL装置上 ,以氮气替代氦气作为载气进行出光实验研究。初步实验获得 1.8k W的激光输出功率以及
关键词 coil SPJSOG 氮气 激光输出功率 化学效率 国际氧碘化学激光 激光器
在线阅读 下载PDF
COIL运行参量对激光器性能的影响 被引量:4
11
作者 陈云山 李守先 +1 位作者 刘广华 张本爱 《强激光与粒子束》 EI CAS CSCD 北大核心 1999年第3期267-271,共5页
基于物理近似模型和以Navier-Stokes方程求解为中心的数值计算,研究了氧碘化学激光器(COIL)激光性能随一些相关运行参量的变化规律,这些结果将对器件运行条件的选取和实验分析有一定的参考价值。
关键词 coil 运行参量 激光器性能 化学激光器
在线阅读 下载PDF
千瓦级COIL UR90实验研究 被引量:3
12
作者 周大正 金玉奇 +9 位作者 赵彤 孙龙 徐文刚 马月仁 王科 韩新民 崔铁基 桑凤亭 庄琦 杨柏龄 《强激光与粒子束》 EI CAS CSCD 北大核心 1997年第2期215-220,共6页
首次报导了千瓦级化学氧碘激光器(COIL)采用束转动90°环形非稳腔(UR90)的实验结果,测量了输出光斑的近场相位分布及远场强度分布,当激光输出平均功率为2kW时。
关键词 化学激光器 环形非稳腔 光束质量 千瓦级 coil
在线阅读 下载PDF
COIL腔镜高反射率精密测量系统的可靠性分析 被引量:4
13
作者 任钢 蔡邦维 +3 位作者 熊胜明 黄伟 张彬 高丽峰 《强激光与粒子束》 EI CAS CSCD 北大核心 2004年第11期1393-1396,共4页
 利用光腔衰荡光谱技术,建立了氧碘化学激光器腔镜高反射率的精密测量系统。对用直型衰荡光腔时可能影响测量系统精度的各种因素进行了系统的实验研究。采用直型和折叠型衰荡光腔,检测了氧碘化学激光器高反腔镜在1.315μm的反射率。实...  利用光腔衰荡光谱技术,建立了氧碘化学激光器腔镜高反射率的精密测量系统。对用直型衰荡光腔时可能影响测量系统精度的各种因素进行了系统的实验研究。采用直型和折叠型衰荡光腔,检测了氧碘化学激光器高反腔镜在1.315μm的反射率。实验测得COIL凹面高反腔镜反射率为99.770%;平面高反镜反射率为99.917%,测量精度约为10-5。结果表明,该系统可以精密测量氧碘化学激光器腔镜的高反射率,测量结果精确可靠。 展开更多
关键词 光腔衰荡 高反射率 氧碘化学激光器(coil) 可靠性分析
在线阅读 下载PDF
竖直隔板对COIL超扩段流场影响实验研究 被引量:8
14
作者 蔡光明 刘军 +1 位作者 宋影松 王永振 《强激光与粒子束》 EI CAS CSCD 北大核心 2003年第8期729-732,共4页
 通过一系列对比实验比较了隔板对气流转捩点、总压损失、光腔静压的影响,并通过分析阐述了竖直隔板对扩压器内部气流参数产生影响的原因。隔板可以增加超音速区域的长度,并能增加光腔压力分布的稳定性,减小总压损失,增加压力恢复系数...  通过一系列对比实验比较了隔板对气流转捩点、总压损失、光腔静压的影响,并通过分析阐述了竖直隔板对扩压器内部气流参数产生影响的原因。隔板可以增加超音速区域的长度,并能增加光腔压力分布的稳定性,减小总压损失,增加压力恢复系数;隔板厚度对光腔静压的影响较大,需严格控制隔板厚度以避免正激波的产生。 展开更多
关键词 coil 扩压器 隔板
在线阅读 下载PDF
基于双级PNN的直驱永磁同步电机匝间短路故障诊断方法
15
作者 高彩霞 冯凌云 党建军 《河南理工大学学报(自然科学版)》 北大核心 2025年第2期116-127,共12页
目的早期故障的精准定位对于预防电机系统故障恶化和制定故障后运行维护策略至关重要。针对多支路并联直驱永磁同步电机(MB-DDPMSM)匝间短路故障诊断问题,方法提出一种基于双级PNN的匝间短路故障检测与短路线圈自动定位的新方法。首先,... 目的早期故障的精准定位对于预防电机系统故障恶化和制定故障后运行维护策略至关重要。针对多支路并联直驱永磁同步电机(MB-DDPMSM)匝间短路故障诊断问题,方法提出一种基于双级PNN的匝间短路故障检测与短路线圈自动定位的新方法。首先,根据MBDDPMSM特殊的结构特点,选择支路差值电流(BDC)作为故障支路定位特征信号,支路电流残差(BRC)作为短路线圈定位特征信号;其次,建立MB-DDPMSM匝间短路故障状态的有限元模型,利用MB-DDPMSM有限元模型分析短路线圈位置对特征信号的影响规律,并建立BDC与故障支路位置的映射关系以及BRC与短路线圈位置的映射关系,为了消除故障程度对特征信号的影响并增强故障特征,对提取的BDC幅值进行L2范数归一化处理,得到故障支路定位特征向量,对提取的BRC幅值进行Z-Score标准化处理,得到短路线圈定位特征向量;最后,建立基于双级PNN的故障诊断模型,利用第一级PNN实现匝间短路故障检测与故障支路定位,利用第二级PNN实现短路线圈自动定位。结果仿真和实验结果表明,所提出的方法能及时检测出电机早期匝间短路故障并实现短路线圈精准定位,识别正确率达100%。结论基于双级PNN的匝间短路故障诊断模型具有建模简单、收敛速度快、故障诊断精准度高等优势。 展开更多
关键词 直驱永磁同步电机 匝间短路故障 支路差值电流 支路电流残差 双级PNN 短路线圈定位
在线阅读 下载PDF
以氮气为载气COIL的设计与实验 被引量:4
16
作者 房本杰 桑凤亭 +3 位作者 陈方 张岳龙 金玉奇 李庆伟 《强激光与粒子束》 EI CAS CSCD 北大核心 2003年第12期1148-1150,共3页
 根据以氮气为载气的特殊要求,对kW级氧碘化学激光器(COIL)装置的结构进行了有针对性的设计和实验研究。在氯气流量为140mmol/s的情况下,获得了2.6kW的功率,相应的化学效率为20.4%,喷管出口能流密度达到了74W/cm2。这一结果达到了以氦...  根据以氮气为载气的特殊要求,对kW级氧碘化学激光器(COIL)装置的结构进行了有针对性的设计和实验研究。在氯气流量为140mmol/s的情况下,获得了2.6kW的功率,相应的化学效率为20.4%,喷管出口能流密度达到了74W/cm2。这一结果达到了以氦气为载气COIL的水平。 展开更多
关键词 coil 氮气 功率 化学效率 喷管能流密度
在线阅读 下载PDF
N_2-COIL的氧发生器水汽诊断 被引量:1
17
作者 赵伟力 王增强 +3 位作者 房本杰 李君 金玉奇 桑凤亭 《海军工程大学学报》 CAS 北大核心 2006年第6期10-13,25,共5页
在氧碘化学激光(COIL)系统中,水汽是影响激光器输出功率的最重要原因之一,因此测控氧发生器(SOG)出口气流中的水汽含量非常重要.文中利用吸收和发射光谱法对方管式射流氮气氧碘化学激光器(N2-COIL)的氧发生器分别进行了水汽含量测量.测... 在氧碘化学激光(COIL)系统中,水汽是影响激光器输出功率的最重要原因之一,因此测控氧发生器(SOG)出口气流中的水汽含量非常重要.文中利用吸收和发射光谱法对方管式射流氮气氧碘化学激光器(N2-COIL)的氧发生器分别进行了水汽含量测量.测量结果显示,在保持氯气流量一定的前提下,该发生器正常工作状态下水汽百分含量小于9%,且随氧发生器的总压的增加而减小,随氮气流量的增大而增加.该结果表明,气体流速是引起水含量变化的主要原因. 展开更多
关键词 水汽浓度 吸收光谱 发射光谱 coil
在线阅读 下载PDF
COIL亚声速段横向喷流混合流场数值分析 被引量:5
18
作者 胡宗民 孙英英 +1 位作者 吴宝根 姜宗林 《强激光与粒子束》 EI CAS CSCD 北大核心 2005年第4期481-484,共4页
COIL是一个气体动力学、化学反应动力学以及光学相互耦合的复杂过程。作为高总压COIL系统研究的第一步,利用三维CFD技术对传统的COIL亚声速段横向射流混合过程进行了数值分析,讨论了包括压力梯度驱动项的分子扩散机制,得到了横向射流的... COIL是一个气体动力学、化学反应动力学以及光学相互耦合的复杂过程。作为高总压COIL系统研究的第一步,利用三维CFD技术对传统的COIL亚声速段横向射流混合过程进行了数值分析,讨论了包括压力梯度驱动项的分子扩散机制,得到了横向射流的较精细的结构,如马蹄形射流界面、逆旋涡对以及射流剪切层。结果表明,压力梯度驱动项对重、轻组分的扩散作用相反,重组分沿压力梯度正向扩散,轻组分逆压力梯度方向扩散。在射流穿透不足的情况下,仍然在喷管出口得到了约为0. 01cm-1的小信号增益系数。 展开更多
关键词 coil流场 混合 反应 数值分析 三维计算流体动力学
在线阅读 下载PDF
无缓冲气COIL扩压器流场数值模拟 被引量:2
19
作者 孙英英 吴宝根 姜宗林 《强激光与粒子束》 EI CAS CSCD 北大核心 2007年第8期1247-1250,共4页
以无缓冲气化学氧碘激光器(COIL)实验器件的数据计算得到的混合喷管出口参数平均值作为光腔入口条件,对6种不同构型的扩压器从光腔入口至扩压器出口的流场进行了数值模拟,得出了各流场参数分布;对不同构型扩压器的流场特点、总压恢复性... 以无缓冲气化学氧碘激光器(COIL)实验器件的数据计算得到的混合喷管出口参数平均值作为光腔入口条件,对6种不同构型的扩压器从光腔入口至扩压器出口的流场进行了数值模拟,得出了各流场参数分布;对不同构型扩压器的流场特点、总压恢复性能进行了分析;研究了扩压器出口背压对流场参数的影响。结果表明:对于主流无缓冲气的COIL,等截面扩压器具有较好的压力恢复性能;增大扩压器出口背压可以使扩压器的压力恢复性能提高,然而,较高的背压使激波串向光腔方向移动,从而使光腔流场受到干扰,影响光腔的光束质量。 展开更多
关键词 化学氧碘激光器(coil) 扩压器 压力恢复
在线阅读 下载PDF
吸收光谱法测量COIL水含量的实验研究 被引量:1
20
作者 李君 赵伟力 +1 位作者 李红 桑凤亭 《海军工程大学学报》 CAS 北大核心 2005年第4期9-12,共4页
介绍了吸收光谱测量水蒸汽绝对浓度的方法,标定了实验环境下水蒸汽的吸收系数,并在氧碘化学激光器(COIL)上进行了初步的实验研究.测量结果显示,在常规工作条件下由于BHP温度变化所引起的水汽百分含量变化可以忽略,气体流速是引起水汽含... 介绍了吸收光谱测量水蒸汽绝对浓度的方法,标定了实验环境下水蒸汽的吸收系数,并在氧碘化学激光器(COIL)上进行了初步的实验研究.测量结果显示,在常规工作条件下由于BHP温度变化所引起的水汽百分含量变化可以忽略,气体流速是引起水汽含量变化的主要原因. 展开更多
关键词 吸收光谱 水蒸汽 coil
在线阅读 下载PDF
上一页 1 2 212 下一页 到第
使用帮助 返回顶部